Use of Commercial Electrical, Electronic and Electromechanical (EEE) Parts in NASA's Commercial Crew Program (CCP)

NASA's Commercial Crew and Cargo Program (CCP) is stimulating efforts within the private sector to develop and demonstrate safe, reliable, and cost-effective space transportation capabilities. One initiative involves investigating the use of commercial electronic parts. NASA's CCP asked the NASA Engineering and Safety Center (NESC) to collect data to help frame the technical, cost, and schedule risk trades associated with electrical, electronic and electromechanical (EEE) parts selection and specifically expressed desire of some of the CCP partners to employ EEE parts of a lower grade than traditionally used in most NASA safety-critical applications. This document contains the outcome from the NESC's review and analyses.

Gonzalex, Oscar↗

ESO Commercial Microgravity Case Study 1: Novice Commercial Users (Medical) Vivo Biosciences Inc. - A Small Business Perspective

This case study was conducted in FY 2013 by the Emerging Space Office (ESO) to begin characterizing the kinds of opportunities and challenges encountered by small high-tech businesses who have never done RD in space and who serve terrestrial versus space markets, but who have legitimate business reasons for considering space research and development for generating novel or improved products. Vivo Biosciences Inc. (VBI) is an award winning company with a customer base that includes major pharmaceutical companies. However, despite a continuing series of successes, VBI believes that they are about at the limit of the performance their product can achieve on Earth and gravity is the problem. This Case Study documented VBI's experience as the novice company attempted its first steps in the process of conducting research and development in space. The report presents insights applicable to commercial suppliers of microgravity services as well as ISS support of new commercial users, especially small businesses interested in using space for product development.

Harper, Lynn D.↗

Evaluation of a commercially available passively Q-switched Nd:YAG laser with LiF:F-2(-) saturable absorber for laser-induced breakdown spectroscopy

Interest in passively Q-switched microchip lasers as a means for miniaturization of laser-induced breakdown spectroscopy (LIBS) apparatus has rapidly grown in the last years. To explore the possibility of using a comparatively UV-Vis transparent absorber, we herein present the first report on the evaluation of a commercially available flash lamp-pumped passively Q-switched Nd:YAG laser with LiF:F 2 - saturable absorber as an excitation source in LIBS. Quantitative measurements of barium, strontium, rubidium and lithium in granite, rhyolite, basalt and syenite whole-rock glass samples were performed. Ablation craters produced on a rock glass sample were characterized using a computerized X-ray tomography. Using a gated intensified benchtop spectrometer, limits of detection of 0.97, 23, 37, and 144 ppm were obtained for Li, Sr, Rb, and Ba, respectively. Finally, we discuss the advantages of using such a laser unit for LIBS applications in terms of ablation efficiency, analytical performances, output energy, and standoff capabilities.

36 MATERIALS SCIENCE↗

Absolute dosimetric characterization of Gafchromic EBT3 and HDv2 films using commercial flat-bed scanners and evaluation of the scanner response function variability

Radiochromic films (RCF) are commonly used in dosimetry for a wide range of radiation sources (electrons, protons, and photons) for medical, industrial, and scientific applications. They are multi-layered, which includes plastic substrate layers and sensitive layers that incorporate a radiation-sensitive dye. Quantitative dose can be retrieved by digitizing the film, provided that a prior calibration exists. Here, to calibrate the newly developed EBT3 and HDv2 RCFs from Gafchromic™, we used the Stanford Medical LINAC to deposit in the films various doses of 10 MeV photons, and by scanning the films using three independent EPSON Precision 2450 scanners, three independent EPSON V750 scanners, and two independent EPSON 11000XL scanners. The films were scanned in separate RGB channels, as well as in black and white, and film orientation was varied. We found that the green channel of the RGB scan and the grayscale channel are in fact quite consistent over the different models of the scanner, although this comes at the cost of a reduction in sensitivity (by a factor ∼2.5 compared to the red channel). To allow any user to extend the absolute calibration reported here to any other scanner, we furthermore provide a calibration curve of the EPSON 2450 scanner based on absolutely calibrated, commercially available, optical density filters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Database for Comparative Electrochemical Performance of Commercial 18650-Format Lithium-Ion Cells

