Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Classical Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Assessment of the Reversion to Virulence and Protective Efficacy in Pigs Receiving the Live Attenuated Classical Swine Fever Recombinant Vaccine Candidate FlagT4G

Background/Objectives: Control of classical swine fever virus (CSFV) in endemic countries relies on vaccination using live attenuated vaccines (LAVs). Most of these LAVs do not allow for the differentiation of vaccinated animals from infected animals (DIVA) based on their serological response. FlagT4G vaccine is a novel candidate that confers robust protective immunity early after vaccination and shows DIVA capabilities. Methods: This report presents the characterization of FlagT4G virus in terms of the stability of its genomic and attenuated phenotypes assessed by a reversion to virulence protocol, as well as its protective efficacy by determining the minimal protective dose. Results: Results presented here demonstrate that after five consecutive passages in groups of 5-week-old susceptible domestic pigs, FlagT4G virus remains genetically stable, and its attenuated phenotype remains unaltered. In terms of efficacy, FlagT4G virus induced solid protection against the intranasal challenge with 105 tissue culture infectious dose (TCID50) of virulent field isolate Brescia virus, even with a vaccine dose as low as 102 TCID50. Conclusions: Results presented here indicate that the FlagT4G vaccine may be a useful tool for CSFV control.

Immunology↗

Testing and demonstration of model predictive control applied to a radiant slab cooling system in a building test facility

Radiant slab systems have the potential to significantly reduce energy consumption in buildings. However, control of radiant slab systems is challenging. Classical feedback control is inadequate due to the large thermal inertia of the systems and heuristic feed-forward control often leads to unacceptable indoor comfort and may not achieve the full energy savings potential. Model predictive control (MPC) is now attracting increasing interest in the building industry and holds promise for radiant systems. However, an often-cited barrier to its implementation in the building industry is the high computational cost and complexity relative to the feedback controls used in conventional systems. The objectives of this study were to (i) verify the correct operation of an open source MPC toolchain developed for radiant slab systems, and (ii) demonstrate its efficacy in a test facility. A matched pair of cells in the FLEXLAB building test facility at the Lawrence Berkeley National Laboratory was used in the study. The proposed MPC toolchain was implemented in one cell and the performance compared to that of the other cell, which used a conventional heuristic control strategy. Finally, the results showed that the simplified MPC approach applied in the toolchain worked as expected and realized energy savings over the conventional control strategy. The MPC yielded 42% chilled water pump power reduction and 16% cooling thermal energy savings, while maintaining equal or better indoor comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Classical-driving-assisted entanglement dynamics control

We propose a scheme of controlling entanglement dynamics of a quantum system by applying the external classical driving field for two atoms separately located in a single-mode photon cavity. It is shown that, with a judicious choice of the classical-driving strength and the atom–photon detuning, the effective atom–photon interaction Hamiltonian can be switched from Jaynes–Cummings model to anti-Jaynes–Cummings model. By tuning the controllable atom–photon interaction induced by the classical field, we illustrate that the evolution trajectory of the Bell-like entanglement states can be manipulated from entanglement-sudden-death to no-entanglement-sudden-death, from no-entanglement-invariant to entanglement-invariant. Furthermore, the robustness of the initial Bell-like entanglement can be improved by the classical driving field in the leaky cavities. This classical-driving-assisted architecture can be easily extensible to multi-atom quantum system for scalability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MAGNETICALLY CONTROLLED ACCRETION ON THE CLASSICAL T TAURI STARS GQ LUPI AND TW HYDRAE

We present high spectral resolution (R Almost-Equal-To 108, 000) Stokes V polarimetry of the classical T Tauri stars (CTTSs) GQ Lup and TW Hya obtained with the polarimetric upgrade to the HARPS spectrometer on the ESO 3.6 m telescope. We present data on both photospheric lines and emission lines, concentrating our discussion on the polarization properties of the He I emission lines at 5876 A and 6678 A. The He I lines in these CTTSs contain both narrow emission cores, believed to come from near the accretion shock region on these stars, and broad emission components which may come from either a wind or the large-scale magnetospheric accretion flow. We detect strong polarization in the narrow component of the two He I emission lines in both stars. We observe a maximum implied field strength of 6.05 {+-} 0.24 kG in the 5876 A line of GQ Lup, making it the star with the highest field strength measured in this line for a CTTS. We find field strengths in the two He I lines that are consistent with each other, in contrast to what has been reported in the literature on at least one star. We do not detect any polarization in the broad component of the He I lines on these stars, strengthening the conclusion that they form over a substantially different volume relative to the formation region of the narrow component of the He I lines.

