Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CUORE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

48 records · Page 3

A CUPID Li2100MoO4 scintillating bolometer tested in the CROSS underground facility

A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2\beta$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $\gamma$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$\sigma$) between $\gamma$($\beta$) and $\alpha$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $\mu$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2\beta$ decay in CROSS and CUPID projects.

47 OTHER INSTRUMENTATION↗

Muon track reconstruction in a segmented bolometric array using multi-objective optimization

Recent advances in segmented solid-state detector arrays for rare-event searches have allowed the technology to approach the ton-scale in detector mass and the scale of meters in size. Often focused around searches for neutrinoless double-beta decay or direct dark matter detection, such experiments also have the capability to search for exotic particles that leave track-like signatures across their volume. However, the segmented nature of such detector arrays often sets the spatial resolution and makes the problem of reconstructing track-like paths non-trivial. Here, in this paper, we present an algorithm that improves reconstruction of track-like events in segmented detectors using multi-objective optimization — a computational technique that optimizes more than one cost function at a time without specifying a quantitative weighting between them. Such a technique allows the reconstruction of tracks through a detector and the determination of path-lengths through individual elements. When combined with the reconstructed energy depositions in each element this allows for a calculation of the stopping power of track-like particles and opens the door to searches for particles with abnormal stopping power like monopoles or lightly-ionizing particles (LIPs). Results are presented which evaluate the precision of the reconstruction tools as they currently stand against Monte Carlo generated data. The algorithm is presented in the context of the CUORE experiment, but has applications to other segmented calorimeter detectors.

47 OTHER INSTRUMENTATION↗

Half-Life and Precision Shape Measurement of the 2⁢𝜈⁢𝛽⁢𝛽 Decay of 130 Te

Here, we present a new measurement of the 2⁢𝜈⁢𝛽⁢𝛽 half-life of 130 Te (𝑇$^{2⁢𝜈}_{1/2}$) using the first complete model of the CUORE data, based on 1038 kg yr of collected exposure. Thanks to optimized data selection, we achieve a factor of two improvement in precision, obtaining 𝑇$^{2⁢𝜈}_{1/2}$ = (9.32⁢$^{+0.05}_{−0.04}$⁢stat⁢ $^{+0.07}_{−0.07}$⁢syst)×10 20 yr. The signal-to-background ratio is increased by 70% compared to our previous results, enabling the first application of the improved 2⁢𝜈⁢𝛽⁢𝛽 formalism to 130 Te . Within this framework, we determine a credibility interval for the effective axial coupling in the nuclear medium as a function of nuclear matrix elements. We also extract values for the higher-order nuclear matrix element ratios: second-to-first and third-to-first. The second-to-first ratio agrees with nuclear model predictions, while the third-to-first ratio deviates from theoretical expectations. These findings provide essential tests of nuclear models and key inputs for future 0⁢𝜈⁢𝛽⁢𝛽 searches.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Readout Noise of Digital Frequency Multiplexed TES Detectors for CUPID

The superconducting transition-edge sensor (TES) detectors have been the standard in cosmic microwave background (CMB) experiments for almost two decades and are now being adapted for use in nuclear physics, such as neutrinoless double beta decay searches. In this article, we focus on a new high-bandwidth frequency multiplexed TES readout system developed for CUPID, a neutrinoless double beta decay experiment that will replace CUORE. In order to achieve the high energy resolution requirements for CUPID, the readout noise of the system must be kept to a minimum. Low TES operating resistance and long wiring between the readout SQUID and the warm electronics are needed for CUPID, prompting a careful consideration of the design parameters of this application of frequency multiplexing. In this work, we characterize the readout noise of the newly designed frequency multiplexed TES readout system for CUPID and construct a noise model to understand it. Here, we find that current sharing between the SQUID coil impedance and other branches of the circuit, as well as the long output wiring, worsen the readout noise of the system. To meet noise requirements, a SQUID with a low input inductance, high transimpedance, and/or low dynamic impedance is needed, and the wiring capacitance should be kept as small as possible. Alternatively, the option of adding a cryogenic low-noise amplifier at the output of the SQUID should be explored.

CUPID↗

Optimization of the first CUPID detector module

CUPID will be a next generation experiment searching for the neutrinoless double β decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li 2 100 MoO 4 crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of α particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 ± 0.2) keV FWHM at the Q-value of 100 Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors’ mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an α particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving the performance of cryogenic calorimeters with nonlinear multivariate noise cancellation algorithms

Abstract State-of-the-art physics experiments require high-resolution, low-noise, and low-threshold detectors to achieve competitive scientific results. However, experimental environments invariably introduce sources of noise, such as electrical interference or microphonics. The sources of this environmental noise can often be monitored by adding specially designed “auxiliary devices” (e.g. microphones, accelerometers, seismometers, magnetometers, and antennae). A model can then be constructed to predict the detector noise based on the auxiliary device information, which can then be subtracted from the true detector signal. Here, we present a multivariate noise cancellation algorithm which can be used in a variety of settings to improve the performance of detectors using multiple auxiliary devices. To validate this approach, we apply it to simulated data to remove noise due to electromagnetic interference and microphonic vibrations. We then employ the algorithm to a cryogenic light detector in the laboratory and show an improvement in the detector performance. Finally, we motivate the use of nonlinear terms to better model vibrational contributions to the noise in thermal detectors. We show a further improvement in the performance of a particular channel of the CUORE detector when using the nonlinear algorithm in combination with optimal filtering techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivity of the CUPID experiment to $0\nu \beta \beta$ decay of 100 Mo

