Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHROMATICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Surface-Enhanced Raman Imaging of Intracellular Bioreduction of Chromate in Shewanella oneidensis

This proposed research aims to use novel nanoparticle sensors and spectroscopic tools constituting surface-enhanced Raman spectroscopy (SERS) and Fluorescence Lifetime imaging (FLIM) to study intracellular chemical activities within single bioremediating microorganism. The grand challenge is to develop a mechanistic understanding of chromate reduction and localization by the remediating bacterium Shewanella oneidensis MR-1 by chemical and lifetime imaging. MR-1 has attracted wide interest from the research community because of its potential in reducing multiple chemical and metallic electron acceptors. While several biomolecular approaches to decode microbial reduction mechanisms exist, there is a considerable gap in the availability of sensor platforms to advance research from population-based studies to the single cell level. This study is one of the first attempts to incorporate SERS imaging to address this gap. First, we demonstrate that chromate-decorated nanoparticles can be taken up by cells using TEM and Fluorescence Lifetime imaging to confirm the internalization of gold nanoprobes. Second, we demonstrate the utility of a Raman chemical imaging platform to monitor chromate reduction and localization within single cells. Distinctive differences in Raman signatures of Cr(VI) and Cr(III) enabled their spatial identification within single cells from the Raman images. A comprehensive evaluation of toxicity and cellular interference experiments conducted revealed the inert nature of these probes and that they are non-toxic. Our results strongly suggest the existence of internal reductive machinery and that reduction occurs at specific sites within cells instead of at disperse reductive sites throughout the cell as previously reported. While chromate-decorated gold nanosensors used in this study provide an improved means for the tracking of specific chromate interactions within the cell and on the cell surface, we expect our single cell imaging tools to be extended to monitor the interaction of other toxic metal species.

59 BASIC BIOLOGICAL SCIENCES↗

Optimization Of Chromaticity Compensation And Dynamic Aperture In MEIC Collider Rings

The conceptual design of the Medium-energy Electron-Ion Collider (MEIC) at Jefferson Lab relies on an ultra-small beta-star to achieve high luminosities of up to 10{sup 34} cm{sup -2} s{sup -1}. A low-beta insertion for interaction regions unavoidably induces large chromatic effects that demand a proper compensation. The present approach of chromatic compensation in the MEIC collider rings is based on a local correction scheme using two symmetric chromatic compensation blocks that includes families of sextupoles, and are placed in a beam extension area on both sides of a collision point. It can simultaneously compensate the first order chromaticity and chromatic beam smear at the IP without inducing significant second order aberrations. In this paper, we investigate both the momentum acceptance and dynamic aperture in the MEIC ion collider ring by considering the aberration effects up to the third order, such as amplitude dependent tune shift. We also explore the compensation of the third order effects by introducing families of octupoles in the extended beam area.

43 PARTICLE ACCELERATORS↗

Synthesis and characterization of uranyl chromate sheet compounds containing edge-sharing dimers of uranyl pentagonal bipyramids

