Substation-Level Grid Topology Optimization Using Bus Splitting

Operations of substation circuit breakers are important for maintenance needs and topology reconfiguration in power systems. Bus splitting is one type of topology change where the two bus bars at a substation can become electrically disconnected under certain actions of circuit breakers. Because these events involve detailed substation modeling, they are typically not considered in routine power system operation and control. In this paper, an improved substation-level topology optimization framework is developed by expanding traditional line switching decisions by breaker-level bus splitting, which can further reduce grid congestion and generation costs. A tight McCormick relaxation is proposed to reformulate the bilinear terms in the resultant optimization problem to linear inequality constraints. Thus, a tractable mixed-integer linear program reformulation is attained that allows for efficient solutions in real-time operations. Numerical studies on the IEEE 14-bus and 118-bus systems demonstrate the computational performance and economic benefits of the proposed topology optimization approach.

bus split↗

Substation-Level Grid Topology Optimization Using Bus Splitting: Preprint

Operations of substation circuit breakers are of high significance for performing system maintenance and topology optimization. Bus splitting is one type of topology changes where the two bus-bars at a substation become electrically disconnected after certain actions of circuit breakers. As these events involve detailed substation modeling, they are not typically considered in power system routine operation and control. In this paper, an improved substation-level topology optimization is developed by expanding traditional line switching with breaker-level bus splitting, which can further reduce grid congestion and generation costs. A tight McCormick relaxation is proposed to reformulate the bi-linear terms in the resultant topology optimization model. Thus, a tractable mixed-integer linear program formulation is presented which can be efficiently solved for real-time control. Numerical studies on the IEEE 14-bus and 118-bus systems demonstrate the performance and economic benefits of the proposed topology optimization approach.

bus split↗

Fuel Cell Bus Takes a Starring Role in the BurbankBus Fleet (Fact Sheet)

This fact sheet reports on the City of Burbank, California's fuel cell bus demonstration project and the U.S. Department of Energy's (DOE) involvement. Included are specifications for the fuel cell bus and information about its operation. BurbankBus, the city's mass transit entity, received a grant from the California Air Resources Board to fund its zero-emission bus demonstration and is collaborating with DOE's Fuel Cell Technologies Program to evaluate the bus performance. DOE's National Renewable Energy Laboratory will collect and analyze performance and operations data for at least one year. Researchers will use the data to better understand the technology and determine future development work. In addition, demonstration information will help fleets make informed purchase decisions.

08 HYDROGEN↗

Analyzing School Bus Electrification in Richmond, Virginia

School buses are an essential component of the transportation infrastructure, serving as a lifeline for students across the globe. However, the widespread use of diesel school buses has raised concerns about the health impact on millions of students exposed to harmful emissions daily. Recognizing this issue, school districts worldwide are urgently seeking cleaner energy alternatives. Electric school buses emerge as an environmentally friendly and sustainable option, fostering a healthier environment for both students and communities. However, school bus electrification faces the challenges of high upfront cost, cumbersome charging management, and constraints from power grids. To help school bus operators address those challenges, this study presents a data-driven analysis for school bus electrification. This study considered a real-world school bus system in Richmond, VA, and developed a mathematical programming model to analyze the system design, charging strategies, and charging load profiles for the electrification scenario. The study evaluated different charging strategies based on model outcomes, aiming to optimize efficiency and effectiveness. Ultimately, this research generated electric school bus charging demand profiles under various scenarios, shedding light on the feasibility and implications of transitioning to electric-powered school buses.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of the bus joint for the ITER Central Solenoid

The terminations of the Central Solenoid (CS) modules are connected to the bus extensions by joints located outside the CS in the gap between the CS and Torodial Field (TF) assemblies. These joints have very strict space limitations. Low resistance is a common requirement for all ITER joints. In addition, the CS bus joints will experience and must be designed to withstand significant variation in the magnetic field of several tenths of a Tesla per second during initiation of plasma. The joint resistance is specified to be less than 4 nOhm. The joints also have to be soldered in the field and designed with the possibility to be installed and dismantled in order to allow cold testing in the cold test facility. We have developed coaxial joints that meet these requirements and have demonstrated the feasibility to fabricate and assemble them in the vertical configuration. We introduced a coupling cylinder with superconducting strands soldered to the surface of the cable that can be installed in the ITER assembly hall and at the Cold Test Facility. This cylinder serves as a transition area between the CS module and the bus extension. We made two racetrack samples and tested four bus joints in our Joint Test Apparatus. Resistance of the bus joints was measured by a decay method and by a microvoltmeter; the value of the current was measured by the Hall probes. This measurement method was verified in the previous tests. The resistance of the joints varied insignificantly from 1.5 to 2 nOhm. One of the challenges associated with a soldered joint is the inability to use corrosive chemicals that are difficult to clean. This paper describes our development work on cable preparation, chrome removal, compaction, soldering, and final assembly and presents the test results.

