Measuring Neutrino Oscillations in the NOvA and CHIPS Detectors.

NOvA is a long baseline neutrino experiment which uses muon neutrinos produced by the NuMI beam at the Fermi National Accelerator Laboratory to measure muon neutrino disappearance and electron neutrino appearance, among other analyses. The Far/Near Extrapolation analysis framework (FNEX) was used to measure muon neutrino disappearance using the events observed by NOvA while the NuMI beam was in Forward Horn Current configuration (i.e. this analysis uses neutrino data, not antineutrino data). The values of the parameters measured in this analysis are sin 2 θ 23 - 0.499$^{+0.098}_{-0.069}$ and Δm$^2_{32}$ - 2.454$^{+0.108}_{0.119}$ × 10 -3 eV, which is consistent with the results of NOvA’s main muon neutrino disappearance analysis using the experiment’s usual framework, known as CAF. The CHIPS detector is a water Cherenkov detector currently in construction. It will also use the NuMI beam to perform muon neutrino disappearance and electron neutrino appearance analyses. The necessary water clarity for a detector with a diameter of 25 m and a height of 6 m is discussed, as well as the results of testing water filtration systems. The filtration that will be used for the detector is a 10 µm carbon block filter and a 0.5 µm filter in series, with no reverse osmosis or ultraviolet sterilisation being used. This provides an attenuation length of 16.63 ± 0.25 m for light of 532 nm wavelength (green), so light with a wavelength of 405 nm (violet) would have an attenuation length of 133±2 m. The greatest possible distance between a PMT and any point in the detector’s volume is approximately 26 m, so 133 m is sufficient for the detector to measure Cherenkov light produced anywhere in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cherenkov Photon Background for Low-Noise Detectors in Space

Future space observatories dedicated to the direct imaging and spectroscopy of extra-solar planets require ultra-low-noise detectors sensitive at ultraviolet (UV) to infrared (IR) wavelengths. When observing faint sources, detector noise must be studied and minimized in order to maximize signal-to-noise (SNR). However, due to the intense radiation environment of space and the demonstrated ultra-low-noise achievable by modern detectors, Cherenkov radiation emerges as a relatively unexplored source of low-energy background.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evidence of Antineutrinos from Distant Reactors Using Pure Water at SNO+

The SNO+ Collaboration reports the first evidence of reactor antineutrinos in a Cherenkov detector. The nearest nuclear reactors are located 240 km away in Ontario, Canada. Here, this analysis uses events with energies lower than in any previous analysis with a large water Cherenkov detector. Two analytical methods are used to distinguish reactor antineutrinos from background events in 190 days of data and yield consistent evidence for antineutrinos with a combined significance of 3.5 σ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Strip-based Scintillation Detector for Dual-readout High-granularity Calorimetry

New calorimeter technology is being developed for future collider experiments. We are developing a calorimeter that integrates two technologies, a high-granularity calorimeter and a dual-readout calorimeter, and has high time resolution at a picosecond level. The proposed calorimeter is a sampling calorimeter based on scintillation and Cherenkov detectors with high-granularity readout. The Cherenkov detector has a picosecond level time resolution. For the high-granularity scintillation detector, scintillator strips of 300mm × 30mm ×3mm-thick are aligned horizontally and vertically to realize an effective 30mm-square-cell segmentation. Prototype strips with different designs and scintillator materials were tested to compare the performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Event Reconstruction for Water-based Liquid Scintillator Detectors

Water Cherenkov and liquid scintillator detectors represent two complementary approaches in neutrino physics. Water Cherenkov detectors provide particle track direction and particle identification (PID) through Cherenkov ring topology, while liquid scintillator detectors offer higher light yield and lower energy thresholds. Water-based liquid scintillator (WbLS) is designed to combine the advantages of both technologies. However, the simultaneous detection of Cherenkov and scintillation light by photosensors introduces significant challenges for event reconstruction. This poster presents event reconstruction studies for WbLS detectors. A likelihood-based reconstruction framework, fiTQun, has been successfully used in Super-Kamiokande to reconstruct water Cherenkov events in cylindrical detectors. We extend and improve this framework to demonstrate event reconstruction in WbLS detectors, enabling the concurrent reconstruction of particle energy, PID, vertex, and direction. The results demonstrate competitive performance in energy resolution, PID separation, and vertex and direction reconstruction, highlighting the strong potential of WbLS for next-generation neutrino experiments.

