Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Virtual Volumes

SAND2022-14692 O Virtual Volumes is a CAD2VR plugin that gives users a powerful and intuitive way of exploring volumetric data in a three-dimensional (3D) virtual reality (VR) environment. It enables viewing of and interaction with volumetric and voxel data derived from sources such computed tomography (CT) scans. Current 2D software solutions for viewing CT scans and other volumetric data forces the user to look through "slices" of their data across anatomical planes. In Virtual Volumes, the user can intuitively interact, scale, crop, colorize, and threshold their data in a 3D VR environment. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Krukar, JohnA.↗

Identifying the Accuracy of Surface Roughness for Metal Additive Manufacturing Parts Captured with Computed Tomography Scanning

Conventional surface roughness measurement techniques require direct access to internal surfaces, often necessitating destructive sectioning of test articles. Computed tomography (CT) offers a non-destructive alternative for internal surface characterization, but its application in metrology remains unstandardized and sensitive to machine resolution and operator technique. This study investigates the feasibility of using CT scanning to quantify areal surface roughness in metal AM heat exchanger tubes with three distinct internal geometries: ribbed, discrete W, and featureless. CT-derived surface parameters were extracted using custom Python scripts and compared to measurements obtained from a focus variation microscope calibrated against a known standard. Results show that CT-based roughness measurements closely matched microscope values for the discrete W specimen, deviations between CT and microscope measurements were minimal—less than 1 µm—indicating reliable reconstruction. In contrast, the ribbed and featureless specimens, with lower roughness values showed greater discrepancies. The findings suggest that CT scanning can be a viable non-destructive metrology tool for AM parts with surface roughness above approximately 8 µm. For smoother surfaces, current CT capabilities may not provide sufficient accuracy, highlighting the need for resolution-aware workflows and further standardization in CT-based surface metrology.

36 MATERIALS SCIENCE↗

CT and Scanning Data of the KGS Wellington 1-32 CarbonSAFE Core

Data described in the NETL Technical Report Series "Computed Tomography Scanning and Geophysical Measurements of the Wellington 1-32 Core", including processed and raw CT and measurements from NETL's multi-sensor core logger. Paronish, T.; Schmitt, R.; Mitchell, N; Brown, S; Crandall, D.; Moore, J.; Hasiuk, F.; Potter, N.; Holubnyak, Y.E. Computed Tomography Scanning and Geophysical Measurements of the Wellington 1-32 Core; DOE.NETL-2021.2882; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2022; p 108. DOI: https://doi.org/10.2172/1894355 https://edx.netl.doe.gov/dataset/computed-tomography-scanning-and-geophysical-measurements-of-the-wellington-1-32-core

CarbonSafe↗

Impacts of Superalloys on the Surface Quality of Additively Manufactured Channels

Abstract Gas turbines feature many components that require superalloys capable of handling extreme thermal environments. Increasing the selection of materials available for these components is important to their use in these extremely high-temperature environments. This study investigated two recently developed materials intended to be used for additive manufacturing (AM), with one superalloy based on cobalt and the other on nickel. Sets of four test coupons were built using the materials, in addition to the commonly used Inconel-718, on multiple laser powder bed fusion machines. Several build conditions were varied between coupon sets, including coupon orientation, contour settings, and upskin and downskin treatment. Each set of test coupons featured four unique cooling designs to explore how different cooling technologies would be impacted by the variations in build conditions. After being built, coupons were computed tomography (CT) scanned to determine accuracy to design intent and quantify the surface roughness. The CT scans indicated that horizontally built test coupons had a significantly higher deviation from design intent and higher surface roughness than those built vertically. Results also indicated that the cobalt-based alloy consistently had a smoother surface quality with lower surface roughness compared to the nickel-based alloy. After geometric characterization, the cooling performance of the test coupons was measured experimentally. Pressure losses were found to correlate with increases in surface roughness; however, in some cases, the convective heat transfer did not increase proportionally to the pressure loss as a result of surface features significantly blocking the flow without proportionally increasing convective heat transfer.

Engineering↗

COBRA:COMPUTED-TOMOGRAPHY BASED RANDOM-FIELD APPROXIMATION

SF-25-115 COBRA (COmputed-tomography Based Random-field Approximation) is a Python application for generating statistically equivalent random fields from CT-scan imagery. It leverages Karhunen–Loève expansions to model microstructural variability, enabling users to: Preprocess CT scans (filtering and Gaussian transformation); Fit covariance kernels fromempirical data; Solve eigenproblems to obtain KL modes; Sample random fields onsistent with fitted statistics; Postprocess samples back into the physical domain.

