Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Direct evidence of interaction-induced Dirac cones in a monolayer silicene/Ag(111) system

Silicene, analogous to graphene, is a one-atom-thick 2D crystal of silicon, which is expected to share many of the remarkable properties of graphene. The buckled honeycomb structure of silicene, along with enhanced spin-orbit coupling, endows silicene with considerable advantages over graphene in that the spin-split states in silicene are tunable with external fields. Although the low-energy Dirac cone states lie at the heart of all novel quantum phenomena in a pristine sheet of silicene, a hotly debated question is whether these key states can survive when silicene is grown or supported on a substrate. Here we report our direct observation of Dirac cones in monolayer silicene grown on a Ag(111) substrate. By performing angle-resolved photoemission measurements on silicene(3 × 3)/Ag(111), we reveal the presence of six pairs of Dirac cones located on the edges of the first Brillouin zone of Ag(111), which is in sharp contrast to the expected six Dirac cones centered at the K points of the primary silicene(1 × 1) Brillouin zone. Our analysis shows clearly that the unusual Dirac cone structure we have observed is not tied to pristine silicene alone but originates from the combined effects of silicene(3 × 3) and the Ag(111) substrate. Our study thus identifies the case of a unique type of Dirac cone generated through the interaction of two different constituents. The observation of Dirac cones in silicene/Ag(111) opens a unique materials platform for investigating unusual quantum phenomena and for applications based on 2D silicon systems.

36 MATERIALS SCIENCE↗

SU-E-T-370: Measurement of Conical Cone Output Factors for the Varian Edge Linear Accelerator

Purpose: To quantify the impact of detector type, SSD/depth, and intermediate reference on conical cone output factor (OF) measurements for the Varian Edge linac. Methods: OF's for 4, 5, 7.5, 10, 12.5, 15, and 17.5 mm diameter cones relative to 10cmx10cm field were measured for the 6X FFF and 10X FFF energies, with jaws set to 5cmx5cm. Measurements were performed with an Edge diode (0.8mmx0.8mmx0.03mm WxLxT), stereotatic diode SFD, photon diode, CC01 and pinpoint chambers (2mm diameter for both). 95cm SSD/5cm depth were used in a water tank. For the measurement with diodes, OF's were cross-referred to CC13 ion chamber measurements with 3cmx3cm field, as recommended, to help mitigate the energy variation in diode response with field size. Results were compared to the representative data from Varian measured with Edge detector. With SFD, OF's at 98.5cm SSD/1.5cm depth and 90cm SSD/10cm depth were also measured. Results: OF's measured with the Edge detector matched within 1.3% (max diff) with the representative data from Varian. For the SFD, OF's matched within 1.3% for the 4, 5 and 17.5 mm cones and within 3.7% for the other cones. OF's with photon diode were within 1.3% except for the 4 and 5 mm cones where they were 8.1% and 3.7%, respectively. OF's for the CC01 and pinpoint chamber deviated up to 36% and 44%, respectively for the 4 mm cone. OF's after intermediate reference with 3cmx3cm field changed by 3.7% for SFD, 0.8% for photon diode, and 0.6% for Edge detector. OF's at 98.5cm SSD/1.5cm depth were 10.8% higher than that at 95cm SSD/5cm depth, and OF's at 90cm SSD/1.5cm depth were 7.5% lower. Conclusion: OF's measured with the Edge detector appear to be reliable. CC01 and pinpoint chambers do not appear suitable for measuring the small cone OF's. SSD/depth affects OF measurements significantly.

