Influence of correlated visual cues on auditory signal detection
Influence of correlated visual cues on auditory signal detection
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Influence of correlated visual cues on auditory signal detection
An investigation of the behavior of the human decisionmaker is described for a task related to the problem of a pilot using a traffic situation display to avoid collisions. This sequential signal detection task is characterized by highly correlated signals with time varying strength. Experimental results are presented and the behavior of the observers is analyzed using the theory of Markov processes and classical signal detection theory. Mathematical models are developed which describe the main result of the experiment: that correlation in sequential signals induced perseveration in the observer response and a strong tendency to repeat their previous decision, even when they were wrong.
Combustion byproducts are numerous. A few examples of the gaseous byproducts include carbon dioxide, carbon monoxide, hydrogen chloride, hydrogen cyanide and ammonia. For detecting these chemical species, classic absorption spectroscopy has been used for many decades, but the sensitivity of steady-state methods is often unsuitable for the detection of trace compounds at the low levels (parts per million to parts per billion) appropriate for scientific purposes. This is particularly so for monitoring equipment, which must be compact and cost-effective, and which is often subjected to shock, vibration, and other environmental effects that can severely degrade the performance of high-sensitivity spectrometers in an aircraft. Steady-state techniques also suffer from a lack of specificity; the deconvolution of the spectra of complex mixtures is a laborious and error prone process. These problems are exacerbated in remote fiber-optic monitoring where, for practical reasons, the fundamental absorbance region of the spectrum (often between 3 and 8 microns) is inaccessible, and the low-strength, closely spaced, near-infrared overtone absorbance bands must be used. We circumvented these challenges by employing correlation spectroscopy, a variation of modulation spectroscopy.
A modified correlation mass method for calculating the value of a possible neutrino mass from neutrino bursts of astrophysical origin is proposed which can more sensitively detect small neutrino masses than previous methods. Application of the method to the neutrinos detected from SN 1987 A yields a value of 3.6 + or - 0.3 eV for the neutrino mass energy with a confidence level of 97 percent. Assuming a neutrino mass of 3.6 eV, and transforming all of the detected neutrino events back to the point of emission, it is shown that bursts are composed of a short initial pulse (which lasts for about 0.1 sec and contains 30-40 percent of the total neutrinos) and an extended emission lasting for about 10 sec.
New detections of supermassive black hole (BH) candidates are used to update the observed correlation between BH mass M and the luminosity L(sub bulge) of the bulge component of the host galaxy. Our main purpose is to test whether the correlation is real or just the upper envelope of a distribution that extends to smaller Solar Mass. We also illustrate the following conclusions: 1 -- BH mass correlates much better with bulge luminosity than with the total luminosity of the galaxy. 2 -- BH mass correlates with the luminosity of the high-density central component in disk galaxies independent of whether that component is a classical bulge (essentially a mini-elliptical) or a pseudobulge (believed to form via inward transport of disk material). This conclusion is based on only three pseudobulges, so it needs to be checked. 3 -- The BH mass correlates with the velocity dispersion of the bulge component outside the region influenced by the BH. That is, it correlates with the depth of the potential well in which it lives. Our conclusions are consistent with the hypothesis that (pseudo)bulge formation and BH feeding are closely connected. To first order, present data do not show any dependence of M\bullet on the details of whether BH feeding happens rapidly during a collapse or slowly via secular evolution of the disk.
An algorithm was developed for the assessment of strain-gage balance calibration data that makes it possible to systematically investigate potential sources of unexpected high correlations between calibration load residuals and applied calibration loads. The algorithm investigates correlations on a load series by load series basis. The linear correlation coefficient is used to quantify the correlations. It is computed for all possible pairs of calibration load residuals and applied calibration loads that can be constructed for the given balance calibration data set. An unexpected high correlation between a load residual and a load is detected if three conditions are met: (i) the absolute value of the correlation coefficient of a residual/load pair exceeds 0.95; (ii) the maximum of the absolute values of the residuals of a load series exceeds 0.25 % of the load capacity; (iii) the load component of the load series is intentionally applied. Data from a baseline calibration of a six-component force balance is used to illustrate the application of the detection algorithm to a real-world data set. This analysis also showed that the detection algorithm can identify load alignment errors as long as repeat load series are contained in the balance calibration data set that do not suffer from load alignment problems.
