SEARCH · Engineering Papers
Results for “CAPILLARIES”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Influence of injection strategies on local capillary trapping during geological carbon sequestration in saline aquifers
Not Available
Enriched Galerkin methods for two-phase flow in porous media with capillary pressure
Not Available
Design and performance evaluation of a 1000-year evapotranspiration-capillary surface barrier
Not Available
Nanopore confinement effects on phase behavior and capillary pressure in a Wolfcamp shale reservoir
Not Available
Magneto-capillary dynamics of amphiphilic Janus particles at curved liquid interfaces
Static homogeneous fields drive motions of magnetic particles along curved liquid interfaces.
Pore saturation model for capillary imbibition and drainage pressures
Explore the source record for details and available documents.
Capillary pressure saturation relations supercritical CO2 and brine in sand: High-pressure Pc(Sw) controller/meter measurements and capillary scaling predictions
Explore the source record for details and available documents.
Pore-scale study of capillary trapping mechanism during CO2 injection in geological formations
Geological sequestration of CO{sub 2} gas emerged as a promising solution for reducing amount of green house gases in atmosphere. A number of continuum scale models are available to describe the transport phenomena of CO{sub 2} sequestration. These models rely heavily on a phenomenological description of subsurface transport phenomena and the predictions can be highly uncertain. Pore-scale models provide a better understanding of fluid displacement processes, nonetheless such models are rare. In this work we use a Smoothed Particle Hydrodynamics (SPH) model to study pore-scale displacement and capillary trapping mechanisms of super-critical CO{sub 2} in the subsurface. Simulations are carried out to investigate the effects of gravitational, viscous, and capillary forces in terms of Gravity, Capillary, and Bond numbers. Contrary to the other published continuum scale investigations, we found that not only Gravity number but also Capillary number plays an important role on the fate of injected CO{sub 2}. For large Gravity numbers (on the order of 10), most of the injected CO{sub 2} reaches the cap-rock due to gravity segregation. A significant portion of CO{sub 2} gets trapped by capillary forces when Gravity number is small (on the order of 0.1). When Gravity number is moderately high (on the order of 1), trapping patterns are heavily dependent on Capillary number. If Capillary number is very small (less than 0.001), then capillary forces dominate the buoyancy forces and a significant fraction of injected CO{sub 2} is trapped by the capillary forces. Conversely, if Capillary number is high (higher than 0.001), capillary trapping is relatively small since buoyancy dominates the capillary forces. In addition, our simulations reveal different types of capillary trapping and flow displacement mechanisms during and after injection. In gravity dominated cases leave behind was the widespread trapping mechanism. Division was the primary trapping mechanism in viscous dominated cases. In capillary dominated cases, snap-off of the CO{sub 2} plume is the most commonly observed displacement mechanism. Large CO{sub 2} blobs are created due to coalescence mechanism.