Eight uranyl chromates have been crystallized from aqueous solution and characterized: Mg(H{sub 2}O){sub 6}[(UO{sub 2}){sub 2}(CrO{sub 4}){sub 2}(OH){sub 2}](H{sub 2}O){sub 3} (1), (NH{sub 4}){sub 2}[(UO{sub 2}){sub 2}(CrO{sub 4}){sub 2}(OH){sub 2}](H{sub 2}O){sub 3}, Rb{sub 2}[(UO{sub 2}){sub 2}(CrO{sub 4}){sub 2}(OH){sub 2}](H{sub 2}O){sub 3} (3), Cs[(UO{sub 2})(CrO{sub 4})(OH)]H{sub 2}O (4), Rb[(UO{sub 2})(CrO{sub 4})(OH)]H{sub 2}O (5) Co(H{sub 2}O){sub 4}(Co(H{sub 2}O){sub 6}){sub 2}[(UO{sub 2}){sub 4}(CrO{sub 4}){sub 6}(OH){sub 2}](H{sub 2}O){sub 4} (6), Li{sub 2}[(UO{sub 2}){sub 2}(CrO{sub 4}){sub 3}](H{sub 2}O){sub 7} (7), and Zn(H{sub 2}O){sub 6}[(UO{sub 2}){sub 2}(CrO{sub 4}){sub 3}](H{sub 2}O){sub 3} (8). The structural units of 1 through 8 each consist of a sheet of uranyl pentagonal bipyramids and (Cr(VI)O{sub 4}){sup 2-} tetrahedra. In each case two uranyl pentagonal bipyramids share an equatorial edge, giving a dimer that is linked into the sheet through vertex sharing with (Cr(VI)O{sub 4}){sup 2-} tetrahedra. The sheets are based upon three distinct sheet anion topologies, and the sheets based on a given anion topology can differ in the orientations of the non-bridging O atoms of (CrO{sub 4}){sup 2-} tetrahedra. The interlayers of these compounds contain either monovalent or divalent cations, as well as H{sub 2}O groups that are either bonded to the interlayer cation or are held in place by H bonding only. We explore the relationships between sheet topologies and interlayer configuration in these compounds. - Graphical abstract: Eight uranyl chromate compounds containing sheet structural units built from uranyl pentagonal bipyramids and (CrO{sub 4}){sup 2-} tetrahedra are reported. Relationships between sheet topologies and interstitial constituents is examined. Highlights: Black-Right-Pointing-Pointer Eight uranyl Cr(VI) compounds with sheet structural units are reported. Black-Right-Pointing-Pointer Relationships between the topology of the uranyl chromate sheets and interlayers are examined. Black-Right-Pointing-Pointer Uranyl and chromate polyhedra form a topologically novel sheet.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of nickel, chromate, and arsenite on histone 3 lysine methylation

Occupational exposure to nickel (Ni), chromium (Cr), and arsenic (As) containing compounds has been associated with lung cancer and other adverse health effects. Their carcinogenic properties may be attributable in part, to activation and/or repression of gene expression induced by changes in the DNA methylation status and histone tail post-translational modifications. Here we show that individual treatment with nickel, chromate, and arsenite all affect the gene activating mark H3K4 methylation. We found that nickel (1 mM), chromate (10 {mu}M), and arsenite (1 {mu}M) significantly increase tri-methyl H3K4 after 24 h exposure in human lung carcinoma A549 cells. Seven days of exposure to lower levels of nickel (50 and 100 {mu}M), chromate (0.5 and 1 {mu}M) or arsenite (0.1, 0.5 and 1 {mu}M) also increased tri-methylated H3K4 in A549 cells. This mark still remained elevated and inherited through cell division 7 days following removal of 1 {mu}M arsenite. We also demonstrate by dual staining immunofluorescence microscopy that both H3K4 tri-methyl and H3K9 di-methyl marks increase globally after 24 h exposure to each metal treatment in A549 cells. However, the tri-methyl H3K4 and di-methyl H3K9 marks localize in different regions in the nucleus of the cell. Thus, our study provides further evidence that a mechanism(s) of carcinogenicity of nickel, chromate, and arsenite metal compounds may involve alterations of various histone tail modifications that may in turn affect the expression of genes that may cause transformation.

60 APPLIED LIFE SCIENCES↗

Improved Method for Evaluating and Specifying the Chromaticity of Light Sources

This article recommends a method for calculating and specifying light source chromaticity using the CIE 2015 10° color matching functions (CMFs), which, according to analysis of existing psychophysical experiment data, can reduce visual mismatch compared to specifications based on the traditional CIE 1931 2° CMFs. Specifically, this work evaluates, documents, and recommends for adoption a supporting system of measures to be used with the CIE 2015 10° CMFs: a new uniform chromaticity scale (UCS) diagram with coordinates (s, t), a measure of correlated color temperature (CCTst), and a measure of distance from the Planckian locus (Dst). It also presents options for updating nominal classification quadrangles. A complete method of this nature has not yet been standardized, which may be contributing to the slow uptake of the CIE 2015 CMFs. The proposed tools are analogous to u, v, CCT, Duv, and the ANSI C78.377 nominal classification quadrangles that are currently specified in the CIE 1960 UCS using the CIE 1931 2° CMFs. While conceptually equivalent, the differences between the current standard method and the new st system are important for reducing unintended mismatch in the chromaticity of light. Furthermore, the implications of changing chromaticity specification methods are identified by a comparison over a diverse set of real light source SPDs. Finally, as a step toward improving the design and specification of light sources for illumination purposes, we propose a process for implementing the recommendations.

