Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Chemometrics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An improved Method for Determining Transient Fuel Dilution of Oil in an Internal-Combustion Engine Using Laser-Induced Florescence and Multivariate Least Square Calibration

An optical diagnostic, based on laser-induced fluorescence (LIF), has been developed for on-engine measurements of real-time fuel dilution of engine oil or fuel in oil (FIO). Fuel dilution of oil is broadly relevant to advancing engine technology including durability, calibration, and catalyst-system management, and believed to promote destructive stochastic pre-ignition (SPI) during high-load engine operations. While standard (e.g., ASTM D3524-90) methods are not capable of real-time transient measurements, the LIF technique resolves transient dilution on the minutes time scale. We have expanded on our original FIO instrument development by introducing an improved analysis based on multivariate least square chemometrics analysis. The measurement uses a fuel dye (180–1300 parts per million, by mass) and monitors for its presence in the oil using 532 nm excitation and LIF. While the original FIO instrument utilized a two-color ratio method for analysis, the improved chemometric analysis uses the fully resolved LIF dye spectra to provide better predictive FIO accuracy (>92%) over a wide FIO range (1.5–14%) typical of engine application. We also investigate the effect of oil temperature on the LIF signal. Limited engine applications for demonstrating and validating the improved FIO instrument are shown, and the related data used to quantify practical detection limit and sensitivity. The improved analysis is insensitive to laser power fluctuation and change in detector integration time, providing an excellent FIO sensitivity (1–2%) and detection limit (0.01 %FIO) over a wide range of loads and injection timings, illustrating this updated approach to be a promising tool for advancing engine technology.

42 ENGINEERING↗

Portable quantitative confocal Raman spectroscopy: Non-destructive approach of the carbonation chemistry and kinetics

Highlights: • Raman spectroscopy was used to monitor carbonation of portlandite • The approach was non-destructive, continuous, and performed within the material • Carbonation was identified coupling Raman spectroscopy and chemometrics • Kinetics was calculated for one portlandite thickness at different CO{sub 2}-percentages Carbonation is one major alteration process of cementitious materials. It can be monitored through several methods, all destructive. In this study, some preliminary investigations were conducted to monitor the carbonation process of pure portlandite with an in situ and non-destructive spectroscopic method. This complementary approach was motivated by a literature review indicating the benefits of Raman spectroscopy, but requiring innovative approaches for data acquisition and analysis. The material was selected to validate this spectroscopic monitoring, coupled with chemometrics tools to allowing an early detection of the carbonation reaction through a structure identified in the spectra data population. The carbonation occurred abruptly, and spectra analysis indicated the occurrence of phases synonymous of microstructural evolutions. Varying the atmospheric percentage of CO{sub 2} (0.04% - 4%) conducted to an appreciation of the kinetics of the carbonation front through the same thickness of portlandite.

36 MATERIALS SCIENCE↗

The controlling role of atmosphere in dawsonite versus gibbsite precipitation from tetrahedral aluminate species

In highly alkaline solution, aluminum speciates as the tetrahedrally coordinated aluminate monomer, Al(OH)4- and/or dimer Al2O(OH)62-, yet precipitates as octahedrally coordinated gibbsite (Al(OH)3). This tetrahedral to octahedral transformation governs Al precipitation, which is crucial to worldwide Al production, and to the processing of caustic high-level radioactive wastes. Despite its significance, the transformation pathway remains unknown. Here we explore the roles of atmospheric water and carbon dioxide in mediating the transformation of the tetrahedrally coordinated potassium aluminate dimer salt (K2Al2O(OH)6) to gibbsite versus potassium dawsonite (KAl(CO3)(OH)2). A combination of in-situ attenuated total reflection infrared spectroscopy, ex-situ micro X-ray diffraction, and multivariate curve resolution-alternating least squares chemometrics analysis reveals that humidity plays a key role in the transformation by limiting the amount of alkalinity neutralization by dissolved CO2. Lower humidity favors higher alkalinity and incorporation of carbonate species in the final Al product to form KAl(CO3)(OH)2. Higher humidity enables more acid generation that destabilizes dawsonite and favors gibbsite as the solubility limiting phase. Because the transformation was restricted to occur in thin water films, the results suggest that transition from tetra- to octahedrally coordinated Al does not have to occur in bulk solution, as has often been hypothesized, but may instead appear on the source mineral surface.

