Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHROMIUM 50”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Comparison of Four Strong Acids on the Precipitation Potential of Gypsum in Brines During Distillation of Pretreated, Augmented Urine

In this study, three different mineral acids were substituted for sulfuric acid (H2SO4) in the urine stabilizer solution to eliminate the excess of sulfate ions in pretreated urine and assess the impact on maximum water recovery to avoid precipitation of minerals during distillation. The study evaluated replacing 98% sulfuric acid with 85% phosphoric acid (H3PO4), 37% hydrochloric acid (HCl), or 70% nitric acid (HNO3). The effect of lowering the oxidizer concentration in the pretreatment formulation also was studied. This paper summarizes the test results, defines candidate formulations for further study, and specifies the injection masses required to stabilize urine and minimize the risk of mineral precipitation during distillation. In the first test with a brine ersatz acidified with different acids, the solubility of calcium in gypsum saturated solutions was measured. The solubility of gypsum was doubled in the brines acidified with the alternative acids compared to sulfuric acid. In a second series of tests, the alternative acid pretreatment concentrations were effective at preventing precipitation of gypsum and other minerals up to 85% water recovery from 95th-percentile pretreated, augmented urine. Based on test results, phosphoric acid is recommended as the safest alternative to sulfuric acid. It also is recommended that the injected mass concentration of chromium trioxide solution be reduced by 75% to minimize liquid resupply mass by about 50%, reduce toxicity of brines, and reduce the concentration of organic acids in distillate. The new stabilizer solution formulations and required doses to stabilize urine and prevent precipitation of minerals up to 85% water recovery are given. The formulations in this study were tested on a limited number of artificially augmented urine batches collected from employees at the Johnson Space Center (JSC). This study successfully demonstrated that the desired physical and chemical stability of pretreated urine and brines can be achieved using alternate pretreatment formulations under laboratory conditions. Additional testing and hazard assessments will be required to determine the feasibility of utilizing the proposed urine pretreatment formulations on ISS.

Muirhead, Dean↗

A fetal whole ovarian culture model for the evaluation of CrVI-induced developmental toxicity during germ cell nest breakdown

Prenatal exposure to endocrine disrupting chemicals (EDCs), including bisphenol A, dioxin, pesticides, and cigarette smoke, has been linked to several ovarian diseases such as premature ovarian failure (POF) and early menopause in women. Hexavalent chromium (CrVI), one of the more toxic heavy metals, is widely used in more than 50 industries. As one of the world's leading producers of Cr compounds, the U.S. is facing growing challenges in protecting human health against adverse effects of CrVI. Our recent findings demonstrated that in vivo CrVI exposure during gestational period caused POF in F1 offspring. Our current research focus is three-fold: (i) to identify the effect of CrVI on critical windows of great vulnerability of fetal ovarian development; (ii) to understand the molecular mechanism of CrVI-induced POF; (iii) to identify potential intervention strategies to mitigate or inhibit CrVI effects. In order to accomplish these goals we used a fetal whole ovarian culture system. Fetuses were removed from the normal pregnant rats on gestational day 13.5. Fetal ovaries were cultured in vitro for 12 days, and treated with or without 0.1 ppm potassium dichromate (CrVI) from culture day 2–8, which recapitulated embryonic day 14.5–20.5, in vivo. Results showed that CrVI increased germ cell/oocyte apoptosis by increasing caspase 3, BAX, p53 and PUMA; decreasing BCL2, BMP15, GDF9 and cKIT; and altering cell cycle regulatory genes and proteins. This model system may serve as a potential tool for high throughput testing of various drugs and/or EDCs in particular to assess developmental toxicity of the ovary. - Highlights: • CrVI (0.1 ppm, a regulatory dose) increased germ cell apoptosis of fetal ovaries. • CrVI (0.1 ppm) increased pro-apoptotic proteins. • CrVI (0.1 ppm) decreased cyclins and CDK1 and cell survival proteins. • CrVI (0.1 ppm) increased oxidative stress during fetal ovarian development. • We propose fetal ovarian culture model for high-throughput testing of heavy-metals.

60 APPLIED LIFE SCIENCES↗

Infrared absorptivities of transition metals at room and liquid-helium temperatures.