42 ENGINEERING↗

Crystal Structure of ChrR -- A Quinone Reductase with the Capacity to Reduce Chromate

The Escherichia coli ChrR enzyme is an obligatory two-electron quinone reductase that has many applications, such as in chromate bioremediation. Its crystal structure, solved at 2.2 {angstrom} resolution, shows that it belongs to the flavodoxin superfamily in which flavin mononucleotide (FMN) is firmly anchored to the protein. ChrR crystallized as a tetramer, and size exclusion chromatography showed that this is the oligomeric form that catalyzes chromate reduction. Within the tetramer, the dimers interact by a pair of two hydrogen bond networks, each involving Tyr128 and Glu146 of one dimer and Arg125 and Tyr85 of the other; the latter extends to one of the redox FMN cofactors. Changes in each of these amino acids enhanced chromate reductase activity of the enzyme, showing that this network is centrally involved in chromate reduction.

59 BASIC BIOLOGICAL SCIENCES↗

Protein Expression Profile of an Environmentally Important Bacterial Strain: the Chromate Response of Arthrobacter Species Strain FB24

The global proteomic response of Arthrobacter sp. strain FB24 to different levels of chromate stress was evaluated with both two-dimensional gel electrophoresis (2-DGE) and liquid chromatography coupled to tandem mass spectrometry (LC/LC-MS/MS) [Henne et al. 2009b]. Proteome coverage of 22% and 71% was obtained with 2-DGE and LC/LC-MS/MS, respectively. The strong response of strain FB24 to chromate suggests a condition of sulfur limitation, which could be driven by competition for the sulfate transporter by the structurally similar chromate ion. Additionally, the involvement of genes hypothesized to be directly involved in chromate resistance in strain FB24 was supported at the protein level.

59 BASIC BIOLOGICAL SCIENCES↗

Symplectic maps and chromatic optics in particle accelerators

Here, we have applied the nonlinear map method to comprehensively characterize the chromatic optics in particle accelerators. Our approach is built on the foundation of symplectic transfer maps of magnetic elements. The chromatic lattice parameters can be transported from one element to another by the maps. We also introduce a Jacobian operator that provides an intrinsic linkage between the maps and the matrix with parameter dependence. The link allows us to directly apply the formulation of the linear optics to compute the chromatic lattice parameters. As an illustration, we analyze an alternating-gradient cell with nonlinear sextupoles, octupoles, and decapoles and derive analytically their settings for the local chromatic compensation. Finally, the cell becomes nearly perfect up to the third-order of the momentum deviation.

43 PARTICLE ACCELERATORS↗

Source of second order chromaticity in RHIC

In this note we will answer the following questions: (1) what is the source of second order chromaticities in RHIC? (2) what is the dependence of second order chromaticity on the on-momentum {beta}-beat? (3) what is the dependence of second order chromaticity on {beta}* at IP6 and IP8? To answer these questions, we use the perturbation theory to numerically calculate the contributions of each quadrupole and sextupole to the first, second, and third order chromaticities.

43 PARTICLE ACCELERATORS↗

Chromaticity correction for a muon collider optics

Muon Collider (MC) is a promising candidate for the next energy frontier machine. However, in order to obtain peak luminosity in the 10{sup 34} cm{sup 2}s{sup -1} range the collider lattice designmust satisfy a number of stringent requirements. In particular the expected large momentum spread of the muon beam and the very small {beta}* call for a careful correction of the chromatic effects. Here we present a particular solution for the interaction region (IR) optics whose distinctive feature is a three-sextupole local chromatic correction scheme. The scheme may be applied to other future machines where chromatic effects are expected to be large. The expected large muon energy spread requires the optics to be stable over a wide range of momenta whereas the required luminosity calls for {beta}* in the mm range. To avoid luminosity degradation due to hour-glass effect, the bunch length must be comparatively small. To keep the needed RF voltage within feasible limits the momentum compaction factor must be small over the wide range of momenta. A low {beta}* means high sensitivity to alignment and field errors of the Interaction Region (IR) quadrupoles and large chromatic effects which limit the momentum range of optics stability and require strong correction sextupoles, which eventually limit the Dynamic Aperture (DA). Finally, the ring circumference should be as small as possible, luminosity being inversely proportional to the collider length. A promising solution for a 1.5 TeV center of mass energy MC with {beta}* = 1 m in both planes has been proposed. This {beta}* value has been chosen as a compromise between luminosity and feasibility based on the magnet design and energy deposition considerations. The proposed solution for the IR optics together with a new flexible momentum compaction arc cell design allows to satisfy all requirements and is relatively insensitive to the beam-beam effect.