The impact of capillary heterogeneity on CO 2 flow and trapping across scales
Capillary heterogeneity has been identified over the last decade as a key control on subsurface CO 2 flow behavior during geological CO 2 sequestration. These heterogeneities can be formed in all sedimentary rocks, ranging from slight variations in the sand grain sizes to extensive sequences of interbedded sands, shales, and limestones. Capillary heterogeneity has been largely, although not entirely, overlooked in subsurface flow modeling because it is assumed to only directly influence fluid redistribution over scales of centimeters to meters. However, even small-scale fluid movements can result in dramatic impacts on the mobility and trapping of the CO 2 over kilometers. Therefore, neglecting capillary heterogeneity at multiple scales could potentially lead to errors in modeling and predicting field-scale plume migration. In this review paper, we aim to provide a consistent overview to (1) establish that capillary heterogeneity can have a major impact on CO 2 plume migration, (2) establish the respective length scales at which capillary heterogeneity matters, and (3) provide guidance for numerical modeling. This review covers pertinent literature and extracts key observations from the core to the field scales. Experimental studies have shown that millimeter-decimeter scale capillary heterogeneity can cause the so-called capillary heterogeneity trapping in addition to pore-scale residual trapping. Even at such a small scale, capillary heterogeneity can already lead to complex upscaled constitutive relationships, such as flow-rate dependent and anisotropic relative permeability, which affects field-scale CO 2 migration even when field-scale heterogeneities are present. Under gravity-dominated flow regimes, centimeter-meter scale capillary heterogeneity can entrap a significant amount of CO 2 at field scale, not just after imbibition but also during drainage. In certain cases, the presence of capillary heterogeneity can even completely stop the vertical movement of the CO 2 plume, hence greatly reducing leakage risks. At meter-kilometer scale, the influence of capillary heterogeneity is more pronounced and can hinder or redirect CO 2 migration in both lateral and vertical directions. The impact of capillary heterogeneity across multiple spatial scales poses a great challenge in modeling CO 2 migration at field scale, because it is practically impossible to build a field-scale earth model with grid blocks at millimeter scale. We recommend a hierarchical modeling approach to address this challenge. At field scale, earth models are built to capture geological features and heterogeneities in high but still practical grid resolutions. For each facies or rock type of the field-scale model, high- resolution meter-scale “conceptual” models are built with millimeter-scale grid blocks to capture representative fine-scale bedding geometries and heterogeneities in various environments of deposition, bridging the gap from subcore scale to the size of a field-scale simulation grid block. Upscaling is then used to preserve the smaller-scale flow dynamics of various rock types in field-scale simulations. Here, future work is needed to (1) refine, improve, and validate the hierarchical modeling approach; (2) build libraries of fine-scale bedding models for facies in various environments of deposition; (3) quantify multiscale capillary heterogeneity effects under subsurface uncertainties; (4) gain learning from different storage formations; and (5) establish best practices that balance accuracy and computational speed.
Transport mechanism of MeV protons in tapered glass capillaries
To investigate the transport mechanism of MeV protons in tapered glass capillaries, spatially resolved energy spectra were measured for proton microbeams focused by 20-{mu}m-outlet capillaries having various taper angles. Three-dimensional Monte Carlo (MC) simulations were also performed to support the experiments and trace each particle in the capillary in more detail. The dependence of the proton energy distribution on the outgoing angle proved that the capillary-focused proton beam consists of two different components, protons traveling straight through the capillary without colliding with the capillary wall and protons scattered by the capillary inner wall. Moreover, the focusing effect of the tapered glass capillary was found to be mainly due to the scattered beam component. The MC simulations well reproduced the experimental results and showed that beam focusing ratios of 1.6-2.4 are possible with capillaries having a convex inner wall. The flight distance of the scattered proton in the capillary glass body was found to play an important role in determining transport efficiency of the protons through the capillary.
Effect of Dimensional Changes on Plasma Characteristics in Electrothermal Capillary Discharges for Optimized Performance in Fusion Pellet Injection
Geometrical changes in capillary discharges influence the plasma properties and can control exit parameters to certain desired values. For a fixed capillary radius of 2 mm and a 72-μs 43.9-kA peak discharge current, the plasma temperature is about 2.7 eV for different capillary lengths due to the constant input energy, while the number densities tend to saturate for capillary lengths greater than 12 cm. The electrical conductivity reaches 4.02 × 104 Ω{sup −1} m{sup −1} and then tends to saturate for 9-cm capillary length. The maximum bulk velocity at the capillary exit slightly increases with the increase in the capillary length from 6.15 to 6.26 km/s for lengths below 18 cm and decreases to 5.88 km/s for longer capillaries due to the higher amount of ablated mass and increased drag forces. For a 9-cm length with the same 72-μs 43.9-kA peak discharge current, the increase in the capillary radius reduces the energy density, which in turn reduces the total ablate mass, plasma density, electrical conductivity, and exit pressure. It is shown that the plasma temperature decreases from 4.6 to 2.1 eV by increasing the capillary radius and radiant heat flux also drops from 463 to 18.1 GW/m{sup 2}. The exit bulk velocity drops from 8.7 to 5.3 km/s as the radius increases from 0.5 to 3.6 mm, respectively. The design features of a capillary discharge can be adjusted for the radius and length, to produce specific plasma parameters for desired applications. Scaling laws relating exit peak plasma parameters to radius and length are obtained to facilitate quick estimate of plasma parameters. The validation of this model has been confirmed by confronting with experimental measurements.