Hu, Tianchen↗

Dataset documenting reaction-induced changes to five fractured foamed wellbore cement cores during CO2 fluid flow

This dataset consists of reconstructed CT scans for four fractured foamed cement cores, generated in the lab using Portland Class H cement, and associated processed data. The cements were exposed to reactive brines, and CT scans were take at different time points through the experiment. The CT imaging allows for the tracking of dissolution-induced changes to fracture morphology, as well as alteration and dissolution in the cement matrix.

Computed Tomography↗

Rapid Prototyping Integrated With Nondestructive Evaluation and Finite Element Analysis

Most reverse engineering approaches involve imaging or digitizing an object then creating a computerized reconstruction that can be integrated, in three dimensions, into a particular design environment. Rapid prototyping (RP) refers to the practical ability to build high-quality physical prototypes directly from computer aided design (CAD) files. Using rapid prototyping, full-scale models or patterns can be built using a variety of materials in a fraction of the time required by more traditional prototyping techniques (refs. 1 and 2). Many software packages have been developed and are being designed to tackle the reverse engineering and rapid prototyping issues just mentioned. For example, image processing and three-dimensional reconstruction visualization software such as Velocity2 (ref. 3) are being used to carry out the construction process of three-dimensional volume models and the subsequent generation of a stereolithography file that is suitable for CAD applications. Producing three-dimensional models of objects from computed tomography (CT) scans is becoming a valuable nondestructive evaluation methodology (ref. 4). Real components can be rendered and subjected to temperature and stress tests using structural engineering software codes. For this to be achieved, accurate high-resolution images have to be obtained via CT scans and then processed, converted into a traditional file format, and translated into finite element models. Prototyping a three-dimensional volume of a composite structure by reading in a series of two-dimensional images generated via CT and by using and integrating commercial software (e.g. Velocity2, MSC/PATRAN (ref. 5), and Hypermesh (ref. 6)) is being applied successfully at the NASA Glenn Research Center. The building process from structural modeling to the analysis level is outlined in reference 7. Subsequently, a stress analysis of a composite cooling panel under combined thermomechanical loading conditions was performed to validate this process.

Abdul-Aziz, Ali↗

Computer Tomography 3-D Imaging of the Metal Deformation Flow Path in Friction Stir Welding

In friction stir welding, a rotating threaded pin tool is inserted into a weld seam and literally stirs the edges of the seam together. This solid-state technique has been successfully used in the joining of materials that are difficult to fusion weld such as aluminum alloys. To determine optimal processing parameters for producing a defect free weld, a better understanding of the resulting metal deformation flow path is required. Marker studies are the principal method of studying the metal deformation flow path around the FSW pin tool. In our study, we have used computed tomography (CT) scans to reveal the flow pattern of a lead wire embedded in a FSW weld seam. At the welding temperature of aluminum, the lead becomes molten and thus tracks the aluminum deformation flow paths in a unique 3-dimensional manner. CT scanning is a convenient and comprehensive way of collecting and displaying tracer data. It marks an advance over previous more tedious and ambiguous radiographic/metallographic data collection methods.

Schneider, Judy↗

New approaches to virtual environment surgery

This research focused on two main problems: 1) low cost, high fidelity stereoscopic imaging of complex tissues and organs; and 2) virtual cutting of tissue. A further objective was to develop these images and virtual tissue cutting methods for use in a telemedicine project that would connect remote sites using the Next Generation Internet. For goal one we used a CT scan of a human heart, a desktop PC with an OpenGL graphics accelerator card, and LCD stereoscopic glasses. Use of multiresolution meshes ranging from approximately 1,000,000 to 20,000 polygons speeded interactive rendering rates enormously while retaining general topography of the dataset. For goal two, we used a CT scan of an infant skull with premature closure of the right coronal suture, a Silicon Graphics Onyx workstation, a Fakespace Immersive WorkBench and CrystalEyes LCD glasses. The high fidelity mesh of the skull was reduced from one million to 50,000 polygons. The cut path was automatically calculated as the shortest distance along the mesh between a small number of hand selected vertices. The region outlined by the cut path was then separated from the skull and translated/rotated to assume a new position. The results indicate that widespread high fidelity imaging in virtual environment is possible using ordinary PC capabilities if appropriate mesh reduction methods are employed. The software cutting tool is applicable to heart and other organs for surgery planning, for training surgeons in a virtual environment, and for telemedicine purposes.