Dembowski, Mateusz↗

pnnl/Chemometric_Toolbox

The PNNL Chemometric Toolbox is a software collection of common MATLAB scripts that implement core chemometric algorithms for regression analysis. The three core regression techniques within this toolbox are classical least squares (CLS), principal component regression (PCR), and partial least squares (PLS). This is demonstrated using a supplied dataset of infrared (FTIR) spectral data with their corresponding concentrations

Smith, Ian↗

Comparing Designed Training Sets to Optimize Multivariate Regression Models for Pr, Nd, and Nitric Acid Using Spectrophotometry

Chemometric regression models were developed for the quantification of praseodymium (Pr, 0–1000 µg/mL), neodymium (Nd, 0–1000 µg/mL), and nitric acid (HNO 3 , 0.1–5 M) using spectrophotometry. Designed calibration sets were composed of 20 samples each: 10 model points and 10 lack-of-fit (LOF) points. The D-optimal designs effectively minimized the number of samples required to build models, and each design resulted in similar prediction performance, suggesting that statistical design of experiments can provide a reliable framework for selecting training set samples in three-variable systems. Partial least squares regression (PLSR) models were validated against a one-factor-at-a-time validation set composed of 125 samples (three variables, five levels). The top PLS-1 models resulted in average percent root mean square error of prediction error values of 3.5%, 1.7%, and 1.2% for Pr(III), Nd(III), and HNO 3 , respectively. Power set augmentations of the model and LOF samples were investigated to optimize the number of training set samples. PLSR models built using just required model points (10) had similar predictive capabilities as models including the LOF points (20) but with fewer samples. The number of validation samples was also varied systematically to learn how many samples are needed to validate regression models. This work addresses long-standing questions in the field of chemometrics to help make this approach amenable to the near-real-time quantification of hazardous species in remote settings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of On-Line Monitoring and Real-Time Characterization of Low Level Waste Samples from Hanford Tanks

Waste and treatment stream characterization is an essential part of safe, efficient, and cost-effective processing of Hanford materials. The demand for materials characterization, including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms, is expected to significantly increase as the U.S. Department of Energy Office of River Protection (ORP) progresses toward Hanford waste treatment and immobilization. The application of on-line monitoring can greatly improve operation timeframes and reduce costs by providing real-time data and supporting the reduction of necessary grab sample collection. Recently, our team applied Raman online monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105, and demonstrated the quantitative measurement of nine analytes within this waste. Application of this method has been expanded to additional Hanford tank wastes, AW-102 and AP-107. The performance of the process monitoring instruments and the accuracy of the chemometric models will be assessed. On-line monitoring results will be compared to anion results determined from the current standard, ion-chromatographic and inductively coupled plasma mass spectrometry methods. Comparisons of both determined values and uncertainties of results will be presented. Results will be shared with personnel working on flowsheet interfaces for the Direct-Feed Low Activity Waste mission at Hanford.

Lines, Amanda M.↗

Application of On-Line Monitoring and Real-Time Characterization of Low Level Waste Samples from Hanford Tanks - 20380

Waste and treatment stream characterization is an essential part of safe, efficient, and cost-effective processing of Hanford materials. The demand for materials characterization, including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms, is expected to significantly increase as the U.S. Department of Energy Office of River Protection (ORP) progresses toward Hanford waste treatment and immobilization. The application of on-line monitoring can greatly improve operation time frames and reduce costs by providing real-time data and supporting the reduction of necessary grab sample collection. Recently, our team applied Raman online monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105, and demonstrated the quantitative measurement of nine analytes within this waste. Application of this method has been expanded to additional Hanford tank wastes, AW-102 and AP-107. The performance of the process monitoring instruments and the accuracy of the chemometric models will be assessed. On-line monitoring results will be compared to anion results determined from the current standard, ion-chromatographic and inductively coupled plasma mass spectrometry methods. Comparisons of both determined values and uncertainties of results will be presented. Results will be shared with personnel working on flowsheet interfaces for the Direct-Feed Low Activity Waste mission at Hanford. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Review of on-line and near real-time spectroscopic monitoring of processes relevant to nuclear material management

