Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cherenkov detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Energy response characterization of current-mode MeV Cherenkov aerogel detectors

Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm 3 , from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space Radiation Detector with Spherical Geometry

A particle detector is provided, the particle detector including a spherical Cherenkov detector, and at least one pair of detector stacks. In an embodiment of the invention, the Cherenkov detector includes a sphere of ultraviolet transparent material, coated by an ultraviolet reflecting material that has at least one open port. The Cherenkov detector further includes at least one photodetector configured to detect ultraviolet light emitted from a particle within the sphere. In an embodiment of the invention, each detector stack includes one or more detectors configured to detect a particle traversing the sphere.

Wrbanek, John D.↗

Space Radiation Detector with Spherical Geometry

A particle detector is provided, the particle detector including a spherical Cherenkov detector, and at least one pair of detector stacks. In an embodiment of the invention, the Cherenkov detector includes a sphere of ultraviolet transparent material, coated by an ultraviolet reflecting material that has at least one open port. The Cherenkov detector further includes at least one photodetector configured to detect ultraviolet light emitted from a particle within the sphere. In an embodiment of the invention, each detector stack includes one or more detectors configured to detect a particle traversing the sphere.

Wrbanek, John D.↗

Scintillation Detector for the Measurement of Ultra-Heavy Cosmic Rays on the Super-TIGER Experiment

We discuss the design and construction of the scintillation detectors for the Super-TIGER experiment. Super-TIGER is a large-area (5.4sq m) balloon-borne experiment designed to measure the abundances of cosmic-ray nuclei between Z= 10 and Z=56. It is based on the successful TIGER experiment that flew in Antarctica in 2001 and 2003. Super-TIGER has three layers of scintillation detectors, two Cherenkov detectors and a scintillating fiber hodoscope. The scintillation detector employs four wavelength shifter bars surrounding the edges of the scintillator to collect the light from particles traversing the detector. PMTs are optically coupled at both ends of the bars for light collection. We report on laboratory performance of the scintillation counters using muons. In addition we discuss the design challenges and detector response over this broad charge range including the effect of scintilator saturation.

Link, Jason↗

Convolutional Neural Networks for the CHIPS Neutrino Detector R&D Project.

The CHerenkov detectors In mine PitS (Chips) neutrino detector R&D project aims to develop novel strategies and technologies for very large yet ‘cheap as chips’ water Cherenkov neutrino detectors. Via deployment in a body of water, use of commercially available components, and instrumentation coverage optimisation for the study of exclusively accelerator beam neutrinos, Chips will enable megaton scale detectors to become a reality at the cost of $200k-$300k per kt of sensitive mass. During the summer of 2019 a prototype Chips detector, Chips-5, was deployed into the Wentworth 2W disused mine pit in northern Minnesota, 7 mrad off the NuMI beam axis. A novel data acquisition system was introduced using cheap single-board computers and open-source software. This work presents a novel approach to water Cherenkov neutrino detector event reconstruction and classification. Three forms of a Convolutional Neural Network, a type of deep learning algorithm, have been trained to reject cosmic muon events, classify beam events, and estimate neutrino energies, all using only the raw detector event as input. When evaluated on the expected distribution of Chips-5 events, this new approach is shown to be robust and explainable as well as providing a significant performance increase over the standard likelihood-based reconstruction and simple neural network classification. Promisingly, the performance presented here is comparable to the more complex (and expensive) neutrino oscillation experiments within the field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of fusion reaction history in inertially confined burning plasmas

Direct evidence of inertially confined fusion ignition appears in the abrupt temperature increase and consequent rapid increase in the thermonuclear burn rate as seen in the reaction history. The Gamma Reaction History (GRH) and Gas Cherenkov Detector (GCD) diagnostics are γ-based Cherenkov detectors that provide high quality measurements of deuterium–tritium fusion γ ray production and are, thus, capable of monitoring the thermonuclear burn rate. Temporal shifts in both peak burn time and burn width have been observed during recent high-yield shots (yields greater than 1017 neutrons) and are essential diagnostic signatures of the ignition process. While the current GRH and GCD detectors are fast enough to sense the changes of reaction history due to alpha heating, they do not have enough dynamic range to capture the onset of alpha heating. The next generation of instrumentation, GRH-15m, is proposed to increase the yield-rate coverage to measure the onset of alpha-heating.

42 ENGINEERING↗

Exclusion and Verification of Remote Nuclear Reactors with a 1-kiloton Gd -Doped Water Detector

To date, antineutrino experiments built for the purpose of demonstrating a nonproliferation capability have typically employed organic scintillators situated as close to the core as possible (typically at a distance of a few meters to tens of meters) and have not exceeded a few tons in size. One problem with this approach is that proximity to the reactor core requires accommodation by the host facility. Water Cherenkov detectors located offsite, at distances of a few kilometers or greater, may facilitate nonintrusive monitoring and verification of reactor activities over a large area. As the standoff distance increases, the detector target mass must scale accordingly. This paper quantifies the degree to which a kiloton-scale gadolinium-doped water Cherenkov detector can exclude the existence of undeclared reactors within a specified distance, and remotely detect the presence of a hidden reactor in the presence of declared reactors, by verifying the operational power and standoff distance using a Feldman-Cousins-based likelihood analysis. A 1-kton scale (fiducial) water Cherenkov detector can exclude gigawatt-scale nuclear reactors up to tens of kilometers within a year. In conclusion, when attempting to identify the specific range and power of a reactor, the detector energy resolution is not sufficient to delineate between the two.