Xie, Zhenxiong [Minnesota U.] (ORCID:0009000301442↗

Excellent Timing Cherenkov Light Detection for Dual-readout High-granularity Calorimetry

We are developing a Cherenkov detector aiming for applications in the next-generation calorimetry. It is a calorimetry that combines dual-readout and high-granularity with excellent timing capability. This work is to prove the concept of the Cherenkov detector utilizing a resistive plate chamber (RPC) with Diamond-Like Carbon as resistive electrode. The first prototype was tested with β-rays and cosmic-rays. This paper discusses the behavior of the charge spectrum and the time resolution of the first prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cherenkov Gamma Ray Detectors on High-Energy-Density Systems

Cherenkov gamma ray detectors are a valuable diagnostic technique for HED systems. Inertial confinement fusion is working towards high gain ignition. Gamma rays from ICF systems can help inform the degradation mechanisms preventing ignition: Carbon ablator is not being degraded, unlike the DT fuel; carbon γ timing can estimate shell energy during bangtime and may suggest hot spot cooling rate; and Cherenkov detectors are also used for high spatial and temporal resolution ICF mix studies on OMEGA. Cherenkov systems also inform energy spectrum of radiographic sources: ARC laser and Mercury pulsed power machine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical calibration of the SNO+ detector in the water phase with deployed sources

SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. Finally, the calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.

47 OTHER INSTRUMENTATION↗

Measurement of the B 8 solar neutrino flux using the full SNO + water phase dataset

The SNO+ detector operated initially as a water Cherenkov detector. The implementation of a sealed cover gas system midway through water data taking resulted in a significant reduction in the activity of 222 Rn daughters in the detector and allowed the lowest background to the solar electron scattering signal above 5 MeV achieved to date. This paper reports an updated SNO+ water phase 8 B solar neutrino analysis with a total livetime of 282.4 days and an analysis threshold of 3.5 MeV. The 8 B solar neutrino flux is found to be (2.3⁢2$^{+0.18}_{-0.17}⁢$(stat)$^{+0.07}_{-0.05}$⁢(syst))×10 6 cm -2 s -1 assuming no neutrino oscillations, or (5.3⁢6$^{+0.41}_{-0.39}⁢$(stat)+$^{0.17}_{-0.16}$⁢(syst))×10 6 cm -2 s -1 assuming standard neutrino oscillation parameters, in good agreement with both previous measurements and standard solar model calculations. The electron recoil spectrum is presented above 3.5 MeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Auger@TA: In-situ Cross-Calibration of the World's Largest Cosmic Ray Observatories

The Pierre Auger Observatory (Auger) and the Telescope Array (TA) are the world's two largest ultra-high-energy cosmic ray (UHECR) observatories. They operate in the Southern and Northern hemispheres, respectively, at similar latitudes but with distinct surface detector (SD) designs. A significant challenge in studying UHECR physics across the full sky is the apparent discrepancy in flux measurements between the two experiments. This discrepancy could arise from astrophysical differences and/or systematic effects related to their detector designs and sensitivities to extensive air shower components. To address this, the Auger@TA working group aims to cross-calibrate the two observatories with a self-triggering micro-Auger array within the TA array. This micro-array consists of eight Auger Surface Detector (SD) stations equipped with Water Cherenkov Detectors (WCDs) and AugerPrime Surface Scintillator Detectors. Seven SD stations, configured with a centered-1-PMT design, are arranged in a hexagonal pattern with one station in the center, with 1.5 km spacing, mirroring the Auger layout. The eighth station, which features a standard 3-PMT Auger station, is located in conjunction with a TA detector at the center of the hexagon, forming a triplet for high-statistics and low-uncertainty cross-calibration. A custom communication system that uses readily available components enables seamless communication between stations and remote access to each station through a central computer. The micro-array is now fully deployed, and initial data-taking is about to start. This presentation will detail the instrumentation, communication systems, central data acquisition system, expected performance of the micro-array, and preliminary results as appropriate.