43 PARTICLE ACCELERATORS↗

Chromatic and Dispersive Effects in Nonlinear Integrable Optics

Proton accumulator rings and other circular hadron accelerators are susceptible to intensity-driven parametric instabilities because the zero-current charged particle dynamics are characterized by a single tune. Landau damping can suppress these instabilities, which requires energy spread in the beam or introducing nonlinear magnets such as octupoles. However, this approach reduces dynamic aperture. Nonlinear integrable optics can suppress parametric instabilities independent of energy spread in the distribution, while preserving the dynamic aperture. This novel approach promises to reduce particle losses and enable order-of-magnitude increases in beam intensity. In this paper we present results, obtained using the Lie operator formalism, on how chromaticity and dispersion affect particle orbits in integrable optics. We conclude that chromaticity in general breaks the integrability, unless the vertical and horizontal chromaticities are equal. Because of this, the chromaticity correcting magnets can be weaker and fewer correcting magnet families are required, thus minimizing the impact on dynamic aperture.

43 PARTICLE ACCELERATORS↗

Comparative Temporal Proteomics of a Response Regulator (SO2426)-Deficient Strain and Wild-Type Shewanella oneidensis MR-1 During Chromate Transformation

Predicted orphan response regulators encoded in the Shewanella oneidensis MR-1 genome are poorly understood from a cellular function perspective. Our previous transcriptomic and proteomic analyses demonstrated that an annotated DNA-binding response regulator, SO2426, was significantly up-regulated in wild-type S. oneidensis cells at both themRNAand protein levels in response to acute chromate [Cr(VI)] challenge, suggesting a potential regulatory role for this protein in metal stress pathways. To investigate the impact of SO2426 activity on chromate stress response at a genome-wide scale, we describe here comparative and temporal proteome characterizations using multidimensional HPLC-MS/MS and statistical analysis to identify differentially expressed proteins in biological replicates of wild-type S. oneidensis MR-1 and a so2426 deletion ( so2426) strain, which exhibited an impaired Cr(VI) transformation rate compared to that of the parental strain. Global protein profiles were examined at different time intervals (0, 1, 3, 4 h) following exogenous chromate challenge. Results indicated that deletion of the so2426 gene negatively affected expression of a small protein subset (27 proteins) including those with annotated functions in siderophore biosynthesis (SO3032), Fe uptake (SO4743), intracellular Fe storage (Bfr1), and other transport processes. Cr(VI) exposure and subsequent ransformation dramatically increased the number of differentially expressed proteins detected,with up-regulated bundance patterns observed largely for proteins involved in general stress protection and detoxification trategies, cell motility, and protein fate. In addition, the proteome data sets were mined for amino acids with otential post-translational modifications (PTMs) indicative of a level of gene expression regulation extending eyond the transcriptional control imposed by SO2426.

54 ENVIRONMENTAL SCIENCES↗

Chromatic-free spatially resolved optical emission spectroscopy diagnostics for microplasma

A chromatic-free spatially resolved diagnostic system for microplasma measurement is proposed and demonstrated, which consists of an optical chromatic-free microscope mirror system, an electron multiplying charge coupled device (EMCCD), and bandpass filters. The diagnostic system free of chromatic aberrations with a spatial resolution of about 6 {mu}m is achieved. The factors that limit the resolution of this diagnostic system have been analyzed, which are optical diffraction, the pixel size of the EMCCD, and the thickness of the microplasma. In this paper, the optimal condition for achieving a maximum resolution power has been analyzed. With this diagnostic system, we revealed the spatial nonuniformity of a microwave atmospheric-pressure argon microplasma. Furthermore, the spatial distribution of the time-averaged effective electron temperature has been estimated from the intensity distributions of 750.4 and 415.8 nm emissions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical Approach Of The Reduction Of Chromatic And Spherical Aberrations In An Acceleration Lens System For Hundreds Of keV Gaseous Ion Nanobeam