The general correlation principles for spectra and spectra derivatives are studied by using the Fourier transform of the spectral distribution of energy from a source illuminating a double beam interferometer with transverse splitting by dividing luminance. In this correlation technique, the use of such an interferometer has the advantage of greater luminosity as compared with a slit spectrometer. However, the correlation example indicates that it is necessary to adapt the correlator to the particular case considered, in order to obtain the best gain in the signal to noise ratio. In the case of sulfur dioxide detection, a very simple mounting which could be used in some interesting industrial applications was developed. This mounting can be used each time that the substance to be analyzed has a quasi-periodic absorption spectrum: in particular this is often the case with absorption spectra of gases, and a mounting identical to the one described for sulfur dioxide proved to be effective in the detection of nitrogen oxides.
We present a miniaturized and simplified version of a gas correlation radiometer (GCR) capable of simultaneously mapping multiple trace gases and identifying active regions on the Mars surface. Gas correlation radiometry (GCR) has been shown to be a sensitive and versatile method for detecting trace gases in Earth's atmosphere. Reduction of the size and mass of the GCR was achieved by implementing compact, light-weight 1 mm inner diameter hollow-core optical fibers (hollow waveguides) as the gas correlation cells. In a comparison with an Earth orbiting CO2 GCR instrument, exchanging the 10 m multipass cells with hollow waveguide gas correlation cells of equivalent path length reduces the mass from approximately 150 kg to approximately 0.5 kg, and reduces the volume from 1.9 m x 1.3 m x 0.86 m to a small bundle of fiber coils approximately 1 meter in diameter by 0.05 m in height (mass and volume reductions of greater than 99%). A unique feature of this instrument is its stackable module design, with a single module for each trace gas. Each of the modules is self-contained, and fundamentally identical; differing by the bandpass filter wavelength range and gas mixtures inside the hollow-waveguide absorption cells. The current configuration contains four stacked modules for simultaneous measurements of methane (CH4), formaldehyde (H2CO), water vapor (H2O), and deuterated water vapor (HDO) but could easily be expanded to include measurements of additional species of interest including nitrous oxide (N2O), hydrogen sulfide (H2S), methanol (CH3OH), and sulfur dioxide (SO2), as well as carbon dioxide (CO2) for a simultaneous measure of mass balance. Preliminary results indicate that a 1 ppb detection limit is possible for both formaldehyde and methane with one second of averaging. Using non-optimized components, we have demonstrated an instrument sensitivity equivalent to approximately 30 ppb for formaldehyde, and approximately 500 ppb for methane. We expect custom bandpass filters and 6 m long waveguides to significantly improve these promising results. Ongoing testing is being conducted on water vapor and deuterated water vapor.
This poster summarizes work completed for the NA-22 STILGAR project using seismic cross-correlation to detect human-generated subsurface activity. It will be presented at the 2024 American Geophysical Union Fall Meeting.
