Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CASE METHOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Results of ISO/TS 6336-22 Evaluating Full Contact Zone

ISO/TS 6336-22 (Calculation of load capacity of spur and helical gears - Part 22: Calculation of micropitting load capacity) is the ISO technical specification containing a proposal for calculations of the risk of micropitting in gear sets. Micropitting is a Hertzian fatigue phenomenon that appears as ultra-fine cracking and pitting on the flanks of gear teeth. Since progressive micropitting can lead to macropitting and flank damage, critical applications such as wind turbines, marine drives, and high-speed gear drives seek to accurately predict whether their designs are susceptible to this damage. ISO/TS 6336-22 assesses micropitting risk through a safety factor which is calculated as the minimum specific film thickness in the contact zone divided by a permissible specific film thickness. In the previous paper, the calculations were performed using the simplified method (Method B) that evaluates points on the path of contact. This was done for three gear sets that experienced micropitting in operation. The minimum specific film thickness for the two field cases was very high, which indicates that the gears were operating in the full elastohydrodynamic lubrication (EHL) regime. A more accurate calculation for these cases (Method A) calculates the specific film thickness across the entire contact zone. This paper applies this Method to the case study from the previous paper. The results are compared to micropitting observed in operation. Results are also compared to the results of the previous paper. Conclusions are made regarding the accuracy of both Methods compared to the field cases and relative to each other.

gearbox↗

Cone-Beam CT Localization of Internal Target Volumes for Stereotactic Body Radiotherapy of Lung Lesions

Purpose: In this study, we investigate a technique of matching internal target volumes (ITVs) in four-dimensional (4D) simulation computed tomography (CT) to the composite target volume in free-breathing on-board cone-beam (CB) CT. The technique is illustrated by using both phantom and patient cases. Methods and Materials: A dynamic phantom with a target ball simulating respiratory motion with various amplitude and cycle times was used to verify localization accuracy. The dynamic phantom was scanned using simulation CT with a phase-based retrospective sorting technique. The ITV was then determined based on 10 sets of sorted images. The size and epicenter of the ITV identified from 4D simulation CT images and the composite target volume identified from on-board CBCT images were compared to assess localization accuracy. Similarly, for two clinical cases of patients with lung cancer, ITVs defined from 4D simulation CT images and CBCT images were compared. Results: For the phantom, localization accuracy between the ITV in 4D simulation CT and the composite target volume in CBCT was within 1 mm, and ITV was within 8.7%. For patient cases, ITVs on simulation CT and CBCT were within 8.0%. Conclusion: This study shows that CBCT is a useful tool to localize ITV for targets affected by respiratory motion. Verification of the ITV from 4D simulation CT using on-board free-breathing CBCT is feasible for the target localization of lung tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-139: Dynamic Conformal Arcs Vs. VMAT for Stereotactic Lung Target Treatment Planning

Purpose: To investigate if Dynamic Conformal Arcs (DCA) can be used to achieve similar target coverage and conformality as that of using VMAT for Stereotactic Body Radiation Therapy (SBRT) for Lung cases. Methods: We retrospectively re-planned 11 patients that were treated with SBRT for lung tumors using only a single conformal arc, broken into three or four arc segments and weighted differentially in order to achieve the dosimetric constraints as outlined in RTOG 0915 protocol. These re-plans of using DCA were compared with those of using VMAT in terms of the Planning Tumor Volume (PTV) coverage goals, Maximum Dose 2 cm away (D {sub 2}cm), High Dose Spillage, Intermediate Dose Spillage, Lung volume getting 5 Gy (V{sub 5}), and number of monitor units (MU). Results: Of the 11 cases, only three DCA plans failed the D{sub 2}cm parameter, and one VMAT plan failed. None of the 11 patients failed the High Dose Spillage in either technique. For Intermediate Dose Spillage, one DCA plan failed and none failed for VMAT plans. The average V{sub 5} for DCA was 10.5 percent, with VMAT reporting 11.7 percent. The average number of MU for DCA and VMAT were 2605 and 3451, respectively. Conclusion: DCA is able to achieve very similar treatment planning goals as that of using VMAT in treating SBRT Lung tumors in most cases with simplicity. In addition, the DCA technique produces an acceptable plan with lower V{sub 5} in less MU when dose to OAR concerns are at minimum. However, DCA has shown its limitations when the target is close to multiple OAR.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-10: Improving Plan Delivery Efficiency of Intensity Modulated Proton Plans with Prioritized Optimization

