Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Molybdenum Sleeve Experiments in Fully-Reflected Water-Moderated Triangular-Pitched U(6.90)O 2 Fuel Rod Lattices (1.55 cm Pitch)

The US Department of Energy (DOE) Nuclear Energy Research Initiative funded the design and construction of the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories. The start-up of the experiment facility and the execution of the experiments described here were funded by the DOE Nuclear Criticality Safety Program. The 7uPCX is designed to investigate critical systems with fuel for light water reactors in the enrichment range above 5 % 235 U. The 7uPCX assembly is a water-moderated and -reflected array of aluminum-clad U(6.90 %)O 2 fuel rods. Other critical experiments performed in the 7uPCX assembly are documented in LEU-COMP-THERM-078, LEU-COMP-THERM-080, LEU-COMP-THERM-096, LEUCOMP-THERM-097, LEU-COMP-THERM-101, and LEU-COMP-THERM-102. The purpose of these experiments was to measure the effects of molybdenum in nearly-critical systems. The molybdenum was introduced into the fuel arrays as tubular sleeves that surrounded some of the fuel rods in the fuel arrays measured. Four hundred molybdenum tubes nominally 12.7 mm outside diameter, 498 mm long, with 0.762 mm wall thickness were provided for the experiments by the Institut de Radioprotection et de Sûreté Nucléaire (IRSN). Small polyethylene adapters at each end of the tubes were used to center each tube on a fuel rod in the assembly. The critical experiments were done using a set of triangular-pitched grid plates fabricated for these experiments. The grid plate set accommodated a fuel array of a total of 1261 fuel rod positions on a pitch of 0.610 in (1.5494 cm) in a series of 20 hexagonal rings surrounding the central fuel rod. The fuel used in these experiments was fabricated using unirradiated 6.90 % enriched UO 2 fuel pellets from fuel elements designed to be used in the internal nuclear superheater section of the Pathfinder boiling water reactor operated in South Dakota by the Northern States Power Company in the 1960s. The fuel elements were obtained from The Pennsylvania State University where they had been stored for many years. The fuel pellets in those fuel elements were removed from the original Incoloy cladding and reclad in 3003 aluminum tubes and end caps for use in the experiments reported here. The five critical experiments in this series were performed in August through December 2022, in the Sandia Critical Experiments (SCX) at the Sandia Pulsed Reactor Facility. Case 1 had no molybdenum sleeves, Case 2 had 208 molybdenum sleeves clustered at the center of the array, Case 3 had 397 molybdenum sleeves clustered at the center of the array, Case 4 had 175 molybdenum sleeves in the central position and in five alternating hexagonal rings, and Case 5 had 331 molybdenum sleeves in the central position and in seven alternating hexagonal rings. All five critical experiments are judged to be acceptable as benchmark experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Titanium and Aluminum Rod-Replacement Experiments in Fully-Reflected 6.90% Enriched UO{sub 2} Fuel Rod Lattices

The Seven Percent Critical Experiment (7uPCX) was designed to provide benchmark criticality and reactor physics data for water-moderated pin-fueled nuclear reactor cores. The enrichment of the fuel was chosen to explore the enrichment range above the current 5% ceiling for US commercial pressurized water reactors. The experiment was part of the US Department of Energy (DOE) Nuclear Energy Research Initiative Project 01-124 titled 'Reactor Physics and Criticality Benchmark Evaluations for Advanced Nuclear Fuel'. Three sets of benchmark experiments have been completed using the 7uPCX and documented as LEUCOMP-THERM-080, LEU-COMP-THERM-078, and LEUCOMP-THERM-096. The experiments for LEUCOMP-THERM-080 and LEU-COMP-THERM-078 were done in fully-reflected arrays with the number of fuel rods in the array as the approach parameter. The experiments for LEU-COMP-THERM-096 are similar to those in LEUCOMP-THERM-080 except that the arrays are partially-reflected - the arrays were larger than would be possible with full reflection and the approach-to-critical experiments were done with the depth of the water in the critical assembly as the approach parameter. The experiments described here are similar to the fully-reflected experiments in LEU-COMP-THERM-080 with some of the central fuel rods in the array replaced by titanium rods, aluminum rods, and/or water. The experiments are designed to provide criticality safety benchmarks with significant reactivity from titanium and equivalent configurations with aluminum experiment rods. These experiments are documented as LEU-COMP-THERM-097. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RDX solubility in TNT at high temperatures