79 ASTRONOMY AND ASTROPHYSICS↗

Studies on the Effects of High Renewable Penetrations on Driving Point Impedance and Voltage Regulator Performance: National Renewable Energy Laboratory/Sacramento Municipal Utility District Load Tap Changer Driving Point Impedance Project

Voltage regulators perform as desired when regulating from the source to the load and when regulating from a strong source (utility) to a weak source (distributed generation). (See the glossary for definitions of a strong source and weak source.) Even when the control is provisioned for reverse operation, it has been observed that tap-changing voltage regulators do not perform as desired in reverse when attempting regulation from the weak source to the strong source. The region of performance that is not as well understood is the regulation between sources that are approaching equal strength. As part of this study, we explored all three scenarios: regulator control from a strong source to a weak source (classic case), control from a weak source to a strong source (during reverse power flow), and control between equivalent sources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rotated-Droop Control for Enhanced Stability and Power Decoupling in Microgrids With Complex Line Impedances

Classical droop control in microgrids predominantly assumes inductive line impedance, which simplifies implementation but causes power coupling and steady-state errors in systems with resistive and inductive lines. This paper proposes a rotated-droop control strategy for grid-forming inverters that reformulates the power equations by incorporating the magnitude and angle of the line impedance within a rotated reference frame. This method enhances the decoupling of active and reactive power dynamics without increasing complexity or requiring communication links. A small-signal state-space model was created to capture the dynamic behavior of the system under varying impedance parameters, preserving the original droop gains by rotating the power control structure. This allows eigenvalue-based stability analysis and enhances damping and transient performance. Simulation and experimental results validated the improved power-sharing performance, faster response, and robustness of the proposed method under different impedance conditions. This approach maintains the decentralized structure of the conventional droop control while enabling greater adaptability and scalability, making it suitable for modern inverter-based microgrids with dynamic topologies.

Campo-Ossa, Daniel Dario [Univ. of Puerto Rico, Ag↗

Power-Law Entanglement and Hilbert Space Fragmentation in Nonreciprocal Quantum Circuits

Quantum circuits utilizing measurement to evolve a quantum wave function offer a new and rich playground to engineer unconventional entanglement dynamics. Here, in this work, we introduce a hybrid, nonreciprocal setup featuring a quantum circuit, whose updates are conditioned on the state of a classical dynamical agent. In our example the circuit is represented by a Majorana quantum chain controlled by a classical N-state Potts chain undergoing pair flips. The local orientation of the classical spins controls whether randomly drawn local measurements on the quantum chain are allowed or not. This imposes a dynamical kinetic constraint on the entanglement growth, described by the transfer matrix of an N-colored loop model. It yields an equivalent description of the circuit by an SU(N)-symmetric Temperley-Lieb Hamiltonian or by a kinetically constrained surface growth model for an N-component height field. For N = 2, we find a diffusive growth of the half-chain entanglement toward a stationary profile S(L) ~ L 1/2 for L sites. For N ≥ 3, the kinetic constraints impose Hilbert space fragmentation, yielding subdiffusive growth toward S(L) ~ L 0.57 . This showcases how the control by a classical dynamical agent can enrich the entanglement dynamics in quantum circuits, paving a route toward novel entanglement dynamics in nonreciprocal hybrid circuit architectures.

