Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Buildings and Connected Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Decoupling Power Quality Issues in Grid-Microgrid Network Using Microgrid Building Blocks

Microgrids are evolving as promising options to enhance reliability of the connected transmission and distribution systems. Traditional design and deployment of microgrids require significant engineering analysis. However, Microgrid Building Blocks (MBB), consisting of modular blocks that integrate seamlessly to form effective microgrids, are promising technologies to enable faster and broader adoption of microgrids. Back-to-Back converter placed at the point of common coupling of microgrid is an integral part of MBB. This paper presents applications of MBB to decouple power quality issues in grid-microgrid network serving power quality sensitive critical loads such as data centers, new grid-edge technologies such as vehicle-to-grid generation, and emergency condition loads such as electric vehicle charging loads during evacuation prior disaster events. Simulation results show that MBB effectively decouple the power quality issues across networks and allow network with low power quality to transfer high-power quality power to connected networks during emergency conditions.

Acharya, Samrat S. [BATTELLE (PACIFIC NW LAB)]↗

WaterTAP3 (The Water Technoeconomic Assessment Pipe-Parity Platform)

The Water Technoeconomic Assessment Pipe-Parity Platform (WaterTAP3) was developed under the National Alliance for Water Innovation (NAWI) to facilitate consistent technoeconomic assessments of desalination treatment trains. The WaterTAP3 is an analytically robust modeling tool that can be used to evaluate water technology cost, energy, environmental, and resiliency tradeoffs across different water sources, sectors, and scales. The model simulates steady-state water treatment train performance and costs including flow and constituent mass balance across unit processes, based on source water conditions, configurations of treatment technologies, and system-level techno-economic assumptions. Users can build a new treatment train by connecting any number of unit processes, specific for their context and system, or selecting a train from the treatment train library. The model contains various technical and cost parameter options for a range of treatment processes and a library of influent water quality characteristics for a variety of source waters and case studies. Users can customize water quality parameters to evaluate the technology performance in their context. The model can be set up for different assessment needs including simulation, optimization, and uncertainty and sensitivity analyses. The results from WaterTAP3 can help identify trade-offs among the different system performance metrics, with insight on how particular technologies or systems promote pipe-parity. The flexibility and comprehensive scope of the tool makes it a promising solution to industry-wide water technoeconomic evaluations, leading to more informed water investment decisions and technologies. As a user-friendly, open-source platform, WaterTAP3 can be used by industry, academia, policymakers, planners, and those with or without extensive analytical experience.

Miara, Ariel↗

Water Technoeconomic Assessment Pipe-Parity Platform (WaterTAP3)

The Water Technoeconomic Assessment Pipe-Parity Platform (WaterTAP3) was developed under the National Alliance for Water Innovation (NAWI) to facilitate consistent technoeconomic assessments of desalination treatment trains. The WaterTAP3 is an analytically robust modeling tool that can be used to evaluate water technology cost, energy, environmental, and resiliency tradeoffs across different water sources, sectors, and scales. The model simulates steady-state water treatment train performance and costs including flow and constituent mass balance across unit processes, based on source water conditions, configurations of treatment technologies, and system-level techno-economic assumptions. Users can build a new treatment train by connecting any number of unit processes, specific for their context and system, or selecting a train from the treatment train library. The model contains various technical and cost parameter options for a range of treatment processes and a library of influent water quality characteristics for a variety of source waters and case studies. Users can customize water quality parameters to evaluate the technology performance in their context. The model can be set up for different assessment needs including simulation, optimization, and uncertainty and sensitivity analyses. The results from WaterTAP3 can help identify trade-offs among the different system performance metrics, with insight on how particular technologies or systems promote pipe-parity. The flexibility and comprehensive scope of the tool makes it a promising solution to industry-wide water technoeconomic evaluations, leading to more informed water investment decisions and technologies. As a user-friendly, open-source platform, WaterTAP3 can be used by industry, academia, policymakers, planners, and those with or without extensive analytical experience. A publicly available graphical user interface is currently under development.