The solubility of RDX (hexahydro-1,3,5-tri-nitro-1,3,5-triazine) in TNT (2,4,6-trinitrotoluene) at elevated temperatures is required to accurately predict the response of Comp-B 3 (60:40 RDX:TNT) during accidents involving fire. As the temperature increases, the TNT component melts, the RDX partially dissolves in the liquid TNT, and the remaining RDX melts (203 °C) as the Comp-B thermally ignites. In the current work, we used a differential scanning calorimeter (DSC) to estimate the solubility of RDX in TNT at the melting point of RDX. Most DSC measurements of Comp-B 3 do not show an RDX melt endotherm. The absence of an endotherm associated with the RDX melt has been interpreted as RDX being completely dissolved in TNT before reaching the melting point. Here, we have observed that the endotherm is not absent, but is masked by exothermic reactions occurring at these elevated temperatures. We have inhibited the exothermic reactions by venting our DSC samples and measuring the RDX melt endotherm in our Comp-B 3 samples at about 203 °C. Using the measured heat flow associated with the RDX melt and the latent melting enthalpy of RDX, we have approximated the solubility of RDX in TNT to be roughly 50–100 g RDX per 100 g TNT . The broad range is based on corrections for exothermic reactions occurring as the RDX melts.

42 ENGINEERING↗

Programmable Synthesis of Multimetallic Phosphide Nanorods Mediated by Core/Shell Structure Formation and Conversion

Generalized synthetic strategies for nanostructures with well-defined physical dimensions and broad-range chemical compositions are at the frontier of advanced nanomaterials design, functionalization, and application. In this paper, we report a composition-programmable synthesis of multimetallic phosphide CoMP x nanorods (NRs) wherein M can be controlled to be Fe, Ni, Mn, Cu, and their binary combinations. Forming Co 2 P/MP x core/shell NRs and subsequently converting them into CoMP x solid-solution NRs through thermal post-treatment are essential to overcome the obstacle of morphology/structure inconsistency faced in conventional synthesis of CoMP x with the different M compositions. The resultant CoMP x with uniform one-dimensional (1-D) structure provides us a platform to unambiguously screen the M synergistic effects in improving the electrocatalytic activity, as exemplified by the oxygen evolution reaction. This new approach mediated by core/shell nanostructure formation and conversion can be extended to other multicomponent nanocrystal systems (metal alloy, mixed oxide, and chalcogenide, etc.) for diverse applications.

36 MATERIALS SCIENCE↗

ESTIMATING THE ''DARK'' ENERGY CONTENT OF THE SOLAR CORONA

The discovery of ubiquitous low-frequency (3-5 mHz) Alfvenic waves in the solar chromosphere (with Hinode/Solar Optical Telescope) and corona (with CoMP and SDO) has provided some insight into the non-thermal energy content of the outer solar atmosphere. However, many questions remain about the true magnitude of the energy flux carried by these waves. Here we explore the apparent discrepancy in the resolved coronal Alfvenic wave amplitude ({approx}0.5 km s{sup -1}) measured by the Coronal Multi-channel Polarimeter (CoMP) compared to those of the Hinode and the Solar Dynamics Observatory (SDO) near the limb ({approx}20 km s{sup -1}). We use a blend of observational data and a simple forward model of Alfvenic wave propagation to resolve this discrepancy and determine the Alfvenic wave energy content of the corona. Our results indicate that enormous line-of-sight superposition within the coarse spatio-temporal sampling of CoMP hides the strong wave flux observed by Hinode and SDO and leads to the large non-thermal line broadening observed. While this scenario has been assumed in the past, our observations with CoMP of a strong correlation between the non-thermal line broadening with the low-amplitude, low-frequency Alfvenic waves observed in the corona provide the first direct evidence of a wave-related non-thermal line broadening. By reconciling the diverse measurements of Alfvenic waves, we establish large coronal non-thermal line widths as direct signatures of the hidden, or ''dark'', energy content in the corona and provide preliminary constraints on the energy content of the wave motions observed.