Spectroscopic chemometric based on-line monitoring of used nuclear fuel (UNF) reprocessing solutions and characterization of legacy nuclear waste (LNW) stored at Hanford is discussed in this manuscript. Using on-line and near real-time monitoring with spectroscopy, as opposed to traditional off-line monitoring, can significantly reduce the cost, risk and improve the efficiency of characterizing UNF reprocessing streams and LNW since the data can be collected non-destructively and analyzed nearly instantly. It can accurately quantify and qualify nuclear material in near-real time which can help to know the immediate UNF reprocessing stream and LNW conditions and detect the diversion of materials. The ability to be applied in a real reprocessing plant and in an actual Hanford waste tank/transfer pipe has been demonstrated by applying this technique to accurately quantify analytes in real UNF streams and LNW samples. Furthermore, the future development of spectroscopy based on-line monitoring is also discussed in this manuscript.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pu(IV) quantification via visible–near-infrared absorption spectroscopy: tackling interferences using D-optimal design and partial least squares

Here, this study presents a novel analytical approach for quantifying Pu(IV) in glove box environments using fiber-optic-based visible–near-infrared absorption spectroscopy in combination with partial least squares regression (PLSR) and design of experiments. The method addresses significant challenges posed by overlapping spectral features arising from Nd(III), which is a common fission product impurity, and the speciation variability of Pu(IV) nitrato complexes in HNO 3 concentrations ranging from 2.5 to 11 M. A curated training set consisting of data from 20 samples was developed via D-optimal design to enable robust PLSR model calibration for Pu(IV) using the near-infrared band near 1050 nm. The training set was acquired from samples in cuvettes with a 1-cm path length and was used to build the PLSR model. The robustness of the model was validated with data collected using a dip probe with a 1-cm path length and varying Pu(IV) concentrations. The strong performance of the model indicates good model transfer from cuvette to dip probe and highlights the potential for in situ measurements and online monitoring of reactions in a crystallization reactor vessel. The results demonstrate that this combined spectroscopic and chemometric approach can accurately and simultaneously quantify Pu(IV) and HNO 3 , thereby offering a promising tool for real-time monitoring in process environments.

Actinide↗

Combined Raman and Turbidity Probe for Real-Time Analysis of Variable Turbidity Streams

We know that real-time and in situ process monitoring is a powerful tool that can empower operators of hazardous processes to better understand and control their chemical systems without increased risk to themselves. However, applying monitoring techniques to complex chemical processes can face challenges. An example of this is the application of optical spectroscopy, otherwise capable of providing detailed chemical composition information, to processes exhibiting variable turbidity. Here, details on a novel combined Raman spectroscopy and turbidimetry probe are discussed. Furthermore, the analytical approach to accurately account for both Raman signal and turbidity while quantifying chemical targets is detailed. Through leveraging Raman and turbidity data simultaneously collected from the combined probe within chemometric models, accurate quantification of multiple chemical targets can be achieved under conditions of variable concentrations and turbidity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring the Complex Chemistry of Uranium within Molten Chloride Salts

Harsh environments represent a unique opportunity to explore new frontiers in chemistry while developing novel tools to meet global needs. Exploring the chemistry of uranium within molten salts is a key example. Actinide chemistry within the highly ionic environment of a molten salt is poorly understood, particularly in the presence of common salt impurities or without active oxidation state control. Delving into this chemistry can provide new insight into actinide and f-electron interactions. Furthermore, expanding our chemical knowledge can also enable advances in and deployment of molten salt reactors or molten salt recycle schemes. Both molten salt applications aim towards providing green, reliable, and equitable energy as well as critical materials for the world. Here the utilization of visible absorbance and Raman spectroscopies to understand and quantify U within chloride-based salt eutectics is discussed. Furthermore, machine learning techniques in the form of chemometric modelling are developed and described, providing advanced analytical tools to quantify and characterize the U present. In conclusion, these tools are then leveraged to monitor and explore the dynamic fundamental chemistry of U within chloride-based salt melts.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The Fe 4+ / 3+ Redox Mechanism in NaFeO 2 : A Simultaneous Operando Nuclear Resonance and X-ray Scattering Study

Simultaneous operando Nuclear Forward Scattering and transmission X-ray diffraction and 57 Fe Mössbauer spectroscopy measurements were carried out in order to investigate the electrochemical mechanism of NaFeO 2 vs. Na metal using a specifically designed in situ cell. The obtained data were analysed using an alternative and innovative data analysis approach based on chemometric tools such as Principal Component Analysis (PCA) and Multivariate Curve Resolution - Alternating Least Squares (MCR-ALS). This approach, which allows the unbiased extraction of all possible information from the operando data, enabled the stepwise reconstruction of the independent “real” components permitting the description of the desodiation mechanism of NaFeO 2 . This wealth of information allows a clear description of the electrochemical reaction at the redox-active iron centres, and thus an improved comprehension of the cycling mechanisms of this material vs. sodium.

