Engineering PapersSearch

SEARCH · Engineering Papers

Results for “CAVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Progress and Challenges in Traveling-Wave SRF cavity development at Fermilab

Traveling-wave (TW) technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the limit of 50~60MV/m in Standing-wave (SW) technology. The early stages of TW SRF cavity developments had been funded by several SBIR grants to Euclid Techlabs and completed in collaboration with Fermilab through a 1-cell prototype and a proof-of-principle 3-cell TW cavity. The TW resonance excitation in the 3-cell TW cavity at 2K was demonstrated through the low power RF test in early 2024. A high-power test of the 3-cell in TW mode being prepared. To advance a design and technology to fabricate a novel high gradient TW SRF cavity, FNAL proposed a half-meter TW RF design and R&Ds to realize that are in progress. Here we will report the recent progress in the 3-cell TW cavity and the challenges towards a half-meter scale TW cavity.

Furuta, F.

Excellent performance of 650 MHz single-cell niobium cavity after electropolishing

Electropolishing process and cathodes have undergone modification and optimization for both low- and high-beta 650 MHz five-cell niobium cavities for PIP-II. Cavities treated with these modified electropolishing conditions exhibited smooth surfaces and good performance in baseline tests. Nonetheless, due to administrative constraints on project cavities, maximum gradient performance testing was not conducted. This paper presents a study conducted on a single-cell 650 MHz cavity utilizing the optimized electropolishing conditions, highlighting the maximum performance attained for this specific cavity. The cavity tested at 2 K in a vertical cryostat reached a superior accelerating field gradient of 53.3 MV/m at Q0 of 1.6x1010, which is the highest gradient attained for this type of large-sized cavities.

43 PARTICLE ACCELERATORS

Nb3Sn Superconducting Radiofrequency Cavity Fabricated by Sputter Deposition from a Stoichiometric Target

Nb$_3$Sn is a promising coating material for superconducting radiofrequency cavities in next-generation accelerators due to its higher superconducting transition temperature (~18.3 K) and superheating field (~400 mT), offering the potential to surpass the intrinsic performance limits of bulk niobium. We developed a sputter coating technique employing a stoichiometric target to fabricate Nb$_3$Sn films on the inner surfaces of niobium cavities. A Nb$_3$Sn tube target, prepared by growing a >20 m thick Nb$_3$Sn coating on the surface of a Nb tube via a Sn vapor diffusion process, was used in a DC cylindrical magnetron sputtering system. Approximately 170 nm thick Nb-Sn films were sputter-coated onto flat Nb substrates positioned to replicate the beam tube and equator regions of a 2.6 GHz cavity, followed by annealing at 950 °C for 3 hours to form Nb$_3$Sn. The composition, morphology, and structure of the annealed Nb$_3$Sn films were examined. Then, a ~1.2 m-thick film was sputter-coated onto the interior of a 2.6 GHz Nb cavity following the procedure developed for the flat samples. The cavity was subsequently annealed under the same conditions used for the flat samples. Cryogenic RF testing of the sputter-coated cavity demonstrated a T$_c$ of approximately 17.8 K, consistent with Nb$_3$Sn layer. Subsequently, the cavity underwent a light Sn recoating followed by a vapor diffusion Nb$_3$Sn coating process, achieving a quality factor of approximately 8.5 × 10$^9$ and an accelerating gradient of up to 11.3 MV/m at 4.2 K.

Shakel, Md Sharifuzzaman [Old Dominion U.; Jeffers

Neural-Network Inverse Design of SRF Cavities and Transmons for Bosonic Quantum Computation

Three-dimensional superconducting radio-frequency (SRF) cavities provide exceptionally long-lived electromagnetic modes and, when coupled to nonlinear elements such as transmon qubits, become promising architectures for bosonic quantum information processing. The inverse design of such systems, i.e., recovering device geometries that produce specified electromagnetic and coupling targets, is generally a one-to-many problem. The qubit-cavity coupling strength depends sensitively on both the transmon geometry and its position within the cavity's electromagnetic field. As these systems scale up and their design parameter spaces grow, the cost of conventional iterative simulation becomes prohibitive. We present two deep neural network (DNN) approaches that address this inverse-design problem at complementary levels of the design stack. The first proposes SRF cavity geometries that produce target cavity observables. The second proposes transmon qubit designs that produce target qubit-cavity parameters - the coupling rate, qubit frequency, and anharmonicity $(g, ν_q, α)$. The recovered candidate designs match the targets to within ~5% (cavity) and ~2% (transmon), confirmed by end-to-end re-simulation. Both approaches map desired device behavior directly to candidate designs, a fast alternative to the iterative simulation studies usually required.

