Accelerating rate calorimetry: A new technique for safety studies in lithium systems

The role of exothermic reactions in battery test modes is discussed. The exothermic reactions are characterized with respect to their time-temperature and time-pressure behavior. Reactions occuring for any major exotherm were examined. The accelerating rate calorimetry methods was developed to study lithium cells susceptibility to thermal runaway reactions following certain abuse modes such as forced discharge into reversal and charging.

Ebner, W. B.

Cure kinetics of epoxy matrix resin by differential scanning calorimetry

A study was made on the cure kinetics of an epoxy neat-resin (Narmco 5208) using Differential Scanning Calorimetry (DSC). Two interrelated analytical methods were applied to dynamic DSC data for evaluating the kinetic parameters, such as activation energy, E, the order of reaction, n, and the total heat of polymerization (or crosslinking), delta H sub t. The first method was proposed by Ellerstein (1968), and uses a thorough differential-integral analysis of a single DSC curve to evaluate the kinetic parameters. The second method was proposed by Kissinger (1957), and uses multiple DSC curves obtained at various heating rates to evaluate E regardless of n. Kinetic analysis of Narmco 5208 epoxy resin showed that the reaction order, n, is substantially affected by the rate of heating; i.e., n is approximately 2 at slow scan rates but is reduced to 1.5 at higher scan rates. The activation energy, E, is not affected by the scan rate, and the average value of E is 25.6 + or - 1.8 kcal/mole.

Cizmecioglu, M.

Accurate Measurement of Heat Capacity by Differential Scanning Calorimetry

Experience with high quality heat capacity measurement by differential scanning calorimetry is summarized and illustrated, pointing out three major causes of error: (1) incompatible thermal histories of the sample, reference and blank runs; (2) unstable initial and final isotherms; (3) incompatible differences between initial and final isotherm amplitudes for sample, reference and blank runs. Considering these problems, it is shown for the case of polyoxymethylene that accuracies in heat capacity of 0.1 percent may be possible.

Source record

Applications of high pressure differential scanning calorimetry to aviation fuel thermal stability research

High pressure differential scanning calorimetry (DSC) was studied as an alternate method for performing high temperature fuel thermal stability research. The DSC was used to measure the heat of reaction versus temperature of a fuel sample heated at a programmed rate in an oxygen pressurized cell. Pure hydrocarbons and model fuels were studied using typical DSC operating conditions of 600 psig of oxygen and a temperature range from ambient to 500 C. The DSC oxidation onset temperature was determined and was used to rate the fuels on thermal stability. Kinetic rate constants were determined for the global initial oxidation reaction. Fuel deposit formation is measured, and the high temperature volatility of some tetralin deposits is studied by thermogravimetric analysis. Gas chromatography and mass spectrometry are used to study the chemical composition of some DSC stressed fuels.

Neveu, M. C.

Comparative results of autogenous ignition temperature measurements by ASTM G 72 and pressurized scanning calorimetry in gaseous oxygen

The autogenous ignition temperature of four materials was determined by ASTM (G 72) and pressurized differential scanning calorimetry at 0.68-, 3.4-, and 6.8-MPa oxygen pressure. All four materials were found to ignite at lower temperatures in the ASTM method. The four materials evaluated in this program were Neoprene, Vespel SP-21, Fluorel E-2160, and nylon 6/6.

Bryan, C. J.

Enthalpies of formation of CaAl4O7 and CaAl12O19 (hibonite) by high temperature, alkali borate solution calorimetry

Enthalpies of formation were determined for two calcium aluminate phases, CaAl4O7 and CaAl12O19, using high-temperature alkali borate solution calorimetry. The aluminates were synthesized by multiple-cycle heating and grinding stoichiometric mixtures of CaCO3 and Al2O3, and the products were characteized by X-ray diffraction and SEM microbeam analysis. The data on impurities (CaAl4O7 was found to be about 89.00 percent pure by weight and the CaAl12O19 samples about 91.48 percent pure) were used to correct the heat of solution values of the synthetic products. The enthalpies of formation, at 1063 K, from oxides, were found to be equal to -(25.6 + or - 4.7) kJ/g.f.w. for CaAl4O7 and -(33.0 + or - 9.7) kJ/g.f.w. for CaAl12O19; the respective standard enthalpies of formation from elements, at 298 K, were estimated to be -4007 + or - 5.2 kJ/g.f.w. and -10,722 + or - 12 kJ/g.f.w.

