Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Calorimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Scintillating glass for precision calorimetry in nuclear physics

High-performance scintillator materials are needed for particle identification and measurements of energy and momentum of electromagnetic particles in modern nuclear physics experiments. As an example, the US Electron-Ion Collider, a unique collider with diverse physics topics, requires electromagnetic calorimetry enabling high-quality electron identification and detection in the momentum range of 0.3 to tens of GeV. The highest resolution in electromagnetic calorimeters can be provided by homogeneous materials, e.g., lead tungstate crystals. Inorganic glass scintillators have been investigated as an attractive and cost-effective alternative to crystals, that is also easier and faster to manufacture in mass production. In this paper, we discuss progress in the fabrication and characterization of recent scintillating glass samples on both test bench and beam tests. Further, the results are well-reproduced by simulation and are discussed in the context of the Electron-Ion Collider experimental requirements and bench-marked against lead tungstate crystals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Unveiling the Thermal Stability of Sodium Ion Pouch Cells Using Accelerating Rate Calorimetry

The thermal stability of ~420 mAh Na 0.97 Ca 0.03 [Mn 0.39 Fe 0.31 Ni 0.22 Zn 0.08 ]O 2 (NCMFNZO)/hard carbon (HC) pouch cells was investigated using accelerating rate calorimetry (ARC) at elevated temperatures. 1 m NaPF 6 in propylene carbonate (PC):ethyl methyl carbonate (EMC) (1:1 by volume) was used as a control electrolyte. Adding 2 wt% fluoroethylene carbonate to the electrolyte improves the cell's thermal stability by decreasing the self-heating rate (SHR) across the whole testing temperature range. The selected states-of-charge (SoC), including 70%, 84%, and 100%, exhibit minimal impact on the exothermic behavior, except for a slight decrease in SHR after ~275 °C at 70% SoC. When compared to traditional lithium-ion batteries operating at 100% SoC, NCMFNZO/HC pouch cells demonstrate inferior thermal stability compared to LiFePO 4 (LFP)/graphite pouch cells, displaying a higher SHR from 220 to 300 °C. LiNi 0.8 Mn 0.1 Co 0.1 O 2 /graphite + SiO x pouch cells exhibit the worst safety performance, with an early onset temperature of ~100 °C and the highest SHR across the entire temperature range. These results offer a direct comparison of the impact of SoC and electrolyte compositions on the thermal stability of SIBs at elevated temperatures, highlighting that there is still room for improvement in SIBs safety performance compared to LFP/graphite chemistry.

42 ENGINEERING↗

Investigating the Thermal Behavior of Polymers by Modulated Differential Scanning Calorimetry (MDSC) – A Review

Modulated Differential Scanning Calorimetry (MDSC) is a thermoanalytical technique that detects changes in intrinsic heat flow by subjecting a material to two simultaneous heating rates, one linear and one sinusoidal. In this way, MDSC overcomes the limitations of its predecessor- conventional DSC-allowing for complex and overlapping thermal transitions to be resolved without sacrificing sensitivity. The advantages of MDSC lend credence to its extensive use in applications that require superior analytical accuracy, such as the food and drug industries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crystal Calorimetry for Charged Lepton Flavor Violation Searches

The Mu2e experiment at Fermilab aims to search for Charged Lepton Flavor Violation (CLFV) through the coherent conversion of a muon into an electron in the field of an aluminum nucleus. This process, highly suppressed in the Standard Model, would clearly indicate new physics if observed. A crucial component of Mu2e is its electromagnetic calorimeter, which enhances the identification and measurement of conversion electrons. The calorimeter consists of two disks of undoped CsI crystals read out by custom-designed SiPMs and fast front-end electronics. This paper presents an overview of the calorimeter’s design, its custom SiPM technology, the readout and data acquisition system, and the results from commissioning tests.Building on the experience from Mu2e, the proposed Mu2e-II upgrade aims to enhance further the experiment’s sensitivity by an order of magnitude. This requires significant advancements in calorimeter technology, particularly in crystal materials and photodetector performance. Studies on BaF$_2$ and LYSO crystals, as well as the development of radiation-hard Silicon Photomultipliers (SiPMs), are currently underway. Test beam results demonstrate promising improvements in energy resolution and timing capabilities, ensuring the feasibility of next-generation calorimetry solutions for Mu2e-II.

Atanov, N. [Dubna, JINR]↗

The (Un)reasonable Effectiveness of Neural Network in Cherenkov Calorimetry

We report a greater than factor of two improvement in the hadronic energy resolution of a simulated Cherenkov calorimeter by estimating the energy with machine learning over traditional techniques. The prompt signal formation and energy threshold properties of Cherenkov radiation provide identifiable features that machine learning techniques can exploit to produce a superior model for energy reconstruction. We simulated a quartz-fiber calorimeter via the GEANT4 framework to study the reconstruction techniques in single events. We compared the machine learning-based reconstruction performance to the traditional simple sum of signal and dual-readout techniques that use both Cherenkov and scintillation signals. We describe why this game-changing approach to Cherenkov hadron calorimetry excels and our plans for a dedicated beam test to validate these findings with a fast, radiation-hard hadron calorimeter prototype.