1-dimensional spin chains↗

CIRCLES: Congestion Impacts Reduction via CAV-in-the-loop Lagrangian Energy Smoothing

The energy efficiency of today’s vehicular mobility relies on the un-integrated combination of i) control via static assets (traffic lights, metering, variable speed limits, etc.); and ii) onboard vehicle automation (adaptive cruise control (ACC), ecodriving, etc.). These two families of control were not co-designed and are not engineered to work in coordination. Recent studies have shown i) limitations of controls, and even ii) negative impacts of ACC. This project focused on the technology development, implementation and prototyping, and validation of Mobile Traffic Control (MTC). MTC can be viewed as an extension of classical traffic control (in which static infrastructure actuates traffic flow). In the MTC paradigm, automated vehicles actuate the entire flow via their behavior, offering enhanced possibilities to optimize the energy footprint of traffic, if designed correctly. We set out to demonstrate for the first time that considerably reduced fuel consumption of all vehicles in traffic can be achieved via distributed control of a small proportion of CAVs. Compared to baseline vehicular technologies, our work offers a significant design departure: control algorithms for the CAVs consider the impact one vehicle can have on overall traffic, improving resulting overall fuel consumption. We focus on using a few vehicles (as traffic controllers via CAV technology) to improve the energy efficiency of traffic flow to further optimize energy efficiency. A live-traffic demonstration in November 2022 featured the deployment of 100 specially-equipped CAVs, constituting an approximate local penetration rate upwards of 2%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reduced order methods for the improvement of control-oriented modelling of nuclear power plants - 185

In the development of the control system of a nuclear power plant, it is of primary importance to rely on simulation tools for its realization, testing and validation. These tools should provide an accurate description of the controlled response of the entire power plant in different scenarios. The classic control-oriented modelling based on 0D/1D approach is well suited for control purposes since it provides fast-running simulations and it is easy to linearize, but it may not be sufficient to deeply investigate the complexity of some systems, in particular when/where spatial phenomena have a remarkable impact on dynamics. Reduced Order Methods (ROMs) can offer the proper trade-off between computational cost and solution accuracy, combining the high-detail modelling (e.g., 3D modelling) usually adopted for design purposes with the requirements demanded for a control-oriented tool, firstly the computational efficiency. In this work, ROMs are used to improve a control-oriented plant simulator of a Lead-cooled Fast Reactor (LFR). In particular, the attention is focused on the reactor core neutronics, and on the thermal-hydraulics of the reactor pool as well. A test case regarding the design of a Kalman Filter is set up showing promising results for the application of ROM in the control context. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of a Proportional-Control-Based Advanced Control Strategy for Independent Temperature and Humidity Control of a Pre-Cooled Desiccant Air Cooling System

In this study, the control of a desiccant-wheel-based evaporative cooling system with a double-layer dew-point cooler system is emphasized. There are two dew-point evaporative coolers in the system and the air taken inside is subjected to pre- and post-cooling processes. The dehumidification process of the air taken in is carried out by the desiccant wheel after the pre-cooling process. A proportional-based control strategy has been developed to adjust the temperature and relative humidity of the room quickly and robustly with different operation modes for actuators to bring comfort with less energy consumption. In addition, an automatic Stop/Run mode has been added to the control strategy to save extra energy. With the developed control strategy, enabling the actuators to switch between the operation modes, more energy savings are achieved compared to both traditional ON/OFF and proportional controls. The accuracy and applicability of the developed control strategy were analyzed and it was observed that the room comfort reached the desired levels successfully under all disruptive effects. The control inputs and the energies consumed by all the actuators were investigated and it was determined that 21.19% more energy savings are provided by adding the automatic Stop/Run feature. With the multi-mode control strategy, a total of 40.90% less energy consumption is achieved compared to the classical ON/OFF control technique. Thus, it is seen that the controller developed for the desiccant-wheel-based evaporative cooler is a viable method to provide fast and robust comfort conditions with less energy.

42 ENGINEERING↗

NMPC for Setpoint Tracking Operation of a Solid Oxide Electrolysis Cell System

Solid oxide electrolysis cells (SOECs) are a promising technology to generate hydrogen through water electrolysis. However, intermittent renewable energy requires SOECs to transition between hydrogen production setpoints as the price of electricity fluctuates. A well-functioning control system is important to avoid cell degradation during setpoint tracking operation. In this work, we apply nonlinear model predictive control (NMPC) to an SOEC module and supporting equipment and compare NMPC performance to classical PI control while ramping between hydrogen production setpoints. We find that these control methods provide similar performance in many metrics, but NMPC significantly reduces cell thermal gradients during the setpoint transition.