Miara, Ariel↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

Power over Ethernet (PoE) technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras. They are systems that are familiar to and managed by on-site IT staff. As low voltage DC-power capabilities have increased with the advancement of IT network switches within offices, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. The connection of PoE devices to network switches offers the opportunity for energy monitoring and management to be performed through IT network management software. Data and results from technology validations of PoE equipment remain very limited. This lack of information hinders expansion of PoE as an energy management strategy as its benefits and challenges have been insufficiently quantified in real-world scenarios. This final report presents the findings of a DOE/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at six sites: two offices, three schools, and a hotel. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where not typically available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Multiport DC Transformer to Enable Flexible Scalable DC as a Service

The rapid adoption of new DC loads and sources, including photovoltaic arrays, DC fast charging of electric vehicle, battery energy storage and data centers, requires a large amount of DC power conversion. A majority of new deployments also necessitate the integration of multiple DC loads and sources at one site. The traditional approach to serve these new applications relies on multiple standard power converters, each dedicated to a source or load, and results in highly customized systems, with challenging control coordination, complex protection strategies, and poor scalability. Instead, this paper proposes the concept of a multiport DC transformer (MDCT) as a modular building block for realizing a flexible, scalable DC as a Service system and address this rapidly growing need. The MDCT uses the S4T to achieve very tight control of cycle-by-cycle energy exchange between multiple ports, with high efficiency. A single multiport converter replaces 4-6 distinct converters, integrates all energy flows and manages protection. As a result, a new layered control architecture is introduced to ensure stability and scalability of the MDCT, with multiple S4T power converter building blocks connected in parallel to realize a fully modular system and reach the target power levels.

30 DIRECT ENERGY CONVERSION↗

Interoperable End-To-End Space Communications Architecture Using CCSDS Building Blocks

End-to-end space communication architectures must connect system elements that may be in space, on the ground in mission operations centers, or are shared assets such as ground communications stations. End-to-end connectivity involves space communications over RF links, but also cross support services, terrestrial network circuits, and a variety of application layer protocols for commanding, telemetry, and mission operations. CCSDS has developed a large suite of interoperable, and cross-supportable, protocols for these purposes. Each of these defines a specific “layer” of functionality, such as: RF modulation, space link error coding, cross support frame delivery, or network layer routing. CCSDS has recently published a Space Communication Cross Support Architecture Requirements Document (SCCS-ARD) that describes how many of these standards fit together and how they are intended to be used. This paper provides an overview of this document, presented so as to explain the concepts so that others may use them. These concepts will be described from several key viewpoints.

Shames, Peter M.↗

Interoperable End-To-End Space Communications Architectures Using CCSDS Building Blocks

End-to-end space communication architectures must connect system elements that may be in space, on the ground in mission operations centers, or are shared assets such as ground communications stations. End-to-end connectivity involves space communications over RF links, but also cross support services, terrestrial network circuits, and a variety of application layer protocols for commanding, telemetry, and mission operations. CCSDS has developed a large suite of interoperable, and cross-supportable, protocols for these purposes. Each of these defines a specific “layer” of functionality, such as: RF modulation, space link error coding, cross support frame delivery, or network layer routing. CCSDS has recently published a Space Communication Cross Support Architecture Requirements Document (SCCS-ARD) that describes how many of these standards fit together and how they are intended to be used. This paper provides an overview of this document, presented so as to explain the concepts so that others may use them. These concepts will be described from several key viewpoints.

Shames, Peter M.↗

Building-to-Grid Modeling Framework with a Case Study of Battery Systems

Coordinating electricity load shifting operations of multiple buildings has the potential to achieve significant benefits for both building owners and grid operation. In support of this research, this paper develops a novel building-to-grid modeling framework, which uses EnergyPlus to develop physics-based building energy models and GridLAB-D to develop distribution-level grid models. The data exchanges between buildings and distribution-level grid are conducted using Python script and HELICS co-simulation platform. Then, by using this modeling framework, this paper conducts a case study of battery systems in a connected community, which consists of 10 multi-family buildings with appropriately sized batteries. The three scenarios, baseline operation, tolerant to price fluctuations, and opportune usage, are studied. The result displays that, by adopting onsite batteries, both electricity costs for building owners and aggregated peak power demands are reduced.