79 ASTRONOMY AND ASTROPHYSICS↗

Pitch Variation Experiments in Water-Moderated Square-Pitched U(6.90)O 2 Fuel Rod Lattices with Fuel to Water Volume Ratios Spanning 0.08 to 0.67

The US Department of Energy (DOE) Nuclear Energy Research Initiative funded the design and construction of the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories. The start-up of the experiment facility and the execution of the experiments described here were funded by the DOE Nuclear Criticality Safety Program. The 7uPCX is designed to investigate critical systems with fuel for light water reactors in the enrichment range above 5 % 235 U. The 7uPCX assembly is a water-moderated and -reflected array of aluminum-clad square-pitched U(6.90 %)O 2 fuel rods. Other critical experiments performed in the 7uPCX assembly are documented in LEU-COMP-THERM-078, LEU-COMP-THERM-080, LEU-COMPTHERM- 096, LEU-COMP-THERM-097, and LEU-COMP-THERM-101. The fuel used in these experiments was fabricated using unirradiated 6.90 % enriched UO 2 fuel pellets from fuel elements designed to be used in the internal nuclear superheater section of the Pathfinder boiling water reactor operated in South Dakota by the Northern States Power Company in the 1960s. The fuel elements were obtained from The Pennsylvania State University where they had been stored for many years. The fuel pellets in those fuel elements were removed from the original Incoloy cladding and reclad in 3003 aluminum tubes and end caps for use in the experiments reported here. The purpose of these experiments was to measure the effects of decreasing the fuel-to-water volume ratio on the critical array size. This was accomplished by removing fuel rods from fully fueled configurations, effectively increasing the pitch of the fuel arrays in the assembly. The fuel rod pitch variations provided assembly configurations that ranged from strongly undermoderated to slightly overmoderated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pitch Variation Experiments in Water-Moderated Square-Pitched U(6.9)O 2 Fuel Rod Lattices with Fuel to Water Volume Ratios Spanning 0.08 to 0.67

The US Department of Energy (DOE) Nuclear Energy Research Initiative funded the design and construction of the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories. The start-up of the experiment facility and the execution of the experiments described here were funded by the DOE Nuclear Criticality Safety Program. The 7uPCX is designed to investigate critical systems with fuel for light water reactors in the enrichment range above 5% 235 U. The 7uPCX assembly is a water-moderated and -reflected array of aluminum-clad square-pitched U(6.90%)O 2 fuel rods. Other critical experiments performed in the 7uPCX assembly are documented in LEU-COMP-THERM-078, LEU-COMP-THERM-080, LEU-COMPTHERM- 096, LEU-COMP-THERM-097, and LEU-COMP-THERM-101. The twenty-seven critical experiments in this series were performed in 2020 in the SCX at the Sandia Pulsed Reactor Facility. The experiments are grouped by fuel rod pitch. Case 1 is a base case with a pitch of 0.8001 cm and no water holes in the array. Cases 2 through 6 have the same pitch as Case 1 but contain various configurations with water holes, providing slight variations in the fuel-to-water ratio. Similarly, Case 7 is a base case with a pitch of 0.854964 cm and no water holes in the array. Cases 8 through 11 have the same pitch as Case 7 but contain various configurations with water holes. Cases 12 through 15 have a pitch of 1.131512 cm and differ according to the number of water holes in the array, with Case 12 having no water holes. Cases 16 through 19 have a pitch of 1.209102 cm and differ according to number of water holes in the array, with Case 16 having no water holes. Cases 20 through 23 have a pitch of 1.6002 cm and differ according to number of water holes in the array, with Case 20 having no water holes. Cases 24 through 27 have a pitch of 1.709928 cm and differ according to number of water holes in the array, with Case 24 having no water holes. As the experiment case number increases, the fuel-to-water volume ratio decreases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Partially-Reflected Water-Moderated Square-Pitched U(6.90)O 2 Fuel Rod Lattices with 0.52 Fuel to Water Volume Ratio (0.855 CM Pitch)

