Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Chemometrics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The controlling role of atmosphere in dawsonite versus gibbsite precipitation from tetrahedral aluminate species

In highly alkaline solution, aluminum speciates as the tetrahedrally coordinated aluminate monomer, Al(OH)4- and/or dimer Al2O(OH)62-, yet precipitates as octahedrally coordinated gibbsite (Al(OH)3). This tetrahedral to octahedral transformation governs Al precipitation, which is crucial to worldwide Al production, and to the processing of caustic high-level radioactive wastes. Despite its significance, the transformation pathway remains unknown. Here we explore the roles of atmospheric water and carbon dioxide in mediating the transformation of the tetrahedrally coordinated potassium aluminate dimer salt (K2Al2O(OH)6) to gibbsite versus potassium dawsonite (KAl(CO3)(OH)2). A combination of in-situ attenuated total reflection infrared spectroscopy, ex-situ micro X-ray diffraction, and multivariate curve resolution-alternating least squares chemometrics analysis reveals that humidity plays a key role in the transformation by limiting the amount of alkalinity neutralization by dissolved CO2. Lower humidity favors higher alkalinity and incorporation of carbonate species in the final Al product to form KAl(CO3)(OH)2. Higher humidity enables more acid generation that destabilizes dawsonite and favors gibbsite as the solubility limiting phase. Because the transformation was restricted to occur in thin water films, the results suggest that transition from tetra- to octahedrally coordinated Al does not have to occur in bulk solution, as has often been hypothesized, but may instead appear on the source mineral surface.

Dembowski, Mateusz↗

pnnl/Chemometric_Toolbox

The PNNL Chemometric Toolbox is a software collection of common MATLAB scripts that implement core chemometric algorithms for regression analysis. The three core regression techniques within this toolbox are classical least squares (CLS), principal component regression (PCR), and partial least squares (PLS). This is demonstrated using a supplied dataset of infrared (FTIR) spectral data with their corresponding concentrations

Smith, Ian↗

Comparing Designed Training Sets to Optimize Multivariate Regression Models for Pr, Nd, and Nitric Acid Using Spectrophotometry

Chemometric regression models were developed for the quantification of praseodymium (Pr, 0–1000 µg/mL), neodymium (Nd, 0–1000 µg/mL), and nitric acid (HNO 3 , 0.1–5 M) using spectrophotometry. Designed calibration sets were composed of 20 samples each: 10 model points and 10 lack-of-fit (LOF) points. The D-optimal designs effectively minimized the number of samples required to build models, and each design resulted in similar prediction performance, suggesting that statistical design of experiments can provide a reliable framework for selecting training set samples in three-variable systems. Partial least squares regression (PLSR) models were validated against a one-factor-at-a-time validation set composed of 125 samples (three variables, five levels). The top PLS-1 models resulted in average percent root mean square error of prediction error values of 3.5%, 1.7%, and 1.2% for Pr(III), Nd(III), and HNO 3 , respectively. Power set augmentations of the model and LOF samples were investigated to optimize the number of training set samples. PLSR models built using just required model points (10) had similar predictive capabilities as models including the LOF points (20) but with fewer samples. The number of validation samples was also varied systematically to learn how many samples are needed to validate regression models. This work addresses long-standing questions in the field of chemometrics to help make this approach amenable to the near-real-time quantification of hazardous species in remote settings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pu(IV) quantification via visible–near-infrared absorption spectroscopy: tackling interferences using D-optimal design and partial least squares

Here, this study presents a novel analytical approach for quantifying Pu(IV) in glove box environments using fiber-optic-based visible–near-infrared absorption spectroscopy in combination with partial least squares regression (PLSR) and design of experiments. The method addresses significant challenges posed by overlapping spectral features arising from Nd(III), which is a common fission product impurity, and the speciation variability of Pu(IV) nitrato complexes in HNO 3 concentrations ranging from 2.5 to 11 M. A curated training set consisting of data from 20 samples was developed via D-optimal design to enable robust PLSR model calibration for Pu(IV) using the near-infrared band near 1050 nm. The training set was acquired from samples in cuvettes with a 1-cm path length and was used to build the PLSR model. The robustness of the model was validated with data collected using a dip probe with a 1-cm path length and varying Pu(IV) concentrations. The strong performance of the model indicates good model transfer from cuvette to dip probe and highlights the potential for in situ measurements and online monitoring of reactions in a crystallization reactor vessel. The results demonstrate that this combined spectroscopic and chemometric approach can accurately and simultaneously quantify Pu(IV) and HNO 3 , thereby offering a promising tool for real-time monitoring in process environments.