Yaker, Joseph [Fermilab; Northwestern U.]

Axion dark matter search with a photonic bandgap cavity haloscope and dielectric tuning rod over 10.25-10.45 GHz

We report the development of a new widely tunable cavity and demonstrate its use in a search for dark matter axions. We achieve unloaded quality factors above $10^{5}$, roughly $25\times$ larger than a bare copper cavity at the same frequency, using concentric sapphire shells to reduce Ohmic losses on the cavity barrel. A rotating sapphire rod tunes our cavity mode over the $10.1-11.7$ GHz range, approximately $16\%$ of its resonant frequency. Using an amplified receiver chain, we demonstrate sensitivity to new axion parameter space by tuning the cavity over the $200$ MHz range between $10.25-10.45$ GHz (42.4 - 43.2, $μ$eV) to constrain the axion-to-photon coupling to $|g_{aγγ}|$$\leq$ 1 $\times$$10^{-12}$${GeV}^{-1}$. This cavity can scan its tuning range about $9$ times faster compared to a bare copper cavity when paired with a photon counting device, laying the groundwork for a definitive search for the QCD axion over $10.1-11.7$ GHz.

Lynn, Morgan [Chicago U.]

Effects of break geometry and orientation on helium-air mixing in simulated reactor cavities of high temperature gas reactors

Here, this study experimentally examined the spatial and temporal variations in air and helium concentrations and temperature fields within simulated reactor cavities of a High Temperature Gas Reactor (HTGR) following helium discharge into an initially air-filled reactor cavity system. Detailed temperature maps were generated using a combination of fiber optics temperature sensor and multiple thermocouple probes within the simulated reactor cavities. The research scenario involved a hypothetical small pipe break in the Reactor Pressure Vessel, resulting in the release of high-temperature helium into the surrounding cavity. A scaled multi-compartment experimental facility, modeled after the General Atomics Modular High Temperature Gas Reactor (GA-MHTGR) design, was constructed for helium and air mixing experiments. Oxygen sensors and thermocouple probes were installed in all five cavities to measure the concentrations of oxygen (or helium) and the temperature distributions of the gas mixture. The experimental findings highlighted the significant impact of the injected helium jet velocity on the gas mixing process and demonstrated how the direction of the helium jet influences the air-helium temperature profiles within the cavities.

Air-ingress

First characterisation of the MAGO cavity, a superconducting RF detector for kHz–MHz gravitational waves

Heterodyne detection using microwave cavities is a promising method for detecting high-frequency gravitational waves (GWs) or ultralight axion dark matter. In this work, we report on studies conducted on a spherical 2-cell cavity developed by the MAGO collaboration for high-frequency GWs detection. Although fabricated around 20 years ago, the cavity had not been used since. Due to deviations from the nominal geometry, we conducted a mechanical survey and performed room-temperature plastic tuning. Measurements and simulations of the mechanical resonances and electromagnetic properties were carried out, as these are critical for estimating the cavity’s GW coupling potential. Based on these results, we plan further studies in a cryogenic environment. The cavity characterisation does not only provide valuable experience for a planned physics run but also informs the future development of improved cavity designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Reducing experimental uncertainty in the calculation of cavity swelling in a transmission electron microscope through crystallographically aided void volume tracking

