Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

ML-based Micro-CT SOFC Microstructure Models (from Kent 2026 Microstructural Augmentation paper)

Overview -------------------------- This repository contains datasets from the manuscript **"Enhanced Generalizability to Deep-Learning Quantification of 3D Microstructural Characteristics through Microstructurally Aware Augmentation of Scarce Data"** (*William F. Kent, Rochan Bajpai, Rachel C. Kurchin, William K. Epting, Harry W. Abernathy, Paul A. Salvador. Submitted 2026*). The methods are also described in the dissertation **Data Intensive Analysis of Solid Oxide Cell Microstructures** (*Doctoral dissertation, Carnegie Mellon University, 2025*). The datasets here are trained convolutional neural network (CNN) models for predicting key microstructural properties of solid oxide cell (SOC) electrodes from low-res, 2-channel 3D images, as well as some helpful code. The parameters for input images are provided in the paper. Sample data is provided in the file `Combined_anode_aug_dual_1k_examples` - that particular data was used to train `anode_all_aug.pth` and will work most accurately with that model. Please familiarize yourself with all caveats on accuracy and applicability, as detailed in the associated paper. Usage -------------------------- The basic usage is as follows, assuming `model_fn` is the path to the .pth file, and `X` is 2-channel input image(s) of the proper dimensions (either one image of shape `[2,12,24,24]`, or a batch of N input images of shape `[N,2,12,24,24]`): from CNN_inferencer import load_model_for_inference model = load_model_for_inference(model_fn) y_predicted = model(X) The model object automatically handles input scaling and output de-scaling based on the way the models were trained - in other words, pass in a 2-channel micro-CT image, and it will output microstructural property values in real units. ## Other model object attributes Note that model has useful attributes other than its forward pass model(X). * `model.output_descaler` - returns the output descaler object. Model does the de-scaling when generating inferences, but you may want to re-use this de-scaler on other values to e.g. compare predictions to ground truth from already-scaled training data. * `model.prop_names` - Gives the property names of the predicted y values, in order. Only exists if there's an output scaler as part of the model object, which there will be in the models provided here. ## Usage with sample data Here is a short script to use with the included sample data. from CNN_inferencer import display_predictions, load_model_for_inference, calculate_mape, parity_plot import h5py import numpy as np model_fn = 'anode_all_aug.pth' data_fn = 'Combined_anode_aug_dual_1k_examples.h5' N_samples = 200 figure_outdir = '.' model = load_model_for_inference(model_fn) with h5py.File(data_fn,'r') as f: XX = f['X'] #These are the 2-channel 3D images yy = f['y'] #These are the ground-truth microstructural properties, but they have been scaled for training - need to de-scale below N = XX.shape[0] #How many images total in the input data file #Run inferences on N_samples random samples from XX. #Run in a batch, much more efficient than one at a time. ii = np.random.choice(N,N_samples,replace=False) ii.sort() y_pred = model(XX[ii]) #Get the original/true (but normalized/scaled) values from the training dataset... #Because they were normalized, they are not in real units yet. So let's also de-scale them using model.output_scaler. y_true = model.output_scaler.transform(yy[ii]) #Let's display actual values for just 5 random ones for i in np.random.choice(N_samples,5,replace=False): display_predictions(y_true[i], y_pred[i], model.prop_names) #Make parity plots for each property (ground truth vs predicted values) #Also label each plot with the mean abs. percent error (MAPE) of the predicted values for i,key in enumerate(model.prop_names): mape = calculate_mape(y_true[:,i], y_pred[:,i]) parity_plot(y_true[:,i], y_pred[:,i], figure_outdir, key, extra_title=f' ({mape:.2f}% MAPE)')

