Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bragg peak”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Proton Radiotherapy to Preserve Fertility and Endocrine Function: A Translational Investigation

Photon radiation therapy (x-ray radiation therapy [XRT] and gamma-ray radiation therapy [GRT]) of tumors close to ovaries causes reproductive and endocrine sequelae due to ovarian primordial follicle depletion. Given its finite range, proton radiation therapy (PRT) can preserve ovarian function when ovaries are positioned distal to the spread-out Bragg peak (SOBP) in tumors of the abdominopelvic region. This study compared anti-Müllerian hormone (AMH) levels (a biomarker of ovarian function) and primordial follicle survival after in vivo mouse pelvic GRT versus PRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Heterogeneous Ice Growth in Micron-Sized Water Droplets Due to Spontaneous Freezing

Understanding how ice nucleates and grows into larger crystals is of crucial importance for many research fields. The purpose of this study was to shed light on the phase and structure of ice once a nucleus is formed inside a metastable water droplet. Wide-angle X-ray scattering (WAXS) was performed on micron-sized droplets evaporatively cooled to temperatures where homogeneous nucleation occurs. We found that for our weak hits ice grows more cubic compared to the strong hits that are completely hexagonal. Due to efficient heat removal caused by evaporation, we propose that the cubicity of ice at the vicinity of the droplet’s surface is higher than for ice formed within the bulk of the droplet. Moreover, the Bragg peaks were classified based on their geometrical shapes and positions in reciprocal space, which showed that ice grows heterogeneously with a significant population of peaks indicative of truncation rods and crystal defects. Frequent occurrences of the (100) reflection with extended in-planar structure suggested that large planar ice crystals form at the droplet surface, then fracture into smaller domains to accommodate to the curvature of the droplets. Planar faulting due to misaligned domains would explain the increased cubicity close to the droplet surface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Annealing of focused ion beam damage in gold microcrystals: an in situ Bragg coherent X-ray diffraction imaging study

Focused ion beam (FIB) techniques are commonly used to machine, analyse and image materials at the micro- and nanoscale. However, FIB modifies the integrity of the sample by creating defects that cause lattice distortions. Methods have been developed to reduce FIB-induced strain; however, these protocols need to be evaluated for their effectiveness. Here, non-destructive Bragg coherent X-ray diffraction imaging is used to study the in situ annealing of FIB-milled gold microcrystals. Two non-collinear reflections are simultaneously measured for two different crystals during a single annealing cycle, demonstrating the ability to reliably track the location of multiple Bragg peaks during thermal annealing. The thermal lattice expansion of each crystal is used to calculate the local temperature. This is compared with thermocouple readings, which are shown to be substantially affected by thermal resistance. To evaluate the annealing process, each reflection is analysed by considering facet area evolution, cross-correlation maps of the displacement field and binarized morphology, and average strain plots. The crystal's strain and morphology evolve with increasing temperature, which is likely to be caused by the diffusion of gallium in gold below ~280°C and the self-diffusion of gold above ~280°C. The majority of FIB-induced strains are removed by 380–410°C, depending on which reflection is being considered. These observations highlight the importance of measuring multiple reflections to unambiguously interpret material behaviour.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Atomically Resolved Acoustic Dynamics Coupled with Magnetic Order in a Van der Waals Antiferromagnet

Magnetoelastic coupling in van der Waals (vdW) magnetic materials enables a unique interplay between the spin and lattice degrees of freedom. Characterizing the elastic responses with atomic and femtosecond resolution across the magnetic transition is essential for guiding the design of magnetically tunable actuators and strain-mediated spintronic devices. Here, ultrafast X-ray diffraction employed at a free-electron laser reveals that the atomic displacements, wave vectors, and dispersion relations of acoustic phonon modes in a vdW antiferromagnet FePS3 are coupled with the magnetic order, by tracking both in-plane and out-of-plane Bragg peaks upon optical excitation across the Néel temperature (TN). One transverse mode shows that a quasi-out-of-plane atomic displacement undergoes a significant directional change across TN. Its quasi-in-plane wave vector is derived by comparing the measured sound velocity and the first-principles calculations. The other transverse mode is an interlayer shear acoustic mode whose amplitude is strongly enhanced in the antiferromagnetic phase, exhibiting eight times stronger amplitude than the longitudinal acoustic mode below TN. The atomically resolved characterization of acoustic phonon dynamics that couple with magnetic ordering opens opportunities for harnessing unique magnetoelastic coupling in vdW magnets on ultrafast timescales.

coherent acoustic phonons↗

Field‐Induced Ferroelectric Phase Evolution During Polarization “Wake‐Up” in Hf 0.5 Zr 0.5 O 2 Thin Film Capacitors