Evaluation of experimental data concerning the normal spectral absorptivities of the transition metals, nickel, iron, platinum, and chromium, at both room and liquid-helium temperatures in the wavelength range from 2.5 to 50 microns. The absorptivities were derived from reflectivity measurements made relative to a room-temperature vapor-deposited gold reference mirror. The absorptivity of the gold reference mirror was measured calorimetrically, by use of infrared laser sources. Investigation of various methods of sample-surface preparation resulted in the choice of a vacuum-annealing process as the final stage. The experimental results are discussed on the basis of the anomalous-skin-effect theory modified for multiple conduction bands. As predicted, the results approach a single-band model toward the longer wavelengths. Agreement between theory and experiment is considerably improved by taking into account the modification of the relaxation time due to the photon-electron-phonon interaction proposed by Holstein (1954) and Gurzhi (1958); but, particularly at helium temperatures, the calculated curve is consistently below the experimental results.

Jones, M. C.↗

Distance-dependent plasma composition and ion energy in high power impulse magnetron sputtering

The plasma composition of high power impulse magnetron sputtering (HIPIMS) has been studied for titanium and chromium targets using a combined energy analyser and quadrupole mass spectrometer. Measurements were done at distances from 50 to 300 mm from the sputtering target. Ti and Cr are similar in atomic mass but have significantly different sputter yields, which gives interesting clues on the effect of the target on plasma generation and transport of atoms. The Ti and Cr HIPIMS plasmas operated at a peak target current density of ~;;0.5 A cm-2. The measurements of the argon and metal ion content as well as the ion energy distribution functions showed that (1) singly and doubly charged ions were found for argon as well as for the target metal, (2) the majority of ions were singly charged argon for both metals at all distances investigated, (3) the Cr ion density was maintained to distances further from the target than Ti. Gas rarefaction was identified as a main factor promoting transport of metal ions, with the stronger effect observed for Cr, the material with higher sputter yield. Cr ions were found to displace a significant portion of the gas ions, whereas this was less evident in the Ti case. The observations indicate that the presence of metal vapour promotes charge exchange and reduces the electron temperature and thereby practically prevents the production of Ar2+ ions near the target. The content of higher charge states of metal ions depends on the probability of charge exchange with argon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dislocation loop evolution during in-situ ion irradiation of model FeCrAl alloys

Model FeCrAl alloys of Fe-10%Cr-5%Al, Fe-12%Cr-4.5%Al, Fe-15%Cr-4%Al, and Fe-18%Cr-3%Al (in wt %) were irradiated with 1 MeV Kr++ ions in-situ with transmission electron microscopy to a dose of 2.5 displacements per atom (dpa) at 320 °C. In all cases, the microstructural damage consisted of dislocation loops with ½< 111 > and <100 > Burgers vectors. The proportion of ½< 111 > dislocation loops varied from ~50% in the Fe-10%Cr-5%Al model alloy and the Fe-18Cr%-3%Al model alloy to a peak of ~80% in the model Fe-15%Cr-4.5%Al alloy. The dislocation loop volume density increased with dose for all alloys and showed signs of approaching an upper limit. The total loop populations at 2.5 dpa had a slight (and possibly insignificant) decline as the chromium content was increased from 10 to 15 wt %, but the Fe-18%Cr-3%Al alloy had a dislocation loop population ~50% smaller than the other model alloys. As a result, the largest dislocation loops in each alloy had image sizes of close to 20 nm in the micrographs, and the median diameters for all alloys ranged from 6 to 8 nm. Nature analysis by the inside-outside method indicated most dislocation loops were interstitial type.

36 MATERIALS SCIENCE↗

Mach 1 oxidation of thoriated nickel chromium at 1204 C (2200 F)

TD NiCr was exposed to a Mach 1, 1-atmosphere gas stream at 1204 C for times up to 50 hours. Weight change, metal thickness loss, X-ray diffraction, metallographic, and electron microprobe analyses were made. Neither surface preparation nor thermal cycling had an appreciable effect on the results. Initially, Cr2O3 formed and volatilized, allowing a rapid metal loss rate of 40 microns per hour. After about 1 hour the Cr2O3 broke down, resulting in an NiO overgrowth. The metal loss rate then slowed to 2.5 microns per hour and remained constant to 50 hours.

