Simultaneous film and convection cooling of a plate inserted in the exhaust stream of a gas turbine combustor

Data were obtained on a parallel-flow film- and convection-cooled test section placed in the exhaust stream of a rectangular-sector combustor. The combustor was operated at atmospheric pressure and at exhaust temperatures of 589 and 1033 K (600 and 1400 F). The cooling air was at ambient pressure and temperature. Test results indicate that it is better to use combined film and convection cooling rather than either film or convection cooling alone for a fixed total coolant flow. An optimum ratio of film to convection cooling flow rates was determined for the particular geometry tested. The experimental results compared well with calculated results.

Marek, C. J.↗

Effect of pressure on tangential-injection film cooling in a combustor exhaust stream

A tangential-injection film cooled test section was placed in the exhaust stream of a high pressure combustor. Film cooling data were taken at pressure of 1, 10, and 20 atmospheres. The film cooling effectiveness was found to be independent of pressure. The data were correlated adequately by a turbulent-mixing film cooling correlation with a turbulent-mixing coefficient of 0.05 + or - 0.02.

Marek, C. J.↗

Solar residential heating and cooling system development test program

A solar heating and cooling system is described, which was installed in a simulated home at Marshall Space Flight Center. Performance data are provided for the checkout and initial operational phase for key subsystems and for the total system. Valuable information was obtained with regard to operation of a solar cooling system during the first summer of operation. Areas where improvements and modifications are required to optimize such a system are discussed.

Humphries, W. R.↗

Advanced Film Cooling Rig: Development and Test Results

The Advanced Film Cooling Rig (AFCR) test was a program to develop a thermal imaging camera system to measure the effectiveness of multihole film cooling. This system was used to evaluate low-thermal conductivity ceramic test panels incorporating a wide range of multihole cooling geometries. Tests were conducted with a mainstream flow of 600 F at Mach numbers of 0.37 and 1.57. Coolant flow was controlled to give a blowing parameter variation of up to 2.9. Data reduction techniques are given for camera calibration, rig temperature reflection correction, and deriving surface temperatures from video images. Results are presented in terms of overall and film cooling effectiveness distributions. A one-dimensional analysis of a unit film cooling hole was performed to generate film temperature.

Reilly, R. S.↗

Mu2e Target Thermal Test Project

The Mu2e experiment requires a production target capable of operating under extreme thermal conditions caused by an 8 GeV proton beam. This project’s objective supports the development of the Mu2e Production Target by testing the Stickman model’s thermal behavior. To test this, Angel Flores Luviano has assisted Jonathan Williams in progressing this project by contributing to the development of a Radiative Cooling Test Fixture (RCTF) that will be used to evaluate the thermal behavior of the new production target model. Engineering calculations were performed to analyze thermal performance and pressure drop within the cold well and water cooling circuit, and determine optimal sizing for key components of the water system. An engineering note was made to document the calculations. CAD models of the water circuit piping, thermocouple mount, and radiator chimney were developed, and prototype test rig components were fabricated using 3D printing. Future work will focus on conti nued RCTF development which includes control system integration, heater hardware design, and interfaces that can be scaled up to increase thermal capacity.

Luviano, Angel Flores [Unlisted]↗

Mu2e Production Target Thermal Test Project

The Mu2e experiment requires a production target that is capable of operating under extreme thermal conditions caused by an 8 GeV proton beam. This project’s objective supports the development of the Mu2e Pro- duction Target by testing the Stickman model’s thermal behavior. Angel Flores Luviano has assisted Jonathan Williams in progressing this project by contributing to the development of a Radiative Cooling Test Fixture (RCTF) that will be used to evaluate the thermal behavior of the new production target model. Engineering calculations were performed to an- alyze thermal performance and pressure drop within the cold well and wa- ter cooling circuit. These calculations also determined the optimal sizing for key components of the water system. An engineering note was made to document these calculations. CAD models of the water circuit piping, thermocouple mounting bars, and radiator chimney were developed, and prototype test rig components were fabricated using 3D printing. Future work will focus on continued RCTF development which includes control system integration, heater hardware design, and interfaces that can be scaled up to increase thermal capacity.