Allan, Douglas↗

Application of Hotelling’s T{sup 2} charts in monitoring quality parameters in a drinking water supply system

In water supply systems with distribution networkthe most critical aspects of control and Monitoring of water quality, which generates crises system, are the effects of cross-contamination originated by the network typology. The classics of control of quality systems through the application of Shewhart charts are generally difficult to manage in real time due to the high number of charts that must be completed and evaluated. As an alternative to the traditional control systems with Shewhart charts, this study aimed to apply a simplified methodology of a monitoring plan quality parameters in a drinking water distribution, by applying Hotelling’s T{sup 2} charts and supplemented with Shewhart charts with Bonferroni limits system, whenever instabilities with processes were detected.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generating and controlling chains of entangled atoms by coherent control techniques

A practical way of writing long sequences of entangled atomic qubits using coherent control with classical light sources is proposed. The method utilizes one-photon vs two-photon interference as a means of controlling the directionality of the motion of valence electrons during molecular dissociation processes. We show that, by dissociating in an optical lattice a one-dimensional array of ultracold diatomic molecules (e.g., Na{sub 2}{yields}Na+Na{sup *}), using a combination of photoabsorption of two mutually perpendicularly polarized beams at center frequency {omega} and a coherent Raman transition at frequencies {omega}{sub 1} and {omega}{sub 2}={omega}{sub 1}-{omega}, one can craft entangled states composed of arbitrary superpositions of sequences of atomic states, such as |f>|f>|b>+{center_dot}{center_dot}{center_dot}+|b>|b>|f>+{center_dot}{center_dot}{center_dot}, where |f> designates a dissociation process in which the ground-state Na atom goes in the forwarddirection and the excited-state Na{sup *} goes in the backward direction, while |b> designates the reverse process, namely, Na going in the backward direction and Na{sup *} going in the forward direction. The method, which on the basis of past work is expected to be robust against decoherence, would enable the encoding of very long sequences of entangled qubits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal Voltage Control in Low-Observable Unbalanced Distribution Systems

The increased integration of distributed energy resources (DERs) in distribution systems brings both advantages and technical challenges. High levels of DERs can often cause over/under voltage problems. Classical voltage control algorithms are based on full knowledge of voltage states across all nodes in the system. However, this may not be a practical assumption since many locations in distribution systems are unobservable. Therefore, this paper proposes a new model predictive control (MPC) based control algorithm that accounts for system unobservability to efficiently eliminate voltage violations with as low as 50% fraction of observable nodes. Additionally, an analytical voltage sensitivity framework is employed to quickly determine the change in voltage states due to PV injections. The effectiveness of the proposed method is validated via simulations on the unbalanced IEEE 37 node test system.

Abujubbeh, Mohammad↗

Fuzzy Controllers in the Adaptive Control System of a CNC Lathe

Traditional approaches to improving the technological system of CNC metal-cutting machines include increasing the rigidity, periodic maintenance and repair of its components, and operating at lower speeds. In practice, the most economical approach is stabilization of the inputs to the system. The development of adaptive control systems with stabilization of the cutting forces improves the precision and quality of machining in CNC metal-cutting machines, the productivity, and tool life. However, classical PID controllers are only effective in stabilizing the cutting forces in such systems if continuous real-time parameter adjustment is possible. That sharply increases the complexity of the controller. A new mathematical apparatus based on artificial intelligence (including fuzzy logic) permits the solution of adaptive control problems that previously could hardly even be formulated. The present work addresses the use of fuzzy logic in automatic stabilization of the cutting force for CNC lathes. Simulation of a fuzzy controller shows that this approach to automatic stabilization of the cutting force increases the machining efficiency on existing equipment with indeterminacy in the characteristics of the cutting system and the working environment.

42 ENGINEERING↗

Invariance of the bit error rate in the ancilla-assisted homodyne detection

We investigate the minimum achievable bit error rate of the discrimination of binary coherent states with the help of arbitrary ancillary states. We adopt homodyne measurement with a common phase of the local oscillator and classical feedforward control. After one ancillary state is measured, its outcome is referred to the preparation of the next ancillary state and the tuning of the next mixing with the signal. It is shown that the minimum bit error rate of the system is invariant under the following operations: feedforward control, deformations, and introduction of any ancillary state. We also discuss the possible generalization of the homodyne detection scheme.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