Lowell, C. E.↗

All possible ternary fragmentations of {sup 252}Cf in collinear configuration

All possible ternary fragmentations in fission of {sup 252}Cf are studied in collinear configuration within a spherical approximation using the recently proposed ''three cluster model.'' The potential energy surface of collinear configuration exhibits a strong valley around {sup 48}Ca and its neighboring nuclei {sup 50}Ca, {sup 54}Ti, and {sup 60}Cr. Such strong minima are not seen in the potential energy surface of an equatorial configuration. As a consequence of strong minima in the potential, the overall relative yield is higher for the ternary fragmentation with {sup 48}Ca, {sup 50}Ca, {sup 54}Ti, {sup 60}Cr, and {sup 82}Ge as the third fragment. The results of potential energy and relative yield calculations reveal that collinear configuration increases the probability of emission of heavy fragments like {sup 48}Ca (doubly magic nucleus) and its neighboring nuclei as the third fragment. The obtained results indicate that the collinear configuration is the preferred configuration for intermediate nuclei ({sup 48}Ca, {sup 50}Ca, {sup 54}Ti, and {sup 60}Cr) as the third fragment in particle accompanied fission while the equatorial configuration may be a preferred configuration for light nuclei ({sup 4}He, {sup 10}Be) as the third fragment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect Of Oxidation On Chromium Leaching And Redox Capacity Of Slag-Containing Waste Forms

The rate of oxidation is important to the long-term performance of reducing salt waste forms because the solubility of some contaminants, e.g., technetium, is a function of oxidation state. TcO 4 - in the salt solution is reduced to Tc(IV) and has been shown to react with ingredients in the waste form to precipitate low solubility sulfide and/or oxide phases [Shuh, et al., 1994, Shuh, et al., 2000, Shuh, et al., 2003]. Upon exposure to oxygen, the compounds containing Tc(IV) oxidize to the pertechnetate ion, Tc(VII)O 4 - , which is very soluble. Consequently the rate of technetium oxidation front advancement into a monolith and the technetium leaching profile as a function of depth from an exposed surface are important to waste form performance and ground water concentration predictions. An approach for measuring contaminant oxidation rate (effective contaminant specific oxidation rate) based on leaching of select contaminants of concern is described in this report. In addition, the relationship between reduction capacity and contaminant oxidation is addressed. Chromate was used as a non-radioactive surrogate for pertechnetate in simulated waste form samples. Depth discrete subsamples were cut from material exposed to Savannah River Site (SRS) field cured conditions. The subsamples were prepared and analyzed for both reduction capacity and chromium leachability. Results from field-cured samples indicate that the depth at which leachable chromium was detected advanced further into the sample exposed for 302 days compared to the sample exposed to air for 118 days (at least 50 mm compared to at least 20 mm). Data for only two exposure time intervals is currently available. Data for additional exposure times are required to develop an equation for the oxidation front progression. Reduction capacity measurements (per the Angus-Glasser method, which is a measurement of the ability of a material to chemically reduce Ce(IV) to Ce(III) in solution) performed on depth discrete samples could not be correlated with the amount of chromium leached from the depth discrete subsamples or with the oxidation front inferred from soluble chromium (i.e., effective Cr oxidation front). Exposure to oxygen (air or oxygen dissolved in water) results in the release of chromium through oxidation of Cr(III) to highly soluble chromate, Cr(VI). Residual reduction capacity in the oxidized region of the test samples indicates that the remaining reduction capacity is not effective in re-reducing Cr(VI) in the presence of oxygen. Consequently, this method for determining reduction capacity may not be a good indicator of the effective contaminant oxidation rate in a relatively porous solid (40 to 60 volume percent porosity). The chromium extracted in depth discrete samples ranged from a maximum of about 5.8 % at about 5 mm (118 day exposure) to about 4 % at about 10 mm (302 day exposure). The use of reduction capacity as an indicator of long-term performance requires further investigation. The carbonation front was also estimated to have advanced to at least 28 mm in 302 days based on visual observation of gas evolution during acid addition during the reduction capacity measurements. Depth discrete sampling of materials exposed to realistic conditions in combination with short term leaching of crushed samples has potential for advancing the understanding of factors influencing performance and will support conceptual model development.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The T{sub z} = -1{yields}T{sub z} =0 beta decays and comparison with Charge Exchange reactions