Purpose: To integrate treatment delivery time into plan optimization in spot scanning intensity modulated proton therapy. Utilizing a dedicated research treatment planning system we present an optimization approach to explore the trade-off between the correlated parameters treatment time and plan quality on an astrocytoma patient case. Methods: The planning system is based on prioritized optimization, a stepwise approach of implementing clinical goals. After each optimization step, dosimetric achievements are turned into hard constraints to maintain the achieved plan quality. Prior achievements can be violated by a so-called slip-factor which allows to study possible trade-offs of conflicting goals. Plan quality is obtained in the first two steps, while the third step optimizes delivery efficiency by working on the spot weight distribution via four alternative Methods: elimination of low weighted spots (1), elimination of spots hardly contributing to PTV dose, followed by reoptimization of the resulting smaller optimization problem (2), reduction of spot weights variance within each energy layer (3), and reduction of the overall spot weight sum (4). Treatment times were calculated assuming either constant or variable beam current depending on the lowest spot weight. Results: Delivery efficiency can be improved remarkably without influencing the plan quality. Absolute time savings depend on the utilized method and facility properties. By varying slip-factor and spot reduction limits, a border of worsening quality is detectable for all methods.Deleting low weighted spots by 10% results in a noticeable decrease in minimum target dose. Further reduction results in more heterogeneous dose distributions and insufficient coverage. Option 2 showed constant plan quality for spot reductions of more than 10%. Conclusion: Including treatment time optimization as a final step into prioritized optimization allows for more efficient treatment plans by redistributing the spot patterns without compromising plan quality, which has to remain the main intent of radiotherapy treatment. The authors report grants from German Research Foundation (DFG) during the conduct of the study.

60 APPLIED LIFE SCIENCES↗

SU-F-J-156: The Feasibility of MR-Only IMRT Planning for Prostate Anatomy

Purpose: For prostate anatomy, previous investigations have shown that simulated CT (sCT) generated from MR images can be used for accurate dose computation. In this study, we demonstrate the feasibility of MR-only IMRT planning for prostate case. Methods: Regular CT (rCT) and MR images of the same patient were acquired for prostate anatomy. Regions-of-interest (ROIs) i.e. target and risk structures are delineated on the rCT. A simulated CT (sCT) is generated from the MR image using the method described by Schadewaldt N et al. Their work establishes the clinical acceptability of dose calculation results on the sCT when compared to rCT. rCT and sCT are rigidly registered to ensure proper alignment between the two images. rCT and sCT are overlaid on each other and slice-wise visual inspection confirms excellent agreement between the two images. ROIs on the rCT are copied over to sCT. Philips AutoPlanning solution is used for generating treatment plans. The same treatment technique protocol (plan parameters and clinical goals) is used to generate AutoPlan-rCT and AutoPlan-sCT respectively for rCT and and sCT. DVH comparison on ROIs and slice-wise evaluation of dose is performed between AutoPlan-rCT and AutoPlan-sCT. Delivery parameters i.e. beam and corresponding segments from the AutoPlan-sCT are copied over to rCT and dose is computed to get AutoPlan-sCT-on-rCT. Results: Plan evaluation is done based on Dose Volume Histogram (DVH) of ROIs and manual slice-wise inspection of dose distribution. Both AutoPlan-rCT and AutoPlan-sCT provide a clinically acceptable plan. Also, AutoPlan-sCT-on-rCT shows excellent agreement with AutoPlan-sCT. Conclusion: The study demonstrates that it is feasible to do IMRT planning on the simulated CT image obtained from MR image for prostate anatomy. The research is supported by Philips India Ltd.