Accurate measurement of cavity swelling in a transmission electron microscope is essential to define material performance under irradiation, and the conventionally applied spherical assumption for the calculation of cavity volumes in irradiated materials can result in errors ranging between a 25% underestimation and 72% overestimation of volume purely based on the assumption of shape. This assumption is undeniably expedient for calculation but does not sufficiently account for the 3D nature of polyhedral cavities and their shape projection in the transmission electron microscope, and therefore presents too large of an associated uncertainty in swelling determination for faceted cavities. This uncertainty has been defined for many common cavity shapes in FCC and BCC crystal systems, and has been tabulated across the cubic fundamental region. A revised methodology for crystallographically aided void volume tracking, or CAVV-T, is presented and demonstrated on a specimen of neutron irradiated Ni. In-depth discussion on the application of this technique is provided along with resources to allow for conversion between the spherical assumption and this revised method. This work seeks to increase experimental confidence in the characterization and quantification of critical aspects of irradiation damage in materials by applying a crystallographically-resolved approach for cavity swelling calculation.

Haag IV, James V. [Pacific Northwest National Labo

The first high-redshift cavity power measurements of cool-core galaxy clusters with the International LOFAR Telescope

Radio-mode feedback associated with the active galactic nuclei (AGNs) at the cores of galaxy clusters injects a large amount of energy into the intracluster medium (ICM), offsetting radiative losses through X-ray emission. This mechanism prevents the ICM from rapidly cooling down and fueling extreme starburst activity as it accretes onto the central galaxies, and it is therefore a key ingredient in the evolution of galaxy clusters. However, the influence and mode of feedback at high redshifts (z ∼ 1) remains largely unknown. Low-frequency sub-arcsecond-resolution radio observations taken with the International LOFAR Telescope have demonstrated their ability to assist X-ray observations with constraining the energy output from the AGNs (or “cavity power”) in galaxy clusters, thereby enabling research at higher redshifts than before. In this pilot project, we tested this hybrid method on a high-redshift (0.6 < z < 1.3) sample of 13 galaxy clusters for the first time with the aim of verifying the performance of this method at these redshifts and providing the first estimates of the cavity power associated with the central AGN for a sample of distant clusters. We were able to detect clear radio lobes in three out of 13 galaxy clusters at redshifts of 0.7 < z < 0.9, and we used these detections in combination with ICM pressures surrounding the radio lobes obtained from standard profiles to calculate the corresponding cavity powers of the AGNs. Combining our results with the literature, the current data appear to suggest that the average cavity power peaked at a redshift ofz ∼ 0.4 and slowly decreases toward higher redshifts. However, we require more and tighter constraints on the cavity volume and a better understanding of our observational systematics to confirm any deviation of the cavity power trend from a constant level.

Astronomy & Astrophysics

A Flux-Tunable cavity for Dark matter detection

Developing a dark matter detector with wide mass tunability is an immensely desirable property, yet it is challenging due to maintaining strong sensitivity. Resonant cavities for dark matter detection have traditionally employed mechanical tuning, moving parts around to change electromagnetic boundary conditions. However, these cavities have proven challenging to operate in sub-Kelvin cryogenic environments due to differential thermal contraction, low heat capacities, and low thermal conductivities. Instead, we develop an electronically tunable cavity architecture by coupling a superconducting 3D microwave cavity with a DC flux tunable SQUID. With a flux delivery system engineered to maintain high coherence in the cavity, we perform a hidden-photon dark matter search below the quantum-limited threshold. A microwave photon counting technique is employed through repeated quantum non-demolition measurements using a transmon qubit. With this device, we perform a hidden-photon search and constrain the kinetic mixing angle to ${\varepsilon}< 8.2\times 10^{-15}$ in a tunable band from 5.672 GHz to 5.694 GHz. By coupling multimode tunable cavities to the transmon, wider hidden-photon searching ranges are possible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Niobium coaxial cavities with internal quality factors exceeding 1.4 × 10 9 for circuit quantum electrodynamics