42 ENGINEERING↗

Measurement of neutron-proton capture in the $\mathrmSNO+ water phase

The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV γ 's produced by neutron capture on hydrogen were made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV γ. Analysis of the delayed coincidence between the 4.4-MeV γ and the 2.2-MeV capture γ revealed a neutron detection efficiency that is centered around 50% and varies at the level of 1% across the inner region of the detector, which to our knowledge is the highest efficiency achieved among pure water Cherenkov detectors. Finally, in addition, the neutron capture time constant was measured and converted to a thermal neutron-proton capture cross section of $336.3^{+1.2}_{-1.5}$ mb .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring Neutrino Oscillations in the NOvA and CHIPS Detectors.

NOvA is a long baseline neutrino experiment which uses muon neutrinos produced by the NuMI beam at the Fermi National Accelerator Laboratory to measure muon neutrino disappearance and electron neutrino appearance, among other analyses. The Far/Near Extrapolation analysis framework (FNEX) was used to measure muon neutrino disappearance using the events observed by NOvA while the NuMI beam was in Forward Horn Current configuration (i.e. this analysis uses neutrino data, not antineutrino data). The values of the parameters measured in this analysis are sin 2 θ 23 - 0.499$^{+0.098}_{-0.069}$ and Δm$^2_{32}$ - 2.454$^{+0.108}_{0.119}$ × 10 -3 eV, which is consistent with the results of NOvA’s main muon neutrino disappearance analysis using the experiment’s usual framework, known as CAF. The CHIPS detector is a water Cherenkov detector currently in construction. It will also use the NuMI beam to perform muon neutrino disappearance and electron neutrino appearance analyses. The necessary water clarity for a detector with a diameter of 25 m and a height of 6 m is discussed, as well as the results of testing water filtration systems. The filtration that will be used for the detector is a 10 µm carbon block filter and a 0.5 µm filter in series, with no reverse osmosis or ultraviolet sterilisation being used. This provides an attenuation length of 16.63 ± 0.25 m for light of 532 nm wavelength (green), so light with a wavelength of 405 nm (violet) would have an attenuation length of 133±2 m. The greatest possible distance between a PMT and any point in the detector’s volume is approximately 26 m, so 133 m is sufficient for the detector to measure Cherenkov light produced anywhere in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cherenkov Photon Background for Low-Noise Detectors in Space

Future space observatories dedicated to the direct imaging and spectroscopy of extra-solar planets require ultra-low-noise detectors sensitive at ultraviolet (UV) to infrared (IR) wavelengths. When observing faint sources, detector noise must be studied and minimized in order to maximize signal-to-noise (SNR). However, due to the intense radiation environment of space and the demonstrated ultra-low-noise achievable by modern detectors, Cherenkov radiation emerges as a relatively unexplored source of low-energy background.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evidence of Antineutrinos from Distant Reactors Using Pure Water at SNO+

The SNO+ Collaboration reports the first evidence of reactor antineutrinos in a Cherenkov detector. The nearest nuclear reactors are located 240 km away in Ontario, Canada. Here, this analysis uses events with energies lower than in any previous analysis with a large water Cherenkov detector. Two analytical methods are used to distinguish reactor antineutrinos from background events in 190 days of data and yield consistent evidence for antineutrinos with a combined significance of 3.5 σ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing the Properties of Superheavy Dark Matter Annihilating or Decaying into Neutrinos With Ultra-High Energy Neutrino Experiments

The evidence for dark matter particles,x, is compelling based on Galactic to cosmological scale observations. Thus far, the promising weakly interacting massive particle scenario have eluded detection, motivating alternative models of dark matter. We consider scenarios involving super-heavy dark matter (SHDM) that potentially can decay or annihilate to neutrinos and antineutrinos. In the mass range m(sub x) =10(exp 7) −10(exp 15) GeV, we evaluate the sensitivities of future observatories PO-EMMA and GRAND for indirect dark matter detection via the measurement of neutrino-induced extensive air showers (EAS), compute the Auger and ANITA limits using their last up-to-date sensitivities, and compare them with IceCube limits. We also show that the uncertainties related to the dark matter distribution in the Galactic halo have a large impact on the neutrino flux. We show that a ground-based radio detector such as GRAND can achieve high sensitivities due to its large effective area and high duty cycle. Space-based Cherenkov detectors such as POEMMA that measure the EAS optical Cherenkov signal have the advantage of full-sky coverage and rapid slewing, enabling an optimized SHDM observation strategy focusing on the Galactic Center. We show that increasing the field of view of the Cherenkov detectors can significantly enhance the sensitivity. Moreover, POEMMA’s fluorescence observation mode that measures EAS above20EeV will achieve state-of-the-art sensitivity to SHDM properties at the highest mass scales.