Influence of local capillary trapping on containment system effectiveness
Immobilization of CO 2 injected into deep subsurface storage reservoirs is a critical component of risk assessment for geologic CO 2 storage (GCS). Local capillary trapping (LCT) is a recently established mode of immobilization that arises when CO 2 migrates due to buoyancy through heterogeneous storage reservoirs. This project sought to assess the amount and extent of LCT expected in storage formations under a range of injection conditions, and to confirm the persistence of LCT if the seal overlying the reservoir were to lose its integrity. Numerical simulation using commercial reservoir simulation software was conducted to assess the influence of injection. Laboratory experiments, modeling and numerical simulation were conducted to assess the effect of compromised seal integrity. Bench-scale (0.6 m by 0.6 m by 0.03 m) experiments with surrogate fluids provided the first empirical confirmation of the key concepts underlying LCT: accumulation of buoyant nonwetting phase at above residual saturations beneath capillary barriers in a variety of structures, which remains immobile under normal capillary pressure gradients. Immobilization of above-residual saturations is a critical distinction between LCT and the more familiar “residual saturation trapping.” To estimate the possible extent of LCT in a storage reservoir an algorithm was developed to identify all potential local traps, given the spatial distribution of capillary entry pressure in the reservoir. The algorithm assumes that the driving force for CO 2 migration can be represented as a single value of “critical capillary entry pressure” P c,entry crit , such that cells with capillary entry pressure greater/less than P c,entry crit act as barriers/potential traps during CO 2 migration. At intermediate values of P c,entry crit , the barrier regions become more laterally extensive in the reservoir, approaching a percolation threshold while non-barrier regions remain numerous. The maximum possible extent of LCT thus occurs at P c,entry crit near this threshold. Testing predictions of this simple algorithm against full-physics simulations of buoyancy-driven CO 2 migration support the concept of critical capillary entry pressure. However, further research is needed to determine whether a single value of critical capillary entry pressure always applies and how that value can be determined a priori. Simulations of injection into high-resolution (cells 0.3 m on a side) 2D and 3D heterogeneous domains show two characteristic behaviors. At small gravity numbers (vertical flow velocity much less than horizontal flow velocity) the CO 2 fills local traps as well as regions that would act as local barriers if CO 2 were moving only due to buoyancy. When injection ceases, the CO 2 migrates vertically to establish large saturations within local traps and residual saturation elsewhere. At large gravity numbers, the CO 2 invades a smaller portion of the perforated interval. Within this smaller swept zone the local barriers are not invaded, but local traps are filled to large saturation during injection and remain during post-injection gravity-driven migration. The small gravity number behavior is expected in the region within 100 m of a vertical injection well at anticipated rates of injection for commercial GCS. Simulations of leakage scenarios (through-going region of large permeability imposed in overlying seal) indicate that LCT persists (i.e. CO 2 remains held in a large fraction of the local iv traps) and the persistence is independent of injection rate during storage. Simulations of leakage for the limiting case of CO 2 migrating vertically from an areally extensive emplacement in the lower portion of a reservoir showed similar strong persistence of LCT. This research has two broad implications for GCS. The first is that LCT can retain a significant fraction of the CO 2 stored in a reservoir – above and beyond the residual saturation -- if the overlying seal were to fail. Thus frameworks for risk assessment should be extended to account for LCT. The second implication is that compared to pressure driven flow in reservoirs, CO 2 migration and trapping behave in a qualitatively different manner in heterogeneous reservoirs when buoyancy is the dominant driving force for flow. Thus simulations of GCS that neglect capillary heterogeneity will fail to capture important features of the CO 2 plume. While commercial reservoir simulation software can account for fine scale capillary heterogeneity, it has not been designed to work efficiently with such domains, and no simulators can handle fine-scale resolution throughout the reservoir. A possible way to upscale the migration and trapping is to apply an “effective residual saturation” to coarse-scale grids. While the extent of overall immobilization can be correlated in this way, all coarser grids failed to capture the distance traveled by the migrating CO 2 for large gravity number. Thus it remains unclear how best to account for LCT in the routine simulation work-flow that will be needed for large-scale GCS. Alternatives meriting investigation include streamline methods, reduced-physics proxies (e.g. particle tracking), and biased invasion percolation algorithms, which are based on precisely the capillary heterogeneity essential for LCT.