The US Department of Energy (DOE) Nuclear Energy Research Initiative funded the design and construction of the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories. The start-up of the experiment facility and the execution of the experiments described here were funded by the DOE Nuclear Criticality Safety Program. The 7uPCX is designed to investigate critical systems with fuel for light water reactors in the enrichment range above 5 % 235 U. The 7uPCX assembly is a water-moderated and -reflected array of aluminum-clad square-pitched U(6.90 %)0 2 fuel rods. Other critical experiments performed in the 7uPCX assembly are documented in LEU-COMP-THERM-078, LEU-COMP-THERM-080, LEU-COMP-THERM-096, and LEU-COMP-THERM-097.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of Model Uncertainties in Underground Chemical Explosions on Far-field Results

We used the CTH shock physics code to simulate the explosion of an 18-t chemical explosive at a depth of 250 m. We used the CTH in the two-dimensional axisymmetric (cylindrical) geometry (2DC) and most simulations included fully tamped explosions in wet tuff. Our study focused on parametric studies of three of the traditional strength models available in CTH, namely, geologic-yield, elastic perfectly-plastic von Mises, and Johnson-Cook strength (flow stress) models. We processed CTH results through a code that generates Reduced Displacement Potential (RDP) histories for each simulation. Since RDP is the solution of the linear wave equation in spherical coordinates, it is mainly valid at far-enough distance from the explosion the elastic radius. Among various parameters examined, we found the yield strength to have the greatest effect on the resulting RDP, where the peak RDP reduces almost linearly in log-log space as the yield strength increases. Moreover, an underground chemical explosion results in a cavity whose final diameter is inversely proportional to the material yield strength, i.e., as the material's yield strength increases the resulting final cavity radius decreases. Additionally, we found the choice of explosive material (COMP-C4 versus COMP-B) has minor effects on the peak RDP, where denser COMP-C4 shows higher peak RDP than the less dense COMP-B by a factor of ~1.1. In addition to wet tuff, we studied explosions in dry tuff, salt, and basalt, for a single strength model and yield strength value. We found wet tuff has the highest peak RDP value, followed by dry tuff, salt, and basalt. 2DC simulations of explosions in 11 m radius spherical, hemispherical, and cylindrical cavities showed the RDP signals have much lower magnitude than tamped explosions, where the cavity explosions mimicked nearly decoupled explosions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

DOES CRITICAL MASS DECREASE AS TEMPERATURE INCREASES: A REVIEW OF FIVE BENCHMARK EXPERIMENTS THAT SPAN A RANGE OF ELEVATED TEMPERATURES AND CRITICAL CONFIGURATIONS

