Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CERENKOV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Cerenkov emission of acoustic phonons electrically generated from three-dimensional Dirac semimetals

Cerenkov acoustic phonon emission is theoretically investigated in a three-dimensional Dirac semimetal (3DDS) when it is driven by a dc electric field E. Numerical calculations are made for Cd{sub 3}As{sub 2} in which mobility and electron concentration are large. We find that Cerenkov emission of acoustic phonons takes place when the electron drift velocity v{sub d} is greater than the sound velocity v{sub s}. This occurs at small E (∼few V/cm) due to large mobility. Frequency (ω{sub q}) and angular (θ) distribution of phonon emission spectrum P(ω{sub q}, θ) are studied for different electron drift velocities v{sub d} (i.e., different E) and electron concentrations n{sub e}. The frequency dependence of P(ω{sub q}, θ) shows a maximum P{sub m}(ω{sub q}, θ) at about ω{sub m} ≈ 1 THz and is found to increase with the increasing v{sub d} and n{sub e}. The value of ω{sub m} shifts to higher region for larger n{sub e}. It is found that ω{sub m}/n{sub e}{sup 1/3} and P{sub m}(ω{sub q}, θ)/n{sub e}{sup 2/3} are nearly constants. The latter is in contrast with the P{sub m}(ω{sub q}, θ)n{sub e}{sup 1/2 }= constant in conventional bulk semiconductor. Each maximum is followed by a vanishing spectrum at nearly “2k{sub f} cutoff,” where k{sub f} is the Fermi wave vector. Angular dependence of P(ω{sub q}, θ) and the intensity P(θ) of the phonon emission shows a maximum at an emission angle 45° and is found to increase with increasing v{sub d}. P(θ) is found to increase linearly with n{sub e} giving the ratio P(θ)/(n{sub e}v{sub d}) nearly a constant. We suggest that it is possible to have the controlled Cerenkov emission and generation of acoustic phonons with the proper choice of E, θ, and n{sub e}. 3DDS with large n{sub e} and mobility can be a good source of acoustic phonon generation in ∼THz regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-G-TeP2-15: Feasibility Study of Fiber-Optic Cerenkov Radiation Sensors for in Vivo Measurement: Dosimetric Characterization and Clinical Application in Proton Beams

Purpose: To evaluate the possibility of a fiber-optic Cerenkov radiation sensor (FCRS) for in vivo dose verification in proton therapy. Methods: The Cerenkov radiation due to the proton beam was measured using a homemade phantom, consisting of a plastic optical fiber (POF, PGSCD1001-13-E, Toray, Tokyo, Japan) connected to each channel of a multianode photomultiplier tube (MAPMT:H7546, Hamamatsu Photonics, Shizuoka, Japan). Data were acquired using a multi-anode photomultiplier tube with the NI-DAQ system (National Instruments Texas, USA). The real-time monitoring graphic user interface was programmed using Labview. The FCRS was analyzed for its dosimetrics characteristic in proton beam. To determine the accuracy of the FCRS in proton dose measurements, we compared the ionization chamber dose measurements using a water phantom. We investigated the feasibility of the FCRS for the measurement of dose distributions near the superficial region for proton plans with a varying separation between the target volume and the surface of 3 patients using a humanoid phantom. Results: The dose-response has good linearity. Dose-rate and energy dependence were found to be within 1%. Depth-dose distributions in non-modulated proton beams obtained with the FCRS was in good agreement with the depth-dose measurements from the ionization chamber. To evaluate the dosimetric accuracy of the FCRS, the difference of isocenter dose between the delivery dose calculated by the treatment planning system and that measured by the FCRS was within 3%. With in vivo dosimetry using the humanoid phantom, the calculated surface doses overestimated measurements by 4%–8% using FCRS. Conclusion: In previous study, our results indicate that the performance of the array-type FCRS was comparable to that of the currently used a multi-layer ion chamber system. In this study, we also believe that the fiber-optic Cerenkov radiation sensor has considerable potential for use with in vivo patient proton dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

Cerenkov light spectrum in an optical fiber exposed to a photon or electron radiation therapy beam

A Cerenkov signal is generated when energetic charged particles enter the core of an optical fiber. The Cerenkov intensity can be large enough to interfere with signals transmitted through the fiber. We determine the spectrum of the Cerenkov background signal generated in a poly(methyl methacrylate) optical fiber exposed to photon and electron therapeutic beams from a linear accelerator. This spectral measurement is relevant to discrimination of the signal from the background, as in scintillation dosimetry using optical fiber readouts. We find that the spectrum is approximated by the theoretical curve after correction for the wavelength dependent attenuation of the fiber. The spectrum does not depend significantly on the angle between the radiation beam and the axis of the fiber optic but is dependent on the depth in water at which the fiber is exposed to the beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Role of Cerenkov Radiation in the Pressure Balance of Cool Core Clusters of Galaxies