DNA Sequencing Using capillary Electrophoresis
The overall goal of this program was to develop capillary electrophoresis as the tool to be used to sequence for the first time the Human Genome. Our program was part of the Human Genome Project. In this work, we were highly successful and the replaceable polymer we developed, linear polyacrylamide, was used by the DOE sequencing lab in California to sequence a significant portion of the human genome using the MegaBase multiple capillary array electrophoresis instrument. In this final report, we summarize our efforts and success. We began our work by separating by capillary electrophoresis double strand oligonucleotides using cross-linked polyacrylamide gels in fused silica capillaries. This work showed the potential of the methodology. However, preparation of such cross-linked gel capillaries was difficult with poor reproducibility, and even more important, the columns were not very stable. We improved stability by using non-cross linked linear polyacrylamide. Here, the entangled linear chains could move when osmotic pressure (e.g. sample injection) was imposed on the polymer matrix. This relaxation of the polymer dissipated the stress in the column. Our next advance was to use significantly lower concentrations of the linear polyacrylamide that the polymer could be automatically blown out after each run and replaced with fresh linear polymer solution. In this way, a new column was available for each analytical run. Finally, while testing many linear polymers, we selected linear polyacrylamide as the best matrix as it was the most hydrophilic polymer available. Under our DOE program, we demonstrated initially the success of the linear polyacrylamide to separate double strand DNA. We note that the method is used even today to assay purity of double stranded DNA fragments. Our focus, of course, was on the separation of single stranded DNA for sequencing purposes. In one paper, we demonstrated the success of our approach in sequencing up to 500 bases. Other application papers of sequencing up to this level were also published in the mid 1990's. A major interest of the sequencing community has always been read length. The longer the sequence read per run the more efficient the process as well as the ability to read repeat sequences. We therefore devoted a great deal of time to studying the factors influencing read length in capillary electrophoresis, including polymer type and molecule weight, capillary column temperature, applied electric field, etc. In our initial optimization, we were able to demonstrate, for the first time, the sequencing of over 1000 bases with 90% accuracy. The run required 80 minutes for separation. Sequencing of 1000 bases per column was next demonstrated on a multiple capillary instrument. Our studies revealed that linear polyacrylamide produced the longest read lengths because the hydrophilic single strand DNA had minimal interaction with the very hydrophilic linear polyacrylamide. Any interaction of the DNA with the polymer would lead to broader peaks and lower read length. Another important parameter was the molecular weight of the linear chains. High molecular weight (> 1 MDA) was important to allow the long single strand DNA to reptate through the entangled polymer matrix. In an important paper, we showed an inverse emulsion method to prepare reproducibility linear polyacrylamide polymer with an average MWT of 9MDa. This approach was used in the polymer for sequencing the human genome. Another critical factor in the successful use of capillary electrophoresis for sequencing was the sample preparation method. In the Sanger sequencing reaction, high concentration of salts and dideoxynucleotide remained. Since the sample was introduced to the capillary column by electrokinetic injection, these salt ions would be favorably injected into the column over the sequencing fragments, thus reducing the signal for longer fragments and hence reading read length. In two papers, we examined the role of individual components from the sequencing reaction and then developed a protocol to reduce the deleterious salts. We demonstrated a robust method for achieving long read length DNA sequencing. Continuing our advances, we next demonstrated the achievement of over 1000 bases in less than one hour with a base calling accuracy of between 98 and 99%. In this work, we implemented energy transfer dyes which allowed for cleaner differentiation of the 4 dye labeled terminal nucleotides. In addition, we developed improved base calling software to help read sequencing when the separation was only minimal as occurs at long read lengths. Another critical parameter we studied was column temperature. We demonstrated that read lengths improved as the column temperature was increased from room temperature to 60 C or 70 C. The higher temperature relaxed the DNA chains under the influence of the high electric field.
