Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacitance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Design and Laboratory Validation of a Capacitive Sensor for Measuring the Recession of Thin-Layered Ablator

Flight vehicles are typically instrumented with subsurface thermocouples to estimate heat transfer at the surface using inverse analysis procedures. If the vehicle has an ablating heat shield, however, temperature time histories from subsurface thermocouples no longer provide enough information to estimate heat flux at the surface. In this situation, the geometry changes and thermal energy leaves the surface in the form of ablation products. The ablation rate is required to estimate heat transfer to the surface. A new concept for a capacitive sensor has been developed to measure ablator depth using the ablator's dielectric effect on a capacitor's fringe region. Relying on the capacitor's fringe region enables the gage to be flush mounted in the vehicle's permanent structure and not intrude into the ablative heat shield applied over the gage. This sensor's design allows nonintrusive measurement of the thickness of dielectric materials, in particular, the recession rates of low-temperature ablators applied in thin (0.020 to 0.060 in. (0.05 to 0.15 mm)) layers. Twenty capacitive gages with 13 different sensing element geometries were designed, fabricated, and tested. A two-dimensional finite-element analysis was performed on several candidate geometries. Calibration procedures using ablator-simulating shims are described. A one-to-one correspondence between system output and dielectric material thickness was observed out to a thickness of 0.055 in. (1.4 mm) for a material with a permittivity about three times that of air or vacuum. A novel method of monitoring the change in sensor capacitance was developed. This technical memorandum suggests further improvements in gage design and fabrication techniques.

Gregory K Noffz↗

On the Relationship Between Schottky Barrier Capacitance and Mixer Performance at Cryogenic Temperatures

The flat-band voltage is the Schottky junction voltage required to shrink the depletion width to zero. At cryogenic temperatures, mixer diodes are generally biased and/or pumped beyond the flat-band condition to minimize conversion loss and noise figure. This occurs despite the presumed sharp increase in junction capacitance near flat-band, which should instead limit mixer performance. Past moderate forward bias, the diode C-V relationship is difficult to measure. A simple analytic expression for C(V) is usually used to model and predict mixer performance. This letter provides experimental data on C(V) at 77 K based on a microwave measurement and modeling technique. Data is also provided on the conversion loss of a singly balanced mixer optimized for 77 K operation. The connection between junction capacitance, flat-band potential, and conversion loss is examined. It is shown that the analytic expression greatly overestimates the junction capacitance that occurs as flat-band is approached.

Romanofsky, Robert R.↗

Electrical capacitance clearanceometer

A hot gas turbine engine capacitive probe clearanceometer is employed to measure the clearance gap or distance between blade tips on a rotor wheel and its confining casing under operating conditions. A braze sealed tip of the probe carries a capacitor electrode which is electrically connected to an electrical inductor within the probe which is inserted into a turbine casing to position its electrode at the inner surface of the casing. Electrical power is supplied through a voltage controlled variable frequency oscillator having a tuned circuit in which the probe is a component. The oscillator signal is modulated by a change in electrical capacitance between the probe electrode and a passing blade tip surface while an automatic feedback correction circuit corrects oscillator signal drift. A change in distance between a blade tip and the probe electrode is a change in capacitance therebetween which frequency modulates the oscillator signal. The modulated oscillator signal which is then processed through a phase detector and related circuitry to provide an electrical signal is proportional to the clearance gap.

Hester, Norbert J.↗

Dual Cryogenic Capacitive Density Sensor

A dual cryogenic capacitive density sensor has been developed. The device contains capacitive sensors that monitor two-phase cryogenic flow density to within 1% accuracy, which, if temperature were known, could be used to determine the ratio of liquid to gas in the line. Two of these density sensors, located a known distance apart, comprise the sensor, providing some information on the velocity of the flow. This sensor was constructed as a proposed mass flowmeter with high data acquisition rates. Without moving parts, this device is capable of detecting the density change within a two-phase cryogenic flow more than 100 times a second. Detection is enabled by a series of two sets of five parallel plates with stainless steel, cryogenically rated tubing. The parallel plates form the two capacitive sensors, which are measured by electrically isolated digital electronics. These capacitors monitor the dielectric of the flow essentially the density of the flow and can be used to determine (along with temperature) the ratio of cryogenic liquid to gas. Combining this information with the velocity of the flow can, with care, be used to approximate the total two-phase mass flow. The sensor can be operated at moderately high pressures and can be lowered into a cryogenic bath. The electronics have been substantially improved over the older sensors, incorporating a better microprocessor, elaborate ground loop protection and noise limiting circuitry, and reduced temperature sensitivity. At the time of this writing, this design has been bench tested at room temperature, but actual cryogenic tests are pending