Despite the substantial progress made recently in understanding the role of AGN feedback and associated non-thermal effects, the precise mechanism that prevents the core of some clusters of galaxies from collapsing catastrophically by radiative cooling remains unidentified. In this Letter, we demonstrate that the evolution of a cluster's cooling core, in terms of its density, temperature, and magnetic field strength, inevitably enables the plasma electrons there to quickly become Cerenkov loss dominated, with emission at the radio frequency of ≲350 Hz, and with a rate considerably exceeding free–free continuum and line emission. However, the same does not apply to the plasmas at the cluster's outskirts, which lacks such radiation. Owing to its low frequency, the radiation cannot escape, but because over the relevant scale size of a Cerenkov wavelength the energy of an electron in the gas cannot follow the Boltzmann distribution to the requisite precision to ensure reabsorption always occurs faster than stimulated emission, the emitting gas cools before it reheats. This leaves behind the radiation itself, trapped by the overlying reflective plasma, yet providing enough pressure to maintain quasi-hydrostatic equilibrium. The mass condensation then happens by Rayleigh–Taylor instability, at a rate determined by the outermost radius where Cerenkov radiation can occur. In this way, it is possible to estimate the rate at ≈2 M {sub ⊙} year{sup −1}, consistent with observational inference. Thus, the process appears to provide a natural solution to the longstanding problem of “cooling flow” in clusters; at least it offers another line of defense against cooling and collapse should gas heating by AGN feedback be inadequate in some clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Near threshold response of a wave shifted Cerenkov radiator to heavy ions

The response of Pilot 425 to heavy ions with energies less than 600 MeV/amu beta approximately 0.8 is examined both theoretically and experimentally. Measurements are presented from an experiment which employed a Ne-20 beam at many energies below 575 MeV/amu. The signal is assumed to come from three sources: (1) Cerenkov light from the heavy ion, (2) Cerenkov light from secondary electrons, and (3) scintillation of the radiator. It is found that the effective index of refraction is 1.518 and that scintillation is present at a level of approximately 2.7 percent of the Cerenkov signal for beta = 1 for Ne-20. The first of these values differs from values previously quoted in the literature.

Ahlen, S. P.↗

High resolution Cerenkov and range detectors for balloon-borne cosmic-ray experiment

A combination of an active Cerenkov detector and passive range detectors is proposed for the high resolution measurement of isotopic composition in the neighborhood of iron in the galactic cosmic rays. A large area (4,300 sq cm) Cerenkov counter and passive range detectors were tested. Tests with heavy ions (2.1 GeV/amu C-12, 289 MeV/amu Ar-40, and 594 MeV/amu Ne-20) revealed the spatial uniformity of response of the Cerenkov counter to be better than 1% peak-to-peak. Light collection efficiency is independent of projectile energy and incidence angle to within at least 0.5%. Passive Lexan track recorders to measure range in the presence of the nuclear interaction background which results from stopping particles through 0.9 interaction lengths of matter were also tested. It was found that nuclear interactions produce an effective range straggling distribution only approximately 75% wider than that expected from range straggling alone. The combination of these tested techniques makes possible high mass resolution in the neighborhood of iron.

Ahlen, S. P.↗

Cosmic ray isotope measurements with a new Cerenkov X total energy telescope

Measurements of the isotopic composition of cosmic nuclei with Z = 7-20 are reported. These measurements were made with a new version of a Cerenkov x total E telescope. Path length and uniformity corrections are made to all counters to a RMS level 1%. Since the Cerenkov counter is crucial to mass measurements using the C x E technique - special care was taken to optimize the resolution of the 2.4 cm thick Pilot 425 Cerenkov counter. This counter exhibited a beta = 1 muon equivalent LED resolution of 24%, corresponding to a total of 90 p.e. collected at the 1st dynodes of the photomultiplier tubes.

Webber, W. R.↗

Cerenkov counters for high energy nuclei: Some new developments

A method to determine with gas Cerenkov counters the Lorentz factor, gamma = E/mc, of cosmic ray nuclei with high accuracy over the range gamma approx. 20 to 100 is discussed. The measurement of the Cerenkov emission angle theta, by use of a suitable imaging system is considered. Imaging counters, the ring imaging Cerenkov counters (RICH), were developed for use on accelerators. The image of off-axis particles to determine the amount of image distortion as a function of the direction of the incoming nucleus is examined and an acceptance solid angle, relative to the optical axis, within which the nucleus produces an image with an acceptable level of distortion is defined. The properties of the image, which becomes elliptical, for off-axis particles are analyzed.