The focused gaseous ion beam (gas-FIB) system composed of a series of electrostatic lenses, called ''acceleration lens system'', has been developed to form nanobeams using gaseous ions generated from a plasma ion source. Ion beams are accelerated and focused simultaneously by a pair of electrodes. A new all-in-one compact acceleration system including an acceleration tube is now under development to form 300 keV ion nanobeam. Chromatic and spherical aberrations are, however, hindrance to form nanobeams with their smaller sizes in diameter. A deceleration lens, which performs like a defocusing lens, was theoretically introduced to downstream of the present acceleration lens system to reduce the aberrations. Ion beam optics simulations were carried out to show that this aberration reduction technique is effective to reduce chromatic and spherical aberrations. As a result, we reduced the chromatic aberration coefficient by 26%, the spherical aberration coefficient by 17% and a beam diameter by 17%, with the deceleration energy of 15 keV. In case of using an electrostatic acceleration tube with 100 mm length, the final beam diameter of 103 nm at 300 keV is obtained by the all-in-one acceleration lens system with the total acceleration length of only 650 mm.

43 PARTICLE ACCELERATORS↗

Geochemical Characterization of Chromate Contamination in the 100 Area Vadose Zone at the Hanford Site - Part 2

At the Hanford Site, chromate was used throughout the 100 Areas (100-B, 100-C, 100-D/DR, 100-F, 100-H, and 100 K) as a corrosion inhibitor in reactor cooling water. Chromate was delivered in rail cars, tanker trucks, barrels, and local pipelines as dichromate granular solid or stock solution. In many occasions, chromate was inevitably discharged to surface or near-surface ground through spills during handling, pipeline leaks, or during disposal to cribs. The composition of the liquids that were discharged is not known and it is quite possible that Cr(VI) fate and transport in the contaminated sediments would be a function of the chemical composition of the waste fluids. The major objectives of this investigation which was limited in scope by the financial resources available, were to 1) determine the leaching characteristics of hexavalent chromium [Cr(VI)] from contaminated sediments collected from 100-D Area spill sites; 2) elucidate possible Cr(VI) mineral and/or chemical associations that may be responsible for Cr(VI) retention in the Hanford Site 100 Areas through the use of macroscopic leaching studies, and microscale characterization of contaminated sediments; and 3) provide information to construct a conceptual model of Cr(VI) geochemistry in the Hanford 100 Area vadose zone that can be used for developing options for environmental remediation. The information gathered from this research effort will help to further improve our understanding of Cr(VI) behavior in the vadose zone and will also help in accelerating the 100 Area Columbia River Corridor cleanup by providing valuable information to develop remedial action based on a fundamental understanding of Cr(VI) vadose zone geochemistry. A series of column experiments were conducted with contaminated sediments to study Cr(VI) desorption patterns. Column experiments used the field size fraction of the sediment samples and a simulated Hanford Site groundwater solution. Periodic stop flow events were applied to evaluate the change in elemental concentration during time periods of no flow and greater fluid residence time. Sediments were characterized for the spatial and mineralogical associations of the contamination using some microscale techniques such as X-ray diffraction, scanning electron microscopy, energy dispersive spectroscopy, X-ray photoelectron spectroscopy, and Mössbauer spectroscopy.

54 ENVIRONMENTAL SCIENCES↗

HEAVY ION FUSION SCIENCE VIRTUAL NATIONAL LABORATORY 1ST QUARTER 2010 MILESTONE REPORT: Simulations of fast correction of chromatic aberrations to establish physics specifications for implementation on NDCX-1 and NDCX-2