CUPID is a next-generation bolometric experiment to search for neutrinoless double-beta decay ($0\nu \beta \beta$ ) of 100 Mo using Li 2 MoO 4 scintillating crystals. It will operate 1596 crystals at ~10 mK in the CUORE cryostat at the Laboratori Nazionali del Gran Sasso in Italy. Each crystal will be facing two Ge-based bolometric light detectors for α rejection. We compute the discovery and the exclusion sensitivity of CUPID to $0\nu \beta \beta$ in a Frequentist and a Bayesian framework. This computation is done numerically based on pseudo-experiments. For the CUPID baseline scenario, with a background and an energy resolution of 1.0 x 10 –4 counts/keV/kg/yr and 5 keV FWHM at the Q-value, respectively, this results in a Bayesian exclusion sensitivity (90% c.i.) of $\hat{T}_{1/2} > 1.6 \times 10^{27} \ \textrm{yr}$, corresponding to the effective Majorana neutrino mass of $\hat{m}_{\beta \beta } < \ 9.6$ – 28 meV. The Frequentist discovery sensitivity (3σ ) is $\hat{T}_{1/2}= 1.0 \times 10^{27} \ \textrm{yr}$, corresponding to $\hat{m}_{\beta \beta }= \ 12$ – 36 meV.

Alfonso, K. [Virginia Polytechnic Institute and St↗

R&D Toward CUPID, a Tonne-Scale Bolometric 0vBB Experiment (Final Report)

This award supported the construction of infrastructure at MIT to test components for the future CUPID experiment. CUPID is the CUORE Upgrade with Particle ID. It uses Lithium molybdate crystals instrumented as scintillating bolometers to search for the neutrinoless double-beta decay of 100 Mo. A bolometer is a detector which uses the change in temperature of a crystal due to the passage of charged particles through the crystal to detect the particle. A scintillating bolometer uses a scintillating crystal as the primary bolometer and a germanium wafer as a secondary light-collecting bolometer. The charged particle therefore creates a heat and light signal, the ratio of these signals allows us to distinguish signal from background.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

R&D Towards CUPID, a Ton-Scale Bolometric 0νββ Experiment

CUPID, the CUORE Upgrade with Particle IDentification, is a next-generation experiment to search for neutrinoless double beta (0νββ) decay and other rare events using scintillating bolometers with 100 Mo. This award supported simulation and design work on the muon tagger system for CUPID as well the development of a plan and protocol for the irradiation and fabrication of the NTD thermal sensors for CUPID.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energy density driven ultrafast electronic excitations in a cuprate superconductor

Controlling nonequilibrium dynamics in quantum materials requires ultrafast probes with spectral selectivity. We report femtosecond reflectivity measurements on the cuprate superconductor Bi 2⁢ Sr 2⁢ CaCu 2 ⁢O 8+𝛿 using free-electron laser extreme-ultraviolet (23.5–177 eV) and near-infrared (1.5 eV) pump pulses. EUV pulses access deep electronic states, while NIR light excites valence-band transitions. Despite these distinct channels, both schemes produce nearly identical dynamics: above 𝑇 𝑐 , excitations relax through fast (100–300 fs) and slower (1–5 ps) channels; below 𝑇 𝑐 , a delayed component signals quasiparticle recombination and condensate recovery. We find that when electronic excitations are involved, the ultrafast response is governed mainly by absorbed energy rather than by the microscopic nature of the excitation. In contrast, bosonic driving in the THz or midinfrared produces qualitatively different dynamics. By demonstrating that EUV excitation of a correlated superconductor yields macroscopic dynamics converging with those from optical pumping, this work defines a new experimental paradigm: FEL pulses at core-level energies provide a powerful means to probe and control nonequilibrium electronic states in quantum materials on their intrinsic femtosecond timescales. This establishes FEL-based EUV pumping as a new capability for ultrafast materials science, opening routes toward soft x-ray and attosecond studies of correlated dynamics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Selective electron-phonon coupling strength from nonequilibrium optical spectroscopy: The case of MgB 2

The coupling between quasiparticles and bosonic excitations rules the energy transfer pathways in condensed matter systems. The possibility of inferring the strength of specific coupling channels from their characteristic timescales measured in nonequilibrium experiments is still an open question. Here, in this study, we investigate MgB 2 , in which conventional superconductivity at temperatures as high as 39 K is mediated by the strong coupling between the conduction electrons and the 𝐸 2⁢𝑔 phonon mode. By means of broadband time-resolved optical spectroscopy, we show that this selective electron-phonon coupling dictates the nonequilibrium optical response of MgB 2 at early times (<100 fs) after photoexcitation. Furthermore, based on an effective temperature model analysis, we estimate its contribution to the total electron-boson coupling function extracted from complementary equilibrium spectroscopy approaches, namely, optical reflectivity and angle-resolved photoemission spectroscopy. The coupling strength with the 𝐸 2⁢𝑔 phonon modes is thus estimated to be 𝜆 ≃ 0.56, which is approximately half of the total coupling constant, in agreement with 𝑎𝑏 initio calculations from the literature. As a benchmark, broadband time-resolved optical spectroscopy is performed also on the isostructural and nonsuperconducting compound AlB 2 , showing that the nonequilibrium optical response relaxes on a slower timescale due to the lack of strongly coupled phonon modes. Our findings demonstrate the possibility to resolve and quantify selective electron-phonon coupling from nonequilibrium optical spectroscopy.

Mor, Selene [Università Cattolica del Sacro Cuore,↗