Swordy, S. P.↗

Does the Iron K and Alpha: Line of Active Galactic Nuclei Arise from the Cerenkov Line-like Radiation?

When thermal relativistic electrons with isotropic distribution of velocities move in a gas region or impinge upon the surface of a cloud that consists of a dense gas or doped dusts, the Cerenkov effect produces peculiar atomic or ionic emission lines, which is known as the Cerenkov line - like radiation. This newly recognized emission mechanism may find wide applications in high-energy astrophysics. In this paper we tentatively adopt this new line emission mechanism to discuss the origin of the iron Kα feature of active galactic nuclei (AGNs). The motivation of this research is to attempt a solution to a problem encountered by the "disk fluorescence line" model, i.e. , the lack of temporal response of the observed iron Kα line flux to the changes of the X-ray continuum flux. If the Cerenkov line emission is indeed responsible significant ly for the iron Kα feature, the conventional scenario around the central supermassive black holes of AGNs would need to be modified to accomodate more energetic, more violent, and much denser environments than previously thought.

You, J. H.↗

The Track Imaging Cerenkov Experiment

We describe a dedicated cosmic-ray telescope that explores a new method for detecting Cerenkov radiation from high-energy primary cosmic rays and the large particle air shower they induce upon entering the atmosphere. Using a camera comprising 16 multi-anode photomultiplier tubes for a total of 256 pixels, the Track Imaging Cerenkov Experiment (TrICE) resolves substructures in particle air showers with 0.086deg resolution. Cerenkov radiation is imaged using a novel two-part optical system in which a Fresnel lens provides a wide-field optical trigger and a mirror system collects delayed light with four times the magnification. TrICE records well-resolved cosmic-ray air showers at rates ranging between 0.01-0.1 Hz.

Wissel, S. A.↗

The Track Imaging Cerenkov Experiment

We describe a. dedicated cosmic-ray telescope that explores a new method for detecting Cerenkov radiation from high-energy primary cosmic rays and the large particle air shower they induce upon entering the atmosphere. Using a camera comprising 16 multi-anode photomultiplier tubes for a total of 256 pixels, the Track Imaging Cerenkov Experiment (TrICE) resolves substructures in particle air showers with 0,086 deg resolution. Cerenkov radiation is imaged using a novel two-part optical system in which a Fresnel lens provides a wide-field optical trigger and a mirror system collects delayed light with four times the magnification. TrICE records well-resolved cosmic-ray air showers at rates ranging between 0.01-0.1 Hz.

Wissel, S. A.↗

Left-handed metamaterial design for Cerenkov radiation

The design of a new type of left-handed material (LHM), having two dimensions of negative permittivities and one dimension of negative permeability, is presented in this paper for the observation and demonstration of the LH properties of Cerenkov radiation, which is a transverse magnetic (TM) electromagnetic wave. For a unit cell's dimension of 5 mm, a LH band is observed between 6 and 7 GHz upon a TM incidence. We also use an antenna array to model a traveling current source, representing a single frequency component of a moving charged particle, demonstrating the feasibility and basis of observing backward Cerenkov radiation experimentally with LHM.

36 MATERIALS SCIENCE↗

Mode-coupling Cerenkov sum-frequency-generation in a multimode planar waveguide

We present experimental and theoretical studies of the mode-coupling Cerenkov sum-frequency radiations in a multimode LiNbO{sub 3} planar waveguide. The radiations result from the coupling of different guided modes of the fundamental wave, which have the same optical frequencies but different propagation constants. At the same time, scattering-involved Cerenkov sum-frequency-generation was also observed and discussed. Our theoretical predictions are in well accordance with the experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of saturation phenomena in Cerenkov free-electron lasers with a planar waveguide

In this paper, the operation of the stimulated emission in Cerenkov free-electron laser (CFEL) is studied on the basis of the modulations of electron velocity and density by the electromagnetic (EM) field. The influence of the electron relaxation, due to mutual electrons collisions, on the electron dynamics is taken into account. We investigate the growth characteristics of Cerenkov laser operating in the small-signal and saturation regimes. In the saturation regime, the effect of velocity reduction of the electron beam on the gain dynamics is demonstrated. We also show that our results match with those of other well-known treatments in the small-signal gain limit.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cascaded Cerenkov third-harmonic generation in random quadratic media

We investigate experimentally and theoretically the conical emission of Cerenkov-type third-harmonic generation in strontium barium niobate of random 2D-{chi}{sup (2)} distribution. The azimuthal intensity distribution is explained by the polarization properties of the fundamental and Cerenkov second-harmonic waves, depending on the cascaded origin of the generation process. Moreover, we show the role of the individual domain shape in an additional modulation on the conical emission, controlled by the electrical switching of the spontaneous polarization of the ferroelectric medium.