Impact of Pressure-Dependent Interfacial Tension and Contact Angle on Capillary Heterogeneity Trapping of CO2 in Storage Aquifers
Summary Carbon dioxide (CO2) capillary trapping increases the total amount of CO2 that can be effectively immobilized in storage aquifers. This trapping, manifesting itself as accumulated CO2 columns at a continuum scale, is because of capillary threshold effects that occur below low-permeability barriers. Considering that capillary pressure is dictated by heterogeneous pore throat size, the trapped CO2 column height and associated CO2 saturation will vary spatially within a storage aquifer. This variation will be influenced by two pressure-dependent interfacial parameters—CO2/brine interfacial tension (IFT) and CO2/brine/rock contact angle. Our objective is to understand how the pressure dependence of these two parameters affects the heterogeneity of capillary trapped CO2 at a continuum scale. Our conceptual model is a 1D two-zone system with the upper zone being a flow barrier (low permeability) and the lower zone being a flow path (high permeability). The inputs to this model include microfacies-dependent capillary pressure vs. saturation curves and permeability values. The input capillary pressure curves were collected in the literature that represents carbonate microfacies (e.g., dolograinstone) in a prevalent formation in the Permian Basin. We then used the Leverett j-function to scale the capillary pressure curve for the two zones that are assigned with the same or different microfacies. During scaling, we considered the influence of pressure on both the IFT and contact angle of CO2/brine/dolomite systems. We varied the zone permeability contrast ratio from 2 to 50. We then assumed capillary gravity equilibriums and calculated the CO2 saturation buildup corresponding to various trapped CO2 column heights. The CO2 saturation buildup is defined as the CO2 saturation in the lower layer minus that in the upper one. We found that the saturation buildup can be doubled when varying pressure in a storage aquifer, after considering pressure-dependent IFT and contact angles. Thus, assuming these two parameters to be constant across such aquifers would cause large errors in the quantification of capillary trapping of CO2. The whole study demonstrates the importance of considering pressure-dependent interfacial properties in predicting the vertical distribution of capillary trapped CO2. It has important implications in developing a better understanding of leakage risks and consequent storage safety.
Fatigue Performance of Ti-6Al-4V Additively Manufactured Specimens with Integrated Capillaries of an Embedded Structural Health Monitoring System
Additive manufacturing (AM) of metals offers new possibilities for the production of complex structures. Up to now, investigations on the mechanical response of AM metallic parts show a significant spread and unexpected failures cannot be excluded. In this work, we focus on the detection of fatigue cracks through the integration of a Structural Health Monitoring (SHM) system in Ti-6Al-4V specimens. The working principle of the presented system is based on the integration of small capillaries that are capable of detecting fatigue cracks. Four-point bending fatigue tests have been performed on Ti-6Al-4V specimens with integrated capillaries and compared to the reference specimenswithout capillaries. Specimens were produced by conventional subtractive manufacturing of wrought material and AM, using the laser based Directed Energy Deposition (DED) process. In this study, we investigated the effect of the presence of the capillary on the fatigue strength and fatigue initiation location. Finite element (FEM) simulations were performed to validate the experimental test results. The presence of a drilled capillary in the specimens did not alter the fatigue initiation location. However, the laser based DED production process introduced roughness on the capillary surface that altered the fatigue initiation location to the capillary surface. The fatigue performance was greatly reduced when considering a printed capillary. It is concluded that the surface quality of the integrated capillary is of primary importance in order not to influence the structural integrity of the component to be monitored.