60 APPLIED LIFE SCIENCES↗

A method to evaluate dose errors introduced by dose mapping processes for mass conserving deformations

Purpose: To present a method to evaluate the dose mapping error introduced by the dose mapping process. In addition, apply the method to evaluate the dose mapping error introduced by the 4D dose calculation process implemented in a research version of commercial treatment planning system for a patient case. Methods: The average dose accumulated in a finite volume should be unchanged when the dose delivered to one anatomic instance of that volume is mapped to a different anatomic instance--provided that the tissue deformation between the anatomic instances is mass conserving. The average dose to a finite volume on image S is defined as d{sub S}=e{sub s}/m{sub S}, where e{sub S} is the energy deposited in the mass m{sub S} contained in the volume. Since mass and energy should be conserved, when d{sub S} is mapped to an image R(d{sub S{yields}R}=d{sub R}), the mean dose mapping error is defined as {Delta}d{sub m}=|d{sub R}-d{sub S}|=|e{sub R}/m{sub R}-e{sub S}/m{sub S}|, where the e{sub R} and e{sub S} are integral doses (energy deposited), and m{sub R} and m{sub S} are the masses within the region of interest (ROI) on image R and the corresponding ROI on image S, where R and S are the two anatomic instances from the same patient. Alternatively, application of simple differential propagation yields the differential dose mapping error, {Delta}d{sub d}=|({partial_derivative}d/{partial_derivative}e)*{Delta}e+({partial_derivative}d/{partial_derivative}m)*{Delta}m|=|((e{sub S}-e{sub R})/m{sub R})-((m{sub S}-m{sub R})/m{sub R}{sup 2})*e{sub R}|={alpha}|d{sub R}-d{sub S}| with {alpha}=m{sub S}/m{sub R}. A 4D treatment plan on a ten-phase 4D-CT lung patient is used to demonstrate the dose mapping error evaluations for a patient case, in which the accumulated dose, D{sub R}={Sigma}{sub S=0}{sup 9}d{sub S{yields}R}, and associated error values ({Delta}D{sub m} and {Delta}D{sub d}) are calculated for a uniformly spaced set of ROIs. Results: For the single sample patient dose distribution, the average accumulated differential dose mapping error is 4.3%, the average absolute differential dose mapping error is 10.8%, and the average accumulated mean dose mapping error is 5.0%. Accumulated differential dose mapping errors within the gross tumor volume (GTV) and planning target volume (PTV) are lower, 0.73% and 2.33%, respectively. Conclusions: A method has been presented to evaluate the dose mapping error introduced by the dose mapping process. This method has been applied to evaluate the 4D dose calculation process implemented in a commercial treatment planning system. The method could potentially be developed as a fully-automatic QA method in image guided adaptive radiation therapy (IGART).

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-498: Energy Minimization and Dose-Volume Inverse Optimization in Prostate Cancer

Purpose: To compare dose-volume (DVH) and energy minimization-based (EM) optimization for prostate cancer cases. Methods: A dozen of prostate plans were retrospectively studied. For each case two IMRT plans were generated, one with DVH and the other with EM objective cost function. Those different objective functions were used only for the organs at risk (OARs), while target objectives were achieved through DVH cost functions. The plans used the same beam angles, maximum number of segments per plan, minimum segment area and MUs per segment. Both plans were normalized such that 95% of the PTV was covered by the same prescription dose. After prescription was achieved, doses to the OARs were iteratively lowered until the standard deviation of the dose across the PTV was ~3.5%. Plan quality was evaluated by several dose indices (DIs). A DI represents the dose delivered to certain volume of a structure. Tallied DIs were for rectum and bladder 10%, 40%, 60% volumes, and 1% volumes of the femoral heads as surrogate for maximum doses. Statistical significance in the differences among DIs was quantified with two-tailed paired t-tests. Results: On average EM plans performed better than DVH plans. Statistically significant dose reduction in rectum DI10, DI40, and DI60, were 2.6%, 25.7%, and 35.9%, respectively. For bladder DI10, DI40, and DI60 the differences were 1.1%, 20.8%, and 29.7%. Left and right femoral head DI1s were better by 33.8% and 27.8% in EM plans. The quoted dose reduction is with respect to EM absolute doses for the DIs. Conclusion: The performance of EM optimization with respect to DVH optimization is patient and DI dependent. While in some cases specific DIs were better with DVH optimization, on average the energy minimization allows better (ranging from 1% to ~40%) OAR sparing than DVH optimization. NIH-NCI.