Gamow-Teller (GT) transitions can be studied in both {beta} decay and charge exchange (CE) reactions. If isospin is a good quantum number, then the Tz = -1{yields}0 and Tz = +1{yields}0GT mirror transitions, are identical. Therefore, a comparison of the results from studies of {beta} decay and CE should shed light on this assumption. Accordingly we have studied the {beta} decay of the Tz = -1 fp-shell nuclei, {sup 54}Ni, {sup 50}Fe, {sup 46}Cr, and {sup 42}Ti, produced in fragmentation and we have compared our results with the spectra from ({sup 3}He, t) measurements on the mirror Tz = +1 target nuclei studied in high resolution at RCNP, Osaka. The {beta} decay experiments were performed as part of the STOPPED beam RISING campaign at GSI.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monitoring Hexavalent Chromium in the Columbia River Hypo-rheic Zone - 16405

Concentrations of hexavalent chromium in groundwater at the 100-BC reactor area, located on the U.S. Department of Energy's Hanford Site, exceed the State of Washington's surface water quality criterion of 10 μg/L. Groundwater discharge to the Columbia River is the primary pathway for contaminants to reach potential receptors. Additional monitoring was needed in order to make an informed decision about groundwater remediation. An array of 23 hypo-rheic sampling points (HSPs) was installed and monitored. The HSPs consist of stainless-steel tubing with 15-cm long mesh screens at depths ranging from 0.15 to 1 meter in the riverbed. The HSPs, which are fully submerged at all river stages, were installed and sampled from a boat using low-flow pumping. The HSPs provided permanent sampling points to obtain samples of hypo-rheic zone water. They were equally suitable for high-frequency sampling, with up to 48 samples collected from each HSP over a 4-day period, and long-term monitoring, with monthly grab samples collected over a 2-year period. The HSPs could be sampled at any river stage, which varied up to 3 meters daily and 4 meters seasonally. Pumping rates were kept low to ensure representative sampling and avoid hydraulic short-circuiting. Short-term increases in river stage did not suppress hexavalent chromium concentrations. Monthly sampling showed that hexavalent chromium concentrations and specific conductance did decline during periods of sustained, seasonally high river stage. Concentrations varied from <2 μg/L during high river stage to 25 μg/L during moderate to low river stage, compared to 50 to 60 μg/L in near-river monitoring wells. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of chlorine and chromium on sulfur solubility in low-activity waste glass

According to an empirical sulfur solubility model developed from over 200 simulated low-activity waste (LAW) glasses, chlorine and chromium show strong effects on lowering sulfur solubility in glass. This work was aimed at understanding the mechanism behind the negative effect of chlorine and chromium on sulfur solubility. A simplified LAW glass was prepared and saturated by sodium sulfate, sodium chloride, and sodium chromate salts as single components and as mixtures with different ratios at 25 mol%, 50 mol%, and 75 mol% of sulfate mixed with chloride or chromate. A crucible-scale salt-saturation was performed by mixing the crushed glass powder with an excess amount of salts, melting at 1150 °C for one hour, and quenching. Three mixing-melting-quenching cycles were applied to determine saturation concentrations of sulfur, chromium, and chlorine incorporated into the simplified LAW glass. The glass compositions were analyzed by inductively coupled plasma–atomic emission spectroscopy, ion chromatography, and X-ray emission spectroscopy. It is proposed that the negative effect of chlorine and chromium on sulfur solubility can be explained based on the simple hypothesis that sulfur, chlorine, and chromium are present in the glass as anions competing for the voids or interstitial sites of the glass matrix, and that their solubility strongly depends on the effective size of corresponding anions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mach 1 oxidation of thoriated nickel chromium at 1204 C /2200 F/.

Electropolished and ground samples of TD-NiCr were exposed to a 1-atm, Mach 1 gas stream at 1204 C for times up to 50 hr. The samples were subjected to both cyclic and isothermal exposure. Weight change, metal loss, X-ray diffraction, metallographic, and electron microprobe analyses were performed. Neither surface preparation nor cyclic-against-isothermal-exposure conditions had a strong effect on the oxidation behavior of the alloy. Initially, a Cr2O3 layer was formed whose volatilization resulted in a very rapid loss of metal - more than 40 microns in the first hour. At about 1 hr, the Cr2O3 layer broke down and NiO began to cover the surface. By 5 hr, the NiO had covered the surface and the rate of loss slowed. The rate-controlling step was diffusion of Cr through NiO.