Martovetsky, Nicolai N↗

Low-inductance direct current power bus

A DC power bus having reduced parasitic inductance and higher tolerable operating temperature is disclosed. In example embodiments, a bus structure overlies a printed circuit board, and an array of capacitors is arranged on a surface of the printed circuit board distal the bus structure. The bus structure comprises an upper metal plate, a lower metal plate, and a dielectric film interposed between the upper and lower metal plates. The capacitors are connected in parallel between conductive planes of the printed circuit board. The upper and lower metal plates of the bus structure are connected to respective conductive planes of the printed circuit board.

Neely, Jason C.↗

Electrified vehicle power conversion for low voltage bus

An electrified vehicle high voltage battery pack has series-connected battery units or cells combining to provide the high voltage. To power a low voltage bus (e.g., for low voltage accessories or charging a low voltage battery) in a balanced manner, a plurality of DC/DC converters each has an input coupled to a respective battery unit and the converters have respective outputs coupled in parallel to the low voltage bus. A first loop controller receives an actual bus voltage. The first controller generates a target current in response to the bus voltage adapted to regulate the actual bus voltage to a target voltage less than the high voltage. A second controller distributes the target current into a plurality of allocated current commands for respective converters according to respective states of charge of the battery units connected to the converters.

Hand, III, Michael J.↗

Bus Design for the Poloidal Field Coils of the NSTX-Upgrade Fusion Device

The National Spherical Torus eXperiment (NSTX) has undergone a major upgrade to NSTX-U at Princeton Plasma Physics Laboratory (PPPL). NSTX upgrade (NSTX-U) will double the toroidal field, plasma current, and neutral beam injection heating power, as well as significantly increase the pulse duration. NSTX-U uses three poloidal field (PF) coils at the vessel top and three at the bottom near the divertor areas to control the local plasma shape there. These shaping coils operate at a maximum terminal voltage of 2 kV, corresponding to a maximum current about 20 kA. To supply the power to the PF coils, hard copper bus bars are typically used near the vacuum vessel, while water cooled flexible cables are used away from the vessel. The detailed design of the hard copper bus bars will be covered in this article. During operation, these hard bus bars are subject to high electromagnetic (EM) forces, thermal displacement loads, as well as plasma halo loads due to disruption. The EM, thermal, and structural analysis were performed, and the results revealed that, with the worst loads combined, the new design meets the NSTX-U thermal, structural, and fatigue cycle requirements. Finally, the manufacturing and installation process of the bus work will be discussed at the end of this article.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Decision Support Framework for Grid-Aware Electric Bus Charge Scheduling

While there are many advantages to electric public transit vehicles, they also pose new challenges for fleet operators. One key challenge is defining a charge scheduling policy that minimizes operating costs and power grid disruptions while maintaining schedule adherence. An uncoordinated policy could result in some buses running out of charge before completing their trip, while a grid agnostic policy might incur higher energy costs or cause an adverse impact on the grid’s distribution system. We present a grid aware decision-theoretic framework for electric bus charge scheduling that accounts for energy price, grid load, and bus status. The framework connects environmental models for traffic (SUMO) and the electric grid (GridLAB-D) to a planner, which evaluates bus charging decisions with regard to their long-term effect on grid reliability and cost. The framework has been evaluated on a simulation of Richland, WA’s bus and grid network, and compared to greedy methods.

EV, machine leaning, EV-Grid, Transportation, Grid↗

SunLine Leads the Way in Demonstrating Hydrogen-Fueled Bus Technologies (Brochure)

This brochure describes SunLine Transit Agency's newest advanced technology fuel cell electric bus. SunLine is collaborating with the U.S. Department of Energy's Fuel Cell Technologies Program to evaluate the bus in revenue service. This bus represents the sixth generation of hydrogen-fueled buses that the agency has operated since 2000.

