Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Calibrating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Measurement and calibration of non-linear shear terms in galaxy cluster fields

Introduction Galaxy cluster lensing is a powerful tool for measuring the mass of galaxy clusters, but accurate shear measurement and calibration are critical to obtaining reliable results. This study focuses on the measurement and calibration of weak lensing shears to improve mass estimates in cluster lensing. To deal with the problem, we first developed an image simulation pipeline, jedisim, which utilizes galaxy images extracted from the Hubble Space Telescope (HST) Ultra Deep Field (UDF) and the Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey (CANDELS). Methods The simulations represent realistic galaxy distributions and morphologies as input sources. The foreground halo with a Navarro–Frenk–White (NFW) profile is constructed such that the lensing signals of background galaxies can be measured by the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) Science Pipelines. By comparing the measured reduced shear g meas and the true reduced shear g true , we observe non-linearity up to g ≲ 0.6 . We fit polynomials to the data with quadratic correction adequate to g ≲ 0.4 . Meanwhile, we conduct mass estimates using the pzmassfitter code on four different clusters. Results The mass estimate results are significantly improved after applying the shear calibration derived from the present work—from 4.954 ± 0.504 × 1 0 14 M ⊙ to 10.507 ± 0.498 × 1 0 14 M ⊙ after calibration for a simulated cluster with the mass of 10 × 1 0 14 M ⊙ . In multiple cases of validation, the estimated results are all consistent with true cluster mass. Discussion This study yields the first relationship between reality and shape measurement of the LSST Science Pipelines and serves as the first step toward the overall goal of mass calibration in cluster lensing. By addressing the challenges in shear measurement and calibration, we aim to enhance the accuracy and reliability of mass estimates in galaxy cluster lensing studies.

Astronomy & Astrophysics

An upgraded frequency-selectable laser source (FLS) calibrator for CMB bandpass characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from the uncertainty in instrument bandpass calibration. Uncertainties in bandpass can limit foreground removal and spectral fitting, which are critical for inflationary and galaxy cluster measurements. CMB experiments currently use Fourier Transform Spectrometers (FTSes) to measure instrument bandpasses. However, FTS systems are currently systematics-limited, so significant improvements in bandpass measurements require novel calibrators. To this end, we developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency coupled to a system that allows for laser power attenuation. Following initial testing with the first FLS prototype, we developed an upgraded version of the calibrator with improved performance. We present the upgrades to the FLS calibrator, the characterization of the upgraded calibrator and new laser source, and plans for testing with microwave instruments in the field.

Saunders, Lauren J. [Fermilab] (ORCID:000000016367

Bayesian Calibration of Stochastic Agent Based Model via Random Forest

Agent-based models (ABM) provide an excellent framework for modeling outbreaks and interventions in epidemiology by explicitly accounting for diverse individual interactions and environments. However, these models are usually stochastic and highly parametrized, requiring precise calibration for predictive performance. When considering realistic numbers of agents and properly accounting for stochasticity, this high-dimensional calibration can be computationally prohibitive. This paper presents a random forest-based surrogate modeling technique to accelerate the evaluation of ABMs and demonstrates its use to calibrate an epidemiological ABM named CityCOVID via Markov chain Monte Carlo (MCMC). The technique is first outlined in the context of CityCOVID's quantities of interest, namely hospitalizations and deaths, by exploring dimensionality reduction via temporal decomposition with principal component analysis (PCA) and via sensitivity analysis. The calibration problem is then presented, and samples are generated to best match COVID-19 hospitalization and death numbers in Chicago from March to June in 2020. Further, these results are compared with previous approximate Bayesian calibration (IMABC) results, and their predictive performance is analyzed, showing improved performance with a reduction in computation.