07 ISOTOPE AND RADIATION SOURCES↗

HopBox: An image analysis pipeline to characterize hop cone morphology

Abstract Hop cone morphology can influence picking and drying ability, and color can impact consumer preference and may be indicative of quality. However, these characteristics are not generally evaluated in hop breeding programs due to the tedious nature of trait quantification and the extensive variation among cones within a genotype. We developed the HopBox, which is a simply constructed light box with a camera mount, and a publicly available image processing pipeline that identifies hop cones within color‐corrected images, reads a QR code within the image, and outputs data on hop cone length, width, area, perimeter, openness, weight, color, and density. The trained model was applied to images of 500 cones each from 15 replicated advanced hop genotypes from the USDA‐ARS breeding program in Prosser, Washington. Analysis of variance revealed significant ( p < 0.001) differences between genotypes for all traits measured, enabling breeders to discriminate between genotypes for selection purposes. Broad sense heritability for all traits ranged from 0.23 to 0.59. A random sampling of hop cones from the complete dataset revealed that imaging only 5–10 cones adequately captured genotypic variation and provided acceptable rank correlations ( r s > 0.75); however, increasing the sample size to 30 provided optimal precision. Instructions for constructing a HopBox and the code for the analysis pipeline are publicly available online and have wide applicability for hop breeding and research.

Altendorf, Kayla R.↗

Exploring the holographic entropy cone via reinforcement learning

We develop a reinforcement learning algorithm to study the holographic entropy cone. Given a target entropy vector, our algorithm searches for a graph realization whose min-cut entropies match the target vector. If the target vector does not admit such a graph realization, it must lie outside the cone, in which case the algorithm finds a graph whose corresponding entropy vector most nearly approximates the target and allows us to probe the location of the facets. For the N = 3 cone, we confirm that our algorithm successfully rediscovers monogamy of mutual information beginning with a target vector outside the holographic entropy cone. We then apply the algorithm to the N = 6 cone, analyzing the 6 mystery extreme rays of the subadditivity cone from [1] that satisfy all known holographic entropy inequalities yet lacked graph realizations. We found realizations for 3 of them, proving they are genuine extreme rays of the holographic entropy cone, while providing evidence that the remaining 3 are not realizable, implying unknown holographic inequalities exist for N = 6.

AdS-CFT correspondence↗

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image of the patient is needed for image-guidance procedures. The authors previously developed an algorithm for image reconstruction from nontruncated data of an object that is completely within the reverse helix. The purpose of this work is to develop an image reconstruction approach for reverse helical CBCT of a long object that extends out of the reverse helix and therefore constitutes data truncation. Methods: The proposed approach comprises of two reconstruction steps. In the first step, a chord-based backprojection-filtration (BPF) algorithm reconstructs a volumetric image of an object from the original cone-beam data. Because there exists a chordless region in the middle of the reverse helix, the image obtained in the first step contains an unreconstructed central-gap region. In the second step, the gap region is reconstructed by use of a Pack-Noo-formula-based filteredbackprojection (FBP) algorithm from the modified cone-beam data obtained by subtracting from the original cone-beam data the reprojection of the image reconstructed in the first step. Results: The authors have performed numerical studies to validate the proposed approach in image reconstruction from reverse helical cone-beam data. The results confirm that the proposed approach can reconstruct accurate images of a long object without suffering from data-truncation artifacts or cone-angle artifacts. Conclusions: They developed and validated a BPF-FBP tandem algorithm to reconstruct images of a long object from reverse helical cone-beam data. The chord-based BPF algorithm was utilized for converting the long-object problem into a short-object problem. The proposed approach is applicable to other scanning configurations such as reduced circular sinusoidal trajectories.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A virtual source model for Kilo-voltage cone beam CT: Source characteristics and model validation

Purpose: The purpose of this investigation was to study the source characteristics of a clinical kilo-voltage cone beam CT unit and to develop and validate a virtual source model that could be used for treatment planning purposes. Methods: We used a previously commissioned full Monte Carlo model and new bespoke software to study the source characteristics of a clinical kilo-voltage cone beam CT (CBCT) unit. We identified the main particle sources, their spatial, energy and angular distribution for all the image acquisition presets currently used in our clinical practice. This includes a combination of two energies (100 and 120 kVp), two filters (neutral and bowtie), and eight different x-ray beam apertures. We subsequently built a virtual source model which we validated against full Monte Carlo calculations. Results: We found that the radiation output of the clinical kilo-voltage cone beam CT unit investigated in this study could be reproduced with a virtual model comprising of two sources (target and filtration cone) or three sources (target, filtration cone and bowtie filter) when additional filtration was used. With this model, we accounted for more than 97% of the photons exiting the unit. Each source in our model was characterised by a origin distribution in both X and Y directions, a fluence map, a single energy spectrum for unfiltered beams and a two dimensional energy spectrum for bowtie filtered beams. The percentage dose difference between full Monte Carlo and virtual source model based dose distributions was well within the statistical uncertainty associated with the calculations ( {+-} 2%, one standard deviation) in all cases studied. Conclusions: The virtual source that we developed is accurate in calculating the dose delivered from a commercial kilo-voltage cone beam CT unit operating with routine clinical image acquisition settings. Our data have also shown that target, filtration cone, and bowtie filter sources needed to be all included in the model in order to accurately replicate the dose distribution from the clinical radiation beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-122: Dosimetric Comparison Between Cone, HDMLC and MicroMLC for the Treatment of Trigeminal Neuralgia