25 ENERGY STORAGE↗

Spatially Resolved Raman Spectroscopy of Thin Carbon Interphase in SiC Ceramic Matrix Composites

A dedicated analysis method is presented to extract the Raman spectrum of an interphase layer thinner than the laser spot size. We focused on spatial correlations between the contrast of optical micrographs and Raman hyperspectral data to predict the constituents of the mixed spectra measured near the interphase. By employing a mapping step size of 0.1 μm, the Raman spectrum of approximately 0.3-μm-thick carbon interphase in a SiC fiber-reinforced SiC matrix composite was extracted from data acquired with a theoretical spot size of about 0.7 μm. Notably, conventional chemometrics procedures were unable to isolate the interphase signal, instead producing a spectrum representing a mixture of interphase and matrix. This study used another composite with approximately 0.9-μm-thick interphase to validate the analysis method, enabling direct measurement of the interphase spectrum. The proposed Raman analysis method has advantages in specimen volume and turnaround time compared to traditional characterization methods, such as transmission electron microscopy. In conclusion, this study also evaluates the applicability of the analysis method to different composite materials and identifies key requirements of the measurements, including the ratio of interphase thickness to spot size and the homogeneity of the surrounding matrix.

ceramic matrix composite↗

SuperCam Calibration Targets: Design and Development

Abstract SuperCam is a highly integrated remote-sensing instrumental suite for NASA’s Mars 2020 mission. It consists of a co-aligned combination of Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), Visible and Infrared Spectroscopy (VISIR), together with sound recording (MIC) and high-magnification imaging techniques (RMI). They provide information on the mineralogy, geochemistry and mineral context around the Perseverance Rover. The calibration of this complex suite is a major challenge. Not only does each technique require its own standards or references, their combination also introduces new requirements to obtain optimal scientific output. Elemental composition, molecular vibrational features, fluorescence, morphology and texture provide a full picture of the sample with spectral information that needs to be co-aligned, correlated, and individually calibrated. The resulting hardware includes different kinds of targets, each one covering different needs of the instrument. Standards for imaging calibration, geological samples for mineral identification and chemometric calculations or spectral references to calibrate and evaluate the health of the instrument, are all included in the SuperCam Calibration Target (SCCT). The system also includes a specifically designed assembly in which the samples are mounted. This hardware allows the targets to survive the harsh environmental conditions of the launch, cruise, landing and operation on Mars during the whole mission. Here we summarize the design, development, integration, verification and functional testing of the SCCT. This work includes some key results obtained to verify the scientific outcome of the SuperCam system.

Manrique, J. A. (ORCID:0000000220532819)↗

Effect of ion interactions on the Raman spectrum of NO 3 − : Toward monitoring of low-activity nuclear waste at Hanford

Raman spectroscopy is a valuable in-situ technique for many applications. The concentrations of species in complex ionic mixtures of nuclear waste can be estimated using Raman measurements. However, it has been experimentally observed that ion interactions can cause a modification of Raman peak intensities and positions. The present work explores the nonlinear behavior associated with the nitrate anion, NO 3 − , which is present in abundance in low activity nuclear waste. We examine changes in the main Raman peak of the nitrate anion in the presence of other ions. A wide range of concentrations are covered, including those expected during direct-feed low-activity waste (DFLAW) processing at the Hanford site in the State of Washington. The experiments showed that the ions interact and associate to form ion pairs, which results in a blue shift (i.e., a shift towards higher wavenumbers) in the main Raman peak of nitrate. The results indicate that cation concentration is a better predictor of the peak shift, compared to ionic strength, both for binary and multicomponent mixtures. These findings have direct implications on the development of spectra-to-composition models for the DFLAW system, since they show deviations from the linearity assumptions used in common chemometric models.

