Development of a space qualified Surface Tension Confined Liquid Cryogen Cooler (STCLCC)

The Surface Tension Confined Liquid Cryogen Cooler (STCLCC), a new type of cryogenic cooler which is being developed by the NASA-GSFC for spaceflight payloads, is described. The STCLCC will be capable of maintaining instrumentation within the temperature range of 10-120 K and will allow liquid cryogens to be flown in space without the risk of liquid being entrained in the vent gas. A low-density open-cell material in the STCLCC acts as a 'sponge', with the surface tension trapping the liquid cryogen within its pores and keeping the liquid away from the cooler's vent during launch, zero-g operations, and landing. It is emphasized that the STCLCC concept is amenable to a wide variety of applications, whenever a passive low-cost cooler is required or when the on-orbit service of a cooler would increase a mission's lifetime.

Castles, Stephen H.↗

Mechanical cooler-to-Dewar interfacing in a long-lifetime, hybrid stored cryogen system

The means for making efficient use of mechanical coolers to limit the parasitic heating into the Dewar are addressed. Thermal efficiency is achieved by minimizing the parasitic heating and thermal impedance of the cooler-to-Dewar interface within the mechanical constraints. The important issues related to compatibility with the instrument system are also briefly discussed. Parasitic heating from the nonoperating (reserved or failed) cooler pair can be reduced with an active thermal switch that isolates the cooler cold tips from the cold finger. An analysis was performed to determine the optimal switch-operating characteristics for this application. Requirements associated with the use of the coolers, analyses performed, and the interface design concept are discussed.

Hopkins, R. A.↗

Spaceborne Passive Radiative Cooler

Radiative coolers are passive refrigeration devices for satellites and space probes that provide refrigeration for an infrared or other type of detector that operates at cryogenic temperatures. Typically a cooler can supply 20 mW of cooling at about 85 K, and over 500 mW of cooling at about 165 K. The exact cooler temperatures and heat loads are dependent upon the clear field of view of the cooler to space. Some features of the Arthur D. Little passive radiative cooler are given.

Mathias, S.↗

Lightweight Magnetic Cooler With a Reversible Circulator

A design of a highly efficient and lightweight space magnetic cooler has been developed that can continuously provide remote/distributed cooling at temperatures in the range of 2 K with a heat sink at about 15 K. The innovative design uses a cryogenic circulator that enables the cooler to operate at a high cycle frequency to achieve a large cooling capacity. The ability to provide remote/distributed cooling not only allows flexible integration with a payload and spacecraft, but also reduces the mass of the magnetic shields needed. The active magnetic regenerative refrigerator (AMRR) system is shown in the figure. This design mainly consists of two identical magnetic regenerators surrounded by their superconducting magnets and a reversible circulator. Each regenerator also has a heat exchanger at its warm end to reject the magnetization heat to the heat sink, and the two regenerators share a cold-end heat exchanger to absorb heat from a cooling target. The circulator controls the flow direction, which cycles in concert with the magnetic fields, to facilitate heat transfer. Helium enters the hot end of the demagnetized column, is cooled by the refrigerant, and passes into the cold-end heat exchanger to absorb heat. The helium then enters the cold end of the magnetized column, absorbing heat from the refrigerant, and enters the hot-end heat exchanger to reject the magnetization heat. The efficient heat transfer in the AMRR allows the system to operate at a relatively short cycle period to achieve a large cooling power. The key mechanical components in the magnetic cooler are the reversible circulator and the magnetic regenerators. The circulator uses non-contacting, self-acting gas bearings and clearance seals to achieve long life and vibration- free operation. There are no valves or mechanical wear in this circulator, so the reliability is predicted to be very high. The magnetic regenerator employs a structured bed configuration. The core consists of a stack of thin GGG disks alternating with thin polymer insulating films. The structured bed reduces flow resistance in the regenerator and therefore the pumping work by the cryogenic circulator. This magnetic cooler will enable cryogenic detectors for sensing infrared, x-ray, gamma-ray, and submillimeter radiation in future science satellites, as well as the detector systems in the Constellation-X (Con-X) and the Single Aperture Far-Infrared observatory (SAFIR). Scientific ap p - lica tions for this innovation include cooling for x-ray micro calorimeter spectrometers used for microanalysis, cryogenic particle detectors, and superconducting tunnel junction de tectors for biomolecule mass spectrometry. The cooler can be scaled to provide very large cooling capacities at very low temperatures, ideal for liquid helium and liquid hydrogen productions.