Youngquist, Robert↗

Capacitance Based Moisture Sensing for Microgravity Plant Modules: Sensor Design and Considerations

Life support systems for growing plants in microgravity should strive for providing optimal growing conditions and increased automation. Accurately tracking soil moisture content can forward both of these aims, so an attempt was made to instrument a microgravity growth module currently in development, the VEGGIE rooting pillow, in order to monitor moisture levels. Two electrode systems for a capacitance-based moisture sensor were tested. Trials with both types of electrodes showed a linear correlation between observed capacitance and water content over certain ranges of moisture within the pillows. Overall, both types of the electrodes and the capacitance-based moisture sensor are promising candidates for tracking water levels for microgravity plant growth systems.

Schaber, Chad L.↗

Demonstration of a Packaged Capacitive Pressure Sensor System Suitable for Jet Turbofan Engine Health Monitoring

In this paper, the development and characterization of a packaged pressure sensor system suitable for jet engine health monitoring is demonstrated. The sensing system operates from 97 to 117 MHz over a pressure range from 0 to 350 psi and a temperature range from 25 to 500 deg. The sensing system consists of a Clapp-type oscillator that is fabricated on an alumina substrate and is comprised of a Cree SiC MESFET, MIM capacitors, a wire-wound inductor, chip resistors and a SiCN capacitive pressure sensor. The pressure sensor is located in the LC tank circuit of the oscillator so that a change in pressure causes a change in capacitance, thus changing the resonant frequency of the sensing system. The chip resistors, wire-wound inductors and MIM capacitors have all been characterized at temperature and operational frequency, and perform with less than 5% variance in electrical performance. The measured capacitive pressure sensing system agrees very well with simulated results. The packaged pressure sensing system is specifically designed to measure the pressure on a jet turbofan engine. The packaged system can be installed by way of borescope plug adaptor fitted to a borescope port exposed to the gas path of a turbofan engine.

Harsh environment↗

Interfacial Structure and Capacitance of Li-doped Ionic Liquid Electrolytes from Molecular Simulations

Ionic liquids have been proposed as candidate electrolytes for high-energy density, rechargeable batteries, supercapacitors, and hybrid energy storage devices. Though Li-salt is often present in these systems, its influence on interfacial properties is largely uncharacterized. We, thereby, present an extensive computational analysis, supported by experimental comparisons, of the properties of a representative set of these electrolytesat an ideal carbon interface as a function of Li-salt doping and voltage. We have performed polarizable molecular (MD) dynamics simulations, using the APPLEP force field, to evaluate electric double layer (EDL) capacitance and distribution of Li+ in the EDL. Differential capacitance exhibits the characteristic camel profile and is insensitive to Li-doping. Li+ localizes in the second molecular layer of the EDL, which is a result of confinement from free energy barriers associated with ion layering. Joint MDelectronic structure computations show the electrochemical window of the electrolytes to be a weak function of Li-doping. Estimates of supercapacitor specific energy are made using the computed window and capacitance. The magnitude and trends in specific energy are in good agreement with experiment.

batteries↗

Capacitive Micro-Gravity Fluid Mass Gauge

Measuring fluid mass in micro gravity, where fluid behavior is dominated by fluid properties, is a challenging problem. To address this problem engineers at NASA are developing a capacitance-based, mass-fraction gauge for vessels containing two-phase fluids. The vessel volume is enclosed with an array of electrodes, and a unique set of capacitance measurements of the enclosed volume are made between the electrodes. The capacitance measurements are scaled with appropriate weighting factors derived from Laplace's Equation to compensate for the highly non-uniform electric fields inside the measurement volume and achieve a greater level of mass fraction accuracy.

Mark A Nurge↗

Microgravity Electrical Capacitance Tomography Data Set

Propellants mass gauging technologies designed to work in an accelerated environment, where the propellant remains settled at one end of the propellant tank, do not work well in a microgravity environment because the propellant is not necessarily settled. While some microgravity mass gauging technologies exist at various TRLs, most of them have major disadvantages. Improvements in microgravity propellant mass gauging will result in improvements to many areas of propellant management, which influences performance and mission assurance. Electrical Capacitance Tomography (ECT) is a sensing technology that has been used in the oil/gas industry for decades to measure multi-phase flow rate in pipes. ECT, when installed in a tank, is able to reconstruct the liquid distribution inside of the tank, which can then be integrated to obtain mass. ECT mass gauging recently achieved high accuracy in laboratory testing on the ground, and while ECT mass gauging will theoretically work during all phases of flight, it had not yet been tested in microgravity. The NASA KSC Launch Services Program, with support from the Flight Opportunities Program, successfully flew an ECT tank liquid mass gauging system experiment on a Zero-G parabolic flight aircraft. The experiment hardware was rented from a company; NASA LSP did no technology development work for this project. This STRIVES entry is for the entire raw data set, which consists of approximately 25GB of csv files of capacitance and motion data from the ground and flight tests of the experiment. The data set will be available on the NASA LSP Electronic Slosh Data Catalog (ESDC), and the public may request the data set from the authors (POC: Jed Storey, jedediah.m.nasa.gov).