60 APPLIED LIFE SCIENCES↗

Myths and realities: Defining re-engineering for a large organization

This paper describes the background and results of three studies concerning software reverse engineering, re-engineering, and reuse (R3) hosted by the Internal Revenue Service in 1991 and 1992. The situation at the Internal Revenue--aging, piecemeal computer systems and outdated technology maintained by a large staff--is familiar to many institutions, especially among management information systems. The IRS is distinctive for the sheer magnitude and diversity of its problems; the country's tax records are processed using assembly language and COBOL and spread across tape and network DBMS files. How do we proceed with replacing legacy systems? The three software re-engineering studies looked at methods, CASE tool support, and performed a prototype project using re-engineering methods and tools. During the course of these projects, we discovered critical issues broader than the mechanical definitions of methods and tool technology.

Yin, Sandra↗

Finite-element analysis of top-casing electric source method for imaging hydraulically active fracture zones

Imaging hydraulically active fracture zones (HAFZ) is of paramount importance to subsurface resource extraction, geologic storage, and hazardous waste disposal. We have developed advanced 3D finite-element (FE) electrical imaging algorithms for HAFZ in the presence of a steel-cased well. The algorithms use tetrahedral FE meshes in the simulation domain and coarse rectangular finite-difference meshes in the imaging domain. This heterogeneous dual-mesh approach is well suited to modeling the multiscale earth model due to steel-cased wells. We find that the algorithms accurately and efficiently simulate surface electric field measurements over a 3D HAFZ at depth when one end point of a surface electric source is connected to a wellhead. For brevity, this configuration is called the top-casing electric source method. By replacing a hollow cased well with a solid prism, we improve our computational efficiency without affecting the solution accuracy. The sensitivity of the top-casing source method to HAFZ highly depends on the continuity of a steel-cased well because it makes currents preferentially flow to HAFZ. The sensitivity also depends on conductivity structures around the well because they control current leaking from the steel-cased well. We find that the method can image a localized HAFZ and detect changes in its width and height. Here, the imaging results are improved when a volume of the imaging domain is constrained from geomechanical perspectives. A primary advantage of the method is the fact that the sources and receivers are placed on the surface, thus not interrupting the well operation.