Chen, Weibo↗

Low-Energy Run of Fermilab Electron Cooler's Beam Generation System

In the context of the evaluation of possibly using the Fermilab Electron Cooler for the proposed low-energy RHIC run at BNL, operating the cooler at 1.6 MeV electron beam energy was tested in a short beam line configuration. The main conclusion of this feasibility study is that the cooler's beam generation system is suitable for BNL needs. The beam recirculation was stable for all tested parameters. In particular, a beam current of 0.38 A was achieved with the cathode magnetic field up to the maximum value presently available of 250 G. The energy ripple was measured to be 40 eV. A striking difference with running the 4.3 MeV beam (nominal for operation at FNAL) is that no unprovoked beam recirculation interruptions were observed. Electron cooling proposed to increase the luminosity of the RHIC collider for heavy ion beam energies below 10 GeV/nucleon [1] needs a good quality, 0.9-5 MeV electron beam. Preliminary design studies indicate that the scheme of the Recycler's electron cooler at FNAL is suitable for low-energy RHIC cooling and most parts of the cooler can be re-used after the end of the Tevatron Run II. To analyze issues related to the generation of the electron beam in the energy recovery mode and to gain experience with the beam transport at lower beam energy, a dedicated study was performed at FNAL with a beam run through a short beam line (so called U-bend). This report summarizes our findings and observations in the course of the measurements.

43 PARTICLE ACCELERATORS↗

Dual Energy Electron Storage Ring Cooler Design for Relativistic Ion Beams

Collider experiments demand small beam emittances in order to achieve high luminosity. For light particles such as electrons, there exists a natural synchrotron radiation damping resulting in low emittance beams at equilibrium. In the case of heavy particle beams such as proton or ion beams, there is no significant synchrotron radiation damping effect and some cooling mechanism is needed to get to low emittance beams. A dual energy storage ring cooler is a novel concept proposed to cool hadron beams at higher energies. The design consists of two rings: a low energy ring and a high energy ring connected by the energy recovering linac (ERL) that provides the necessary energy difference. The low energy ring has an electron cooler where the cooling interaction takes place between the electron and hadron beams whereas electron beam going through the high energy ring undergoes synchrotron radiation damping. In this document, we present a possible design of a dual energy storage ring-based electron cooler for high energy proton beam cooling suitable for the Electron Ion Collider (EIC) to be built at Brookhaven National laboratory (BNL). A special feature of a dual energy storage ring cooler design is that the electron beam energy in the low energy section must be tuned to match the hadron beam velocity in the cooling section, and the electron beam energy in the high energy section is chosen to provide an adequate synchrotron radiation damping. In addition, the ring optics design is carried out considering chromaticity correction, dynamic aperture, momentum aperture, beam lifetime, radiation damping and the intrabeam scattering effect. Finally, the cooling performance is simulated for 275 GeV proton beams at the top energy of the EIC. In such a collider it is desirable to cool the hadron beams to balance the emittance growth rates due to intra-beam scattering (IBS) to maintain a high luminosity during the collision runs. In such a situation, a dual energy storage ring based cooler could be a practical approach to be used for hadron beam cooling.

