The achievement of low contact resistance to indium phosphide: The roles of Ni, Au, Ge, and combinations thereof

We have investigated the electrical and metallurgical behavior of Ni, Au-Ni, and Au-Ge-Ni contacts on n-InP. We have found that very low values of contact resistivity rho(sub c) in the E-7 omega-sq cm range are obtained with Ni-only contacts. We show that the addition of Au to Ni contact metallization effects an additional order of magnitude reduction in rho(sub c). Ultra-low contact resistivities in the E-8 omega-sq cm range are obtained with both the Au-Ni and the Au-Ge-Ni systems, effectively eliminating the need for the presence of Ge in the Au-Ge-Ni system. The formation of various nickel phosphides at the metal-InP interface is shown to be responsible for the observed rho(sub c) values in the Ni and Au-Ni systems. We show, finally, that the order in which the constituents of Au-Ni and Au-Ge-Ni contacts are deposited has a significant bearing on the composition of the reaction products formed at the metal-InP interface and therefore on the contact resistivity at that interface.

Fatemi, Navid S.↗

Thermal Contact Resistance

Thermal, surface, and deformation analyses for predicting thermal contact resistance for metal surface characteristics in vacuum and fluid environment

METAL SURFACE↗

Contact-resistance process cliff

Several approaches were investigated to obtain a measure of the quality of the contact resistance between metal and a diffused or polysilicon layer. These approaches have included the use of both short and very long contact strings as well as arays of contacts with different sizes to determine the contact resistance process cliff. Results from these approaches are discussed.

Pina, C. A.↗

Evaluation of Contact Resistance and Fin Effectiveness of Enhanced, Brazed "Dogbone" Fin and Serpentine Tube Heat Exchangers for Air Conditioning and Heat Pump Applications

The energy consumption due to air conditioning is projected to increase by 1.3 and 4.5 times by 2050 compared to 2010 for members and non-members of the Organization of Economic Coordination and Development (OECD), respectively. Greenhouse Gas (GHG) emissions must be carefully managed to minimize their hazardous contribution to climate change. Air conditioners (AC) and heat pumps (HP) contribute with direct GHG emissions through systemic refrigerant leakage, which consequently degrades the system’s performance and therefore increases its indirect GHG emissions as well. To address this issue, the goals of new systems include minimizing leakage risk, using low global warming potential (GWP) refrigerants such as natural refrigerants, and increasing system efficiency. This paper presents part of the efforts in the development of a brazed “dogbone” fin to continuous serpentine tube heat exchanger (HX) for AC/HP applications. The main advantages of such technology are: 1) The potential to reduce 90% or more of the tube return-bends brazed joints compared to conventional tube-fin heat exchangers, thus minimizing leakage vulnerability, enabling the use of natural refrigerants like Propane and Ammonia that carry other concerning risks of flammability and toxicity ; and 2) The brazed fin to the tube joints should yield very low contact resistance. In order to quantify and estimate the impacts of contact resistance and fin effectiveness, a numerical-experimental study is investigated. The novel enhanced brazed “dog-bone” fin is compared to an equivalent pressure expanded fin. The results showed that the expanded fin has consistently greater effective heat transfer but greater contact resistance as well. Furthermore, the brazed fins have up to 20% lower pressure drop. The trade-off comparison shows that the thermal-hydraulic ratio between the two fins is equivalent for air velocities below 2m/s; for greater velocities, however, the expanded fin is favored since it has less fin efficiency penalty. For HVAC&R applications, the air velocities are typically low which makes the proposed technology competitive and a viable option in the pursuit of refrigerant leakage reduction.

30 DIRECT ENERGY CONVERSION↗

Contact Resistance of Carbon–Li x (Ni,Mn,Co)O 2 Interfaces

Abstract Electronic resistance in lithium‐ion battery positive electrodes is typically attributed to the bulk resistance of the active material and the network resistance of the carbon additive. Expected overpotentials from these bulk components are minimal relative to that from charge‐transfer resistance. However, literature reports show that cell overpotentials are often much more sensitive to conductive additives than the expected level from bulk or percolating‐network transport. This discrepancy motivated a detailed examination of the contact resistance between the active material and conductive additive. The contact and bulk resistances are simultaneously measured using dense bar samples of lithium‐layered oxides (Li x Ni 1 /3 Mn 1/3 Co 1/3 O 2 and Li x Ni 0.5 Mn 0.3 Co 0.2 O 2 ) in contact with carbon black. It is found that the contact resistance dominates the overall electronic resistance when the length scale is smaller than millimeters; after correcting for contact effects, bulk conductivity of layered oxides is determined to be orders‐of‐magnitude higher than previously reported. In porous electrodes, it is found from three‐electrode electrochemical impedance spectroscopy that the carbon content most heavily influences the low‐frequency regime (≈0.01 Hz), as opposed to the high frequency (>10 3 Hz) regime expected from electronic percolating properties. Constriction effects within the layered oxide are identified as the dominant mechanism for contact resistance and its implication is investigated for porous electrodes.