08 HYDROGEN↗

On the Impact of Bus Dwelling on Macroscopic Fundamental Diagrams

Network macroscopic fundamental diagrams (MFDs) have recently been shown to exist in real-world urban traffic networks. When present, MFDs can be used to model traffic dynamics within an urban network by dividing the network into a set of spatially compact homogeneous regions and tracking the average level of congestion in each region. Existing analytical methods to estimate MFD mostly focus on the behavior of a single type of vehicle and do not capture the patterns of mixed traffic (e.g., cars and buses). The existence of buses matters since a bus will block the movements of other vehicles when it dwells at the bus stop. This paper proposes an analytical method to estimate the impact of bus dwelling on a network’s MFD based on the network’s geometric features, traffic control strategies, and bus operation parameters, and validates the performance of the proposed method using simulations based on microscopic traffic models. Comparisons of the analytical and simulation results show that the proposed analytical method can generally provide a good estimate of the lower bound and upper bound of the network’s MFD.

Xu, Guanhao↗

Improving Resilience of Bus Bunching Holding Strategy through a Rolling Horizon Approach

Providing public transportation with quality service is critical to attracting more passengers to the system. However, high-demand routes are prone to the so-called bus bunching -- a tendency of buses to group as a consequence of variations in travel times and demands. Bus holding is applied to overcome this effect. In this study, we present a novel method for bus holding in which the control law is based only on the buses' position using a computationally efficient rolling horizon approach. The method uses similar inputs as linear control approaches while not increasing significantly the computational time. However, the method overcomes key a weakness of the linear control approach thanks to the explicit constraint handling that always ensures the control action effectiveness. Simulation experiments in a validation case and a model-specific for a bus rapid transit line in Curitiba, Brazil showed a reduced holding time and improved resilience, delivering more than 20% reduction in delay time accounting for the on-board and station delays.

33 ADVANCED PROPULSION SYSTEMS↗

Traffic signal design and simulation for vulnerable road users safety and bus preemption

Mostly, pedestrian car accidents occurred at a signalized interaction is because pedestrians cannot across the intersection safely within the green light. From the viewpoint of pedestrian, there might have two reasons. The first one is pedestrians cannot speed up to across the intersection, such as the elders. The other reason is pedestrians do not sense that the signal phase is going to change and their right-of-way is going to be lost. Developing signal logic to protect pedestrian, who is crossing an intersection is the first purpose of this study. In addition, to improve the reliability and reduce delay of public transportation service is the second purpose. Therefore, bus preemption is also considered in the designed signal logic. In this study, the traffic data of the intersection of Chong-Qing North Road and Min-Zu West Road, Taipei, Taiwan, is employed to calibrate and validate the signal logic by simulation. VISSIM 5.20, which is a microscopic traffic simulation software, is employed to simulate the signal logic. From the simulated results, the signal logic presented in this study can protect pedestrians crossing the intersection successfully. The design of bus preemption can reduce the average delay. However, the pedestrian safety and bus preemption signal will influence the average delay of cars largely. Thus, whether applying the pedestrian safety and bus preemption signal logic to an intersection or not should be evaluated carefully.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heisenberg spin bus as a robust transmission line for quantum-state transfer

We study quantum-state transfer (QST) through a strongly coupled antiferromagnetic spin chain (acting as a spin bus), between weakly coupled external qubits. By treating the weak coupling as a perturbation, we find that QST is enabled specifically by the second-order terms in the perturbative expansion. We show that QST is robust against disorder in the couplings, either within the bus or to the external qubits. We find that the protocol works when the qubits are attached to any node on an even-size bus or to the antiferromagnetic nodes on an odd-size bus. The optimal time for QST is found to depend nonmonotonically on qubit separation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extended Frequency Divider for Bus Frequency Estimation Considering Virtual Inertia from DFIGs