Dhital, Bhawin↗

Performance study of a novel dew point evaporative cooler in the climate of central Europe using building simulation tools

This paper presents the performance research of a hybrid air conditioning system (System II) equipped with novel dew point evaporative cooler (DPIEC) for a retail building located in temperate climatic conditions. The new cooler has a dedicated, adaptable structure that maximizes its performance in the climate conditions of central Europe. The unit can operate as a typical regenerative air cooler when outdoor air is drier than indoor air, it can operate as a counter-flow heat recovery unit when indoor conditions are more dry than outdoor and it can operate as a combination of both arrangements. The year-round, hourly-stepped building energy simulations were carried-out using a prognostic tool of energy consumption. The novel dew point evaporative cooler application potential was established using the black-box model based on regression equations was established based on experimental tests on a prototype of novel DPIEC. The hybrid system operation was compared to the typical air handling unit equipped with a standard energy wheel for heat recovery (System I). Presented research shows that DPIEC can cover about 95% of total cooling loads while the energy wheel covers only 9% of total cooling load. System II allows us to save 65% of seasonal electricity consumption comparing to System I. It comes from the fact that during most of the cooling season DPIEC is in operation and it covers most of the cooling loads without the need to switch the chilled water system.

Air conditioning↗

Thermosyphon Cooler Hybrid System for Water Savings in an Energy-Efficient HPC Data Center: Results from 24 Months and the Impact on Water Usage Effectiveness

In August 2016, the National Renewable Energy Laboratory (NREL) installed a thermosyphon hybrid cooling system to reduce water usage in its already extremely energy-efficient High-Performance Computing (HPC) Data Center. In its first year of use, the system saved 4,400 m3 (1.16 million gal) of water, and 7,950 m3 (2.10 million gal) during a 2-year period, cutting the use of water in the data center by about one-half. NREL's 930-m2 (10,000-ft2) HPC Data Center is often called the most energy-efficient data center in the world: it has achieved a trailing 12-month average power usage effectiveness of 1.034, and it features a chiller-less design, component-level warm-water liquid cooling, and waste heat capture and reuse. NREL considered the amount of water used by the cooling towers to be counter to the laboratory's sustainability mission, so a team of researchers from NREL, Sandia National Laboratories (Sandia), and Johnson Controls integrated the BlueStream thermosyphon cooler (TSC) - an advanced dry cooler that uses refrigerant in a passive cycle to dissipate heat - on the roof of NREL's Energy Systems Integration Facility, the building that houses the HPC Data Center. In combination with the existing cooling towers, the TSC forms an extremely water- and cost-efficient cooling system. In its first year of operation, on-site water usage effectiveness (WUE) was 0.70 L/kWh. In comparison, the WUE would be 1.27 L/kWh if NREL had continued using only heat-recovery and cooling towers. This on-site water savings was accomplished without negatively impacting the energy-efficient operation of the HPC Data Center. The TSC system technology has the potential for application in data centers around the world, and it is currently being implemented by Sandia. center by about one-half. NREL's 930-m2 (10,000-ft2) HPC Data Center is often called the most energy-efficient data center in the world: it has achieved a trailing 12-month average power usage effectiveness of 1.034, and it features a chiller-less design, component-level warm-water liquid cooling, and waste heat capture and reuse. NREL considered the amount of water used by the cooling towers to be counter to the laboratory's sustainability mission, so a team of researchers from NREL, Sandia National Laboratories (Sandia), and Johnson Controls integrated the BlueStream thermosyphon cooler (TSC) - an advanced dry cooler that uses refrigerant in a passive cycle to dissipate heat - on the roof of NREL's Energy Systems Integration Facility, the building that houses the HPC Data Center. In combination with the existing cooling towers, the TSC forms an extremely water- and cost-efficient cooling system. In its first year of operation, on-site water usage effectiveness (WUE) was 0.70 L/kWh. In comparison, the WUE would be 1.27 L/kWh if NREL had continued using only heat-recovery and cooling towers. This on-site water savings was accomplished without negatively impacting the energy-efficient operation of the HPC Data Center. The TSC system technology has the potential for application in data centers around the world, and it is currently being implemented by Sandia.