Building-to-grid, connected community, co-simulati↗

Maximum-impact Adversary Design for Network-based Control System: A Case Study on Grid-interactive Efficient Buildings

The Internet of Things (IoT) technology has dramatically improved the efficiency of today's building operation and management. By connecting controllable devices into a communication network, control signals can be easily passed to the devices, and operating status can be acquired from measurable ends with minimal effort. However, this all-connected configuration could also expose the network-based control system (NBCS) to malicious actions, such as cyberattacks. One of the common NBCSs is the building automation system. With the promotion of grid-interactive efficient buildings (GEBs), there has been increasing attention on securing the buildings from the network perspective. This research proposes a maximum-impact adversary design framework so that the adversary can provide the most adversarial impact on the controlled system while remaining stealthy. The proposed framework is numerically demonstrated on a network-based building energy and control system. The building energy system is built in a Modelica-based simulation environment and controlled by the state-of-the-art ASHRAE Guideline 36 control sequences. The control commands at the supervisory level, generated from the Guideline 36 controller, are assumed to be sent to local devices through communication networks using the BACnet protocol. Simulation results show that the proposed maximum-impact adversary on such a system can stealthily affect the building system's performance to its maximum extent. It is anticipated that results can be used by researchers and practitioners in the building automation industry to design efficient and robust cyber-attack detection algorithms, especially for stealthy attacks.

Chu, Mengyuan↗

Methodology for object-oriented real-time systems analysis and design: Software engineering

Successful application of software engineering methodologies requires an integrated analysis and design life-cycle in which the various phases flow smoothly 'seamlessly' from analysis through design to implementation. Furthermore, different analysis methodologies often lead to different structuring of the system so that the transition from analysis to design may be awkward depending on the design methodology to be used. This is especially important when object-oriented programming is to be used for implementation when the original specification and perhaps high-level design is non-object oriented. Two approaches to real-time systems analysis which can lead to an object-oriented design are contrasted: (1) modeling the system using structured analysis with real-time extensions which emphasizes data and control flows followed by the abstraction of objects where the operations or methods of the objects correspond to processes in the data flow diagrams and then design in terms of these objects; and (2) modeling the system from the beginning as a set of naturally occurring concurrent entities (objects) each having its own time-behavior defined by a set of states and state-transition rules and seamlessly transforming the analysis models into high-level design models. A new concept of a 'real-time systems-analysis object' is introduced and becomes the basic building block of a series of seamlessly-connected models which progress from the object-oriented real-time systems analysis and design system analysis logical models through the physical architectural models and the high-level design stages. The methodology is appropriate to the overall specification including hardware and software modules. In software modules, the systems analysis objects are transformed into software objects.

Schoeffler, James D.↗

Environmental control and air distribution system and method of using the same

An indoor environmental control and air distribution system for a building includes: an air handling unit; a manifold connected to the air handling unit having a chamber formed by a plurality of walls and a plurality of orifices formed through at least one of the walls; air distribution conduits each independently having a first end connected to the orifices of the manifold and a second end extending out from the manifold into different zones throughout the building; and an airflow modulating device having one or more airflow regulating dampers independently configured to move into at least two positions in which each position provides a different percentage of total air volume to each air distribution conduit. A method of using the indoor environmental control and air distribution system is also included.

Poerschke, Andrew↗

Environmental control and air distribution system and method of using the same

An indoor environmental control and air distribution system for a building includes: an air handling unit; a manifold connected to the air handling unit having a chamber formed by a plurality of walls and a plurality of orifices formed through at least one of the walls; air distribution conduits each independently having a first end connected to the orifices of the manifold and a second end extending out from the manifold into different zones throughout the building; and an airflow modulating device having one or more airflow regulating dampers independently configured to move into at least two positions in which each position provides a different percentage of total air volume to each air distribution conduit. A method of using the indoor environmental control and air distribution system is also included.

Poerschke, Andrew↗

Fault-tolerant computer system

More reliable computers could be assembled by connecting four proposed VSLI "building block" circuits with built-in error detection to standard microprocessors and memory devices to form self checking computer module. Each building block detects its own malfunctions and single bit errors found in memory.

Avizienis, A. A.↗

CYDRES: CYber Defense and REsilient System for securing grid-interactive efficient buildings

Smart buildings, especially Grid-interactive Efficient Buildings (GEBs), suffer from cyber-attacks and physical faults due to the integration of a large number of sensors and controls, connected devices, and associated communication networks. This study demonstrated a real-time advanced building resilient platform, called CYber Defense and REsilient System (CYDRES), which is deployable for existing and emerging Building Automation Systems (BASs). CYDRES aims to empower GEBs with cyber-attack-immune capabilities through multi-layer prevention and adaptation mechanisms to monitor, detect, and respond to cyber-attacks and physical operational faults. CYDRES is demonstrated through real-time experiments in a Hardware-in-the-Loop (HIL) testbed.