Accurate estimation of local bus frequency is important for effectively controlling both synchronous and nonsynchronous generators. As the power grid evolves to accommodate essential reliability services such as virtual inertia from nonsynchronous generators, conventional techniques to estimate frequency face challenges. This paper proposes a new frequency estimation method that can effectively include the inertia contributions from double-fed wind generators (DFIGs). This is achieved through the proposed extended frequency divider formula (FDF) to include the contributions of DFIGs via Thevenin equivalents. The proposed extended FDF does not suffer from numerical issues as compared to existing phasor angle derivative-based approaches. Moreover, the knowledge of the rotor speeds of the synchronous machine and DFIGs as well as of the network admittance matrix allows estimating the frequencies of all buses in the grid, thereby significantly improving system situational awareness with a limited number of measurements. Numerical results on the IEEE 39-bus power system with DFIGs show that the proposed method achieves more accurate bus frequency estimations than the original FDF formula and other approaches based on the numerical derivation of the bus voltage phase angles.

double-fed induction generator↗

Athena - Shuttle Bus Optimization and Event Driven Simulator [SWR 20-105]

The primary purpose of the software is to optimize shuttle routes to and from terminals, given some airport campus location like the rental car center. This code was developed as part of the DOE funded Athena project. One aspect of the Athena project was to investigate if the optimization of shuttle routes that move passengers to and from the five DFW terminals and the rental car center could result in lower energy consumption from the shuttle fleet while still maintaining an acceptable level of service to passengers. Hence, the optimization done by the code determines a set of shuttle routes, the type of shuttle on each route, and the number of shuttles servicing each route. The optimization aims to make these choices in a way that the energy consumption per hour by the fleet is minimized. Additionally, the software can fast simulate airport shuttle operations with collected data. The simulation inputs are passenger arrival rates, shuttle routes and frequencies, and simulation configurations. The outputs include: time dependent shuttle energy level, time dependent charging station usage, time dependent number of passengers on each bus, time dependent number of passengers at each bus stop, history of number of passengers left at each bus stop, route history of fleet shuttle buses and on-demand buses, and time dependent bus distance traveled.

Kelly, Kenneth↗

NREL Showcases Hydrogen Internal Combustion Engine Bus, Helps DOE Set Standards for Outreach (Fact Sheet)

This fact sheet describes the National Renewable Energy Laboratory's (NREL's) accomplishments in showcasing a Ford hydrogen-powered internal combustion engine (H2ICE) bus at The Taste of Colorado festival in Denver. NREL started using its U.S. Department of Energy-funded H2ICE bus in May 2010 as the primary shuttle vehicle for VIP visitors, members of the media, and new employees. In September2010, NREL featured the bus at The Taste of Colorado. This was the first major outreach event for the bus. NREL's educational brochure, vehicle wrap designs, and outreach efforts serve as a model for other organizations with DOE-funded H2ICE buses. Work was performed by the Hydrogen Education Group and Market Transformation Group in the Hydrogen Technologies and Systems Center.

08 HYDROGEN↗

BETO 2021 Peer Review - Biological Upgrading of Sugars (BUS) 2.3.2.105

The Biological Upgrading of Sugars (BUS) project directly targets the anaerobic conversion of lignocellulosic feedstocks into intermediate molecules readily upgradeable to fuel precursors. Recent efforts on the BUS project have a particular emphasis on the biological production of butyric acid, an intermediate that can be readily upgraded to sustainable aviation fuel, diesel blend-stocks, and high value chemicals. The BUS project approaches this direction through a combination of strain engineering, fermentation process engineering, development of novel separations technologies, and the design and build of pilot scale systems. Our ultimate project goal is to develop an integrated cost-effective process at pilot scale to achieve DOE's MYPP targets of $2.50/GGE. The major thrust of the BUS project over the last project cycle was on the development of integrated processes surrounding the anaerobic production of carboxylic acids using diverse Clostridium species. We developed and expanded genetic tools for several Clostridium species and rewired microbial metabolism in an attempt to maximize substrate utilization and flux towards butyric acid. We designed and built novel bioreactors with an in situ product recovery system enabling the biological production and recovery of highly purified acids. We leveraged this system to generate 100s of grams of acid from corn stover hydrolysate. In this presentation we highlight data surrounding our proposed process and accompanying results from technoeconomic and life-cycle analyses of our integrated process. Finally, we detail plans of our pilot scale reactor system that is in process and discuss our future routes towards achieving economically viable and sustainable diesel and jet blendstocks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