Group-V materials such as niobium and tantalum have become popular choices for extending the performance of circuit quantum electrodynamics (cQED) platforms, allowing for quantum processors and memories with reduced error rates and more modes. The complex surface chemistry of niobium, however, makes identifying the main modes of decoherence difficult at millikelvin temperatures and single-photon powers. We use niobium coaxial quarter-wave cavities to study the impact of etch chemistry, prolonged atmospheric exposure, and the significance of cavity conditions prior to and during cooldown—in particular, niobium hydride evolution—on single-photon coherence. We demonstrate cavities with quality factors Q int ≳ 1.4 × 10 9 in the single-photon regime, a 15-fold improvement over aluminum cavities of the same geometry. We rigorously quantify the sensitivity of our fabrication process to various loss mechanisms and demonstrate a two- to fourfold reduction in the two-level system loss tangent and a three- to fivefold improvement in the residual resistance over traditional buffered chemical polishing etching techniques. Finally, we demonstrate transmon integration and coherent cavity control while maintaining a cavity coherence of 11.3 ms. The accessibility of our method, which can be easily replicated in academic laboratory settings, together with the demonstration of its performance, mark an advancement in three-dimensional cQED.

Oriani, Andrew E. [Chicago U., EFI; Chicago U.] (O

Performance of Oak Ridge National Laboratory spallation neutron source proton power upgrade cavities and cryomodule production

The Proton Power Upgrade initiative at Oak Ridge National Lab’s Spallation Neutron Source aims to greatly boost the capability of proton beam power. This upgrade involves the integration of seven additional cryomodules, each housing four six-cell high-beta ( β = 0.81 ) superconducting radio frequency cavities. These cavities, manufactured and processed by Research Instruments in Germany, underwent meticulous treatment, including electropolishing as the bulk and final vital step. Upon delivery to Jefferson Lab, a total of 28 cavities for seven cryomodules, along with an additional four cavities for a spare cryomodule, underwent thorough vertical qualification tests, meeting the required specifications. Following cavity tanking and subsequent rf testing, the assembly of eight cryomodules was successfully executed, with all 32 cavities demonstrating compliance with acceptance criteria. The transportation of the cryomodule to SNS for high-power testing in the tunnel yielded exceptional results. Notably, the performance surpassed specifications, in terms of quality factor and accelerating gradient. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS

Deepest sensitivity to wavelike dark photon dark matter with superconducting radio frequency cavities

Wavelike, bosonic dark matter candidates like axions and dark photons can be detected using microwave cavities known as haloscopes. Traditionally, haloscopes consist of tunable copper cavities operating in the TM 010 mode, but ohmic losses have limited their performance. In contrast, superconducting radio frequency (SRF) cavities can achieve quality factors of ∼ 10 10 , perhaps 5 orders of magnitude better than copper cavities, leading to more sensitive dark matter detectors. In this paper, we first derive that the scan rate of a haloscope experiment is proportional to the loaded quality factor Q L , even if the cavity bandwidth is much narrower than the dark matter halo line shape. We then present a proof-of-concept search for dark photon dark matter using a nontunable ultrahigh-quality SRF cavity. We exclude dark photon dark matter with kinetic mixing strengths of χ > 1.5 × 10 − 16 for a dark photon mass of m A ′ = 5.35 μ eV , achieving the deepest exclusion to wavelike dark photons by almost an order of magnitude. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

High-$Q_0$ treatment of CEBAF 1.5 GHz SRF cavities

The Continuous Electron Beam Accelerator Facility (CEBAF) was the first large-scale accelerator to employ superconducting radiofrequency (SRF) cavities for continuous-wave operation. Ongoing research and development efforts continue to focus on increasing the intrinsic quality factor (Q 0 ) of these cavities in order to reduce cryogenic losses while maintaining operational gradients. Here, in this work, we report on the application of high-Q 0 surface treatments to single-cell and multicell C100 and C75 style 1.5 GHz niobium cavities used in the CEBAF accelerator. Nitrogen infusion and oxygen alloying via medium-temperature baking were applied under heat-treatment constraints relevant to existing cavity hardware. Both processes yielded substantial improvements in Q 0 at moderate accelerating gradients, achieving values of approximately 2 × 10 10 at 2.07 K and 20 MV/m. The effectiveness of nitrogen infusion at reduced annealing temperatures and the successful extension of oxygen alloying to multicell cavities are demonstrated. These results establish viable pathways for implementing high-Q 0 treatments in CEBAF-compatible cavities and support future integration into cryomodules for reduced operational cryogenic load.