NASA Discipline Neuroscience↗

Dose Fractionation During Puberty Is More Detrimental to Mammary Gland Development Than an Equivalent Acute Dose of Radiation Exposure

Computed tomographic (CT) scans in adolescents have increased dramatically in recent years. However, the effects of cumulative low-dose exposures on the development of radiation sensitive organs, such as the mammary gland, is unknown. The purpose of this work was to define the effects of dose rate on mammary organ formation during puberty, an especially sensitive window in mammary development. We used a fractionated low-dose x-ray exposure to mimic multiple higher dose CT scans, and we hypothesized that fractionated exposure would have less of an effect on the number of mammary gland defects compared with an acute exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of damage processes in Montney siltstone under triaxial compression using acoustic emission and diagnostic imaging

SUMMARY Crack nucleation and rock failure processes in a fine-grained siltstone (Montney Formation) under triaxial compression are investigated using combined diagnostic techniques, including ultrasonic-wave measurement, acoustic-emission (AE) monitoring, computed tomography (CT) scanning, and thin-section imaging. The sample displays a weak-to-moderate inherent seismic anisotropy and noticeable stress-induced anisotropy prior to failure. No AE event was detected until the applied axial stress reached 95 per cent of the peak value. The signal-to-noise ratio is relatively low, however, and detectable AE events are more diffuse than those observed in highly brittle rocks. The AE locations correlate with a shear fracture zone imaged by CT scanning. AE moment-tensor analysis reveals that events with larger relative magnitudes are characterized by high volumetric (tensile or compressive) components, and the initiation of the failure zone is dominated by combined shear-tensile (ST) failure. Stress inversion of the AE events with high tensile components is in good agreement with the known applied stress. Microscopic imaging of thin sections from the failed sample shows that the failure zone is an en echelon structure consisting of a major fracture with branching micro and minor cracks. This failure mechanism is consistent with a ST source mechanism and is interpreted to be associated with the fine granular structure and mineral composition of Montney siltstone.

Jia, Suzie Q. (ORCID:0000000326496190)↗

Dynamic fracture of glass fiber-reinforced ductile polymer matrix composites and loading rate effect

Here, the dynamic fracture of S-2 glass fiber-reinforced polymer matrix composites (FRPMCs) was investigated in this study. The matrix ductility was improved by a recently developed network topology modification technique via mixing partially reacted substructures (mPRS). The composite material was manufactured and characterized by micro-CT scanning and scanning electron microscopy (SEM). Dynamic single-edge notched bending (d-SENB) experiments were performed on the composites by using a modified split-Hopkinson pressure bar. Each specimen’s fracture process was visualized by ultrafast X-ray imaging. Such in-situ radiography enabled identifying the damage initiation below 50-micron scale and inspecting its propagation through the internal structures of opaque composites, thereby accurately quantifying the composites’ mechanical properties. Furthermore, the identical d-SENB experiments were designed and the digital image correlation (DIC) was employed to monitor the stress wave propagation on the composite specimens. The force and deflection measurements were modified and correlated to the physical damage processes. Besides, quasi-static SENB experiments were conducted to identify the loading rate effects on the composites’ fracture behaviors. The force and deflection history, bending stiffness, energy dissipation, and fracture toughness at different loading rates were quantified and compared. Finally, post-fracture analysis by micro-CT scanning and SEM provided physical observations on the variation of the fracture morphology by different loading rates.

42 ENGINEERING↗

Ultrasonic Testing (UT) and Computed Tomography (CT) Comparative Scanning of Proposed Additive Manufacturing Reference Standard

This report presents qualitative results of ultrasonic full matrix capture/total focusing method (FMC/TFM) scanning of two series of blocks, additively manufactured by powder bed fusion, containing a variety of internal features and structures that would not be achievable by conventional manufacturing techniques. The purpose of the first series of additively manufactured (AM) blocks was to explore the possibility of building calibration blocks for FMC/TFM ultrasonic testing (UT). It was confirmed that AM is a suitable candidate for generation of unusual and novel reflector forms, such as rotating slots, purposely embedded voids, and tapering holes, and that FMC/TFM was very capable of characterizing them. The intended use of the second series of AM blocks was as UT reference blocks to characterize the AM process quality or the interrogating UT technique. The larger block in this series was scanned from multiple faces, using multiple UT methods (conventional UT and FMC/TFM) and X-ray computed tomography for comparative purposes. The performance of each method was quantified by a metric corresponding to the detection limit of each feature, and the quantitative results are discussed.

36 MATERIALS SCIENCE↗

NDE of advanced turbine engine components and materials by computed tomography

Computed tomography (CT) is an X-ray technique that provides quantitative 3D density information of materials and components and can accurately detail spatial distributions of cracks, voids, and density variations. CT scans of ceramic materials, composites, and engine components were taken and the resulting images will be discussed. Scans were taken with two CT systems with different spatial resolution capabilities. The scans showed internal damage, density variations, and geometrical arrangement of various features in the materials and components. It was concluded that CT can play an important role in the characterization of advanced turbine engine materials and components. Future applications of this technology will be outlined.