Five sets of benchmark experiments are reviewed herein that cover a diverse set of fissile system configurations. The review specifically focused on the change in critical mass of these systems at elevated temperatures and the temperature reactivity coefficient ({alpha}{sub T}) on the system. Because plutonium-based critical benchmark experiments at varying temperatures were not found at the time this review was prepared, only uranium-based systems are included, as follows: (1) HEU-SOL-THERM-010 - UO{sub 2}F{sub 2} solutions with high U{sup 235} enrichment; (2) HEU-COMP-THERM-016 - uranium-graphite blocks with low U concentration; (3) LEU-COMP-THERM-032 - water moderated lattices of UO{sub 2} with stainless steel cladding, and intermediate U{sup 235} enrichment; (4) IEU-COMP-THERM-002 - water moderated lattices of annular UO{sub 2} with/without absorbers, and intermediate U{sup 235} enrichment; and (5) LEU-COMP-THERM-026 - water moderated lattices of UO{sub 2} at different pitches, and low U{sup 235} enrichment. In three of the five benchmarks (1, 3 and 5), modeling of the critical system at room temperature is conservative compared to modeling the system at elevated temperatures, i.e., a greater fissile mass is required at elevated temperature. In one benchmark (4), there was no difference in the fissile mass between the room temperature system and the system at the examined elevated temperature. In benchmark (2), the system clearly had a negative temperature reactivity coefficient. Some of the high temperature benchmark experiments were treated with appropriate (and comprehensive) adjustments to the cross section sets and thermal expansion coefficients, while other experiments were treated with partial adjustments. Regardless of the temperature treatment, modeling the systems at room temperature was found to be conservative for the examined systems, i.e., a smaller critical mass was obtained. While the five benchmarks presented herein demonstrate that, for the conditions examined, modeling of the systems at room temperature is conservative as compared to modeling the systems at elevated temperatures, it is possible to design a system in which the critical mass at room temperature is non-conservative compared to a system at elevated temperatures. As the temperature of the systems evaluated in this review was increased, the system's overall {alpha}{sub T} was negative at elevated temperatures. Furthermore, the review demonstrates that to accurate asses the effect of increased temperature on a system's k{sub eff}, changes in fissile, moderator, cladding, and, in some cases, structural material cross sections must be combined with other factors that influence reactivity, such as volumetric thermal expansion of fissile, moderating, reflector, and other interacting media. Altering the microscopic cross sections of fissile and moderating regions for temperature changes, without adjusting the corresponding densities at elevated temperatures can lead to an incorrect assessment of the impact of elevated temperature on a fissile system.

36 MATERIALS SCIENCE↗

Results of Partially-Reflected Critical Experiments in Square-Pitched Arrays of Water-Moderated 6.9 Percent Enriched Fuel Rods

The Seven Percent Critical Experiment (7uPCX) was designed to provide benchmark criticality and reactor physics data for water-moderated pin-fueled nuclear reactor cores. The enrichment of the fuel was chosen to explore the enrichment range above the current 5% ceiling for US commercial pressurized water reactors. The experiment was part of the US Department of Energy (DOE) Nuclear Energy Research Initiative (NERI) Project 01-124 titled “Reactor Physics and Criticality Benchmark Evaluations for Advanced Nuclear Fuel”. The NERI project was a collaboration between AREVA Federal Services, LLC; the University of Florida; Oak Ridge National Laboratory; and Sandia National Laboratories (SNL). The experiments at Sandia are currently supported by the DOE National Nuclear Security Administration Nuclear Criticality Safety Program. Two sets of benchmark experiments have been completed and documented as LEU-COMP-THERM-080 and LEU-COMP-THERM-078. Those experiments were done with the number of fuel rods in the fully-reflected array as the approach parameter. The experiments reported here are similar to those in LEU-COMP-THERM-080 except that the arrays are partially-reflected – the arrays were larger than would be possible with full reflection and the approach-to-critical experiments were done with the depth of the water in the critical assembly as the approach parameter. These experiments are reported as LEU-COMP-THERM-096.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A study of laser induced ignition of methane–air mixtures inside a Rapid Compression Machine

We present herein a fundamental study of laser ignition of methane/air mixtures at temperatures and pressures representative of an internal combustion engine. An Nd:YAG laser operating at λ = 1064 nm was used to ignite methane/air mixtures at equivalence ratios of 0.4 ≤ Φ ≤ 1 in a Rapid Compression Machine (RCM). Experiments were conducted to study the lean limit, minimum spark energy (MSE), and minimum ignition energy (MIE). The results show that laser ignition exhibits a stochastic behavior which must be interpreted statistically. A 90% probability of occurrence was used to evaluate the MSE and MIE, which resulted in MSE 90 =2.3 mJ and MIE 90 =7.2 mJ at an equivalence ratio Φ = 0.4 at compressed pressure and temperature of P comp = 29 bar and T comp = 750 K, respectively. The lean limit was characterized based on the fraction of chemical energy converted into thermal energy, which was determined by calculating the apparent rate of heat release as derived from RCM high speed pressure data. A lean limit for 90% chemical energy conversion was found to correspond to an equivalence ratio of 0.47 (T comp = 782 K). Schlieren photography was employed as a diagnostics tool to visualize the flame initiation and propagation inside the RCM.