A proposed optoelectronic instrument would identify targets rapidly, without need to radiate an interrogating signal, apply identifying marks to the targets, or equip the targets with transponders. The instrument was conceived as an identification, friend or foe (IFF) system in a battlefield setting, where it would be part of a targeting system for weapons, by providing rapid identification for aimed weapons to help in deciding whether and when to trigger them. The instrument could also be adapted to law-enforcement and industrial applications in which it is necessary to rapidly identify objects in view. The instrument would comprise mainly an optical correlator and a neural processor (see figure). The inherent parallel-processing speed and capability of the optical correlator would be exploited to obtain rapid identification of a set of probable targets within a scene of interest and to define regions within the scene for the neural processor to analyze. The neural processor would then concentrate on each region selected by the optical correlator in an effort to identify the target. Depending on whether or not a target was recognized by comparison of its image data with data in an internal database on which the neural processor was trained, the processor would generate an identifying signal (typically, friend or foe ). The time taken for this identification process would be less than the time needed by a human or robotic gunner to acquire a view of, and aim at, a target. An optical correlator that has been under development for several years and that has been demonstrated to be capable of tracking a cruise missile might be considered a prototype of the optical correlator in the proposed IFF instrument. This optical correlator features a 512-by-512-pixel input image frame and operates at an input frame rate of 60 Hz. It includes a spatial light modulator (SLM) for video-to-optical image conversion, a pair of precise lenses to effect Fourier transforms, a filter SLM for digital-to-optical correlation-filter data conversion, and a charge-coupled device (CCD) for detection of correlation peaks. In operation, the input scene grabbed by a video sensor is streamed into the input SLM. Precomputed correlation-filter data files representative of known targets are then downloaded and sequenced into the filter SLM at a rate of 1,000 Hz. When there occurs a match between the input target data and one of the known-target data files, the CCD detects a correlation peak at the location of the target. Distortion- invariant correlation filters from a bank of such filters are then sequenced through the optical correlator for each input frame. The net result is the rapid preliminary recognition of one or a few targets.
Swift has now detected a large enough sample of gamma-ray bursts (GRBs) to allow correlation studies of burst parameters. Such studies of earlier data sets have yielded important results leading to further understanding of burst parameters and classifications. This work focuses on seventeen Swift bursts that have also been detected either by Konus-Wind or HETE-II, providing high energy spectra and fits to E(sub peak). Eight of these bursts have spectroscopic redshifts and for others we can estimate redshifts using the variability/luminosity relationship. We can also compare E(sub peak) with E(sub iso), and for those bursts for which a jet break was observed in the afterglow we can derive E(sub g) and test the relationship between E(peak) and E(sub gamma). For all bursts we can derive durations and hardness ratios from the prompt emission.
Gas correlation radiometry (GCR) has been shown to be a sensitive and versatile method for detecting trace gases in Earth's atmosphere. Here, we present a miniaturized and simplified version of this instrument capable of mapping multiple trace gases and identifying active regions on the Mars surface. Reduction of the size and mass of the GCR instrument has been achieved by implementing a lightweight, 1 mm inner diameter hollow-core optical fiber (hollow waveguide) for the gas correlation cell. Based on a comparison with an Earth orbiting CO2 gas correlation instrument, replacement of the 10 meter mUltipass cell with hollow waveguide of equivalent pathlength reduces the cell mass from approx 150 kg to approx 0.5 kg, and reduces the volume from 1.9 m x 1.3 m x 0.86 m to a small bundle of fiber coils approximately I meter in diameter by 0.05 m in height (mass and volume reductions of >99%). This modular instrument technique can be expanded to include measurements of additional species of interest including nitrous oxide (N2O), hydrogen sulfide (H2S), methanol (CH3OH), and sulfur dioxide (SO2), as well as carbon dioxide (CO2) for a simultaneous measure of mass balance.
A new type of DIAL system for the detection of methane in the atmosphere is being developed. The main feature of this lidar is the use of a gas correlation technique to obtain the reference signal by means of a single laser pulse, instead of two shots at different wavelengths. This fact is useful to make measurements on fast moving platforms. To meet the infrared absorption band of methane an optical parametric oscillator (OPO) was used with a LiNbO3 crystal as active element, and a tuning range between 1.5 divided by 4 microns. As known, the major problem to overcome in parametric oscillators are the pump beam quality and the difficulty in reducing the linewidth. The first requirement is met by using, as a pump, a Nd-YAG laser based on a new type of resonator cavity, named SFUR (Self Filtering Unstable Resonator). The laser emits, with high efficiency, near diffraction limited pulsed beams of about 250 mJ of energy, 20 ns of duration at 10 pps of frequency repetition rate. On the other hand, the gas correlation technique allows the operation with a bandwidth as large as 1/cm, which is obtainable using only a diffraction grating as a dispersive element in the OPO cavity.