3D↗

SU-F-T-97: Outlier Identification in Radiation Therapy Knowledge Modeling

Purpose: To investigate the impact of outliers on knowledge modeling in radiation therapy, and develop a systematic workflow for identifying and analyzing geometric and dosimetric outliers using pelvic cases. Methods: Four groups (G1-G4) of pelvic plans were included: G1 (37 prostate cases), G2 (37 prostate plus lymph node cases), and G3 (37 prostate bed cases) are all clinical IMRT cases. G4 are 10 plans outside G1 re-planned with dynamic-arc to simulate dosimetric outliers. The workflow involves 2 steps: 1. identify geometric outliers, assess impact and clean up; 2. identify dosimetric outliers, assess impact and clean up.1. A baseline model was trained with all G1 cases. G2/G3 cases were then individually added to the baseline model as geometric outliers. The impact on the model was assessed by comparing leverage statistic of inliers (G1) and outliers (G2/G3). Receiver-operating-characteristics (ROC) analysis was performed to determine optimal threshold. 2. A separate baseline model was trained with 32 G1 cases. Each G4 case (dosimetric outliers) was then progressively added to perturb this model. DVH predictions were performed using these perturbed models for remaining 5 G1 cases. Normal tissue complication probability (NTCP) calculated from predicted DVH were used to evaluate dosimetric outliers’ impact. Results: The leverage of inliers and outliers was significantly different. The Area-Under-Curve (AUC) for differentiating G2 from G1 was 0.94 (threshold: 0.22) for bladder; and 0.80 (threshold: 0.10) for rectum. For differentiating G3 from G1, the AUC (threshold) was 0.68 (0.09) for bladder, 0.76 (0.08) for rectum. Significant increase in NTCP started from models with 4 dosimetric outliers for bladder (p<0.05), and with only 1 dosimetric outlier for rectum (p<0.05). Conclusion: We established a systematic workflow for identifying and analyzing geometric and dosimetric outliers, and investigated statistical metrics for detecting. Results validated the necessity for outlier detection and clean-up to enhance model quality in clinical practice. Research Grant: Varian master research grant.

60 APPLIED LIFE SCIENCES↗

Energy Northwest – Horn Rapids Solar and Storage: A Techno-economic Assessment

In 2017, as part of the second round of funding from the Washington State Clean Energy Fund, the Washington State Department of Commerce granted up to $\$3$ million in matching funds to develop an estimated $6.5 million project that deployed a 4-MW, 20-acre solar generating array of photovoltaic (PV) panels coupled with a 1 MW/4 MWh (nameplate capacity) lithium-iron-phosphate battery energy storage system (BESS) in Richland, Washington. The combination of PV and BESS will provide a predictable, renewable generating source and will also serve as a training ground for solar and battery technicians throughout the nation. This report documents the techno-economic assessment of the integrated system, including the definition of use cases and applications, collection and preparation of data and input parameters, development of modeling and optimization methods, case studies, and analysis results.

14 SOLAR ENERGY↗

CLimate Impact: Determining Etiology thRough pAthways (CLDERA)

Climate impacts have broad economic, health, political, and national security ramifications. Societally relevant impacts are typically farther downstream, are the product of multiple interacting processes, and can arise over small regions and timeframes because their sources are short-term and localized. Short-term forcings (as can be seen in volcanic eruptions, climatic tipping points (e.g., the collapse of rainforests or the disappearance of sea ice), or in increasingly plausible climate interventions) fundamentally possess low signal-to-noise and could benefit from accounting for the multiple conditional processes through which a downstream impact arises. Under the Grand Challenge LDRD CLDERA (CLimate impacts: Discovering Etiology thRough pAthways), we have developed tools to enable downstream impact attribution from geographically and temporally localized source forcings in the climate. CLDERA developed methods that can distinguish how a localized source drives the climate system to respond with particular impacts. The how is embodied in pathways – the spatio-temporally evolving chain of physical processes that connects a source to a series of increasingly distant impacts. Novel analytic methods in pursuit of downstream impact attribution were developed and demonstrated on simulations and observations of the 1991 eruption of Mt. Pinatubo in the Philippines. As described within this report we have • developed stratospheric expertise and aerosol modeling capabilities in E3SM, • created original methods to detect and model pathways from source-to-impact, and • advanced climate attribution through novel methods, cases, and approaches. Further, CLDERA developed a tiered verification process consisting of controlled datasets to prototype, verify, and refine the original method development. CLDERA increased Sandia’s footprint in the climate analytics community and developed new climate collaborations whilst also creating a cadre of climate analysts at Sandia. The products from CLDERA have been extensive with a total of 9 journal articles published, 12 articles submitted and under review, and an additional 8 articles in preparation. We have produced 1750 simulated years and developed 9 code-bases. This report details these accomplishments and serves as a summary of the work completed during the CLDERA Grand Challenge.