mass gauging↗

Improved circuit for measuring capacitive and inductive reactances

Amplifier circuit measures very small changes of capacitive or inductive reactance, such as produced by a variable capacitance or a variable inductance displacement transducer. The circuit employs reactance-sensing oscillators in which field effect transistors serve as the active elements.

Dalins, I.↗

Capacitance-coupled wiper increases potentiometer life

Capacitively-coupled wiper reduces the friction between the sliding contact and the potentiometer element in conventional potentiometers. A small preamplifier employed close to the wiper reduces errors caused by output cable capacitance. The device is friction free with resultant low wear and has high speed and high resolution.

Dimeff, J.↗

Calibration of a cylindrical RF capacitance probe

The calibration is considered of an RF antenna capacitance probe carried aboard the RAE-1 spacecraft and the correction of the probe for external effects, believed to be primarily due to local positive ion sheaths and/or photoelectron sheaths surrounding the antenna. The RAE-1 spacecraft was launched in July 1968 into a 5850-km. Circular orbit of 121-degree inclination and carried several antenna and radiometer systems covering a frequency range of 0.2 to 9.2 MHz for radio astronomical studies. The RF capacitance probe measurements discussed utilized a 37-meter electric dipole antenna formed by two monopoles made of silver-coated beryllium-copper alloy tapes formed into hollow cylindrical tubes 1.3 cm in diameter.

Mosier, S. R.↗

Calibration of a cylindrical RF capacitance probe

Ambient electron concentrations derived from observations with the Radio Astronomy Explorer 1 antenna capacitance probe have been compared with upper hybrid resonance measurements from the same spacecraft. From this comparison an empirical correction factor for the capacitance probe measurements has been derived. The differences between the two types of measurements is attributed to sheath effects.

Mosier, S. R.↗

A capacitively shunted superconducting microbridge

A superconducting microbridge small enough to exhibit the Josephson effect has been shunted by a large external capacitance. Surprisingly little capacitive hysteresis is observed in its I-V characteristic. Prominent subgap structures are seen. The resistively shunted junction (RSJ) model fails to explain the observations.

Chiao, R. Y.↗

Forward-bias capacitance and current measurements for determining lifetimes and band narrowing in p-n junction solar cells

A new method is described and illustrated for determining the minority-carrier diffusion length and lifetime in the base region of p-n junction solar cells. The method requires only capacitance measurements at the device terminals and its accuracy is estimated to be + or - 5%. It is applied to a set of silicon p-n junction devices and the values of the diffusion lengths agree with those obtained using the current response to X-ray excitation but disagree with those obtained by the OCVD method. The reasons for the relative inaccuracy of OCVD applied to silicon devices are discussed. The capacitance method includes corrections for a two-dimensional fringing effects which occur in small area devices. For a device having highly-doped base region and surface (emitter) layer, the method can be extended to enable the determination of material properties of the degenerately doped surface layer. These material properties include the phenomenological emitter lifetime and a measure of the energy band-gap narrowing in the emitter. An alternate method for determining the energy band-gap narrowing from temperature dependence of emitter current is discussed and demonstrated.

Neugroschel, A.↗

Differential capacitance sensor as position detector for a magnetic suspension densimeter

In the present work, which consists of adapting a magnetic suspension densimeter for use at pressures up to 350 bars, a differential capacitance sensor is developed for use in the servosystem of a magnetic suspension densimeter for detecting the position of a magnetic buoy. This type of sensor has not been used previously in magnetic suspension densimeters. Its design, performance, and advantages are outlined. A cutaway drawing and a schematic diagram of the capacitance sensor and magnetic buoy are presented and described. The concentric-disk design of the sensor capacitor plates and the high degree of symmetry which results from the printed circuit fabrication approach minimize the sensor sensitivity to lateral displacement of the buoy and to the dielectric constant of the surrounding medium. A high-power microscope is necessary to monitor the position of the buoy relative to the support coil.

Frederick, N. V.↗