The Murray formation is predominantly composed of lacustrine mudstone that forms the basal layer of Aeolis Mons (informally Mt. Sharp) in Gale Crater, Mars. The Murray formation has distinct iron and sulfur mineralogical variation within its stratigraphy detectable by the Chemistry Mineralogy (Che-Min) instrument consisting of magnetite/hematite in the lower Murray and higher hematite, CaSO4, and smectite content in the upper Murray. The objectives of this work were to evaluate the Sample Analysis at Mars Evolved Gas Analyzer (SAM-EGA) data to 1) Determine what SAM-EGA-detectable phases correlate or do not correlate with the Murray mineralogical composition detected by CheMin and 2) Utilize CheMin/SAM results to propose possible formation scenarios for the observed Murray mudstone mineralogy.
Detection of monaural signals as function of interaural noise correlation and signal frequency
It is now well known that a complete understanding of the energetics of the prompt phase of gamma-ray bursts (GRBs) requires full knowledge of the spectrum, extending at least as high as the peak energy (Epeak) of the vF(v) spectrum. Since most gamma-ray bursts (GRBs) have Epeak above the energy range (15-150 keV) of the Burst Alert Telescope (BAT) on Swift, a full understanding of the prompt emission from Swift GRBs requires spectral fits over as broad an energy range as possible. This can be completed for bursts which are simultaneously detected by Swift BAT and the Suzaku Wide-band All-Sky Monitor (WAM), which covers the energy range from 50-5000 keV. Between the launch of Suzaku in July 2005 and the end of 2008, there were 44 gamma-ray bursts (GRBs) which triggered both Swift and WAM and an additional 41 bursts which triggered Swift and were detected by WAM, but did not trigger. A joint BAT-WAM team has cross-calibrated the two instruments using GRBs, and we are now able to perform joint fits on these bursts to determine spectral parameters including Epeak. The results of broad spectral fits allows us to understand the distribution of Epeak for Swift bursts and to calibrate Epeak estimators when Epeak is within the BAT energy range. For those bursts with spectroscopic redshifts, we can calculate the isotropic energy and study various correlations between Epeak and other global burst parameters. Here we present the results of joint Swift/BAT-Suzaku/WAM spectral fits for 77 of the bursts jointly detected by the two instruments. We show that the distribution of spectral fit parameters is consistent with distributions from earlier missions and confirm that Swift bursts are consistent with earlier reported relationships between Epeak and isotropic energy. We show through time-resolved spectroscopy that individual burst pulses are also consistent with this relationship.
Pin-point landing is required to enable missions to land close, typically within 10 meters, to scientifically important targets in generally hazardous terrain. In Pin Point Landing both high accuracy and high speed estimation of position and orientation is needed to provide input to the control system to safely choose and navigate to a safe landing site. A proposed algorithm called VISion aided Inertial NAVigation (VISINAV) has shown that the accuracy requirements can be met. [2][3] VISINAV was shown in software only, and was expected to use FPGA enhancements in the future to improve the computational speed needed for pin point landing during Entry Descent and Landing (EDL). Homography, feature detection and spatial correlation are computationally intensive parts of VISINAV. Homography aligns the map image with the descent image so that small correlation windows can be used, and feature detection provides regions that spatial correlation can track from frame to frame in order to estimate vehicle motion. On MER the image Homography, Feature Detection and Correlation would take approximately 650ms tracking 75 features between frames. We implemented Homography, Feature detection and Correlation on a Virtex 4 LX160 FPGA to run in under 25ms while tracking 500 features to improve algorithm reliability and throughput.
Human auditory signal detection related to averaged evoked potential in scalp by electrophysiological measurements