60 APPLIED LIFE SCIENCES

A low-latitude, high-elevation 10Be production-rate calibration from the Rwenzori Mountains, Uganda

Cosmogenic nuclide surface-exposure dating has become a key tool in geomorphology. Robust application of the technique relies on determination of local nuclide production rates using independently dated calibration sites. However, there are few existing calibration sites in certain regions, particularly in low-latitude, high-elevation regions where cosmogenic nuclide production is theoretically more sensitive to changes in Earth's magnetic field and atmospheric conditions. We present a new cosmogenic beryllium-10 (10Be) production-rate calibration from the equatorial Rwenzori Mountains in Uganda. The calibration is based on radiocarbon dating of basal lake sediments (∼21.3 kyr BP) from Lake Mahoma (2900 m asl) and measured 10Be concentrations from boulders on the crest of a moraine which dams the lake. Our results indicate a time-integrated 10Be production rate of 15.83 ± 0.81 at/g/yr at Lake Mahoma. We then use these calibration data and two public online calculators to calculate ages for moraines in a separate Rwenzori valley for which there exists a minimum-limiting radiocarbon age constraint (∼12 kyr BP) on surficial glacial sediments. This enables us to assess the performance of different parameters used to scale production rates spatially and temporally (e.g., scaling frameworks, geomagnetic field reconstructions, atmospheric models) for surface-exposure age calculation in the region. Our results highlight the sensitivity of low-latitude cosmogenic nuclide surface-exposure ages to discrete calculation parameters, such as scaling framework or reconstructions of Earth's magnetic field, and the utility of determining production rates at sites where limiting age data exists for other nearby landforms.

Anderson, N [Dartmouth College]

A Diffusion‐Based Uncertainty Quantification Method to Advance E3SM Land Model Calibration

Abstract Calibrating land surface models and accurately quantifying their uncertainty are crucial for improving the reliability of simulations of complex environmental processes. This, in turn, advances our predictive understanding of ecosystems and supports climate‐resilient decision‐making. Traditional calibration methods, however, face challenges of high computational costs and difficulties in accurately quantifying parameter uncertainties. To address these issues, we develop a diffusion‐based uncertainty quantification (DBUQ) method. Unlike conventional generative diffusion methods, which are computationally expensive and memory‐intensive, DBUQ innovates by formulating a parameterized generative model and approximates this model through supervised learning, which enables quick generation of parameter posterior samples to quantify its uncertainty. DBUQ is effective, efficient, and general‐purpose, making it suitable for site‐specific ecosystem model calibration and broadly applicable for parameter uncertainty quantification across various earth system models. In this study, we applied DBUQ to calibrate the Energy Exascale Earth System Model land model at the Missouri Ozark AmeriFlux forest site. Results indicated that DBUQ produced accurate parameter posterior distributions similar to those from Markov Chain Monte Carlo sampling but with 30 times less computing time. This significant improvement in efficiency suggests that DBUQ can enable rapid, site‐level model calibration at a global scale, enhancing our predictive understanding of climate impacts on terrestrial ecosystems.

54 ENVIRONMENTAL SCIENCES

Galaxy cluster matter profiles - I. Self-similarity, mass calibration, and observable-mass relation validation employing cluster mass posteriors

We present a study of the weak lensing inferred matter profiles ΔΣ(R) of 698 South Pole Telescope (SPT) thermal Sunyaev-Zel’dovich effect (tSZE) selected and MCMF optically confirmed galaxy clusters in the redshift range 0.25 < z < 0.94 that have associated weak gravitational lensing shear profiles from the Dark Energy Survey (DES). Rescaling these profiles to account for the mass dependent size and the redshift dependent density produces average rescaled matter profiles ΔΣ(R/R200c)/(ρcritR200c) with a lower dispersion than the unscaled ΔΣ(R) versions, indicating a significant degree of self-similarity. Galaxy clusters from hydrodynamical simulations also exhibit matter profiles that suggest a high degree of self-similarity, with RMS variation among the average rescaled matter profiles with redshift and mass falling by a factor of approximately six and 23, respectively, compared to the unscaled average matter profiles. We employed this regularity in a new Bayesian method for weak lensing mass calibration that employs the so-called cluster mass posterior P(M200|ζ̂, λ̂, z), which describes the individual cluster masses given their tSZE (ζ̂) and optical (λ̂, z) observables. This method enables simultaneous constraints on richness λ-mass and tSZE detection significance ζ-mass relations using average rescaled cluster matter profiles. We validated the method using realistic mock datasets and present observable-mass relation constraints for the SPT×DES sample, where we constrained the amplitude, mass trend, redshift trend, and intrinsic scatter. Our observable-mass relation results are in agreement with the mass calibration derived from the recent cosmological analysis of the SPT×DES data based on a cluster-by-cluster lensing calibration. Our new mass calibration technique offers a higher efficiency when compared to the single cluster calibration technique. We present new validation tests of the observable-mass relation that indicate the underlying power-law form and scatter are adequate to describe the real cluster sample but that also suggest a redshift variation in the intrinsic scatter of the λ-mass relation may offer a better description. In addition, the average rescaled matter profiles offer high signal-to-noise ratio (S/N) constraints on the shape of real cluster matter profiles, which are in good agreement with available hydrodynamical ΛCDM simulations. This high S/N profile contains information about baryon feedback, the collisional nature of dark matter, and potential deviations from general relativity.Key words: gravitational lensing: weak / galaxies: clusters: general / large-scale structure of Universe