3D microstructure↗

CT Scans of Cores Metadata, Utqiagvik (Barrow), Alaska, 2015

Individual ice cores were collected from Barrow Environmental Observatory in Barrow, Alaska, throughout 2013 and 2014. Cores were drilled along different transects to sample polygonal features (i.e. the trough, center and rim of high, transitional and low center polygons). Most cores were drilled around 1 meter in depth and a few deep cores were drilled around 3 meters in depth. Three-dimensional images of the frozen cores were constructed using a medical X-ray computed tomography (CT) scanner. TIFF files can be uploaded to ImageJ (an open-source imaging software) to examine soil structure and soil densities within each core.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Characterization and Modeling of Cell Wall Imperfections in Aluminum Honeycomb Cores using X-ray CT Imaging

Honeycomb cell imperfections may significantly affect the failure of sandwich composites in core crushing and shear modes. Identification and quantification of the different types of imperfections and evaluation of their effects on the mechanical response of honeycomb cores in flatwise compression is presented. X-Ray computed tomography (CT) scans of honeycomb cores in co-cured composite sandwich panels were performed. Image analysis methods are applied to characterize and quantify core cell geometry and cell wall waviness. An approach is developed for extracting cell wall mid surface planes and waviness for constructing finite element models using shell elements. Analysis results from models with the as-manufactured imperfections are compared to results from models with idealized geometries to evaluate the effect of the as-manufactured imperfections on the initiation of cell wall buckling and subsequent core crushing.

aluminum honeycomb↗

Finite Element Modeling for Compression Strength Prediction of Honeycomb Cores with Geometric Imperfections Measured using X-ray CT Imaging

Aluminum honeycomb cores have been used extensively in composite sandwich panels due to having high bending rigidity while maintaining low density. During manufacturing of the aluminum honeycomb, the thin metal walls are susceptible to imperfections that deviate from an ideal honeycomb shape. Computational tools to quantify imperfections and investigate their effects on quasi-static compression and impact response can inform design criteria to construct safer and lighter launch vehicle structures. This paper presents the results of a study on finite element modeling of metallic honeycomb cores (HCC) with geometric imperfections measured using X-ray Computer Tomography (CT), to predict the compression response. Finite element (FE) models are constructed with measured imperfections with appropriate boundary conditions. It is shown that the average behavior of larger 10x11 cell models can be predicted by sampling single cell models from the larger domain. Amplification of imperfections for cells at the center of sampled specimens are mode switched from the larger out-of-plane imperfection to the mode shape of the adjacent cells resulting in strengthening of the center specimens.

aluminum honeycomb↗

In Situ Synchrotron Micro-CT of Microballoon-Filled RTV Silicone During Thermal Decomposition

This work investigates the thermal decomposition of microballoon-filled room-temperature-vulcanizing (RTV) silicone using time-resolved synchrotron micro-CT at the Advanced Light Source. In situ imaging of constrained and unconstrained samples captures the evolution of the internal microstructure during heating, including material expansion, microballoon and void growth, tearing, pyrolysis, shrinkage, and increasing porosity. The measurements provide new insight into the mechanisms governing RTV degradation and generate three-dimensional data for future quantitative analysis and material-response model development.

TPS↗

Through-thickness fracture behavior of neutron-irradiated nuclear graphite NBG-17 Using X-ray micro-CT

Achieving precise control over crack propagation in nuclear graphite and conducting quantitative analysis remain challenging. In this study, the through-thickness fracture behavior of pristine and neutron-irradiated (700 °C, ∼7 dpa) NBG-17 nuclear graphite was investigated using split-disc testing coupled with micro-computed tomography (micro-CT). A notably lower number of micropores was observed in the neutron-irradiated specimen. The fracture toughness of neutron-irradiated NBG-17 was measured to be 1.45 MPa√m, compared to 1.17 ± 0.05 MPa√m for the pristine specimen. In both materials, cracks were found to initiate at the filler–binder interface, and often correlated with microstructural features such as pores and thermal cracks. Crack bridging and deflections emerged as the primary toughening mechanisms in both unirradiated and irradiated NBG-17. However, compared with the pristine specimen, the cracks in the neutron-irradiated specimen were more likely to grow trans granularly, resulting in less deflected crack paths. The reduced micro-porosity and strengthened filler–binder boundaries were considered to be the cause of the observed differences in crack morphologies. In conclusion, this study provides a qualitative analysis of the fracture behavior of neutron-irradiated nuclear graphite in the absence of radiolytic oxidation.