Purpose: The purpose of this work was to evaluate the dosimetric characteristics of three collimation systems, 5mm circular cone (Brainlab) and square fields of 5mm with HDMLC (Varian) and microMLC Moduleaf, Siemens) for trigeminal neuralgia treatment. Methods: A TPS Iplan v4.5 BrainLAB was used to do treatment plans for each collimations system in a square solid water phantom with isocenter at 5cm depth. Single field and treatment plan including 11 arcs with fix field and 100° gantry range was made for each collimation systems. EBT3 films were positioned at isocenter in a coronal plane to measured dose distribution for all geometries. Films were digitized with a Vidar DosimetryPro Red scanner with a resolution of 89dpi and RIT113v6.1 software was used for analysis. Penumbra region (80%–20%), FWHM and dose percentage at 5mm and 10mm from CAX were determined. All profiles were normalized at CAX. Results: For single beam the penumbra (FWHM) was 1.5mm (5.3mm) for the cone, 1.9mm (5.5mm) for HDMLC and 1.8mm (5.4mm) for the microMLC. Dose percentage at 5mm was 6.9% for cone, 12.5% for HDMLC and 8.7% for the microMLC. For treatment plan the penumbra (FWHM) was 2.58mm (5.47mm) for the cone, 2.8mm (5.84mm) for HDMLC and 2.58mm (6.09mm) for the microMLC. Dose perecentage at 5mm was 13.1% for cone, 16.1% for HDMLC, 15.2% for the microMLC. Conclusion: The cone has a dose falloff larger than the microMLC and HDMLC, by its reduced penumbra, this translates into better protection of surrounding healthy tissue, however, the microMLC and HDMLC have similar accuracy to cone.

60 APPLIED LIFE SCIENCES↗

Analytic image reconstruction from partial data for a single-scan cone-beam CT with scatter correction

Purpose: A beam-blocker composed of multiple strips is a useful gadget for scatter correction and/or for dose reduction in cone-beam CT (CBCT). However, the use of such a beam-blocker would yield cone-beam data that can be challenging for accurate image reconstruction from a single scan in the filtered-backprojection framework. The focus of the work was to develop an analytic image reconstruction method for CBCT that can be directly applied to partially blocked cone-beam data in conjunction with the scatter correction. Methods: The authors developed a rebinned backprojection-filteration (BPF) algorithm for reconstructing images from the partially blocked cone-beam data in a circular scan. The authors also proposed a beam-blocking geometry considering data redundancy such that an efficient scatter estimate can be acquired and sufficient data for BPF image reconstruction can be secured at the same time from a single scan without using any blocker motion. Additionally, scatter correction method and noise reduction scheme have been developed. The authors have performed both simulation and experimental studies to validate the rebinned BPF algorithm for image reconstruction from partially blocked cone-beam data. Quantitative evaluations of the reconstructed image quality were performed in the experimental studies. Results: The simulation study revealed that the developed reconstruction algorithm successfully reconstructs the images from the partial cone-beam data. In the experimental study, the proposed method effectively corrected for the scatter in each projection and reconstructed scatter-corrected images from a single scan. Reduction of cupping artifacts and an enhancement of the image contrast have been demonstrated. The image contrast has increased by a factor of about 2, and the image accuracy in terms of root-mean-square-error with respect to the fan-beam CT image has increased by more than 30%. Conclusions: The authors have successfully demonstrated that the proposed scanning method and image reconstruction algorithm can effectively estimate the scatter in cone-beam projections and produce tomographic images of nearly scatter-free quality. The authors believe that the proposed method would provide a fast and efficient CBCT scanning option to various applications particularly including head-and-neck scan.