54 ENVIRONMENTAL SCIENCES↗

A novel method to construct stationary solutions of the Vlasov-Maxwell system: The relativistic case

A method to derive stationary solutions of the relativistic Vlasov-Maxwell system is explored. In the nonrelativistic case, a method using the Hermite polynomial series to describe the deviation from the Maxwell-Boltzmann distribution is found to be successful in deriving a few stationary solutions, including a two-dimensional one. Instead of the Hermite polynomial series, two special orthogonal polynomial series, which are appropriate to expand the deviation from the Maxwell-Juettner distribution, are introduced in this paper. By applying this method, a new two-dimensional equilibrium is derived, which may provide an initial setup for investigations of three-dimensional relativistic collisionless reconnection of magnetic fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Proton Beam Therapy and Accountable Care: The Challenges Ahead

Purpose: Proton beam therapy (PBT) centers have drawn increasing public scrutiny for their high cost. The behavior of such facilities is likely to change under the Affordable Care Act. We modeled how accountable care reform may affect the financial standing of PBT centers and their incentives to treat complex patient cases. Methods and Materials: We used operational data and publicly listed Medicare rates to model the relationship between financial metrics for PBT center performance and case mix (defined as the percentage of complex cases, such as pediatric central nervous system tumors). Financial metrics included total daily revenues and debt coverage (daily revenues − daily debt payments). Fee-for-service (FFS) and accountable care (ACO) reimbursement scenarios were modeled. Sensitivity analyses were performed around the room time required to treat noncomplex cases: simple (30 minutes), prostate (24 minutes), and short prostate (15 minutes). Sensitivity analyses were also performed for total machine operating time (14, 16, and 18 h/d). Results: Reimbursement under ACOs could reduce daily revenues in PBT centers by up to 32%. The incremental revenue gained by replacing 1 complex case with noncomplex cases was lowest for simple cases and highest for short prostate cases. ACO rates reduced this incremental incentive by 53.2% for simple cases and 41.7% for short prostate cases. To cover daily debt payments after ACO rates were imposed, 26% fewer complex patients were allowable at varying capital costs and interest rates. Only facilities with total machine operating times of 18 hours per day would cover debt payments in all scenarios. Conclusions: Debt-financed PBT centers will face steep challenges to remain financially viable after ACO implementation. Paradoxically, reduced reimbursement for noncomplex cases will require PBT centers to treat more such cases over cases for which PBT has demonstrated superior outcomes. Relative losses will be highest for those facilities focused primarily on treating noncomplex cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Terrestrial case studies of ilmenite exploration and lunar implications

The Space Exploration Initiative (SEI) includes space resource utilization as one of the four architectures to achieve U.S. goals in space. Space resource utilization will make use of lunar resources to support long term activities on the lunar surface. Lunar ilmenite and regolith are two of the materials that can be mined and processed for lunar oxygen production. During this investigation, several sources were reviewed to assess terrestrial exploration methods used for locating ilmenite resources. These sources included published reports on terrestrial ilmenite exploration methods, analytical methods, case histories, chemical and physical properties, and associations with other minerals. Using a terrestrial analog and considering the differences between terrestrial and lunar environmental conditions, rocks, and minerals, exploration methods and analytical instruments can be recommended for a lunar orbiter and lander for assessing lunar resources. Twelve terrestrial case histories were reviewed to gain insight into ilmenite exploration on the Moon. All exploration case histories follow the same pattern. They begin with a model, use remote geophysical techniques, define regional sampling sites from the model and geophysics, narrow down the area of exploration based on the preceding work, collect more samples and cores, and perform laboratory analyses of samples. An important part of this process is the collection of samples to determine the correctness of the model. Surface and core samples are collected in areas expected to contain both high and low concentration of the commodity to test the model. After samples are analyzed and the area of mineralization is defined, reserves are calculated to determine the cost/benefit ratio, the necessary capacity of the processing plant, and the life of the mine. The exploration methods used for locating terrestrial ilmenite resources are reviewed with respect to the petrology, chemistry, and mineral associations of the terrestrial and lunar environments.