Lowell, C. E.↗

Self-Lubricating Composite Containing Chromium Oxide

A self lubricating. friction and wear reducing composite material useful over a wide temperature range of from cryogenic temperature up to about 900 C. contains 60 80 wt. % of particulate Cr2O3, dispersed in a metal binder of a metal alloy containing Cr and at least 50 wt. % of Ni, Cr or a mature of Ni and Cr. It also contains 5-20 wt. % of a fluoride of at least one Group I, Group II or rare earth metal and. optionally, 5-20 wt. % of a low temperature lubricant metal, such as Ag. Au, Pt, Pd, Rh and Cu. This composite exhibits less oxidation instability and less abrasiveness than composites containing chromium carbide, is readily applied using plasma spray and can be ground and polished with a silicon carbide abrasive.

Dellacorte, Christopher↗

Temperature-dependent cavity swelling in dual-ion irradiated Fe and Fe-Cr ferritic alloys

Fe-Cr ferritic-martensitic (FM) steels are promising structural material candidates for fusion and advanced fission reactors due to their attractive mechanical properties and volumetric swelling resistance. However, significant discrepancies exist regarding the effect of solutes and irradiation temperature on cavity swelling under ion versus neutron irradiation conditions. In this study, simultaneous dual ion irradiations (8 MeV Ni 3+ ions and energy-degraded 3.5 MeV He 2+ ions) were used to quantify the cavity swelling behavior in ultra-high purity Fe and Fe-Cr alloys (3-14 wt.% Cr), Fe-10 wt.% Cr-780 wt.ppm C, and Eurofer97 FM steel. The irradiations were conducted over a wide temperature range (400-550°C) with a mid-range dose of ~30 displacements per atom (dpa) and 0.1 appm/dpa He implantation rate. Here, using state-of-the-art transmission electron microscopy (TEM), we reveal that pure Fe has a ~50°C lower peak swelling temperature difference than Fe-Cr alloys, which is attributed to higher vacancy mobility in pure Fe. Chromium solute appears to strongly suppress cavity swelling in Fe-Cr alloys for temperatures below ~470°C, but seems to have little effect or slightly enhances swelling above ~470°C. Cavities were observed in all the irradiated samples between 400-550°C. This indicates that the narrow temperature range of observable cavities reported in prior ion irradiated Fe-Cr ferritic alloy studies is likely an artifact associated with the use of low ion energies (<5 MeV), which leads to pronounced near-surface and implanted ion effects that suppress cavity swelling even at midrange depths (particularly at high temperatures).

36 MATERIALS SCIENCE↗

Nanomechanical and tribological properties of nickel–chromium multilayer coating on Inconel 617

Multilayer coatings of Ni and Cr were deposited onto Inconel 617, and multi-scale physical properties were characterized using high temperature tribological experiments, nanoindentation, and microscratch. The effect of high temperature aging (950 °C under helium environment) on two different Ni/Cr multilayer coatings with individual layer thicknesses of 50 and 200 nm denoted by Ni/Cr(50) and Ni/Cr(200) was investigated. Nanoindentation of original coatings showed a hardness of 6 GPa that increases to 14 GPa for both samples once aged. Microscratch results support the macro-tribology results where Ni/Cr(50) (without aging) was the only delaminated coating with significant wear. Additionally, aging in both cases reduced the in situ coefficient of friction and wear. Cross-section energy dispersive spectrometry confirmed that the aged oxide layer was two to three times thicker than the original coating. In conclusion, an abundance of chromium oxide was found in the main body of the coatings, which led to higher hardness and better wear resistance.

36 MATERIALS SCIENCE↗

Pulmonary Edema and Plasma Volume Changes in Dysbarism

Two groups of anesthetized, fasted pigs were utilized. One group of 13 animals (8.5 to 16.6 kilograms) was exposed to a high-pressure environment, and the other group of eight animals (6.9 to 20.0 kilograms) constituted the control group. The experimental group was subjected to an atmosphere of 90 percent nitrogen and 10 percent oxygen at a pressure of 50 psig for 30 minutes and then decompressed at a rate 10 psi/min. Plasma volumes, using both iodine-125-tagged-albumin and chromium-51-tagged-cell dilution techniques, were measured before, immediately after, and at 30 and 60 minutes after decompression. Aortic and right-ventricular systolic pressures were also recorded. At 60 minutes after decompression, blood samples were taken, the animals were sacrificed, and the water content of the lungs, kidneys, livers, and spleens was estimated by measuring tissue wet weight and dry weight. Protein extravasation and tissue blood volumes were determined by measuring the iodine-125-tagged-albumin and chromium-51-tagged-cell spaces in homo-genates of the organs under investigation.