Geiger, C. A.

Differential Scanning Calorimetry (DSC) for planetary surface exploration

Differential Scanning Calorimetry (DSC) is the quantitative measurement of the enthalpic response of a material to a systematic change in temperature. In practice, the heat flow into or outward from a sample is measured as the sample is heated or cooled at a carefully controlled rate. DSC superficially resembles, but is not the same as differential thermal analysis (DTA), which is the measurement of temperature differences between a sample and reference material as the pair is heated or cooled. The fundamental properties measured by DSC are enthalpies and temperatures of phase transitions and constant-pressure heat capacities. Depending on instrument design and the nature of the sample, high-quality DSC analyses can be obtained on only a few milligrams of solid materials. DSC requires direct contact with the sample and generally degrades, if not destroys, the sample as a consequence of heating. In laboratory applications, it is common to subject the gaseous effluent from the DSC to analysis by a separate evolved-gas analyzer (EGA).

Gooding, James L.

AC Calorimetry and Thermophysical Properties of Bulk Glass-Forming Metallic Liquids

Thermo-physical properties of two bulk metallic glass forming alloys, Ti34Zr11Cu47Ni8 (VIT 101) and Zr57Nb5Ni12.6Al10CU15.4 (VIT 106), were investigated in the stable and undercooled melt. Our investigation focused on measurements of the specific heat in the stable and undercooled liquid using the method of AC modulation calorimetry. The VIT 106 exhibited a maximum undercooling of 140 K in free radiative cooling. Specific heat measurements could be performed in stable melt down to an undercooling of 80 K. Analysis of the specific heat data indicate an anomaly near the equilibrium liquidus temperature. This anomaly is also observed in y the temperature dependencies of the external relaxation time, the specific volume, and the surface tension; it is tentatively attributed to a phase separation in the liquid state. The VIT 101 specimen exhibited a small undercooling of about 50 K. Specific heat measurements were performed in the stable and undercooled melt. These various results will be combined with ground based work such as the measurement of T-T-T curves in the electrostatic levitator and low temperature viscosity and specific heat measurements for modeling the nucleation kinetics of these alloys.

Johnson, William L.

Differential Scanning Calorimetry and Evolved Gas Analysis at Mars Ambient Conditions Using the Thermal Evolved Gas Analyzer (TEGA)

Differential Scanning Calorimetry (DSC) combined with evolved gas analysis (EGA) is a well developed technique for the analysis of a wide variety of sample types with broad application in material and soil sciences. However, the use of the technique for samples under conditions of pressure and temperature as found on other planets is one of current C development and cutting edge research. The Thermal Evolved Gas Analyzer (MGA), which was designed, built and tested at the University of Arizona's Lunar and Planetary Lab (LPL), utilizes DSC/EGA. TEGA, which was sent to Mars on the ill-fated Mars Polar Lander, was to be the first application of DSC/EGA on the surface of Mars as well as the first direct measurement of the volatile-bearing mineralogy in martian soil.

Musselwhite, D. S.

Differential Scanning Calorimetry and Evolved Gas Analysis at Mars Ambient Conditions Using the Thermal Evolved Gas Analyser (TEGA)

Differential Scanning Calorimetry (DSC) combined with evolved gas analysis (EGA) is a well developed technique for the analysis of a wide variety of sample types with broad application in material and soil sciences. However, the use of the technique for samples under conditions of pressure and temperature as found on other planets is one of current development and cutting edge research. The Thermal Evolved Gas Analyzer (TEGA), which was designed, built and tested at the University of Arizona's Lunar and Planetary Lab (LPL), utilizes DSC/EGA. TEGA, which was sent to Mars on the ill-fated Mars Polar Lander, was to be the first application of DSC/EGA on the surface of Mars as well as the first direct measurement of the volatile-bearing mineralogy in martian soil. Additional information is available in the original extended abstract.

Musselwhite, D. S.