42 ENGINEERING↗

Integrated rheology model: Explosive Composition B-3

Composition B-3 (Comp B-3) is a high explosive formulation composed of 60/40wt% RDX (1,3,5-trinitroperhydro-1,3,5-triazine) /TNT (2,4,6 trinitrotoluene). Above approximately 78°C this formulation partially melts to form a multiphase system with solid RDX particles in a molten TNT matrix. This multiphase system presents a number of phenomena that influence its apparent viscosity. In an earlier study explosive Composition B-3 (Comp B-3, 60/40wt% RDX/TNT) was examined for evidence of yield stress using a non-isothermal falling ball viscometer and a yield stress model was proposed in this paper. An integrated viscosity model suitable for use in computational fluid dynamics (CFD) simulations is developed to capture the transition from a heterogeneous solid to a Bingham viscoplastic fluid. This viscosity model is used to simulate the motion of imbedded spheres falling through molten Comp B-3. Finally, comparison of the simulations to physical tests show agreement between the positions predicted by the model and the measured locations of the spheres as a function of temperature between 90C and 165C.

36 MATERIALS SCIENCE↗

THE OPTX PROJECT. V. IDENTIFYING DISTANT ACTIVE GALACTIC NUCLEI

The Baldwin, Phillips, and Terlevich emission-line ratio diagnostic ([O III]/H{beta} versus [N II]/H{alpha}, hereafter BPT diagram) efficiently separates galaxies whose signal is dominated by star formation (BPT-SF) from those dominated by active galactic nucleus (AGN) activity (BPT-AGN). Yet this BPT diagram is limited to z < 0.5, the redshift at which [N II]{lambda}6584 leaves the optical spectral window. Using the Sloan Digital Sky Survey (SDSS), we construct a new diagnostic, or TBT diagram, that is based on rest-frame g - z color, [Ne III]{lambda}3869, and [O II]{lambda}{lambda}3726 + 3729 and can be used for galaxies out to z < 1.4. The TBT diagram identifies 98.7% of the SDSS BPT-AGN as TBT-AGN and 97% of the SDSS BPT-SF as TBT-SF. Furthermore, it identifies 97% of the OPTX Chandra X-ray-selected AGNs as TBT-AGN. This is in contrast to the BPT diagram, which misidentifies 20% of X-ray-selected AGNs as BPT-SF. We use the Great Observatories Origins Deep Survey North and Lockman Hole galaxy samples, with their accompanying deep Chandra imaging, to perform X-ray and infrared stacking analyses to further validate our TBT-AGN and TBT-SF selections; that is, we verify the dominance of AGN activity in the former and star formation activity in the latter. Finally, we address the inclusion of the majority of the BPT-comp (sources lying between the BPT-SF and BPT-AGN regimes) in our TBT-AGN regime. We find that the stacked BPT-comp source is X-ray hard (({Gamma}{sub eff}) = 1.0{sup +0.4}{sub -0.4}) and has a high X-ray luminosity to total infrared luminosity ratio. This suggests that, on average, the X-ray signal in BPT-comp is dominated by obscured or low accretion rate AGN activity rather than by star formation, supporting their inclusion in the TBT-AGN regime.

79 ASTRONOMY AND ASTROPHYSICS↗

A RING OF POLARIZED LIGHT: EVIDENCE FOR TWISTED CORONAL MAGNETISM IN CAVITIES

Coronal prominence cavities may be manifestations of twisted or sheared magnetic fields capable of storing the energy required to drive solar eruptions. The Coronal Multi-Channel Polarimeter (CoMP), recently installed at Mauna Loa Solar Observatory, can measure polarimetric signatures of current-carrying magnetohydrodynamic (MHD) systems. For the first time, this instrument offers the capability of daily full-Sun observations of the forbidden lines of Fe XIII with high enough spatial resolution and throughput to measure polarimetric signatures of current-carrying MHD systems. By forward-calculating CoMP observables from analytic MHD models of spheromak-type magnetic flux ropes, we show that a predicted observable for such flux ropes oriented along the line of sight is a bright ring of linear polarization surrounding a region where the linear polarization strength is relatively depleted. We present CoMP observations of a coronal cavity possessing such a polarization ring.