Mocellin, Adriel G.B. [Colorado School of Mines]↗

Characterization of Multianode Photomultiplier Tubes for use in the CLAS12 RICH detector

In this work, we present results of the detailed study of several hundred Hamamatsu H12700 Multianode Photomultiplier Tubes (MaPMTs), characterizing their response to the Cherenkov light photons in the second Ring Imaging Cherenkov detector, a part of the CLAS12 upgrade at Jefferson Lab. The total number of pixels studied was 25536. The single photoelectron spectra were measured for each pixel at different high voltages and light intensities of the laser test setup. Using the same dedicated front-end electronics as in the first RICH detector, the setup allowed us to characterize each pixel’s properties such as gain, quantum efficiency, signal crosstalk between neighboring pixels, and determine the signal threshold values to optimize their efficiency to detect Cherenkov photons. A recently published state-of-the-art mathematical model, describing photon detector response functions measured in low light conditions, was extended to include the description of the crosstalk contributions to the spectra. The database of extracted parameters will be used for the final selection of the MaPMTs, their arrangement in the new RICH detector, and the optimization of the operational settings of the front-end electronics. The results show that the characteristics of the H12700 MaPMTs satisfy our requirements for the position-sensitive single photoelectron detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single particle detection system for strong-field QED experiments

Abstract Measuring signatures of strong-field quantum electrodynamics (SF-QED) processes in an intense laser field is an experimental challenge: it requires detectors to be highly sensitive to single electrons and positrons in the presence of the typically very strong x-ray and γ -photon background levels. In this paper, we describe a particle detector capable of diagnosing single leptons from SF-QED interactions and discuss the background level simulations for the upcoming Experiment-320 at FACET-II (SLAC National Accelerator Laboratory). The single particle detection system described here combines pixelated scintillation LYSO screens and a Cherenkov calorimeter. We detail the performance of the system using simulations and a calibration of the Cherenkov detector at the ELBE accelerator. Single 3 GeV leptons are expected to produce approximately 537 detectable photons in a single calorimeter channel. This signal is compared to Monte-Carlo simulations of the experiment. A signal-to-noise ratio of 18 in a single Cherenkov calorimeter detector is expected and a spectral resolution of 2% is achieved using the pixelated LYSO screens.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Construction of a Cosmic Ray Telescope for the hpDIRC Radiators at the Electron Ion Collider

Nuclear physics pertains to the understanding of the structure and dynamics of the nuclei of atoms, accounting for almost all of the visible matter in the universe. The future Electron-Ion Collider (EIC) will play a crucial role in discovering new laws of Nuclear physics. A pivotal aspect of the EIC is exceptional particle identification (PID). Identifying charged hadrons in their final state can be done with special types of Cherenkov Detectors. One type of detector utilizes the Detection of Internally Reflected Cherenkov radiation (DIRC) phenomena. Able to provide precise PID separation up to relatively high momenta, DIRC radiators, made of synthetic fused silica, produce Cherenkov radiation when hit by high energy electromagnetically charged particles. In this thesis we present details of the construction of a cosmic ray telescope (CRT) to utilize high energy muons from cosmic rays to test DIRC radiators. These types of radiators will be used for the high-performance DIRC (hpDIRC) to be used in the ePIC detector in the future EIC. We go into detail on the DIRC process and the individual pieces of hardware required to make the CRT. Lots of labor was used for certain parts of the CRT, specifically the construction of a dark box for the DIRC radiators. The CRT construction and implementation of all of its components are planned to be completed before 2025.