Joki, J. A.↗

A low-input strategy for chromium removal from industrial stormwater using peat sorbent

Low-cost and low-input water treatment systems are important for industrial stormwater remediation. Here we examine a flow-through reactor treatment installation where water exceeds the allowable maximum concentration for drinking water in multiple metals (e.g., chromium [Cr], cadmium [Cd], zinc [Zn]) prior to treatment. Specifically, we seek to understand why Cr attenuated in the reactors is not leachable by identifying the specific chemical form of Cr and dominant mechanisms promoting sequestration in the reactors. Total solid-phase Cr concentration in the peat media ranged from 50 to 150 mg/kg after 1 yr of exposure to stormwater to 300 to 900 mg/kg after 3.5 yr. X-ray fluorescence mapping images show Cr, iron (Fe), and Zn spatially correlated over a scale of 10 μm to 5 mm. Chromium rinds form on the edges of peat particles as Cr accumulates. Chromium and Fe K-edge X-ray absorption near edge structure spectroscopy reveal chromium predominately in the 3+ oxidation state with lesser amounts of elemental Cr. We propose the primary means of chromium attenuation in the reactors is precipitation as Cr-Fe hydroxides combined with trivalent Cr adsorption onto peat surfaces.

36 MATERIALS SCIENCE↗

Analysis of Hydrology and Interim Measure Performance in the Chromium Plume at Los Alamos National Laboratory - 20498

Hexavalent chromium, Cr(VI), is present in the regional aquifer beneath Los Alamos National Laboratory (LANL) at concentrations greater than the New Mexico groundwater standard (50 ppb). The source of the Cr is blowdown from a power plant where potassium dichromate was used as a corrosion inhibitor from 1956 to 1972. Blowdown comingled with effluent from another source and migrated approximately 3 miles down a canyon, primarily as surface flow, until reaching an alluvial infiltration zone. The infiltrating water moved vertically through a thick (approximately 900 ft), complex stratigraphic sequence of unsaturated tuffs, basalt, and unconsolidated alluvial deposits. Horizontal transport also took place within spatially limited perched groundwater horizons in the vadose zone (VZ). Breakthrough at the regional aquifer water table is thought to have occurred in multiple hydraulic windows or 'drip points' located approximately 3 miles from the initial release site at the power plant. The regional aquifer is highly heterogeneous and anisotropic, and displays unconfined behavior in an upper zone and confined behavior at depth. The Cr(VI) contamination has so far remained confined to the upper approximately 25 m of the aquifer. The ambient hydraulic gradient in the regional aquifer is toward the east/southeast, but the water table is extremely flat in the Cr plume area compared to surrounding areas. There is some local variability in flow direction, potentially related to effects of seasonal pumping from nearby Los Alamos county water-supply wells, which draw from the regional aquifer several hundred feet below the water table. An interim measure (IM) is currently operating at the site to achieve hydraulic control of plume migration using a series of extraction wells, ion-exchange treatment, and injection along the downgradient portion of the plume. The migration of Cr contamination in the aquifer has been previously evaluated using a calibrated probabilistic numerical model, which has also been used to design the spatial configuration of extraction and injection wells for the IM, and to identify locations for monitoring wells. The model is built using the Finite Element Heat and Mass (FEHM) transfer code, and the Model Analysis and Decision Support (MADS) software is used for analyses. To date, the portion of the IM system that has operated in a continuous manner has been very effective at hydraulic control. Modifications to the flow field associated with the influence of IM pumping and injection are evaluated here, with modeling constraints to be provided by recent observations of tracers injected into both monitoring wells and IM injection wells, as well as opportunistic observations of geochemical signatures of treated ion-exchange effluent injected into IM injection wells. The tracer and geochemical data provide insights into modified flow directions within the Cr plume area that cannot be otherwise obtained. Results of the modeling work are being used to inform adaptive management of IM operations and will be a valuable tool for development and refinement of long-term remediation strategies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