36 - MATERIALS SCIENCE↗

Correlating electronic properties with M-site composition in solid solution Ti y Nb 2- y CT x MXenes

High electrical conductivity is desired in MXene films for applications such as electromagnetic interference shielding, antennas, and electrodes for electrochemical energy storage and conversion applications. Due to the acid etching-based synthesis method, it is challenging to deconvolute the relative importance that factors such as chemical composition and flake size contribute to resistivity. To understand the intrinsic and extrinsic contributions to the macroscopic electronic transport properties, a systematic study controlling compositional and structural parameters was conducted with eight solid solutions in the Ti y Nb 2-y CT x system. Here, in particular, we investigated the different roles played by metal (M)-site composition, flake size, and d-spacing on macroscopic transport. Hard x-ray photoemission spectroscopy and spectroscopic ellipsometry revealed changes to electronic structure induced by the M-site alloying. Consistent with the spectroscopic results, the low- and room-temperature conductivities and effective carrier mobility are correlated with the Ti content, while the impact of flake size and d-spacing is most prominent in low-temperature transport. The results provide guidance for designing and engineering MXenes with a wide range of conductivities.

36 MATERIALS SCIENCE↗

Enhancing synchrotron radiation micro-CT images using deep learning: an application of Noise2Inverse on bone imaging

In bone-imaging research, in situ synchrotron radiation micro-computed tomography (SRµCT) mechanical tests are used to investigate the mechanical properties of bone in relation to its microstructure. Low-dose computed tomography (CT) is used to preserve bone's mechanical properties from radiation damage, though it increases noise. To reduce this noise, the self-supervised deep learning method Noise2Inverse was used on low-dose SRµCT images where segmentation using traditional thresholding techniques was not possible. Simulated-dose datasets were created by sampling projection data at full, one-half, one-third, one-fourth and one-sixth frequencies of an in situ SRµCT mechanical test. After convolutional neural networks were trained, Noise2Inverse performance on all dose simulations was assessed visually and by analyzing bone microstructural features. Visually, high image quality was recovered for each simulated dose. Lacunae volume, lacunae aspect ratio and mineralization distributions shifted slightly in full, one-half and one-third dose network results, but were distorted in one-fourth and one-sixth dose network results. Following this, new models were trained using a larger dataset to determine differences between full dose and one-third dose simulations. Significant changes were found for all parameters of bone microstructure, indicating that a separate validation scan may be necessary to apply this technique for microstructure quantification. Noise present during data acquisition from the testing setup was determined to be the primary source of concern for Noise2Inverse viability. While these limitations exist, incorporating dose calculations and optimal imaging parameters enables self-supervised deep learning methods such as Noise2Inverse to be integrated into existing experiments to decrease radiation dose.

Obata, Yoshihiro (ORCID:0000000303659129)↗

A Co-Registered In-Situ and Ex-Situ Dataset of Electrical, Acoustic, and CT Characteristics from Wire Arc Additive Manufacturing Process

Recent progress in sensing techniques and data analytics tools have significantly accelerated the development of Wire Arc Additive Manufacturing (WAAM) systems. This data centric approach emphasizes leveraging available data throughout the production process to optimize performance. Integration of extensive data analysis provides the opportunity to improve precision, reduce waste, and enhance the quality of produced parts. This method relies on AI/ML models and optimization techniques, which are developed using the data collected from various sources, including in-situ sensors, ex-situ imaging, and manufacturing process parameters. The quality and diversity of this data, along with the alignment between different data streams (achieved through spatiotemporal registration) are critical for the successful development of AI/ML and optimization models. In this work, we present a spatiotemporally registered dataset generated during the WAAM process of deposition of a rectangular block. The dataset includes the comprehensive description of deposition process, process parameters, in-situ collected welding characteristics, acoustic data, and X-Ray Computed Tomography analysis data for the build. Dataset A Co-Registered In-Situ and Ex-Situ Dataset of Electrical, Acoustic, and CT Characteristics from Wire Arc Additive Manufacturing Process has arisen under UT-Battelle, LLC’s Prime Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy (DOE) to manage and operate the Oak Ridge National Laboratory. UT-Battelle, LLC will not assert any rights under United States law or under the Prime Contract it has in the dataset against any user of the dataset, including any copyrights or patent rights. UT-Battelle, LLC requests that attribution to the dataset is provided as academically appropriate.