97 MATHEMATICS AND COMPUTING↗

Low-Cost, Accessible Vaccine Cooler Options

In response to cold chain management requirements for COVID-19 vaccines, Los Alamos National Laboratory has investigated, built, and demonstrated viability for different cryogenic storage options. With ease-of-access and affordability in mind, these cooler units have been built using commercial off-the-shelf (COTS) components. The team was also able to design a testing method for evaluating the performance of the different vaccine cooler options as part of the Technology Evaluation and Demonstration program. The tested cooler units demonstrated compatibility with either dry ice or liquid nitrogen as the cryogen, along with several commercial solvents. This compatibility demonstration would potentially offer sufficient flexibility for temperature control continuity. Next steps are to investigate industry interest in supporting field testing of the cooler units.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical Properties of Wigglers for EIC Ring Electron Cooler

Electron Ion Collider (EIC) requires cooling of protons at top energy (275 GeV) to achieve the average design luminosity. Such a cooler must be capable of counteracting an IBS-driven emittance growth in proton bunches. The Ring Electron Cooler (REC) is a candidate for the EIC top energy cooler. The REC is a non-magnetized RF-based 150 MeV electron cooler, in which electrons are kept in the storage ring and re-utilized for several million turns. The REC is equipped with 18 damping wigglers, which keep electrons’ emittance constant by counteracting both electrons’ IBS and a proton electron beam-beam scattering happening in the cooling section. These wigglers operate at a relatively low energy but must have a rather high field to provide the required radiation cooling of electrons. As a result of this unique range of parameters, the wigglers’ optics exhibits interesting features The actual design parameters of the wigglers will be finalized in the REC lattice optimization.

43 PARTICLE ACCELERATORS↗

ULSD and B20 Hydrocarbon Impacts on EGR Cooler Performance and Degradation

Exhaust gas recirculation (EGR) cooler fouling has emerged as an important issue in diesel engine development. Uncertainty about the level of impact that fuel chemistry may have upon this issue has resulted in a need to investigate the cooler fouling process with emerging non-traditional fuel sources to gage their impact on the process. This study reports experiments using both ultra-low sulfur diesel (ULSD) and 20% biodiesel (B20) at elevated exhaust hydrocarbon conditions to investigate the EGR cooler fouling process. The results show that there is little difference between the degradation in cooler effectiveness for ULSD and B20 at identical conditions. At lower coolant temperatures, B20 exhibits elevated organic fractions in the deposits compared with ULSD, but this does not appear to lead to incremental performance degradation under the conditions studied. Comparisons with a previous study conducted at low HC levels shows that the presence of increased volatiles in the deposit does not impact the degradation in effectiveness significantly. Moreover, the effectiveness loss divided by the deposit mass gain for both low- and high-HC conditions seems to indicate that the HC fraction in the deposit does not significantly alter the overall thermal properties of the deposit layer.

33 ADVANCED PROPULSION SYSTEMS↗

Radiation cooler for 10 micrometer wavelength engineering model receiver model no. 7172, serial no. 201

The design, fabrication, and testing of a radiative cooler are described. This cooler is an engineering model suitable for bench testing in the laboratory as a part of the 10-micrometer wavelength engineering model receiver, and conforms to the standard radiative cooler configuration, except that the inner stage and its support system were redesigned to accommodate the larger, heavier SAT detector. This radiative cooler will cool the detector to cryogenic temperature levels when the receiver is in a space environment or in a suitable thermal vacuum chamber. Equipment specifications are given along with the results of thermal tests, vibration tests, and electrical integrity tests.

Source record↗

A review of the NASA/OAST cryogenic coolers technology program

Low and ultra low temperature cryogenic cooler systems for future space missions include mechanical, solid cryogen, gas adsorption, superfluid helium, helium-3, and magnetic (adiabatic demagnetization) coolers. Operating lifetimes required vary from a few weeks for a Shuttle/Spacelab mission to as long as nine years for missions to the outer planets. Temperature requirements vary from tens to tenths of kelvin. At the higher temperature, cooling loads for detectors, instruments and associated shields may be as high as 15 watts. The general requirements for low and ultra low temperature and techniques that can be employed to achieve these temperatures at expected heat loads are discussed. The NASA Centers involved in the R & T efforts and the type of cooler systems on which they are focusing their effort are considered as well as the thrust of R & T effort for each cooler type. Projected missions that will use the technology are identified.