60 APPLIED LIFE SCIENCES↗

Performance and emissions characteristics of a lighting cone for charcoal stoves

We report a lighting cone is a simple metal cone placed on the charcoal bed during ignition to increase draft. Many traditional charcoal-burning stoves are difficult to light due to poor draft through the fuel bed, so lighting cones are used as an inexpensive accessory to help with charcoal ignition. The goal of this work was to determine the validity of using a lighting cone to decrease the ignition time of traditional Haitian charcoal stoves, and evaluate its impact on stove emissions and fuel consumption during the typically inefficient and slow ignition phase. We found that the lighting cone successfully reduced ignition time by over 50%. Due to a more efficient, shorter ignition stage, charcoal consumption during ignition was reduced by over 40% and carbon monoxide was reduced by over 50%. This suggests that lighting cones are a viable and beneficial accessory for aiding ignition in shallow-bed charcoal stoves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modification of the Loss Cone for Energetic Particles in the Earth's Inner Magnetosphere

The behavior of energetic particles in the Earth's dipole and stretched magnetic-field models is explored with a focus on the shift of the atmospheric loss cone away from the magnetic-field direction and on non-adiabatic behavior occurring when the particle gyroradius becomes comparable with the gradient scale length of the local magnetic field. It is shown that the equatorial loss cone is aberrated away from the magnetic-field direction (pitch angle of 0°) by the perpendicular drift of a charged particle (which is referred to as the “Mozer transform” described in Mozer (1966, https://doi.org/10.1029/JZ071i011p02701). It is found that the Mozer coordinate transformation in pitch-angle/gyrophase-angle space better organizes the behavior of bounce times, mirror altitudes, drift speeds, and first adiabatic invariant. It also describes the loss-cone shift accurately for a certain range of values of the adiabaticity parameter ϵ, defined by the ratio of the particle gyroradius to the local radius of curvature of the magnetic field. For particles with larger ϵ, the Mozer transform (evaluated with the standard gradient-curvature drift) breaks down and the “central trajectory” theory can be used to calculate the angular shift of the loss cone, which now includes an Earthward shift. When ϵ becomes relatively large, stochastic field line curvature (FLC) scattering occurs: we show the intimate connection between the strength of FLC scattering and the loss-cone shift. Finally, by comparing ion orbits in the dipole and Tsyganenko (Ts89 and Ts04) magnetic fields, we conclude that the loss cone of ring-current ions is significantly modified during geomagnetically active times.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhanced dense attosecond electron bunch generation by irradiating an intense laser on a cone target

By using two-dimensional particle-in-cell simulations, we demonstrate enhanced spatially periodic attosecond electron bunches generation with an average density of about 10n{sub c} and cut-off energy up to 380 MeV. These bunches are acquired from the interaction of an ultra-short ultra-intense laser pulse with a cone target. The laser oscillating field pulls out the cone surface electrons periodically and accelerates them forward via laser pondermotive force. The inner cone wall can effectively guide these bunches and lead to their stable propagation in the cone, resulting in overdense energetic attosecond electron generation. We also consider the influence of laser and cone target parameters on the bunch properties. It indicates that the attosecond electron bunch acceleration and propagation could be significantly enhanced without evident divergency by attaching a plasma capillary to the original cone tip.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AbacusSummit Halo Light Cone Catalogs