This milestone has been accomplished. The Heavy Ion Fusion Science Virtual National Laboratory has completed simulations of a fast correction scheme to compensate for chromatic and time-dependent defocusing effects in the transport of ion beams to the target plane in the NDCX-1 facility. Physics specifications for implementation in NDCX-1 and NDCX-2 have been established. This milestone has been accomplished. The Heavy Ion Fusion Science Virtual National Laboratory has completed simulations of a fast correction scheme to compensate for chromatic and time-dependent defocusing effects in the transport of ion beams to the target plane in the NDCX-1 facility. Physics specifications for implementation in NDCX-1 and NDCX-2 have been established. Focal spot differences at the target plane between the compressed and uncompressed regions of the beam pulse have been modeled and measured on NDCX-1. Time-dependent focusing and energy sweep from the induction bunching module are seen to increase the compressed pulse spot size at the target plane by factors of two or more, with corresponding scaled reduction in the peak intensity and fluence on target. A time-varying beam envelope correction lens has been suggested to remove the time-varying aberration. An Einzel (axisymmetric electric) lens system has been analyzed and optimized for general transport lines, and as a candidate correction element for NDCX-1. Attainable high-voltage holdoff and temporal variations of the lens driving waveform are seen to effect significant changes on the beam envelope angle over the duration of interest, thus confirming the utility of such an element on NDCX-1. Modeling of the beam dynamics in NDCX-1 was performed using a time-dependent (slice) envelope code and with the 3-D, self-consistent, particle-in-cell code WARP. Proof of concept was established with the slice envelope model such that the spread in beam waist positions relative to the target plane can be minimized with a carefully designed Einzel lens waveform and transport line. WARP simulations have verified the efficacy of the Einzel lens while including more detailed beam physics. WARP simulations have also indicated some unpredicted transittime effects, and methods are currently being explored to compensate and reduce this complication. We have explored the use of an Einzel lens, or system of Einzel lenses, to compensate for chromatic aberrations in the beam focal spot in the NDCX-2 target plane. The final beam manipulations in NDCX-2 (linear velocity ramp, charge neutralization, high field final focus solenoid) are similar to NDCX-1 though the NDCX-2 beam has much higher energy and current. The most relevant distinctions are that the pulse duration at the entrance to the drift compression section is tenfold shorter, and that the beam energy tenfold higher, than in NDCX-1. Placing a time-dependent, envelope angle correcting element at the neutralized drift region entrance presents a very significant challenge to voltage holdoff and voltage swing V(t) in a single Einzel lens. Placing the Einzel lens(es) further upstream reduces the required voltage risetime V'(t) to effect the necessary envelope correction, while increasing the duration over which the timedependent voltage must vary. While this simplifies the technological challenge of designing and operating a Einzel lens in NDCX-2, it does require much finer control of the correcting waveform and measurements of its effect on space-charge dominated beams over a much longer axial path length to target than in the NDCX-1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correction of the Chromaticity up to Second Order for MEIC

The proposed electron collider lattice exhibits low β- functions at the Interaction Point (IP) (βx*100mm - βy* 20 mm) and rather large equilibrium momentum spread of the collider ring (δp/p = 0.00158). Both features make the chromatic corrections of paramount importance. Here the chromatic effects of the final focus quadruples are cor- rected both locally and globally. Local correction features symmetric sextupole families around the IP, the betatron phase advances from the IP to the sextupoles are chosen to eliminate the second order chromatic aberration. Global interleaved families of sextupoles are placed in the figure-8 arc sections, and non-interleaved families at straight sec- tion making use of the freely propagated dispersion wave from the arcs. This strategy minimizes the required sex- tupole strength and eventually leads to larger dynamic aper- ture of the collider. The resulting spherical aberrations induced by the sextupoles are mitigated by design; the straight and arc sections optics features an inverse identity transformation between sextupoles in each pair.

43 PARTICLE ACCELERATORS↗

Chromaticity tracking with a phase modulation/demodulation technique in the Tevatron

The Tevatron chromaticity tracker (CT) has been successfully commissioned and is now operational. The basic idea behind the CT is that when the phase of the Tevatron RF is slowly modulated, the beam momentum is also modulated. This momentum modulation is coupled transversely via chromaticity to manifest as a phase modulation on the betatron tune. And so by phase demodulating the betatron tune, the chromaticity can be recovered. However, for the phase demodulation to be successful, it is critical that the betatron tune be a coherent signal that can be easily picked up by a phase detector. This is easily done because the Tevatron has a phase locked loop based tune tracker which coherently excites the beam at the betatron tune.

43 PARTICLE ACCELERATORS↗