Lundholm, J. G., Jr.↗

Preliminary design trade-offs for a multi-mission stored cryogen cooler

Preliminary design studies were performed for a multi-mission solid cryogen cooler having a wide range of application for both the shuttle sortie and free flyer missions. This multi-mission cooler (MMC) is designed to be utilized with various solid cryogens to meet a wide range of instrument cooling from 10 K (with solid hydrogen) to 90 K. The baseline cooler utilizes two stages of solid cryogen and incorporates an optional, higher temperature third stage which is cooled by either a passive radiator or a thermoelectric cooler. The MMC has an interface which can accommodate a wide variety of instrument configurations. A shrink fit adapter is incorporated which allows a drop-in instrument integration. The baseline design provides cooling of approximately 1 watt over a 60 to 100 K temperature range and about 0.5 watts from 15 to 60 K for a one year lifetime. For low cooling loads and with use of the optional radiator shield, cooling lifetimes as great as 8 years are predicted.

Sherman, A.↗

Recent developments in Stirling and pulse tube coolers for spacecraft applications

Recent progress toward the development of light weight, long life coolers is presented. In particular, programs underway in the United States to develop Stirling cycle coolers and pulse tube coolers are described. The potential availability of reliable, long lifetime coolers for space applications is discussed.

Castles, Stephen↗

Optimal digital control of a Stirling cycle cooler

This short paper describes work in progress on the conceptual design of a control system for a cryogenic cooler intended for use aboard spacecraft. The cooler will produce 5 watts of cooling at 65 K and will be used to support experiments associated with the following: earth observation; atmospheric measurements; infrared, x-ray, and gamma-ray astronomy; and magnetic field characterization. The cooler has been designed and constructed for NASA/GSFC by Philips Laboratories and is described in detail. The cooler has a number of unique design features intended to enhance long life and maintenance free operation in space including use of the high efficiency Stirling thermodynamic refrigeration cycle, linear magnetic motors, clearance-seals, and magnetic bearings. The proposed control system design is based on optimal control theory and is targeted for custom integrated circuit implementation. The resulting control system will meet the following mission requirements: efficiency, reliability, optimal thermodynamic, electrical, and mechanical performance; freedom from operator intervention; light weight; and small size.

Feeley, J.↗

Vacuum Camera Cooler

Acquiring cheap, moving video was impossible in a vacuum environment, due to camera overheating. This overheating is brought on by the lack of cooling media in vacuum. A water-jacketed camera cooler enclosure machined and assembled from copper plate and tube has been developed. The camera cooler (see figure) is cup-shaped and cooled by circulating water or nitrogen gas through copper tubing. The camera, a store-bought "spy type," is not designed to work in a vacuum. With some modifications the unit can be thermally connected when mounted in the cup portion of the camera cooler. The thermal conductivity is provided by copper tape between parts of the camera and the cooled enclosure. During initial testing of the demonstration unit, the camera cooler kept the CPU (central processing unit) of this video camera at operating temperature. This development allowed video recording of an in-progress test, within a vacuum environment.

Laugen, Geoffrey A.↗

Sorption coolers using a continuous cycle to produce 20 K for the Planck flight mission

Two sorption coolers using hydrogen as the working fluid are currently being fabricated and assembled for flight delivery by the Jet Propulsion Laboratory (JPL). Being vibration free, scalable and with the capability for the cold end to be remotely located from the warm spacecraft are the major advantages of this class of cryo-coolers. These systems have been designed to provide a total cooling capacity (per cooler) of 1 W at a cold end temperature less than 19 K. They will be used for the Planck surveyor mission (2007 launch). In this paper we present the level Of maturity of the hydrogen sorption cooler technology at JPL by describing the design and how it has been validated at the subsystem and system levels.