Actinide↗

Combined Raman and Turbidity Probe for Real-Time Analysis of Variable Turbidity Streams

We know that real-time and in situ process monitoring is a powerful tool that can empower operators of hazardous processes to better understand and control their chemical systems without increased risk to themselves. However, applying monitoring techniques to complex chemical processes can face challenges. An example of this is the application of optical spectroscopy, otherwise capable of providing detailed chemical composition information, to processes exhibiting variable turbidity. Here, details on a novel combined Raman spectroscopy and turbidimetry probe are discussed. Furthermore, the analytical approach to accurately account for both Raman signal and turbidity while quantifying chemical targets is detailed. Through leveraging Raman and turbidity data simultaneously collected from the combined probe within chemometric models, accurate quantification of multiple chemical targets can be achieved under conditions of variable concentrations and turbidity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring the Complex Chemistry of Uranium within Molten Chloride Salts

Harsh environments represent a unique opportunity to explore new frontiers in chemistry while developing novel tools to meet global needs. Exploring the chemistry of uranium within molten salts is a key example. Actinide chemistry within the highly ionic environment of a molten salt is poorly understood, particularly in the presence of common salt impurities or without active oxidation state control. Delving into this chemistry can provide new insight into actinide and f-electron interactions. Furthermore, expanding our chemical knowledge can also enable advances in and deployment of molten salt reactors or molten salt recycle schemes. Both molten salt applications aim towards providing green, reliable, and equitable energy as well as critical materials for the world. Here the utilization of visible absorbance and Raman spectroscopies to understand and quantify U within chloride-based salt eutectics is discussed. Furthermore, machine learning techniques in the form of chemometric modelling are developed and described, providing advanced analytical tools to quantify and characterize the U present. In conclusion, these tools are then leveraged to monitor and explore the dynamic fundamental chemistry of U within chloride-based salt melts.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Spatially Resolved Raman Spectroscopy of Thin Carbon Interphase in SiC Ceramic Matrix Composites

A dedicated analysis method is presented to extract the Raman spectrum of an interphase layer thinner than the laser spot size. We focused on spatial correlations between the contrast of optical micrographs and Raman hyperspectral data to predict the constituents of the mixed spectra measured near the interphase. By employing a mapping step size of 0.1 μm, the Raman spectrum of approximately 0.3-μm-thick carbon interphase in a SiC fiber-reinforced SiC matrix composite was extracted from data acquired with a theoretical spot size of about 0.7 μm. Notably, conventional chemometrics procedures were unable to isolate the interphase signal, instead producing a spectrum representing a mixture of interphase and matrix. This study used another composite with approximately 0.9-μm-thick interphase to validate the analysis method, enabling direct measurement of the interphase spectrum. The proposed Raman analysis method has advantages in specimen volume and turnaround time compared to traditional characterization methods, such as transmission electron microscopy. In conclusion, this study also evaluates the applicability of the analysis method to different composite materials and identifies key requirements of the measurements, including the ratio of interphase thickness to spot size and the homogeneity of the surrounding matrix.

ceramic matrix composite↗

Effect of ion interactions on the Raman spectrum of NO 3 − : Toward monitoring of low-activity nuclear waste at Hanford

Raman spectroscopy is a valuable in-situ technique for many applications. The concentrations of species in complex ionic mixtures of nuclear waste can be estimated using Raman measurements. However, it has been experimentally observed that ion interactions can cause a modification of Raman peak intensities and positions. The present work explores the nonlinear behavior associated with the nitrate anion, NO 3 − , which is present in abundance in low activity nuclear waste. We examine changes in the main Raman peak of the nitrate anion in the presence of other ions. A wide range of concentrations are covered, including those expected during direct-feed low-activity waste (DFLAW) processing at the Hanford site in the State of Washington. The experiments showed that the ions interact and associate to form ion pairs, which results in a blue shift (i.e., a shift towards higher wavenumbers) in the main Raman peak of nitrate. The results indicate that cation concentration is a better predictor of the peak shift, compared to ionic strength, both for binary and multicomponent mixtures. These findings have direct implications on the development of spectra-to-composition models for the DFLAW system, since they show deviations from the linearity assumptions used in common chemometric models.