Building automation system, Cyber-attacks, Physica↗

Assessment of Low-Cost Minisplit Heat Pump Connection System

This project was funded by SCE's Emerging Technologies Program, and evaluates the feasibility of a connection system that can pave the path to accelerated, cost-effective adoption of high-efficiency Minisplit Heat Pump (MSHP) systems. This report details the characterization of this connection system and a heat pump enabled with this technology in a laboratory setting, and assesses the energy and cost impact applicable to residential buildings in SCE service territory. The energy and economic analysis leverages NREL's ResStock TM modeling approach based on the EnergyPlus ® hourly simulation platform. The connection system can be incorporated into existing MSHP architectures. This reduces installation time from 10 to 20 man hours to approximately one hour or less, dramatically lowering total installation costs without adversely impacting heat pump performance. This report characterizes the connection system's leakage performance while connected and disconnected, as well as leakage over several connection/disconnection cycles, commensurate with manufacturer specifications for the individual components. The connector was incorporated into an off-the-shelf MSHP. Performance was compared to an identical unmodified heat pump. The connector had no impact on performance. Large-scale hourly energy simulations were performed for 22,574 homes across 15 counties in SCE service territory. The analysis was performed using baseline assumptions about the penetrations of window air conditioners (~18%) and six upgrade scenarios for these air conditioners. All scenarios assumed 100% adoption of the Connector-Supported Heat Pump (CSHP) in place of window air conditioners: MSHPs at Seasonal Energy Efficiency Ratio (SEER) 17, 25, and 33, and CSHPs at SEER 17, 25, and 33. Results show the increased adoption of high-efficiency heat pumps can result in up to 29% air conditioning energy savings for homes with window air conditioners.

42 ENGINEERING↗

Higher Education Buildings Recognized for Integrated Controls for HVAC and Lighting Systems - Case Study: California State University Dominguez Hills and University of Minnesota

This case study describes connected lighting system projects on two college campuses; Cal State Dominguez Hills and the University of Minnesota both implemented lighting and controls upgrades at mixed-use buildings, including advanced sensors, HVAC integration, and plug load control. Both projects were recognized by DOE's Integrated Lighting Campaign.

integrated lighting, higher education, college, un↗

Helium recovery system at IB3a

The increasing need for optimal and sustainable use of cryogenic resources to support Fermilab’s scientific mission has highlighted the necessity of improving the Laboratory’s helium management practices. An assessment of cryogenic test facilities identified the Technical Division’s Industrial Building 3a (IB3A) as a key site requiring upgrades to integrate a helium recovery system. The IB3A facility is essential for characterizing and testing superconductors, cables, and coils for various R&D projects, including the US High-Luminosity LHC Accelerator Upgrade Project (AUP), Mu2e, and other external collaborations. Currently, the facility relies on 500 L helium Dewars and vents the vaporized helium directly into the atmosphere, leading to significant helium loss. Given the non-renewable nature of helium, recovering and reusing this resource is critical for the sustainability of Fermilab’s operations. To address this challenge, a project has been initiated to connect IB3A to an existing helium purification station and refrigeration system located in another building via a dedicated pipeline pass over the roof of several buildings. This solution will enable the efficient capture of vented helium, its transfer to the purification station, and subsequent liquefaction for reuse in future operations. The project includes a detailed design phase, specifying the pipeline route, flow control mechanisms, and integration with the existing cryogenic infrastructure, followed by phased implementation and commissioning. By implementing this pipeline connection and upgrading IB3A, Fermilab aims to significantly reduce helium waste, lower operational costs, and align with its commitment to sustainability. This initiative provides a model for resource-efficient cryogenic operations and reinforces the Laboratory’s capacity to support its science mission for the long term.

Porwisiak, D. [Fermilab]↗

System Advisor Model (SAM) and PVWatts

The System Advisor Model (SAM) is a free techno-economic software model that facilitates decision-making for people in the renewable energy industry. PVWatts estimates the energy production of grid-connected photovoltaic energy systems throughout the world. It allows homeowners, small building owners, installers, and manufacturers to easily develop estimates of the performance of potential photovoltaic installations.

energy planning↗