79 ASTRONOMY AND ASTROPHYSICS

PMT calibration for the JSNS^2-II far detector with an embedded LED system

The JSNS^2-II (the second phase of JSNS^2, J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment aimed at searching for sterile neutrinos. Here, this experiment has entered its second phase, employing two liquid scintillator detectors located at near and far positions from the neutrino source. Recently, the far detector of the experiment has been completed and is currently in the calibration phase. The following properties of all functioning Photo-Multiplier-Tubes (PMTs) to detect the neutrino events in the far detector have been calibrated: PMT gain, its dependence of supplied High Voltage (HV), Peak-to-Valley (PV), and signal timing. This paper presents a detailed description of the calibration process utilizing the LED system. The LED system of the far detector uses two Ultra-Violet (UV) LEDs, which are effective in calibrating all of the PMTs at once. The UV light is converted into the visible light wavelengths inside liquid scintillator via the wavelength shifters, providing pseudo-isotropic light. To achieve a good energy resolution for physics events, a relative gain adjustment of up to 10% is required for all functioning PMTs. This will be achieved using the HV curves measured and the results of the LED calibration. The Peak-to-Valley (PV) ratio values, which distinguish the single photo-electron signal from the pedestal, are similar to those from the production company. Additionally, the precision of the PMT signal timing is measured to be 2.1 ns. This meets the event reconstruction requirement of 10 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Photon calibration techniques for high resolution cryogenic detectors

Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector’s resolution is larger than the energy of a single photon, a calibration is normally derived using Poisson statistics. In this paper, we clarify the assumptions implicit in this calibration method, before considering how a more realistic model of a detector’s performance will violate these assumptions, biasing the calibration. Lastly, we judge the individual impact of specific detector parameters on our calibration, and conclude with discussion of both the limits of our calculations and the implications for state-of-the art detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

CaliQEC: In-situ Qubit Calibration for Surface Code Quantum Error Correction

Quantum Error Correction (QEC) is essential for fault-tolerant, large-scale quantum computation. However, error drift in qubits undermines QEC performance during long computations, necessitating frequent calibration. Conventional calibration methods disrupt quantum states, requiring system downtime and rendering in situ calibration impractical. To address this challenge, we propose QECali, a novel framework that enables in situ calibration for surface codes. Our evaluation demonstrates that QECali introduces modest qubit overhead and negligible increases in execution time, offering the first practical solution for in situ calibration in surface code based quantum computation.

Fang, Xiang [University of California, Santa Barba

XCal: model-based approach to X-ray CT spectral calibration

Transmission X-ray computed tomography (CT) is widely used to quantitatively reconstruct 3D objects composed of multiple materials. However, accurate CT reconstruction requires the system to be calibrated to account for the effective X-ray spectrum. Unfortunately, measurement of the effective spectrum is ill-posed, and existing calibration methods require that the system be recalibrated when the system parameters are changed. In this paper, we propose XCal, a multi-energy model-based spectral calibration approach for X-ray CT. The XCal approach models the effective spectrum using a separable physics-based model of the CT system. The model parameters are then estimated by fitting calibration data with known objects at multiple energies. An important advantage of XCal is that it allows the user to change scanner settings, such as the source voltage or X-ray filters, without the need for recalibration. Evaluations on simulated and measured datasets demonstrate that XCal significantly improves the accuracy of the estimated spectrum as compared to existing calibration methods.