42 ENGINEERING↗

Use of Fisher's Ratio assisted multivariate curve resolution- alternating least squares for discovery-based analysis using ultrahigh pressure liquid chromatography-high resolution mass spectrometry

Non-targeted analysis of complex chemical mixtures can be difficult considering the convoluted nature of the matrix and the potential unknown chemical differences between samples or classes of samples. Ultrahigh pressure liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOF) is an ideal technique to probe chemical differences for a wide variety of samples. While UHPLC-QTOF can discover minute chemical differences down to low part per billion (ppb) concentrations with a high degree of confidence, the application of high-resolution mass spectrometry can yield massive amounts of information (∼ 10 gb per sample) that cannot be analyzed manually. Therefore, the application of chemometric techniques is mandatory for the interrogation of complex samples. Fisher's ratio (FR) assisted multivariate curve resolution-alternating least squares (MCR-ALS) was used to the discover and identify the chemical differences between two classes of materials: 1) a pond water matrix and 2) the matrix spiked with a pharmaceutical standard mix containing 17 compounds. Thirteen of the seventeen spiked compounds were discovered using FR analysis, and then five were successfully deconvoluted using MCR-ALS wherein the number of curves chosen were automatically determined using singular value decomposition (SVD). In conclusion, the use of an automated FR assisted MCR-ALS will aid in discovering trace levels of chemical components without the need for the researcher to provide potentially biased input which will aid in non-targeted workflow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Geochemical advances in Arctic Alaska oil typing – North Slope oil correlation and charge history

The Arctic Alaska petroleum province is geologically and geochemically complex. Mixed hydrocarbon charge from multiple source rocks and/or levels of thermal maturity is common within an individual oil pool. Biomarker and chemometric statistical analyses were used to correlate twenty-nine oils to five oil families derived from: (1) Triassic Shublik Formation (calcareous organofacies), (2) Triassic Shublik Formation (shaly organofacies), (3) Jurassic Kingak Shale, (4) Cretaceous shale (pebble shale unit and Hue Shale), and (5) Paleogene shale (Canning Formation). Age-diagnostic and source-related oil biomarker parameters establish clear genetic relationships between the normal oil-window components and their putative source designations. However, application of diamondoid analyses reveals mixed-oil accumulations with postmature charge contributions (diamondoid-rich and biomarker-poor) in many oils. Most sampled reservoirs contain a predominant charge derived from a single oil-window source plus a minor contribution from one or more higher maturity source(s). Variations in source organofacies also are recognized in the Shublik, Kingak, and Cretaceous oil families. In some cases, oils from multiple pools within a single field display relatively homogeneous geochemical profiles, suggesting a common source and migration pathway. For example, oil from the significant Pikka discovery is inferred to originate mainly from the calcareous Shublik Formation. In other cases, variability among oils from multiple pools within a single field (e.g., Milne Point, Colville River, and Northstar) likely indicates a more complex source, migration, and charge history. The results of this study may be useful for anticipating the composition of oil charge in stratigraphic traps with low-permeability sandstone reservoirs, where oil gravity and other chemical parameters may influence economic viability.

58 GEOSCIENCES↗

New methods for trace analysis of gamma-irradiated pentaerythritol tetranitrate

High explosives (HEs) are used in a diverse range of applications in which they could be exposed to various radiation levels that may cause potential chemical changes. This study further evaluated pentaerythritol tetranitrate (PETN) that was previously aged with a low-level 2 kGy dose of gamma irradiation in order to understand chemical changes caused by irradiation. Both unirradiated PETN and gamma-irradiated PETN were analyzed using ultra high-pressure liquid chromatography coupled to quadrupole time of flight mass spectrometry (UHPLC-QTOF). The resulting data were processed in a non-targeted manner using Fisher's ratio analysis and multivariate curve resolution-alternating least squares (MCR-ALS) to aid in discovery and identification of the chemical changes brought about by irradiation without a priori knowledge. The application of using UHPLC-QTOF in combination with chemometric techniques for the analysis of irradiated samples has not previously been performed. Here, in this work, we show how to use this method to provide chemical information that would otherwise not be discernible, such as the discovery of degradation of the various homologues of PETN. Major differences identified with radiolytic aging of the PETN sample included decomposition products that resulted from the degradation of the trigger linkage – the O–NO 2 bonds – resulting in the formation of alcohol and aldehyde groups. Similar degradation was also observed in the PETN homologues as well as interconversion from one homologue to another.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis of liquid petroleum using a laser-induced breakdown spectroscopy instrument