Claire Guepin↗

Strip-based Scintillation Detector for Dual-readout High-granularity Calorimetry

New calorimeter technology is being developed for future collider experiments. We are developing a calorimeter that integrates two technologies, a high-granularity calorimeter and a dual-readout calorimeter, and has high time resolution at a picosecond level. The proposed calorimeter is a sampling calorimeter based on scintillation and Cherenkov detectors with high-granularity readout. The Cherenkov detector has a picosecond level time resolution. For the high-granularity scintillation detector, scintillator strips of 300mm × 30mm ×3mm-thick are aligned horizontally and vertically to realize an effective 30mm-square-cell segmentation. Prototype strips with different designs and scintillator materials were tested to compare the performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Event Reconstruction for Water-based Liquid Scintillator Detectors

Water Cherenkov and liquid scintillator detectors represent two complementary approaches in neutrino physics. Water Cherenkov detectors provide particle track direction and particle identification (PID) through Cherenkov ring topology, while liquid scintillator detectors offer higher light yield and lower energy thresholds. Water-based liquid scintillator (WbLS) is designed to combine the advantages of both technologies. However, the simultaneous detection of Cherenkov and scintillation light by photosensors introduces significant challenges for event reconstruction. This poster presents event reconstruction studies for WbLS detectors. A likelihood-based reconstruction framework, fiTQun, has been successfully used in Super-Kamiokande to reconstruct water Cherenkov events in cylindrical detectors. We extend and improve this framework to demonstrate event reconstruction in WbLS detectors, enabling the concurrent reconstruction of particle energy, PID, vertex, and direction. The results demonstrate competitive performance in energy resolution, PID separation, and vertex and direction reconstruction, highlighting the strong potential of WbLS for next-generation neutrino experiments.

Xie, Zhenxiong [Minnesota U.] (ORCID:0009000301442↗

Excellent Timing Cherenkov Light Detection for Dual-readout High-granularity Calorimetry

We are developing a Cherenkov detector aiming for applications in the next-generation calorimetry. It is a calorimetry that combines dual-readout and high-granularity with excellent timing capability. This work is to prove the concept of the Cherenkov detector utilizing a resistive plate chamber (RPC) with Diamond-Like Carbon as resistive electrode. The first prototype was tested with β-rays and cosmic-rays. This paper discusses the behavior of the charge spectrum and the time resolution of the first prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Super-TIGER Instrument to Probe Galactic Cosmic Ray Origins

Super-TIGER (Super Trans-Iron Galactic Element Recorder) is under construction for the first of two planned Antarctic long-duration balloon flights in December 2012. This new instrument will measure the abundances of ultra-heavy elements (30Zn and heavier), with individual element resolution, to provide sensitive tests of the emerging model of cosmic-ray origins in OB associations and models of the mechanism for selection of nuclei for acceleration. Super-TIGER builds on the techniques of TIGER, which produced the first well-resolved measurements of elemental abundances of the elements 31Ga, 32Ge, and 34Se. Plastic scintillators together with acrylic and silica-aerogel Cherenkov detectors measure particle charge. Scintillating-fiber hodoscopes track particle trajectories. Super-TIGER has an active area of 5.4 sq m, divided into two independent modules. With reduced material thickness to decrease interactions, its effective geometry factor is approx.6.4 times larger than TIGER, allowing it to measure elements up to 42Mo with high statistical precision, and make exploratory measurements up to 56Ba. Super-TIGER will also accurately determine the energy spectra of the more abundant elements from l0Ne to 28Ni between 0.8 and 10 GeV/nucleon to test the hypothesis that microquasars or other sources could superpose spectral features. We will discuss the implications of Super-TIGER measurements for the study of cosmic-ray origins and will present the measurement technique, design, status, and expected performance, including numbers of events and resolution. Details of the hodoscopes, scintillators, and Cherenkov detectors will be given in other presentations at this conference.

Mitchell, John W.↗

Cherenkov Gamma Ray Detectors on High-Energy-Density Systems

Cherenkov gamma ray detectors are a valuable diagnostic technique for HED systems. Inertial confinement fusion is working towards high gain ignition. Gamma rays from ICF systems can help inform the degradation mechanisms preventing ignition: Carbon ablator is not being degraded, unlike the DT fuel; carbon γ timing can estimate shell energy during bangtime and may suggest hot spot cooling rate; and Cherenkov detectors are also used for high spatial and temporal resolution ICF mix studies on OMEGA. Cherenkov systems also inform energy spectrum of radiographic sources: ARC laser and Mercury pulsed power machine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