Lithium-ion batteries are a central technology to our daily lives with widespread use in mobile devices and electric vehicles. These batteries are also beginning to be widely used in electric grid infrastructure support applications which have stringent safety and reliability requirements. Typically, electrochemical performance data is not available for modelers to validate their simulations, mechanisms, and algorithms for lithium-ion battery performance and lifetime. In this paper, we report on the electrochemical performance of commercial 18650 cells at a variety of temperatures and discharge currents. We found that LiFePO 4 is temperature tolerant for discharge currents at or below 10 A whereas LiCoO 2 , LiNi x Co y Al 1-x-y O 2 , and LiNi 0.80 Mn 0.15 Co 0.05 O 2 exhibited optimal electrochemical performance when the temperature is maintained at 15°C. LiNi x Co y Al 1-x-y O 2 showed signs of lithium plating at lower temperatures, evidenced by irreversible capacity loss and emergence of a high-voltage differential capacity peak. Furthermore, all cells need to be monitored for self-heating, as environment temperature and high discharge currents may elicit an unintended abuse condition. Overall, this study shows that lithium-ion batteries are highly application-specific and electrochemical behavior must be well understood for safe and reliable operation. Additionally, data collected in this study is available for anyone to download for further analysis and model validation.

25 ENERGY STORAGE↗

Li‐ and Mn‐Rich Cathode Materials: Challenges to Commercialization

The lithium‐ and manganese‐rich (LMR) layered structure cathodes exhibit one of the highest specific energies (≈900 W h kg −1 ) among all the cathode materials. However, the practical applications of LMR cathodes are still hindered by several significant challenges, including voltage fade, large initial capacity loss, poor rate capability and limited cycle life. Herein, we review the recent progress and in depth understandings on the application of LMR cathode materials from a practical point of view. Several key parameters of LMR cathodes that affect the LMR/graphite full‐cell operation are systematically analyzed. These factors include the first‐cycle capacity loss, voltage fade, powder tap density, and electrode density. New approaches to minimize the detrimental effects of these factors are highlighted in this work. We also provide perspectives for the future research on LMR cathode materials, focusing on addressing the fundamental problems of LMR cathodes while keeping practical considerations in mind.

Zheng, Jianming↗

Microstructural characterization of cold-worked 316 stainless steel flux thimble tubes irradiated up to 100 dpa in a commercial Pressurized Water Reactor

Two flux thimble tubes (FTT) made of 15% cold-worked 316 stainless steel (SS) were harvested from Ringhals Pressurized Water Reactor (PWR) Unit 2, with peak damages of 76 and 100 displacements per atom (dpa) after 29 and 34 years’ service, respectively. Specimens sectioned from parent tubes were comprehensively characterized with nominal damage levels of ~0, ~41, ~74, 76, and 100 dpa at a nominal temperature range of 285-323 °C. Both FTTs contained helium and hydrogen gases as transmutation products. The helium follows a production rate of ~9.8 appm/dpa, while environmental factors complicate hydrogen production obscuring an exact H/dpa ratio. Irradiation-induced dislocation loops, nano-cavities, solute clusters, and microsegregation were all observed. The dislocation loops and nano-cavities indicated saturation at 41 dpa. The solute clusters continued to evolve with Ni-Si clusters formed at 41 dpa, and Ni-Si-Mn-P clusters formed at 74 and 100 dpa, but neither clusters exhibited distinct diffraction patterns at any damage levels. Solute clusters were observed to frequently be co-located with dislocation loops, but fully decorated loops were rarely detected. Significant radiation-induced segregation (RIS) was observed around grain boundaries at all damage levels. The modified inverse Kirkendall (MIK) model captured the RIS behavior of major elements. Large cavities within or around an Mn-S rich region were observed for the first time. Through all the damage levels, void swelling is always below 0.05%, making significant dimensional change unlikely in core internals when used at similar conditions. Meanwhile, the role of overwhelming nanocavities, presumably helium bubbles, should be considered in other potential degradation mechanisms, including irradiation-assisted stress corrosion cracking, embrittlement, and loss of fracture toughness, which remain the concerns for extended operation of nuclear power plants.

Post Irradiation Examination, Isotope Dilution Mas↗