Akchurin, Nural↗

Case Study: Calorimetry

This chapter presents the use of adsorption microcalorimetry to study acid-base catalysis over mixed metal oxides. Understanding the acid-base properties of catalysts is of paramount importance for steering product selectivity in a wide variety of catalytic industrial processes. In particular, catalytic conversion of biomass into biofuels and chemicals demands comprehensive understanding of the acid-base properties of the catalyst to selectively convert functional groups. Herein, the use of probe molecules to measure the strength and density of acid and basic sites on mixed metal oxide surfaces is introduced. Further, the challenges when characterizing mixed metal oxides, presenting surface reconstruction, are explained. An example displays how combining adsorption calorimetry with ab initio calculations explains the activation of a reactant on the surface of a mixed metal oxide. Acid-base catalysis over nanoshapes is studied to unveil that different nanoshapes lead to different extents of surface reconstruction, which ultimately affect acid-base catalysis. The use of steady-state isotopic transient kinetic analysis (SSITKA), in combination with adsorption microcalorimetry, unveils that surface reconstruction of a set of perovskites impacts the density of active sites to a greater extent than the intrinsic reactivity of the active site. At the end of this chapter, fundamental insights into catalyst transient behavior during isomerization of n-butane, and the reaction mechanism for conversion of 4-methylpentan-2-ol, are presented.

Polo Garzon, Felipe↗

Physical characterization of High Entropy Alloys through Differential Scanning Calorimetry and Nanoindentation

In recent years several accelerator facilities have been limiting their beam power output not due to constraint of the accelerators but by concerns on the survivability of their targets, which in turn has led to R&D efforts into new, more resistant materials. One of these novel materials are High Entropy Alloys, the main focus of the internship project. This paper details the activities performed during the CCI 10-week internship by the authors, as well as to discuss the results obtained from said internship. The project consisted of the physical characterization of 12 batches of High Entropy Alloys (HEAs); the methods used to analyze the materials were Nanoindentation, which allows to determine the elastic modulus of the material and its hardness, and Differential Scanning Calorimetry (DSC), allowing the determination of specific heat.

Pacheco Uribe, Rene↗

Hydrothermal solution calorimetry in acidic aqueous solutions and revisiting the standard partial molal thermodynamic properties of Nd 3+ from 25 to 300 °C

The mobility of rare earth elements (REE) can be predicted in aqueous fluids using geochemical modeling but the accuracy of these models strongly depends on the availability of robust thermodynamic properties for the REE aqueous species. The REE 3+ aqua ions are important in the derivation of the formation constants of all the major REE complexes including the chloride, sulfate, and fluoride species which predominate in many hydrothermal-magmatic systems. However, the thermodynamic properties of the REE 3+ aqua ions are still commonly derived from the Helgeson-Kirkham-Flowers (HKF) equation of state parameters tabulated several decades ago. The standard state thermodynamic properties at reference conditions (25 °C and 1bar) and their extrapolations to high temperature need to be verified, if not revised, based on hydrothermal experiments. In this study, the enthalpy of solution was measured for synthetic Nd hydroxide from 25 to 150 ºC to retrieve the standard partial molal thermodynamic properties of Nd 3+ as a function of temperature. The experiments were conducted in aqueous perchloric acid based solutions with starting pH of 2 and varying ionic strength (0.01 to 0.09 mol/kg NaClO 4 ). The standard partial molal enthalpy of formation (Δ f H°) of Nd 3+ derived from the experimental study displays differences of up to 10 kJ/mol compared to the enthalpy values derived from the HKF equation of state in the studied temperature range. These inaccuracies are resolved by adjusting the standard partial molal Gibbs energy of formation (Δ f G°) of Nd 3+ at 25 °C and 1 bar from -672.0 to -679.7 kJ/mol. The heat capacity function (C p °) derived between 25 and 150 ºC can be described by: C p ° = a 0 + a 1 ·T + a 2 ·T -2 , with a 0 = 1256, a 1 = -2.68, a 2 = -55.56·10 6 and T in Kelvin. A set of recommended thermodynamic properties is provided for the Nd 3+ aqua ions and corrections are provided for the chloride and fluoride species to remain internally consistent with the experimentally derived properties. These results allow predicting accurately the solubility of monazite between 25 and 300 ºC. Before these corrections, the properties for the Nd 3+ aqua ions derived from the HKF parameters resulted in up to ~1.5 orders of magnitude lower monazite solubility than determined experimentally. Here, a revision of the REE +3 aqua ions properties is necessary to accurately predict the mobility of REE in hydrothermal acidic solutions.

58 GEOSCIENCES↗

Design and simulated performance of calorimetry systems for the ECCE detector at the electron ion collider

Here, we describe the design and performance the calorimeter systems used in the ECCE detector to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapidity range from -3.7 to 3.8 and two hadronic calorimeters covering a combined range of -1.1<η<3.8. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision inclusive Higgs physics at e+e- colliders with tracking detectors and without calorimetry

A primary goal of a future e + e - collider program will be the precision measurement of Higgs boson properties. For practical reasons it is of interest to determine the minimal set of detector specifications required to reach this and other scientific goals. Here we investigate the precision obtainable for the e + e - Zh μ + μ - X inclusive cross section and the Higgs boson mass using the di-muon recoil method, considering a detector that has only an inner tracking system within a solenoidal magnetic field, surrounded by many nuclear interaction lengths of absorbing material, and an outer muon identification system. We find that the sensitivity achievable in these measurements with such a tracking detector is only marginally reduced compared to that expected for a general purpose detector with additional electromagnetic and hadronic calorimeter systems. The difference results mainly from multi-photon backgrounds that are not as easily rejected with tracking detectors. We also comment on the prospects for an analogous measurement of the e + e - → Zh → e + e - X inclusive cross section. Finally, we study searches for light scalars utilizing the di-muon recoil method, estimating the projected reach with a tracking or general purpose detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