This is a set of halo light cone catalogs from the AbacusSummit suite of cosmological N-body simulations (abacussummit.readthedocs.io/). They are a value-added data product provided by post-processing the simulation output. The main application of the halo light cone catalogs is the construction of realistic mock galaxy catalogues and weak lensing maps on the sky. The algorithm (described in Hadzhiyska et al. 2021) associates CompaSO halos from 29 redshift epochs spanning z = 0.1-2.5 with their particles at the time of light-cone crossing. It then records the halo and particle information into an easily accessible product, which can be read with the CompaSO reader. The 25 base resolution boxes at fiducial cosmology have a halo light cone catalog covering an octant of the sky to z approx 0.8 and about 2000 deg2 extending to z approx 2.4. The huge boxes provide light cone information of the full sky until z approx 2.18 and extend further towards the corners of the box (available until z = 2.25). Galaxy mock catalogs on the sky can be generated easily though the AbacusHOD script providing an extended HOD framework (see Yuan et al. 2021, for details), which has been modified to work with the halo light cone catalogs. The available tracers are luminous red galaxies (LRGs), emission-line galaxies (ELGs), and quasi-stellar objects (QSOs).

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of radiosurgery techniques–Cone-based linac radiosurgery vs tomotherapy-based radiosurgery

Performances of radiosurgery of intracranial lesions between cone-based Linac system and Tomotherapy-based system were compared in terms of dosimetry and time. Twelve patients with single intracranial lesion treated with cone-based Linac radiosurgery system from 2005 to 2009 were replanned for Tomotherapy-based radiosurgery treatment. The conformity index, homogeneity index (HI), and gradient score index (GSI) of each case was calculated. The Wilcoxon matched-pair test was used to compare the 3 indices between both systems. The cases with regular target (n = 6) and those with irregular target (n = 6) were further analyzed separately. The estimated treatment time between both systems was also compared. Significant differences were found in HI (p = 0.05) and in GSI (p = 0.03) for the whole group. Cone-based radiosurgery was better in GSI whereas Tomotherapy-based radiosurgery was better in HI. Cone-based radiosurgery was better in conformity index (p = 0.03) and GSI (p = 0.03) for regular targets, whereas Tomotherapy-based radiosurgery system performed significantly better in HI (p = 0.03) for irregular targets. The estimated total treatment time for Tomotherapy-based radiosurgery ranged from 24 minutes to 35 minutes, including 15 minutes of pretreatment megavoltage computed tomography (MVCT) and image registration, whereas that for cone-based radiosurgery ranged from 15 minutes for 1 isocenter to 75 minutes for 5 isocenters. As a rule of thumb, Tomotherapy-based radiosurgery system should be the first-line treatment for irregular lesions because of better dose homogeneity and shorter treatment time. Cone-based Linac radiosurgery system should be the treatment of choice for regular targets because of the better dose conformity, rapid dose fall-off, and reasonable treatment time.

61 RADIATION PROTECTION AND DOSIMETRY↗

Propagation of attosecond electron bunches along the cone-and-channel target

Generation and propagation of attosecond electron bunches along a cone-and-channel target are investigated by particle-in-cell simulation. The target electrons are pulled out by the oscillating electric field of an intense laser pulse irradiating a cone target and accelerated forward along the cone walls. It is shown that the energetic electrons can be further guided and confined by a channel attached to the cone tip. The propagation of these electrons along the channel induces a strong quasistatic magnetic field as well as a sheath electric field since a part of the energetic electrons expands into the surrounding vacuum. The electromagnetic field in turn confines the surface currents. With the cone-and-channel target the energetic electrons can be much better collimated and propagate much farther than that from the classical cone target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initial cone-in-shell fast-ignition experiments on OMEGA

Fast ignition is a two-step inertial confinement fusion concept where megaelectron volt electrons ignite the compressed core of an imploded fuel capsule driven by a relatively low-implosion velocity. Initial surrogate cone-in-shell, fast-ignitor experiments using a highly shaped driver pulse to assemble a dense core in front of the cone tip were performed on the OMEGA/OMEGA EP Laser [T. R. Boehly et al., Opt. Commun. 133, 495 (1997); L. J. Waxer et al., Opt. Photonics News 16, 30 (2005)]. With optimal timing, the OMEGA EP pulse produced up to {approx}1.4 x 10{sup 7} additional neutrons which is a factor of {approx}4 more neutrons than without short-pulse heating. Shock-breakout measurements performed with the same targets and drive conditions demonstrate an intact cone tip at the time when the additional neutrons are produced. Velocity interferometer system for any reflector measurements show that x-rays from the shell's coronal plasma preheat the inner cone wall of thin-walled Au cones, while the thick-walled cones that are used in the integrated experiments are not affected by preheat.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of increased nanostructure cone growth on Cr due to grazing-incidence Ta seed atom deposition in a He plasma