36 MATERIALS SCIENCE↗

SU-F-T-174: Patient-Specific Point Dose Measurement Using Fiber Optic Radiation Sensor Using Cerenkov Radiation for Proton Therapeutic Beam

Purpose: A fiber-optic radiation sensor using Cerenkov radiation (FOCR) has been widely studied for use as a dosimeter for proton therapeutic beam. We developed the FOCR, and it applied to patient-specific point dose measurement in order to evaluate the effectiveness of the FOCR system for proton therapy QA. Methods: Calibration of FOCR was performed with an ionization chamber whose absolute doses were determined according to the IAEA TRS-398 protocol. To determine the calibration curve, the FOCR was irradiated perpendicularly to the proton beam at the 13 dose levels steps. We selected five actual patient treatment plans performed at proton therapy center and compared the resulting FOCR measurements with the ionization chamber measurements. Results: The Cerenkov light yield of the FOCR increases linearly with as the dose measured using the ionization chamber increases from 0 cGy to 500 cGy. The results indicate that the fitting curve is linear, suggesting that dose measurement based on the light yield of the FOCR is possible. The results of proton radiation dose QA performed using the FOCR for 10 proton fields and five patients are good agreement with an ionization chamber. Conclusion: We carried out the patient QA using the FOCR for proton therapeutic beam and evaluated the effectiveness of the FOCR as a proton therapy QA tool. Our results indicate that the FOCR is suitable for use in patient QA of clinical proton beams.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP3-06: Nanoparticle-Aided External Beam Radiotherapy Leveraging the Cerenkov Effect

Purpose: This study investigates the feasibility of exploiting the Cerenkov radiation (CR) present during external beam radiotherapy (EBRT) for significant therapeutic gain, using titanium dioxide nanoparticles (titania) delivered via a new design of radiotherapy biomaterials. Methods: Recently published work has shown that CR generated by radionuclides during PET imaging could substantially enhance damage to cancer cells in the presence of 0.625 µg/g titania. We hypothesize that equal or greater damage can be achieved during EBRT. To test this hypothesis, Monte Carlo simulation was done using GEANT4 in order to get the total CR yield inside a tumor volume during EBRT compared to that of the radionuclides. We considered a novel approach where a sufficiently potent concentration of the titania was delivered directly into the tumor using radiotherapy biomaterials (e.g. fiducials) loaded with the titania. The intra-tumor distribution/diffusion of titania released from the fiducials was calculated. An in-vitro MTS assay experiment was also carried out to establish the relative non-toxicity of titania for concentrations of up to 1 µg/g. Results: For a radiotherapy biomaterial loaded with 15 µg/g of 2-nm titania, at least 0.625 µg/g could be delivered through out a tumor sub-volume of 2-cm diameter after 14 days. This concentration level could inflict substantial damage to tumor cells during EBRT. The Monte Carlo results showed the CR yield in tumor by 6 MV radiation was higher than the radionuclides and hence potentially greater damage may be obtained during EBRT. No significant cell viability change was observed for 1 µg/g titania. Conclusion: Altogether, these preliminary findings demonstrate a potential new approach that can be used to take advantage of the CR present during megavoltage EBRT to boost damage to tumor cells. The results provide significant impetus for further experimental studies towards development of nanoparticle-aided EBRT powered by the Cerenkov effect.

60 APPLIED LIFE SCIENCES↗

Frequency of light-flashes induced by Cerenkov radiation from heavy cosmic-ray nuclei

The expected frequency was calculated for light flashes induced in the dark-adapted eye by Cerenkov radiation from the flux of heavy nuclei that exists in space beyond the geomagnetic field. The expected frequency of light flashes depends on the threshold number of photons that must be absorbed in a rod cluster. The results of the calculation are presented as a curve of the mean frequency of light flashes versus the threshold number of absorbed photons. The results are not sensitive to variations in the path length from 5 to 15 grams per square centimeter of water-equivalent before the nucleus reaches the retina. Calculations were based on the fluxes and energy spectra of galactic cosmic ray nuclei of helium to iron, measured at a time of minimum solar modulation. The expected light flash frequencies induced by Cerenkov radiation are consistent with the frequencies reported by the astronauts on Apollo missions 11 through 14.

Madey, R.↗