Flores Luviano, Angel Augusto [Unlisted, US]↗

Design, fabrication, testing and delivery of a solar collector

A two phase program encompassing the redesign and fabrication of a solar collector which is low in cost and aesthetically appealing is described. Phase one work reviewed the current collector design and developed a low-cost design based on specific design/performance/cost requirements. Throughout this phase selected collector component materials were evaluated by testing and by considering cost, installation, maintainability and durability. The resultant collector design was composed of an absorber plate, insulation, frame, cover, desiccant and sealant. In Phase two, three collector prototypes were fabricated and evaluated for both nonthermal and thermal characteristics. Tests included static load tests of covers, burst pressure tests of absorber plates, and tests for optical characteristics of selective absorber plate coatings. The three prototype collectors were shipped to Marshall Space Flight Center for use in their solar heating and cooling test facility.

Sims, W. H.↗

Three computer codes to read, plot and tabulate operational test-site recorded solar data

Computer programs used to process data that will be used in the evaluation of collector efficiency and solar system performance are described. The program, TAPFIL, reads data from an IBM 360 tape containing information (insolation, flowrates, temperatures, etc.) from 48 operational solar heating and cooling test sites. Two other programs, CHPLOT and WRTCNL, plot and tabulate the data from the direct access, unformatted TAPFIL file. The methodology of the programs, their inputs, and their outputs are described.

Stewart, S. D.↗

Testing of a Miniature Loop Heat Pipe Using a Thermal Electrical Cooler for Temperature Control

This paper describes the design and testing of a miniature LHP having a 7 mm O.D. evaporator with an integral CC. The vapor line and liquid line are made of 1.6mm stainless steel tubing. The evaporator and the CC are connected on the outer surface by a copper strap and a thermoelectric (TEC) is installed on the strap. The TEC is used to control the CC temperature by applying an electrical current for heating or cooling. Tests performed in ambient included start-up, power cycle, sink temperature cycle, and CC temperature control using TEC. The LHP demonstrated very robust operation in all tests where the heat load varied between 0.5W and 1OOW, and the sink temperature varied between 243K and 293K. The heat leak from the evaporator to the CC was extremely small. The TEC was able to control the CC temperature within +/-0.3K under all test conditions, and the required control heater power was less than 1W.

Ku, Jentung↗

Monitoring Delamination of Thermal Barrier Coatings During Interrupted High-Heat-Flux Laser Testing using Luminescence Imaging

This presentation showed progress made in extending luminescence-base delamination monitoring to TBCs exposed to high heat fluxes, which is an environment that much better simulates actual turbine engine conditions. This was done by performing upconversion luminescence imaging during interruptions in laser testing, where a high-power CO2 laser was employed to create the desired heat flux. Upconverison luminescence refers to luminescence where the emission is at a higher energy (shorter wavelength) than the excitation. Since there will be negligible background emission at higher energies than the excitation, this methods produces superb contrast. Delamination contrast is produced because both the excitation and emission wavelengths are reflected at delamination cracks so that substantially higher luminescence intensity is observed in regions containing delamination cracks. Erbium was selected as the dopant for luminescence specifically because it exhibits upconversion luminescence. The high power CO2 10.6 micron wavelength laser facility at NASA GRC was used to produce the heat flux in combination with forced air backside cooling. Testing was performed at a lower (95 W/sq cm) and higher (125 W/sq cm) heat flux as well as furnace cycling at 1163C for comparison. The lower heat flux showed the same general behavior as furnace cycling, a gradual, "spotty" increase in luminescence associated with debond progression; however, a significant difference was a pronounced incubation period followed by acceleration delamination progression. These results indicate that extrapolating behavior from furnace cycling measurements will grossly overestimate remaining life under high heat flux conditions. The higher heat flux results were not only accelerated, but much different in character. Extreme bond coat rumpling occurred, and delamination propagation extended over much larger areas before precipitating macroscopic TBC failure. This indicates that under the higher heat flux (and surface & interface temperatures), the TBC was more tolerant of damage. The main conclusions were that high heat flux conditions can not only accelerate TBC debond progression but can also grossly alter the pathway of delamination.