79 ASTRONOMY AND ASTROPHYSICS↗

Influence of diurnal variation in mesophyll conductance on modelled 13 C discrimination: results from a field study

Mesophyll conductance to CO 2 (g m ) limits carbon assimilation and influences carbon isotope discrimination (Δ) under most environmental conditions. Current work is elucidating the environmental regulation of gm, but the influence of g m on model predictions of Δ remains poorly understood. In this study, field measurements of Δ and g m were obtained using a tunable diode laser spectroscope coupled to portable photosynthesis systems. These data were used to test the importance of g m in predicting Δ using the comprehensive Farquhar model of Δ (Δ comp ), where g m was parameterized using three methods based on: (i) mean g m ; (ii) the relationship between stomatal conductance (g s ) and g m ; and (iii) the relationship between time of day (TOD) and g m . Incorporating mean g m , g s -based g m , and TOD-based g m did not consistently improve Δ comp predictions of field-grown juniper compared with the simple model of D (Δ simple ) that omits fractionation factors associated with g m and decarboxylation. Sensitivity tests suggest that b, the fractionation due to carboxylation, was lower (25‰) than the value commonly used in Δ comp (29‰) and Δ simple (27‰). These results demonstrate the limits of all tested models in predicting observed juniper Δ, largely due to unexplained offsets between predicted and observed values that were not reconciled in sensitivity tests of variability in g m , b, or e, the day respiratory fractionation.

54 ENVIRONMENTAL SCIENCES↗

Comparison of organ-at-risk sparing and plan robustness for spot-scanning proton therapy and volumetric modulated arc photon therapy in head-and-neck cancer

Purpose: Proton radiotherapy for head-and-neck cancer (HNC) aims to improve organ-at-risk (OAR) sparing over photon radiotherapy. However, it may be less robust for setup and range uncertainties. The authors investigated OAR sparing and plan robustness for spot-scanning proton planning techniques and compared these with volumetric modulated arc therapy (VMAT) photon plans. Methods: Ten HNC patients were replanned using two arc VMAT (RapidArc) and spot-scanning proton techniques. OARs to be spared included the contra- and ipsilateral parotid and submandibular glands and individual swallowing muscles. Proton plans were made using Multifield Optimization (MFO, using three, five, and seven fields) and Single-field Optimization (SFO, using three fields). OAR sparing was evaluated using mean dose to composite salivary glands (Comp{sub Sal}) and composite swallowing muscles (Comp{sub Swal}). Plan robustness was determined for setup and range uncertainties (±3 mm for setup, ±3% HU) evaluating V95% and V107% for clinical target volumes. Results: Averaged over all patients Comp{sub Sal}/Comp{sub Swal} mean doses were lower for the three-field MFO plans (14.6/16.4 Gy) compared to the three-field SFO plans (20.0/23.7 Gy) and VMAT plans (23.0/25.3 Gy). Using more than three fields resulted in differences in OAR sparing of less than 1.5 Gy between plans. SFO plans were significantly more robust than MFO plans. VMAT plans were the most robust. Conclusions: MFO plans had improved OAR sparing but were less robust than SFO and VMAT plans, while SFO plans were more robust than MFO plans but resulted in less OAR sparing. Robustness of the MFO plans did not increase with more fields.

60 APPLIED LIFE SCIENCES↗

Use Case Specification

Over the past three years, the Use Case Specification project has provided scenarios that have driven the development of key E-COMP capabilities and demonstrated their application to problems that the electric power industry is facing. These scenarios have provided the basis for which each Thrust has performed technical work, tying together E-COMP work under a common umbrella. Documented in this report is a summary of the background, motivations, and work – completed or proposed – under the three E-COMP use cases pursued to date: Offshore Wind, Remote Communities on the Olympic Peninsula, and Large Electric Loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