42 ENGINEERING↗

Use of Fisher's Ratio assisted multivariate curve resolution- alternating least squares for discovery-based analysis using ultrahigh pressure liquid chromatography-high resolution mass spectrometry

Non-targeted analysis of complex chemical mixtures can be difficult considering the convoluted nature of the matrix and the potential unknown chemical differences between samples or classes of samples. Ultrahigh pressure liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOF) is an ideal technique to probe chemical differences for a wide variety of samples. While UHPLC-QTOF can discover minute chemical differences down to low part per billion (ppb) concentrations with a high degree of confidence, the application of high-resolution mass spectrometry can yield massive amounts of information (∼ 10 gb per sample) that cannot be analyzed manually. Therefore, the application of chemometric techniques is mandatory for the interrogation of complex samples. Fisher's ratio (FR) assisted multivariate curve resolution-alternating least squares (MCR-ALS) was used to the discover and identify the chemical differences between two classes of materials: 1) a pond water matrix and 2) the matrix spiked with a pharmaceutical standard mix containing 17 compounds. Thirteen of the seventeen spiked compounds were discovered using FR analysis, and then five were successfully deconvoluted using MCR-ALS wherein the number of curves chosen were automatically determined using singular value decomposition (SVD). In conclusion, the use of an automated FR assisted MCR-ALS will aid in discovering trace levels of chemical components without the need for the researcher to provide potentially biased input which will aid in non-targeted workflow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Geochemical advances in Arctic Alaska oil typing – North Slope oil correlation and charge history

The Arctic Alaska petroleum province is geologically and geochemically complex. Mixed hydrocarbon charge from multiple source rocks and/or levels of thermal maturity is common within an individual oil pool. Biomarker and chemometric statistical analyses were used to correlate twenty-nine oils to five oil families derived from: (1) Triassic Shublik Formation (calcareous organofacies), (2) Triassic Shublik Formation (shaly organofacies), (3) Jurassic Kingak Shale, (4) Cretaceous shale (pebble shale unit and Hue Shale), and (5) Paleogene shale (Canning Formation). Age-diagnostic and source-related oil biomarker parameters establish clear genetic relationships between the normal oil-window components and their putative source designations. However, application of diamondoid analyses reveals mixed-oil accumulations with postmature charge contributions (diamondoid-rich and biomarker-poor) in many oils. Most sampled reservoirs contain a predominant charge derived from a single oil-window source plus a minor contribution from one or more higher maturity source(s). Variations in source organofacies also are recognized in the Shublik, Kingak, and Cretaceous oil families. In some cases, oils from multiple pools within a single field display relatively homogeneous geochemical profiles, suggesting a common source and migration pathway. For example, oil from the significant Pikka discovery is inferred to originate mainly from the calcareous Shublik Formation. In other cases, variability among oils from multiple pools within a single field (e.g., Milne Point, Colville River, and Northstar) likely indicates a more complex source, migration, and charge history. The results of this study may be useful for anticipating the composition of oil charge in stratigraphic traps with low-permeability sandstone reservoirs, where oil gravity and other chemical parameters may influence economic viability.

58 GEOSCIENCES↗

New methods for trace analysis of gamma-irradiated pentaerythritol tetranitrate

High explosives (HEs) are used in a diverse range of applications in which they could be exposed to various radiation levels that may cause potential chemical changes. This study further evaluated pentaerythritol tetranitrate (PETN) that was previously aged with a low-level 2 kGy dose of gamma irradiation in order to understand chemical changes caused by irradiation. Both unirradiated PETN and gamma-irradiated PETN were analyzed using ultra high-pressure liquid chromatography coupled to quadrupole time of flight mass spectrometry (UHPLC-QTOF). The resulting data were processed in a non-targeted manner using Fisher's ratio analysis and multivariate curve resolution-alternating least squares (MCR-ALS) to aid in discovery and identification of the chemical changes brought about by irradiation without a priori knowledge. The application of using UHPLC-QTOF in combination with chemometric techniques for the analysis of irradiated samples has not previously been performed. Here, in this work, we show how to use this method to provide chemical information that would otherwise not be discernible, such as the discovery of degradation of the various homologues of PETN. Major differences identified with radiolytic aging of the PETN sample included decomposition products that resulted from the degradation of the trigger linkage – the O–NO 2 bonds – resulting in the formation of alcohol and aldehyde groups. Similar degradation was also observed in the PETN homologues as well as interconversion from one homologue to another.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