Apparent movement phenomena on CRT displays - Threshold determinations of apparent movements of pulsed light sources
Apparent movement phenomena on cathode ray tube displays - threshold determinations of apparent movements of pulsed light sources
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Apparent movement phenomena on cathode ray tube displays - threshold determinations of apparent movements of pulsed light sources
A low-cost, low-mass, electrically efficient, modular cathode/electron gun assembly has been developed by FDE Inc. of Beaverton, Oregon, under a Small Business Innovation Research (SBIR) contract with the NASA Glenn Research Center at Lewis Field. This new assembly offers significant improvements in the design and manufacture of microwave and millimeter wave traveling-wave tubes (TWT's) used for radar and communications. It incorporates a novel, low-heater-power, reduced size and mass, high-performance barium dispenser type thermionic cathode and provides for easy integration of the cathode into a large variety of conventional TWT circuits. Among the applications are TWT's for Earth-orbiting communication satellites and for deep space communications, where future missions will require smaller spacecraft, higher data transfer rates (higher frequencies and radiofrequency output power), and greater electrical efficiency. A particularly important TWT application is in the microwave power module (a hybrid microwave/millimeter wave amplifier consisting of a low-noise solid-state driver, a small TWT, and an electronic power conditioner integrated into a single compact package), where electrical efficiency and thermal loading are critical factors and lower cost is needed for successful commercialization. The design and fabrication are based on practices used in producing cathode ray tubes (CRT's), which is one of the most competitive and efficient manufacturing operations in the world today. The approach used in the design and manufacture of thermionic cathodes and electron guns for CRT's has been optimized for fully automated production, standardization of parts, and minimization of costs. It is applicable to the production of similar components for microwave tubes, with the additional benefits of low mass and significantly lower cathode heater power (less than half that of dispenser cathodes presently used in TWT s). Modular cathode/electron gun assembly. The modular cathode/electron gun assembly consists of four subassemblies the cathode, the focus electrode, the header (including the electrical feedthroughs), and the gun envelope (including the anode) a diagram of which is shown. The modular construction offers a number of significant advantages, including flexibility of design, interchangeability of parts, and a drop-in final assembly procedure for quick and accurate alignment. The gun can accommodate cathodes ranging in size from 0.050 to 0.250-in. in diameter and is applicable to TWT's over a broad range of sizes and operating parameters, requiring the substitution of only a few parts: that is, the cathode, focus electrode, and anode. The die-pressed cathode pellets can be made with either flat or concave (Pierce gun design) emitting surfaces. The gun can be either gridded (pulse operation) or ungridded (continuous operation). Important factors contributing to low cost are the greater use of CRT materials and parts, the standardization of processes (welding and mechanical capture), and tooling amenable to automated production. Examples are the use of simple shapes, drawn or stamped metal parts, and parts joined by welding or mechanical capture. Feasibility was successfully demonstrated in the retrofit and testing of a commercial Kaband (22-GHz) TWT. The modular cathode/electron gun assembly was computer modeled to replicate the performance of the original electron gun and fabricated largely from existing CRT parts. Significant test results included demonstration of low heater power (1.5-W, 1010 C brightness temperature for a 0.085-in.-diameter cathode), mechanical ruggedness (100g shock and vibration tests in accordance with military specifications (MIL specs)), and a very fast warmup. The results of these tests indicate that the low-cost CRT manufacturing approach can be used without sacrificing performance and reliability.
Camera with characteristics of vidicon camera and greater resolution than home TV receiver uses mosaic of phototransistors. Because of low power and small size, camera has many applications. Mosaics can be used as cathode ray tubes and analog-to-digital converters.
Computer based data conditioning and display technique detects incipient failure in servo system testing, for use in prelaunch checkout of complex nonlinear servomechanisms. These phase plane displays enable identification of, on line, unusual or abnormal servo responses which can be displayed compactly in the time domain on a cathode ray tube.
System measures the spatial distribution of high-velocity droplets ejected from a nozzle or spray gun. The system employs an electrically resistive grid as the sensing screen, electrical leads, and a signal scanner such as a cathode ray tube.
Multilayer, dielectric, thin film optical filter evaluation using cathode ray tube display device
Thermochromic materials for display devices and their application as screen materials in cathode ray tube phosphors
OGO operations monitor computer programming and cathode ray tube display subsystem
Univac 1108 computer system of cathode ray tube screens for time sharing, data retrieval, and data storage
Superlinear and sublinear phosphors combined for producing single gun color cathode ray tubes
Computer generated cathode ray tube display of diastolic and systolic ventricle shape during gravitational stress
Scanned laser beam display techniques based on cathode ray tube technology, noting flying spot scanner and beam deflection
Electrocardiogram is displayed as a contourogram on the cathode ray tube of a variable-persistence oscilloscope. Each cycle is stacked below its predecessors giving a three dimensional effect. A major change in the signal is apparent as a change in the contourogram pattern.
Langley interactive computerized circuit analysis capability /LICCA/ enables designer to draw electronic circuit diagrams on cathode ray tube screen. This information is submitted as input to user-selected circuit analysis program. LICCA accommodates binary logic circuits and circuits with discrete components, and monitors operator's instructions to detect errors.
Superlinear phosphor behavior analysis for single gun color cathode ray tube development
Device uses pattern of transparent contact touch points that are put on cathode ray tube screen. Touch point system compels more precise and unambiguous communication between man and machine than is possible with any other means, and speeds up operation responses.
Device, serving as substitute for cathode ray tubes, applies to computer input-output devices such as microfilm readers, data displays, and optical scanners. Each device operates at speed of modern computer.
Investigating video image display assembly and discernibility of cathode ray tube gray shades for SFOF development