Shankman, Nathan↗

Characterisation of signal-induced noise in Hamamatsu R11265 Multianode Photomultiplier Tubes

Signal-induced noise is observed in Hamamatsu R11265 Multianode Photomultiplier Tubes, manifesting up to several microseconds after the single photoelectron response signal and localised in specific anodes. The mean number of noise pulses varies between devices, and shows significant dependence on the applied high-voltage. The characterisation of this noise and the mitigation strategies to perform optimal single-photon counting at 40 MHz, as required by the LHCb Ring-Imaging Cherenkov detectors, are reported.

47 OTHER INSTRUMENTATION↗

Multi-pulse time resolved gamma ray spectroscopy of the advanced radiographic capability using gas Cherenkov diagnostics

The advanced radiographic capability located at the National Ignition Facility (NIF) uses high intensity, short pulse lasers to create bright photon sources for diagnosing high energy density experiments. There are radiographic needs for a multi-frame time-resolved MeV gamma diagnostic for experiments on the NIF with sub-nanosecond resolution. A series of experiments demonstrated measurements of MeV x-ray spectra resolved with a time separation of a few nanoseconds through the use of gas Cherenkov detectors. In this work, a two-pulse radiographic experiment found a 30% reduction in > 2.8 MeV photon flux compared to the first frame exposure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The large-area hybrid-optics CLAS12 RICH: First years of data-taking

The CLAS12 deep-inelastic scattering experiment at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab conjugates luminosity and wide acceptance to study the 3D nucleon structure in the yet poorly explored valence region, and to perform precision measurements in hadron spectroscopy. A large area ring-imaging Cherenkov detector has been designed to achieve the required hadron identification in the momentum range from 3 GeV/c to 8 GeV/c, with the kaon rate about one order of magnitude lower than the rate of pions and protons. The adopted solution comprises aerogel radiator and composite mirrors in a novel hybrid optics design, where either direct or reflected light could be imaged in a high-packed and high-segmented photon detector. The first RICH module was assembled during the second half of 2017 and installed at the beginning of January 2018, in time for the start of the experiment. The second RICH module, planned with the goal to be ready for the beginning of the operation with polarized targets, has been timely built despite the complications caused by the pandemic crisis and successfully installed in June 2022. Finally, the detector performance is here discussed with emphasis on the operation and stability during the data-taking, calibration and alignment procedures, reconstruction and pattern recognition algorithms, and particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of multi neutron-to-gamma converter array for measuring time resolved ion temperature of inertial confinement fusion implosions

The ion temperature varying during inertial confinement fusion implosions changes the amount of Doppler broadening of the fusion products, creating subtle changes in the fusion neutron pulse as it moves away from the implosion. A diagnostic design to try to measure these subtle effects is introduced—leveraging the fast time resolution of gas Cherenkov detectors along with a multi-puck array that converts a small amount of the neutron pulse into gamma-rays, one can measure multiple snapshots of the neutron pulse at intermediate distances. Further, precise measurements of the propagating neutron pulse, specifically the variation in the peak location and the skew, could be used to infer time-evolved ion temperature evolved during peak compression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Super-Kamiokande Operations (Final Scientific/Technical Report)

The Super-Kamiokande experiment (SK, or Super-K) is based on a 50-kton water Cherenkov detector with 11,129 photomultiplier tubes. The detector is located in the Kamioka mine near Toyama, Japan. The detector has been operating since 1996. The collaboration is now around 165 people, mostly from the U.S. and Japan, but including Canada, the UK, S. Korea, Italy, China, Poland, France and Spain. Notable accomplishments so far include: the discovery of neutrino oscillations using atmospheric and solar neutrinos (and thus demonstrating that neutrinos have mass), the confirmation of these oscillations as the far detector of the K2K long baseline experiment, the first observation of v e appearance and non-zero θ 13 in a long baseline (T2K) beam, the world’s strictest limits on proton decay, the world’s best limits on indirect dark matter annihilation at moderate energies, sensitivity to a galactic supernova over most of the running time since 1996, the world’s best limit on diffuse supernova neutrinos, the first direct indication of matter effects on neutrino oscillations, and a number of other published results and theses in particle astrophysics.