42 ENGINEERING↗

CT and Scanning Data of the KGS Wellington 1-32 CarbonSAFE Core

Data described in the NETL Technical Report Series "Computed Tomography Scanning and Geophysical Measurements of the Wellington 1-32 Core", including processed and raw CT and measurements from NETL's multi-sensor core logger. Paronish, T.; Schmitt, R.; Mitchell, N; Brown, S; Crandall, D.; Moore, J.; Hasiuk, F.; Potter, N.; Holubnyak, Y.E. Computed Tomography Scanning and Geophysical Measurements of the Wellington 1-32 Core; DOE.NETL-2021.2882; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2022; p 108. DOI: https://doi.org/10.2172/1894355 https://edx.netl.doe.gov/dataset/computed-tomography-scanning-and-geophysical-measurements-of-the-wellington-1-32-core

CarbonSafe↗

PDF4LHC21: Update on the benchmarking of the CT, MSHT and NNPDF global PDF fits

There have been recent updates to the three global PDF fits (CT, MSHT and NNPDF), all adding large amounts of data from the LHC, and this has resulted in significant changes to the global PDFs. Given the impact that the new PDFs will have on physics comparisons at the LHC, it is crucial to perform a benchmarking among the PDFs, similar in spirit to that which was carried out for PDF4LHC15, widely used for LHC physics. In this article we detail a benchmarking comparison of three global PDF sets - CT18, MSHT20 and NNPDF3.1 - and their similarities and differences that have been observed. The end result of this study will be a new PDF4LHC21 ensemble of combined PDFs suitable for a wide range of LHC applications.

Cridge, Thomas↗

Dynamic Evaluation of the Upper Tyler Formation and Well Stimulation Fluid Interactions Using Micro-CT Imaging

Abundant concentrations of swelling clays in the oil-bearing upper Tyler Formation inhibit unconventional well stimulation techniques and associated long-term oil and gas production success. Laboratory evaluation of the geochemical interactions between the formation material and various stimulation fluids may help identify innovative approaches that provide a solution to successful well stimulation and subsequent oil production. The objective of this research was to understand the complexities of well stimulation fluid and clay mineral interactions within the Tyler Formation and identify potential fracturing fluid formulations that mitigate swelling properties of the clays in the reservoir to enhance stimulation success and promote long-term oil and gas production. Collaboration with the National Energy Technology Laboratory (NETL), utilizing their Tescan DynaTOM micro-CT analysis instrumentation, provided an innovative approach to understand real-time, dynamic interactions of the formation material and various potential stimulation fluids. Results are anticipated to identify key mechanisms occurring at the micro-scale level and provide insight into modified stimulation techniques uniquely suited for successful production applications.

enhanced oil recovery↗

A new CT collimator for producing two simultaneous overlapping slices from one scan

A new CT collimator is developed which is capable of producing two simultaneous successive overlapping images from a single scan. The collimator represents a modification of the standard EMI 5005 collimator achieved by alternately masking one end or portions of both ends of the X-ray detectors at a 13-mm beamwidth so that a set of 540 filtered projections is obtained for each scan which can be separated into two sets of interleaved projections corresponding to views 3 mm apart. Tests have demonstrated that the quality of the images produced from these two projections almost equals the quality of those produced by the standard collimator from two separate scans. The new collimator may thus be used to achieve a speed improvement in the generation of overlapping sections as well as a reduction in X-ray dosage.