Feldman, S. C.↗

Combining Emergent Constraints for Climate Sensitivity

A method is proposed for combining information from several emergent constraints into a probabilistic estimate for a climate sensitivity proxy Y such as equilibrium climate sensitivity (ECS). The method is based on fitting a multivariate Gaussian PDF for Y and the emergent constraints using an ensemble of global climate models (GCMs); it can be viewed as a form of multiple linear regression of Y on the constraints. The method accounts for uncertainties in sampling this multidimensional PDF with a small number of models, for observational uncertainties in the constraints, and for overconfidence about the correlation of the constraints with the climate sensitivity. Its general form (Method C) accounts for correlations between the constraints. Method C becomes less robust when some constraints are too strongly related to each other; this can be mitigated using regularization approaches such as ridge regression. An illuminating special case, Method U, neglects any correlations between constraints except through their mutual relationship to the climate proxy; it is more robust to small GCM sample size and is appealingly interpretable. These methods are applied to ECS and the climate feedback parameter using a previously published set of 11 possible emergent constraints derived from climate models in the Coupled Model Intercomparison Project (CMIP). The ±2σ posterior range of ECS for Method C with no overconfidence adjustment is 4.3 ± 0.7 K. For Method U with a large overconfidence adjustment, it is 4.0 ± 1.3 K. This study adds confidence to past findings that most constraints predict higher climate sensitivity than the CMIP mean.

54 ENVIRONMENTAL SCIENCES↗

Comparative Analysis of Soft-Error Detection Strategies: A Case Study with Iterative Methods

Undetected soft errors caused by transient bit flips can lead to silent data corruption (SDC), an undesirable outcome where invalid results pass for valid ones. This has motivated the design of soft error detectors to minimize SDCs. However, the detectors have been studied under different contexts, making comparative evaluation difficult. In this paper, we present the first comprehensive evaluation of four online soft error detection techniques in detecting the adverse impact of soft errors on iterative methods. We observe that, across five iterative methods, the detectors studied achieve high but not perfect detection rates. To understand the potential for improved detection, we evaluate a machine-learning based detector that takes as features that are the runtime features observed by the individual detectors to arrive at their conclusions. Our evaluation demonstrates improved but still far from perfect detection accuracy for the machine learning based detectors. This extensive evaluation demonstrates the need for designing error detectors to handle the evolutionary behavior exhibited by iterative solvers.

Silent data corruption, Soft error detection, Iter↗

Exploring the potential of context-sensitive CADe in screening mammography

Purpose: Conventional computer-assisted detection (CADe) systems in screening mammography provide the same decision support to all users. The aim of this study was to investigate the potential of a context-sensitive CADe system which provides decision support guided by each user's focus of attention during visual search and reporting patterns for a specific case. Methods: An observer study for the detection of malignant masses in screening mammograms was conducted in which six radiologists evaluated 20 mammograms while wearing an eye-tracking device. Eye-position data and diagnostic decisions were collected for each radiologist and case they reviewed. These cases were subsequently analyzed with an in-house knowledge-based CADe system using two different modes: Conventional mode with a globally fixed decision threshold and context-sensitive mode with a location-variable decision threshold based on the radiologists' eye dwelling data and reporting information. Results: The CADe system operating in conventional mode had 85.7% per-image malignant mass sensitivity at 3.15 false positives per image (FPsI). The same system operating in context-sensitive mode provided personalized decision support at 85.7%-100% sensitivity and 0.35-0.40 FPsI to all six radiologists. Furthermore, context-sensitive CADe system could improve the radiologists' sensitivity and reduce their performance gap more effectively than conventional CADe. Conclusions: Context-sensitive CADe support shows promise in delineating and reducing the radiologists' perceptual and cognitive errors in the diagnostic interpretation of screening mammograms more effectively than conventional CADe.

60 APPLIED LIFE SCIENCES↗