Here, a prototype analyzer for the direct LIBS analysis of nebulized liquid samples was developed and tested, particularly for the analysis of petroleum, organic solvents and aqueous solutions. The LIBS analyzer requires about 750 µl of liquid sample, 1 liter of N 2 gas, and 10 s of the analysis time to record 100 spectra. The limits of detection in oil and solvent are as low as 0.01–0.04 ppm for Li, Mg, and Cu. They increase for the difficult elements, such as Pb and Hg (7-10 ppm), Cl (250 ppm), and S (~0.7%). The relative standard deviation of measuring 100 ppm vanadium in oil and solvent was 1.5%. The LIBS detection limits and repeatability are better than required by the standard method ASTM D5185 for the analysis of lubricating oils in ICP-OES. Several petroleum samples were analyzed by LIBS and the quantitative results for V, Ni, and Fe compared to the ICP-OES data. Light crude oils can be nebulized and analyzed directly. Medium crude oils require minimal dilution at least 1:1, otherwise errors of determination become large. Presumably, utilization of the internal standard and chemometrics can be useful to correct for the matrix effects. In addition to the trace element analysis, the LIBS prototype demonstrated ability to measure the hydrogen-to-carbon ratio in organic liquid samples. Several unidentified features were observed in the carbon spectrum. Their possible origin is discussed.

02 PETROLEUM↗

Leveraging visible and near-infrared spectroelectrochemistry to calibrate a robust model for Vanadium(IV/V) in varying nitric acid and temperature levels

Spectroelectrochemistry and optimal design of experiments can be used to rapidly build accurate models for species quantification and enable a greater level of process awareness. Optical spectroscopy can provide vital elemental and molecular information, but several hurdles must be overcome before it can become a widely adopted analytical method for remote analysis in the nuclear field. Analytes with varying oxidation state, acid concentration, and fluctuating temperature must be efficiently accounted for to minimize time and resources in restrictive hot cell environments. The classic one-factor-at-a-time approach is not suitable for frequent calibration/maintenance operations in this setting. Therefore, a novel alternative was developed to characterize a system containing vanadium(IV/V) (0.01–0.1 M), nitric acid (0.1–4 M), and varying temperatures (20–45 °C). Here, spectroelectrochemistry methods were used to acquire a sample set selected by optimal design of experiments. This new approach allows for the accurate analysis of vanadium and HNO 3 concentration by leveraging UV–Vis–NIR absorption spectroscopy with robust and accurate chemometric models. The top model's root mean squared error of prediction percent values were 3.47%, 4.06%, 3.40%, and 10.9% for V(IV), V(V), HNO 3 , and temperature, respectively. These models, efficiently developed using the designed approach, exhibited strong predictive accuracy for vanadium and acid with varying oxidation states and temperature using only spectrophotometry, which advances current technology for real-world hot cell applications. Additionally, Nernstian analysis of the V(IV/V) standard potential was performed using traditional absorbance methods and multivariate curve resolution (MCR). The successful tests demonstrated that MCR Nernst tests may be valuable in highly convoluted spectral systems to better understand the redox processes' behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Method Optimization for Sampling and Analysis Instrumentation

This work presents a generalized approach for analytical method optimization that branches the gap between techniques historically employed and accurate modern optimization techniques suitable for various applications. The novelty of the described strategy is the utilization of multivariate, multiobjective optimization with Karush-Kuhn-Tucker conditions to bound the optimization space to solutions within the physical limitations of instrumentation. Briefly, the basic steps outlined in this paper are to (1) determine the objective(s) that should be maximized or minimized based on the goals of the analytical application, (2) conduct a screening experiment, (3) perform ANOVA to determine the parameters which have a statistically significant effect on the objective, (4) conduct an experiment (e.g., Box-Behnken design) to collect data for fitting the objective equation, and (5) determine the physical constraints of the parameters and solve the Lagrangian to determine the optimal method parameters. A broad approach to optimization target selection allows for robust method tuning to develop improved data sets amenable for chemometrics and machine learning algorithm development. Gas chromatography-mass spectrometry was selected as a use case due to its broad use across scientific fields and time-consuming method development involving numerous parameters. In conclusion, this strategy can reduce the cost of research, improve data quality, and enable the rapid development of new analytical technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-Time Detection of Hydrogen and Ammonia Isotopologues for Impurity Removal and Recovery of Tritium

To accommodate gas measurements for impurity removal and recovery of tritium, a silver-coated optical or waveguide is employed for collecting Raman scattered signals to determine relative hydrogen and ammonia isotopologue populations in real time. The data and results presented here demonstrate an analytical methodology for the analysis of four ammonia and three hydrogen isotopologues in a hydrogen–deuterium exchange reaction by gas phase Raman spectroscopy. Standard chemometric modeling techniques effectively unravel the signatures of the isotopologues involved observed here; however, a sophisticated quantum chemical approach supports the spectral assignments. An interpretation of the data presented here can emphasize the practicality and reliability of the gaseous monitoring system in complex chemical environments for the hydrogen fuel economy as well as the more distant energy source from a facility that handles tritium. There are still considerable concerns about the measurement of tritium in isotope separation and radiological impurities from gas processing. A common impurity in gas processing is ammonia, which can form readily in the presence of nitrogen and tritium. Substituted ammonia (NQ 3 ), where Q = H, D, or T, is traditionally removed through getters or diffusers along with other non-hydrogen contaminants. A preferable analytical approach is noninvasive and can be deployed for real-time process evaluation in radiological environments.