Laboratory Annealing Experiments Of Refractory Silicate Grain Analogs Using Differential Scanning Calorimetry

Exothermic reactions during the annealing of laboratory synthesized amorphous magnesium-bearing silicate particles used as grain analogs of cosmic dust were detected by differential scanning calorimetry (DSC) in air. With infrared spectroscopy and transmission electron microscopy, we show that cosmic dust could possibly undergo fusion to larger particles, with oxidation of magnesium silicide and crystallization of forsterite as exothermic reactions in the early solar system. The reactions begin at approximately 425, approximately 625, and approximately 1000 K, respectively, and the reaction energies (enthalpies) are at least 727, 4151, and 160.22 J per gram, respectively. During the crystallization of forsterite particles, the spectral evolution of the 10 micrometer feature from amorphous to crystalline was observed to begin at lower temperature than the crystallization temperature of 1003 K. During spectral evolution at lower temperature, nucleation and/or the formation of nanocrystallites of forsterite at the surface of the grain analogs was observed.

Kimura, Yuki

Combining Fractional Calorimetry with Statistical Methods to Characterize Thermal Runaway

Fractional thermal runaway calorimetry (FTRC) techniques were introduced to examine thermal runaway (TR) behavior of lithium-ion (Li-ion) cells. Specifically, FTRC considers the total energy released vs. the fraction of the total energy that is released through the cell casing vs. through the ejecta material. This device has been expanded to universally support FTRC testing of additional cell types including 21700-format, D-Cell format, and large prismatic format Li-ion cells. The TR behavior as influenced by cell format, manufacturer, chemistry, capacity, and in situ safety features are described in this presentation.

Walker, William

Physical characterization of High Entropy Alloys through Differential Scanning Calorimetry and Nanoindentation

In recent years several accelerator facilities have been limiting their beam power output not due to constraint of the accelerators but by concerns on the survivability of their targets, which in turn has led to R&D efforts into new, more resistant materials. One of these novel materials are High Entropy Alloys, the main focus of the internship project. This paper details the activities performed during the CCI 10-week internship by the authors, as well as to discuss the results obtained from said internship. The project consisted of the physical characterization of 12 batches of High Entropy Alloys (HEAs); the methods used to analyze the materials were Nanoindentation, which allows to determine the elastic modulus of the material and its hardness, and Differential Scanning Calorimetry (DSC), allowing the determination of specific heat.

Pacheco Uribe, Rene

Hydrothermal solution calorimetry in acidic aqueous solutions and revisiting the standard partial molal thermodynamic properties of Nd 3+ from 25 to 300 °C

The mobility of rare earth elements (REE) can be predicted in aqueous fluids using geochemical modeling but the accuracy of these models strongly depends on the availability of robust thermodynamic properties for the REE aqueous species. The REE 3+ aqua ions are important in the derivation of the formation constants of all the major REE complexes including the chloride, sulfate, and fluoride species which predominate in many hydrothermal-magmatic systems. However, the thermodynamic properties of the REE 3+ aqua ions are still commonly derived from the Helgeson-Kirkham-Flowers (HKF) equation of state parameters tabulated several decades ago. The standard state thermodynamic properties at reference conditions (25 °C and 1bar) and their extrapolations to high temperature need to be verified, if not revised, based on hydrothermal experiments. In this study, the enthalpy of solution was measured for synthetic Nd hydroxide from 25 to 150 ºC to retrieve the standard partial molal thermodynamic properties of Nd 3+ as a function of temperature. The experiments were conducted in aqueous perchloric acid based solutions with starting pH of 2 and varying ionic strength (0.01 to 0.09 mol/kg NaClO 4 ). The standard partial molal enthalpy of formation (Δ f H°) of Nd 3+ derived from the experimental study displays differences of up to 10 kJ/mol compared to the enthalpy values derived from the HKF equation of state in the studied temperature range. These inaccuracies are resolved by adjusting the standard partial molal Gibbs energy of formation (Δ f G°) of Nd 3+ at 25 °C and 1 bar from -672.0 to -679.7 kJ/mol. The heat capacity function (C p °) derived between 25 and 150 ºC can be described by: C p ° = a 0 + a 1 ·T + a 2 ·T -2 , with a 0 = 1256, a 1 = -2.68, a 2 = -55.56·10 6 and T in Kelvin. A set of recommended thermodynamic properties is provided for the Nd 3+ aqua ions and corrections are provided for the chloride and fluoride species to remain internally consistent with the experimentally derived properties. These results allow predicting accurately the solubility of monazite between 25 and 300 ºC. Before these corrections, the properties for the Nd 3+ aqua ions derived from the HKF parameters resulted in up to ~1.5 orders of magnitude lower monazite solubility than determined experimentally. Here, a revision of the REE +3 aqua ions properties is necessary to accurately predict the mobility of REE in hydrothermal acidic solutions.