Nanostructure cone growth on chromium during helium plasma exposure in the PISCES-A linear plasma device is found to increase with the deposition of heavy tantalum atoms. Tantalum is found to be especially effective at increasing cone growth if the tantalum is incident on the surface at a grazing angle (~5° or less). Tantalum atoms at grazing incidence are observed to be dominantly deposited at the cone tips, consistent with reduced sputtering of the cone tips and increased cone growth. Monte-Carlo simulations are found to be qualitatively consistent with the experimental observation that grazing-incidence heavy atom deposition on a lighter substrate will tend to increase cone growth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TOWARD AN EMPIRICAL THEORY OF PULSAR EMISSION. IX. ON THE PECULIAR PROPERTIES AND GEOMETRIC REGULARITY OF LYNE AND MANCHESTER'S 'PARTIAL CONE' PULSARS

Lyne and Manchester identified a group of some 50 pulsars they called 'partial cones' which they found difficult to classify and interpret. They were notable for their asymmetric average profiles and asymmetric polarization position angle (PPA) traverses, wherein the steepest gradient (SG) point fell toward one edge of the total intensity profile. Over the last two decades, this population of pulsars has raised cautions regarding the core/cone model of the radio pulsar emission beam which implies a high degree of order, symmetry, and geometric regularity. In this paper, we reinvestigate this population 'partial cone' pulsars on the basis of new single pulse polarimetric observations of 39 of them, observed with the Giant Meterwave Radio Telescope in India and the Arecibo Observatory in Puerto Rico. These highly sensitive observations help us to establish that most of these 'partial cones' exhibit a core/cone structure just as did the 'normal' pulsars studied in the earlier papers of this series. In short, we find that many of these 'partial cones' are partial in the sense that the emission above different areas of their polar caps can be (highly) asymmetric. However, when studied closely we find that their emission geometries are overall identical to a core/double cone structure encountered earlier-that is, with specific conal dimensions scaling as the polar cap size. Further, the 'partial cone' population includes a number of stars with conal single profiles that are asymmetric at meter wavelengths for unknown reasons (e.g., like those of B0809+74 or B0943+10). We find that aberration-retardation appears to play a role in distorting the core/cone emission-beam structure in rapidly rotating pulsars. We also find several additional examples of highly polarized pre- and postcursor features that do not appear to be generated at low altitude but rather at high altitude, far from the usual polar flux tube emission sites of the core and conal radiation.

79 ASTRONOMY AND ASTROPHYSICS↗

MMTF DISCOVERY OF GIANT IONIZATION CONES IN MR 2251-178: IMPLICATIONS FOR QUASAR RADIATIVE FEEDBACK

We report the discovery of giant ionization cones in the 140 kpc nebula around quasar MR 2251-178 based on deep [O III] {lambda}5007/H{beta} and [N II] {lambda}6583/H{alpha} flux ratio maps obtained with the Maryland-Magellan Tunable Filter on the Baade-Magellan 6.5 m Telescope. These cones are aligned with the weak double-lobed radio source observed on smaller scale (<30 kpc). They have an opening angle {approx}120 Degree-Sign {+-} 10 Degree-Sign and subtend {approx}65%-90% of 4{pi} sr, where the uncertainty takes into account possible projection effects. The material in the outer ionization cones is matter-bounded, indicating that all ionizing photons emitted through the cones escape from the system. The quasar ionizing flux is {approx}2-3 times fainter outside of these cones, despite the largely symmetric geometry of the nebula in [O III]. Overall, adding up the contributions from both inside and outside the cones, we find that {approx}65%-95% of the quasar ionizing radiation makes its way out of the system. These results emphasize the need for line ratio maps to quantify the escape fraction of ionizing radiation from quasars and the importance of quasar radiative feedback on the intergalactic medium.

79 ASTRONOMY AND ASTROPHYSICS↗