Eldridge, Jeffrey I.↗

Hypersonic research engine project. Phase 2: Structures and cooling development

The flightweight components were adapted to form the basic engine assembly. The water cooled test adapters for use in wind tunnel tests were fabricated. Commercially available valves were selected for the coolant control system. The simplification of the temperature control concept and of the absence of weight and volume constraints made it possible to use these valves. Various calibration tests are also discussed.

Jilly, L. F.↗

Cold-air annular-cascade investigation of aerodynamic performance of core-engine-cooled turbine vanes. 1: Solid-vane performance and facility description

The aerodynamic performance of a solid (uncooled) version of a core engine cooled stator vane was experimentally determined in a full-annular cascade, where three-dimensional effects could be obtained. The solid vane, which serves as a basis for comparison with subsequent cooled tests, was tested over a range of aftermixed critical velocity ratios of 0.57 to 0.90. Overall vane aftermixed efficiencies were obtained over this critical velocity ratio range and compared with results from a two-dimensional cascade. The variation in vane efficiency and aftermixed flow conditions with circumferential and radial position were obtained and compared with design values. Vane surface static-pressure distributions were also measured and compared with theoretical results.

Goldman, L. J.↗

Development of a solar powered residential air conditioner (General optimization)

A commercially available 3-ton residential Lithium Bromide (LiBr) absorption air conditioner was modified for use with lower temperature solar heated water. The modification included removal of components such as the generator, concentration control chamber, liquid trap, and separator; and the addition of a Chrysler designed generator, an off-the-shelf LiBr-solution pump. The design goal of the modified unit was to operate with water as the heat-transfer fluid at a target temperature of 85 C (185 F), 29.4 C (85 F) cooling water inlet, producing 10.5 kW (3 tons) of cooling. Tests were performed on the system before and after modification to provide comparative data. At elevated temperatures (96 C, 205 F), the test results show that Lithium Bromide was carried into the condenser due to the extremely violent boiling and degraded the evaporator performance.

Lowen, D. J.↗

A re-entrant groove hydrogen heat pipe

This paper extends the development of reentrant groove technology to hydrogen heat pipes. Parametric analyses are presented which optimize the theoretical design while considering the limitations of state-of-the-art extrusion technology. Acceptable production-type runs of extruded lengths (over 300 m) could only be achieved at the expense of a wider nominal groove opening than specified (0.33 mm vs. 0.20 mm). However, dimensional variations of other critical dimensions were within 0.05 mm, which exceeded expectations. The 6063-T6 aluminum extrusion is 14.6 mm OD with a wall thickness of 1.66 mm and contains 20 axial grooves which surround a central 9.3-mm-diam vapor core. Each axial groove is 0.775-mm-diam with a 0.33 mm opening. An excess vapor reservoir is provided at the evaporator to minimize the pressure containment hazard during ambient storage. Details of the instrumentation and helium-cooled test installation are also presented.

Alario, J.↗

Thermal behavior of laboratory models of honeycomb-covered solar ponds

Laboratory experiments were conducted to provide insight into the technical feasibility of honeycomb-covered solar ponds. Cooling tests using honeycomb panels of various materials and geometries showed that a 5.7-cm-thick one-tier panel insulated as effectively as a 10-cm fiberglass slab. Heating tests demonstrated that a model pond covered with a polycarbonate panel boiled upon 16 hours of continuous exposure to a 150-W spotlight. Analysis of the experimental data indicates positively that honeycomb-covered solar ponds can be expected to perform satisfactorily, and that larger-scale outdoor tests should be conducted to provide a more realistic assessment and a more refined performance estimate.

Lin, E. I. H.↗