Li, Wenrui [Purdue Univ., West Lafayette, IN (Unit

Automated Calibration System for Beam Current Monitor

The Beam Current Monitor (BCM) measures the instantaneous current in a beam. This work aims to develop an automated calibration system for the BCM to address the need for calibration without interrupting beam operation. We strive to create a synchronous calibration method integrated into the master timeline by utilizing the pulsed nature of synchrotrons to run calibration pulses during inter-pulse gaps. This improvement should enhance operational efficiency, ensure safe operation, and help mitigate beam loss, all by enabling intermittent calibration during the operation of the accelerator. This is accomplished by developing a Python program that interfaces with a Keithley 6221 DC and AC source and a Keithley 2182A Nanovoltmeter. The program configures both of these devices to perform a selected mode of the current sweep, allows for the initiation of the current sweep, collects the measured voltage data from the 2182A, stores the collected data to the computer in a CSV file, and graphs the collected data.

Haller, James

Calibration of Al7075 with Plate-Puncture Predictions

The following details calibration of a material model for Al7075-T6511. This aluminum alloy is commonly used across a host of engineering applications. Owing to its widespread prevalence, there is great benefit in improving simulation predictions for this alloy. In the present effort, a calibration is performed of its elastic-plastic response accounting for both rate and temperature dependence. The calibration is informed by a series of tests that include specimens of different geometries tested at different rates and temperatures. All specimens are derived from the same barstock, 3.5 inches in diameter. The fitted model itself uses an anisotropic, Hill yield surface coupled with a Johnson-Cook hardening model. Failure predictions are had by means of a modified Wilkins failure criterion. Following calibration of the material model, a validation exercise is performed against platepuncture experiments. These experiments include multiple probe shapes, probe diameters, and plate thicknesses. The puncture experiments are replicated in simulation with mesh studies performed to assess uncertainty. Key quantities of interest, notably the absorbed energy up to failure, are compared between simulation and experiment providing a means to assess the suitability of the calibration in puncture simulations.

36 MATERIALS SCIENCE

Performance and automatic calibration scheme of the waveform sampler in the ETROC2 ASIC chip

The waveform sampler in the CMS ETROC2 chip for LGAD gain aging monitoring is a 2.56-GS/s 12-bit 8x-Interleaved ADC that consists of a coarse SAR stage, and a fine stage. This architecture delivers high performance on a relatively modest 65 nm process, while requires finding up to 24 calibration constants through calibration. We developed an automatic calibration method using charge injection test data. After calibration, the baseline random error is reduced by a factor of 2.5–3 compared to the default calibration, and a 5% charge measurement precision is achieved in 15 fC charge injection tests.

Fu, Tao [Unlisted, US]

SBND Calibration

The Short-Baseline Near Detector (SBND) is a 112-ton liquid argon time projection chamber (LArTPC) serving as the near detector of the Short-Baseline Neutrino Program at Fermilab. SBND aims to make precise measurements of neutrino-argon interactions, necessitating an extensive calibration program for the LArTPC to ensure precision/accuracy in these measurements. This talk describes the use of cosmogenic, radiogenic, and neutrino interaction activity with both Monte Carlo simulation and data in calibrating the SBND subsystems of the Time Projection Chamber, Photon Detection System, and Cosmic Ray Tagger. We will highlight some of SBND's first calibration results, including electronics calibrations, measurement of the electron lifetime, shower calibration, and studies of space charge effects in the detector.

Oh, Sungbin [Fermilab]

Photon Detection System Calibration for DUNE

Photon Detection System Calibration for DUNE Not scheduled 20m Conference Center (University of California, Irvine) Poster New Technologies for Neutrino Physics Poster session Speaker Denis Torres (South Dakota School of Mines and Technology) Description The Deep Underground Neutrino Experiment (DUNE) is a long baseline neutrino oscillation experiment that relies on a precise Photon Detection System (PDS) to provide accurate timing information, enhance sensitivity to low-energy and non-beam events, and support detector performance studies in liquid argon time projection chambers. Achieving these goals requires a well-understood and stable optical calibration strategy that operates reliably under cryogenic conditions. In this poster, I will present PDS calibration studies performed in ProtoDUNE, focusing on the characterization of the ultraviolet (UV) light calibration system and key optical components in the light-delivery chain. I will discuss measurements of optical fiber transmission, SMA-to-SMA connector and feedthrough interface losses, and diffuser assemblies, emphasizing wavelength dependence, attenuation, and performance under cryogenic thermal cycling and stability tests. These studies provide quantitative inputs for understanding light transport, uniformity, and long-term reliability of the PDS in large-scale liquid argon detectors, and they directly inform calibration strategies for the DUNE Far Detector.