Kuo, Jimmy Jiahong↗

Measurements of the effects of thermal contact resistance on steady state heat transfer in phosphoric-acid fuel cell stack

The influence of the thermal contact resistance on the heat transfer between the electrode plates, and the cooling system plate in a phosphoric-acid fuel-cell stack was experimentally investigated. The investigation was conducted using a set-up that simulates the operating conditions prevailing in a phosphoric acid fuel-cell stack. The fuel-cell cooling system utilized three types of coolants, water, engine oil, and air, to remove excess heat generated in the cell electrode and to maintain a reasonably uniform temperature distribution in the electrode plate. The thermal contact resistance was measured as a function of pressure at the interface between the electrode plate and the cooling system plate. The interface pressure range was from 0 kPa to 3448 kPa, while the Reynolds number for the cooling limits varied from 15 to 79 for oil, 1165 to 6165 for water, and 700 to 6864 for air. Results showed that increasing the interface pressure resulted in a higher heat transfer coefficient.

Abdul-Aziz, Ali↗

Formula Gives Better Contact-Resistance Values

Lateral currents in contact strips taken into account. Four-terminal test structures added to intergrated circuits to enable measurement of interfacial resistivities of contacts between thin conducting layers. Thin-film model simplified quasi-two-dimensional potential model that accounts adequately for complicated three-dimensional, nonuniform current densitites. Effects of nonuniformity caused by lateral current flow in strips summarized in equivalent resistance Rs and voltage Vs.

Lieneweg, Udo↗

Contact resistivities of sputtered TiN and Ti-TiN metallizations on solar-cell-type-silicon

The resistivities of TiN and Ti-TiN contacts on a shallow junction solar-cell-type silicon substrate have been determined by the method of the transmission line model. The contacts investigated are shown to be suitable for standard solar cells from an electrical point of view. Contact resistivity values of the order of 0.0001 ohm/sq cm as obtained for the n(+)Si-TiSi2-TiN contact system may be acceptable for concentrations up to 100 times, but lower values are necessary beyond this point.

Maenpaa, M.↗

Low Ohmic contact resistance and high on/off ratio in transition metal dichalcogenides field-effect transistors via residue-free transfer

Beyond-silicon technology demands ultrahigh performance field-effect transistors. Transition metal dichalcogenides provide an ideal material platform, but the device performances such as the contact resistance, on/off ratio and mobility are often limited by the presence of interfacial residues caused by transfer procedures. Here, we show an ideal residue-free transfer approach using polypropylene carbonate with a negligible residue coverage of ~0.08% for monolayer MoS 2 at the centimetre scale. By incorporating a bismuth semimetal contact with an atomically clean monolayer MoS 2 field-effect transistor on hexagonal boron nitride substrate, we obtain an ultralow Ohmic contact resistance of ~78 Ω µm, approaching the quantum limit, and a record-high on/off ratio of ~10 11 at 15 K. Further, such an ultra-clean fabrication approach could be the ideal platform for high-performance electrical devices using large-area semiconducting transition metal dichalcogenides.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Tape-in-tape-out (TITO): a new approach for in-situ contact resistance measurements in high temperature superconducting CORC® cables

One of the ongoing development challenges with ReBCO high-temperature superconducting (HTS) cables is normal zone initiation and local heating, which is associated with over-critical current flowing through and around local performance reductions in individual tapes. Although inter-tape contact resistances are well-reported for individual tapes and HTS cables, these measurements are a challenge in CORC® cables as current percolates through much of the cable. In this work, developments in tape-in-tape-out (TITO) automated individual tape powering experiments are presented, and a simplified modeling approach for current percolation in CORC® cables is developed. An optimization is formulated to fit the model parameters to a large set of TITO experiments on a single cable, allowing the layer-dependent inter-tape contact resistance to be extracted. Measurements are presented and discussed for a straight CORC® cable and a cable bent to a 152 mm and 76 mm radius. The approach provides both quantitative insight and facilitates better understanding of current sharing phenomena in HTS cables.

Teyber, Reed↗