Ammonia↗

Raman Spectroscopic In Situ Monitoring of Highly Turbid Media

The ability to run chemical processing more efficiently and cost effectively is a need that spans critical materials recovery and legacy nuclear waste cleanup. Sensors integrated to provide online monitoring are essential to addressing this need by providing near-real time feedback on process conditions, which can improve efficiency, aid in decision making, and reduce the need for grab sample measurements. Optical spectroscopy is well-suited for providing online chemical composition information and has been widely applied in varied chemical systems. However, applications in turbid matrices continue to represent substantial challenges to sensor performance, where absorption or scattering of excitation light can cause significant signal interference. Here, in this study, close-focus Raman probes are investigated for use in turbid media as a way to overcome the signal loss from the scattering of the Raman excitation source. This, paired with advanced data science techniques, allowed for the development of chemometric models for the accurate quantification of several analytes of interest (NO 3 – , NO 2 – , and PO 4 3– ) in highly turbid solutions with solids loadings of up to 20 wt %. This work focuses on offline sample measurement and characterization as an initial step toward the development of online monitoring capabilities. Chemical systems of interest were focused on nuclear waste at the Hanford Site, which represents highly complex matrices that could realize significant processing benefits through the integration of online monitoring.

Felmy, Heather M. [Pacific Northwest National Labo↗

Quantifying Temperature Dependence of Pu(IV) Absorbance Spectra for Advanced Online Monitoring of Nuclear Processes

This article presents a systematic study of Pu(IV) absorbance spectral features as a function of temperature to develop an understanding of this parameter’s effect on chemometric models that can be used as online monitoring tools to support nuclear processing. The descriptive and predictive models that provide real-time feedback of these processes are usually constructed with data collected in conditions typical of a laboratory environment, which can differ drastically from a processing environment. To assess the impact of temperature on Pu(IV) absorbance spectra, 11 samples of Pu(IV) were synthesized with varying HNO 3 concentrations ranging from 0.6 to 9.5 M and heated between 15 and 45 °C. Ultraviolet (UV)–visible (vis)–near-infrared (NIR) absorption spectra collected at different HNO 3 concentrations and temperatures revealed that features associated with Pu(IV) are sensitive to temperature at all HNO 3 concentrations and that changes in features depend on HNO 3 concentration. The contributions of temperature and HNO 3 concentration to variation in Pu(IV) spectral features were evaluated using the principal component analysis of spectra that were baseline-corrected with an asymmetric least-squares method. Furthermore, predictive modeling for HNO 3 concentration with partial least-squares regression of UV–vis–NIR spectra highlighted the importance of accounting for temperature in the calibration set to optimize model performance. This methodology constitutes a new, systematic approach to account for the effect of temperature on the absorption spectra of metal ions and is useful for process monitoring applications in many industries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray Absorption Spectroscopy Studies of a Molecular CO 2 -Reduction Catalyst Deposited on Graphitic Carbon Nitride

Metal-ligand complexes have been extensively explored as well-defined molecular catalysts in small molecule activation reactions such as carbon dioxide (CO 2 ) reduction. Many hybrid photocatalysts have been prepared by coupling such complexes with photoactive surfaces for use in solar CO 2 reduction. In this work, we employ X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS) spectroscopies, density functional theory (DFT) and computational XANES modeling to interrogate the structure of a hybrid photocatalyst consisting of a macrocyclic cobalt complex deposited on graphitic carbon nitride (C 3 N 4 ). Results show that the cobalt complex binds on C 3 N 4 through surface OH or NH 2 groups. By refining the local geometry and binding sites of this well-defined molecular cobalt complex on C 3 N 4 , here we established an important benchmark for modeling a large class of molecular catalysts that can be adapted to in situ/operando studies and further enhanced by applying chemometrics-based approaches and machine learning methods of XANES data analysis.

36 MATERIALS SCIENCE↗