Dhakal, Pashupati [Thomas Jefferson National Accel

Multiplexed color centers in a silicon photonic cavity array

Entanglement distribution is central to the modular scaling of quantum processors and establishing quantum networks. Color centers with telecom-band transitions and long spin coherence times are suitable candidates for long-distance entanglement distribution. However, high-bandwidth memory-enhanced quantum communication is limited by high-yield, scalable creation of efficient spin-photon interfaces. Here, we develop a silicon photonics platform consisting of arrays of bus-coupled cavities. The coupling to a common bus waveguide enables simultaneous access to individually addressable cavity-enhanced T center arrays. We demonstrate frequency-multiplexed operation of two T centers in separate photonic crystal cavities. In addition, we investigate the cavity enhancement of a T center through hybridized modes formed between physically distant cavities. Our results show that bus-coupled arrays of cavity-enhanced color centers could enable efficient on-chip and long-distance entanglement distribution.

Komza, Lukasz

Simulation of the thermoelectric effect in a multi-metallic superconducting cavity

Superconducting radio-frequency accelerating cavities made with different material layers, such as copper, Nb or Nb₃Sn, are susceptible to thermoelectric effects due to differences in Seebeck coefficients between the metals. A temperature gradient across the surfaces can drive thermoelectric currents, which may impact the cavity performance. A layered Cu/Nb/Nb3Sn single-cell cavity was tested with cryocoolers in 2022. Three heaters were mounted on the cavity surface at different locations and three single-axis cryogenic fluxgate magnetometers were attached close to the cavity equator. A linear increase in the magnetic field was measured while increasing the heaters' power. The cavity setup was analyzed with COMSOL and the results showed a trend similar to that observed in the experiment. This contribution details the approach chosen for the simulation and some of the challenges encountered.

Accelerator Physics

Plasma processing of SRF cavities at Jefferson Lab: Experiment results and simulation insight

Plasma processing of superconducting radio frequency (SRF) cavities has been an active research effort at Jefferson Lab (JLab) since 2019, aimed at enhancing cavity performance by removing hydrocarbon contaminants and reducing field emission. In this experiment, processing using argon-oxygen and helium-oxygen gas mixtures to find minimum ignition power at different cavity pressure was investigated. Ongoing simulations are contributing to a better understanding of the plasma surface interactions and the fundamental physics behind the process. These simulations, combined with experimental studies, guide the optimization of key parameters such as gas type, RF power, and pressure to ignite plasma using selected higher-order mode (HOM) frequencies. This paper presents experimental data from argon-oxygen and helium-oxygen gas mixture C75 and C100 cavity plasma ignition studies, as well as simulation results for the C100-type cavity based on the COMSOL model previously applied to the C75 cavity.

Accelerator Physics

Unveiling the Interplay: Cold Work, Recrystallization, and Flux Expulsion in SRF Cavities

The fabrication of SRF cavities from sheet materials includes deep-drawing, electron beam welding, chemical and mechanical polishing, high-temperature heat treatment, and material diffusion. The performance of these cavities is frequently limited by magnetic flux trapping giving rise to additional rf loss. In this presentation, we thoroughly examine how recrystallization influences flux expulsion in SRF cavities, using cold-worked niobium sheets from various suppliers. Our findings reveal that cold-worked sheets enhance flux expulsion, especially at lower heat treatment temperatures, by promoting improved recrystallization. In particular, a traditionally fabricated Nb cavity half-cell from an annealed poly-crystalline Nb sheet after an 800 C heat treatment leads to a bi-modal microstructure that ties in with flux trapping and inefficient flux expulsion. This non-uniform microstructure is related to varying strain profiles along the cavity shape. A novel approach to prevent this non-uniform microstructure is presented by fabricating a 1.3 GHz single cell Nb cavities with a cold-worked sheet and subsequent heat treatment leading to better flux expulsion after 800 C/3h

Dhakal, P. [Old Dominion Univ., Norfolk, VA (Unite