Kwoh, Y. S.↗

Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction

This paper presents a new reconstruction algorithm for both single- and dual-energy computed tomography (CT) imaging. By incorporating the polychromatic characteristics of the X-ray beam into the reconstruction process, the algorithm is capable of eliminating beam hardening artifacts. The single energy version of the algorithm assumes that each voxel in the scan field can be expressed as a mixture of two known substances, for example, a mixture of trabecular bone and marrow, or a mixture of fat and flesh. These assumptions are easily satisfied in a quantitative computed tomography (QCT) setting. We have compared our algorithm to three commonly used single-energy correction techniques. Experimental results show that our algorithm is much more robust and accurate. We have also shown that QCT measurements obtained using our algorithm are five times more accurate than that from current QCT systems (using calibration). The dual-energy mode does not require any prior knowledge of the object in the scan field, and can be used to estimate the attenuation coefficient function of unknown materials. We have tested the dual-energy setup to obtain an accurate estimate for the attenuation coefficient function of K2 HPO4 solution.

NASA Center ARC↗

Nondestructive Analysis of Apollo Samples by Micro-CT and Micro-XRF Analysis: A PET Style Examination

An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of a PET is to characterize and classify the returned samples, making this information available to the general research community who can then conduct more in-depth studies on the samples. A PET strives to minimize the impact their work has on the sample suite, which often limits the PET work to largely visual measurements and observations like optical microscopy. More modern techniques can also be utilized by future PET to nondestructively characterize astromaterials in a more rigorous way. Here we present our recent analyses of Apollo samples 14321 and 14305 by micro-CT and micro-XRF (respectively), assess the potential for discovery of "new" Apollo samples for scientific study, and evaluate the usefulness of these techniques in future PET efforts.

Zeigler, Ryan A.↗

Comprehensive Non-Destructive Conservation Documentation of Lunar Samples Using High-Resolution Image-Based 3D Reconstructions and X-Ray CT Data

Established contemporary conservation methods within the fields of Natural and Cultural Heritage encourage an interdisciplinary approach to preservation of heritage material (both tangible and intangible) that holds "Outstanding Universal Value" for our global community. NASA's lunar samples were acquired from the moon for the primary purpose of intensive scientific investigation. These samples, however, also invoke cultural significance, as evidenced by the millions of people per year that visit lunar displays in museums and heritage centers around the world. Being both scientifically and culturally significant, the lunar samples require a unique conservation approach. Government mandate dictates that NASA's Astromaterials Acquisition and Curation Office develop and maintain protocols for "documentation, preservation, preparation and distribution of samples for research, education and public outreach" for both current and future collections of astromaterials. Documentation, considered the first stage within the conservation methodology, has evolved many new techniques since curation protocols for the lunar samples were first implemented, and the development of new documentation strategies for current and future astromaterials is beneficial to keeping curation protocols up to date. We have developed and tested a comprehensive non-destructive documentation technique using high-resolution image-based 3D reconstruction and X-ray CT (XCT) data in order to create interactive 3D models of lunar samples that would ultimately be served to both researchers and the public. These data enhance preliminary scientific investigations including targeted sample requests, and also provide a new visual platform for the public to experience and interact with the lunar samples. We intend to serve these data as they are acquired on NASA's Astromaterials Acquisistion and Curation website at http://curator.jsc.nasa.gov/. Providing 3D interior and exterior documentation of astromaterial samples addresses the increasing demands for accessability to data and contemporary techniques for documentation, which can be realized for both current collections as well as future sample return missions.

Blumenfeld, E. H.↗

Large-Scale CT Inspection of Feed-Through EMI Filters for Space Application

A type of Feed-Through Electromagnetic Interference (EMI) Filter incorporating two discoidal (ring-shaped) capacitors was selected for use in the Europa Clipper spacecraft propulsion systems. Parts reliability specialists were aware of historical problems with the attach materials used to provide mechanical support and electrical contact within these devices, so therefore a screening was desired to ensure the longevity and ruggedness of units intended for the space environment. CT X-ray, a technology which has become more widely available thanks to the compelling depth of information it offers, was selected as the inspection method of choice.

Bescup, John C↗