Yancey, R. N.↗

System and method for identifying objects of interest in images based on likelihood map decluttering

An automatic threat recognition system and method is disclosed for scanning the x-ray CT image of an article to identify the objects of interest (OOIs) contained within the article, which are otherwise not always quickly apparent or discernable to an individual. The system uses a computer to receive information from two-dimensional (2D) image slices from a reconstructed computed tomography (CT) scan image and to produce a plurality of voxels for each slice of the 2D image. The computer analyzes the voxels to create a likelihood map (LM) representing likelihoods that voxels making up the CT image are associated with a material of interest (MOI). The computer further analyzes the LM to construct neighborhoods of voxels within the LM, and classifies each voxel neighborhood based on its features, thereby decluttering the LM to facilitate the process of connecting voxels of a like MOI together to form segments. The computer classifies each candidate segment based on its features, thereby identifying those segments that correspond to objects of interest.

Paglieroni, David W.↗

Management of Asymptomatic Renal Stones in Astronauts

Introduction: Management guidelines were created to screen and manage asymptomatic renal stones in U.S. astronauts. The risks for renal stone formation in astronauts due to bone loss and hypercalcuria are unknown. Astronauts have a stone risk which is about the same as commercial aviation pilots, which is about half that of the general population. However, proper management of this condition is still crucial to mitigate health and mission risks in the spaceflight environment. Methods: An extensive review of the literature and current aeromedical standards for the monitoring and management of renal stones was done. The NASA Flight Medicine Clinic's electronic medical record and Longitudinal Survey of Astronaut Health were also reviewed. Using this work, a screening and management algorithm was created that takes into consideration the unique operational environment of spaceflight. Results: Renal stone screening and management guidelines for astronauts were created based on accepted standards of care, with consideration to the environment of spaceflight. In the proposed algorithm, all astronauts will receive a yearly screening ultrasound for renal calcifications, or mineralized renal material (MRM). Any areas of MRM, 3 millimeters or larger, are considered a positive finding. Three millimeters approaches the detection limit of standard ultrasound, and several studies have shown that any stone that is 3 millimeters or less has an approximately 95 percent chance of spontaneous passage. For mission-assigned astronauts, any positive ultrasound study is followed by low-dose renal computed tomography (CT) scan, and flexible ureteroscopy if CT is positive. Other specific guidelines were also created. Discussion: The term "MRM" is used to account for small areas of calcification that may be outside the renal collecting system, and allows objectivity without otherwise constraining the diagnostic and treatment process for potentially very small calcifications of uncertain significance. However, a small asymptomatic MRM or stone within the renal collecting system may become symptomatic, and so affect launch and flight schedules, cause incapacitation during flight, and ultimately require medical evacuation. For exploration class missions, evacuation is unlikely. The new screening and management algorithm allows better management of mission risks, and will define the true incidence of renal stones in U.S. astronauts. This information will be used to refine future screening, countermeasures and treatment methods; and will also inform the needed capabilities to be flown on exploration-class missions.

Reyes, David↗

Management of Asymptomatic Renal Stones in Astronauts

Introduction: Management guidelines were created to screen and manage asymptomatic renal stones in U.S. astronauts. The risks for renal stone formation in astronauts due to bone loss and hypercalcuria are unknown. Astronauts have a stone risk which is about the same as commercial aviation pilots, which is about half that of the general population. However, proper management of this condition is still crucial to mitigate health and mission risks in the spaceflight environment. Methods: An extensive review of the literature and current aeromedical standards for the monitoring and management of renal stones was done. The NASA Flight Medicine Clinic's electronic medical record and Longitudinal Survey of Astronaut Health were also reviewed. Using this work, a screening and management algorithm was created that takes into consideration the unique operational environment of spaceflight. Results: Renal stone screening and management guidelines for astronauts were created based on accepted standards of care, with consideration to the environment of spaceflight. In the proposed algorithm, all astronauts will receive a yearly screening ultrasound for renal calcifications, or mineralized renal material (MRM). Any areas of MRM, 3 millimeters or larger, are considered a positive finding. Three millimeters approaches the detection limit of standard ultrasound, and several studies have shown that any stone that is 3 millimeters or less has an approximately 95 percent chance of spontaneous passage. For mission-assigned astronauts, any positive ultrasound study is followed by low-dose renal computed tomography (CT) scan, and flexible ureteroscopy if CT is positive. Other specific guidelines were also created. Discussion: The term "MRM" is used to account for small areas of calcification that may be outside the renal collecting system, and allows objectivity without otherwise constraining the diagnostic and treatment process for potentially very small calcifications of uncertain significance. However, a small asymptomatic MRM or stone within the renal collecting system may become symptomatic, and so affect launch and flight schedules, cause incapacitation during flight, and ultimately require medical evacuation. For exploration class missions, evacuation is unlikely. The new screening and management algorithm allows better management of mission risks, and will define the true incidence of renal stones in U.S. astronauts. This information will be used to refine future screening, countermeasures and treatment methods; and will also inform the needed capabilities to be flown on exploration-class missions.

Reyes, David↗