Torres Muñoz, Denis [South Dakota Sch. Mines Tech.

Calibration of the Mu2e momentum scale using $\pi^{+}\rightarrow e^{+}\nu_{e}$ decays

The Mu2e experiment at Fermilab will search for the neutrinoless muon-to-electron conversion in the nuclear field by stopping negative muons on an Al target. The experimental signature of $\mu^{-}$ to $e^{-}$ conversion on Al is the observation of mono-energetic electrons with 104.97 MeV produced by the lepton violating reaction. Rejection of one of the most important experimental backgrounds coming from muon Decays-In-Orbit requires a momentum resolution $<1\%$ FWHM and a momentum scale calibrated to an accuracy of better than $0.1\%$ or $0.1$ MeV at an electron energy of $\sim$100 MeV. Among other momentum scale calibration techniques, the collaboration is considering using 68.9 MeV positrons from decays of stopped positive pions. This calibration measurement has a significant background dominated by the muon decays-in-flight affecting the calibration accuracy. In this article, we discuss the momentum calibration measurement results.

Tripathy, Sridhar [UC, Davis (main)] (ORCID:000000

RTN-117: Image Calibration and Instrument Signal Removal for the First Year of the LSST

The NSF-DOE Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) requires calibration products that provide uniform, stable, and accurate photometric and astrometric performance across the 3.2 gigapixel focal plane and throughout the 10-year survey. This paper details the algorithms and workflows used to produce instrument calibrations and remove instrumental artifacts for Data Preview 2 (DP2)---the first end-to-end processing demonstration using on-sky data with the LSST Camera (LSSTCam). We describe the verification, acceptance, and certification framework used to assess calibration quality and quantify residual systematics. We show baseline metrics on calibrated science images to evaluate the robustness of the calibration and instrument signature removal (ISR) data processing pipelines for DP2. Finally, we summarize the known limitations observed in DP2 production and outline expected algorithmic improvements for the first public LSST data release (Data Release~1, DR1).

79 ASTRONOMY AND ASTROPHYSICS

Automated Calibration for Rapid Optical Spectroscopy Sensor Development for Online Monitoring

An automated platform has been developed to assist researchers in the rapid development of optical spectroscopy sensors to quantify species from spectral data. This platform performs calibration and validation measurements simultaneously. Real-time, in situ monitoring of complex systems through optical spectroscopy has been shown to be a useful tool; however, building calibration models requires development time, which can be a limiting factor in the case of radiological or otherwise hazardous systems. While calibration time can be reduced through optimized design of experiments, this study approached the challenge differently through automation. The ATLAS (Automated Transient Learning for Applied Sensors) platform used pneumatic control of stock solutions to cycle flow profiles through desired calibration concentrations for multivariate model construction. Additionally, the transients between desired concentrations based on flow calculations were used as validation measurements to understand model predictive capabilities. This automated approach yielded an incredible 76% reduction in model development time and a 60% reduction in sample volume versus estimated manual sample preparation and static measurements. The ATLAS system was demonstrated on two systems: a three-lanthanide system with Pr/Nd/Ho representing a use case with significant overlap or interference between analyte signatures and an alternate system containing Pr/Nd/Ni to demonstrate a use case in which broad-band corrosion species signatures interfered with more distinct lanthanide absorbance profiles. Both systems resulted in strong model prediction performance (RMSEP < 9%). Lastly, ATLAS was demonstrated as a tool to simulate process monitoring scenarios (e.g., column separation) in which models can be further optimized to account for day-to-day changes as necessary (e.g., baseline correction). Ultimately, ATLAS offers a vital tool to rapidly screen monitoring methods, investigate sensor fusion, and explore more complex systems (i.e., larger numbers of species).

47 OTHER INSTRUMENTATION