Abstract As an emerging nonvolatile memory technology, HfO 2 ‐based ferroelectrics exhibit excellent compatibility with silicon CMOS process flows; however, the reliability of polarization switching in these materials remains a major challenge. During repeated field programming and erase of the polarization state of initially pristine HfO 2 ‐based ferroelectric capacitors, the magnitude of the measured polarization increases, a phenomenon known as “wake‐up”. In this study, the authors attempt to understand what causes the wake‐up effect in Hf 0.5 Zr 0.5 O 2 (HZO) capacitors using nondestructive methods that probe statistically significant sample volumes. Synchrotron X‐ray diffraction reveals a concerted shift in HZO Bragg peak position as a function of polarization switching cycle number in films prepared under conditions such that they exhibit extremely large (≈3000%) wake‐up. In contrast, a control sample with insignificant wake‐up shows no such peak shift. Capacitance – voltage measurements show evolution in the capacitance loop with switching cycle number for the wake‐up sample and no change for the control sample. Piezoresponse force microscopy measurements are utilized to visualize the domain switching with wake‐up. The combination of these observations clearly demonstrates that wake‐up is caused by a field‐driven phase transformation of the tetragonal phase to the metastable ferroelectric orthorhombic phase during polarization switching of HZO capacitors.

36 MATERIALS SCIENCE↗

On the perturbation effect and LET dependence of beam quality correction factors in carbon ion beams

Background: In a recent study, we reported beam quality correction factors, f Q , in carbon ion beams using Monte Carlo (MC) methods for a cylindrical and a parallel-plate ionization chamber (IC). A non-negligible perturbation effect was observed; however, the magnitude of the perturbation correction due to the specific IC subcomponents was not included. Furthermore, the stopping power data presented in the International Commission on Radiation Units and Measurements (ICRU) report 73 were used, whereas the latest stopping power data have been reported in the ICRU report 90. Purpose: The aim of this study was to extend our previous work by computing f Q correction factors using the ICRU 90 stopping power data and by reporting IC-specific perturbation correction factors. Possible energy or linear energy transfer (LET) dependence of the f Q correction factor was investigated by simulating both pristine beams and spread-out Bragg peaks (SOBPs). Methods: The TOol for PArticle Simulation (TOPAS)/GEANT4 MC code was used in this study. A 30 × 30 × 50 cm 3 water phantom was simulated with a uniform 10 × 10 cm 2 parallel beam incident on the surface. A Farmer-type cylindrical IC (Exradin A12) and two parallel-plate ICs (Exradin P11 and A11) were simulated in TOPAS using the manufacturer-provided geometrical drawings. The f Q correction factor was calculated in pristine carbon ion beams in the 150–450 MeV/u energy range at 2 cm depth and in the middle of the flat region of four SOBPs. The k Q correction factor was calculated by simulating the f Qo correction factor in a 60 Co beam at 5 cm depth. The perturbation correction factors due to the presence of the individual IC subcomponents, such as the displacement effect in the air cavity, collecting electrode, chamber wall, and chamber stem, were calculated at 2 cm depth for monoenergetic beams only. Additionally, the mean dose-averaged and track-averaged LET was calculated at the depths at which the f Q was calculated. Results: The ICRU 90 f Q correction factors were reported. The p dis correction factor was found to be significant for the cylindrical IC with magnitudes up to 1.70%. The individual perturbation corrections for the parallel-plate ICs were <1.0% except for the A11 p cel correction at the lowest energy. The f Q correction for the P11 IC exhibited an energy dependence of >1.00% and displayed differences up to 0.87% between pristine beams and SOBPs. Conversely, the f Q for A11 and A12 displayed a minimal energy dependence of <0.50%. The energy dependence was found to manifest in the LET dependence for the P11 IC. A statistically significant LET dependence was found only for the P11 IC in pristine beams only with a magnitude of <1.10%. Conclusions: The perturbation and k Q correction factor should be calculated for the specific IC to be used in carbon ion beam reference dosimetry as a function of beam quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Boosting background suppression in the NEXT experiment through Richardson-Lucy deconvolution

Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of ~ 10 27 yr, requiring suppressing backgrounds to < 1 count/tonne/yr. For this, any extra background rejection handle, beyond excellent energy resolution and the use of extremely radiopure materials, is of utmost importance. The NEXT experiment exploits differences in the spatial ionization patterns of double beta decay and single-electron events to discriminate signal from background. While the former display two Bragg peak dense ionization regions at the opposite ends of the track, the latter typically have only one such feature. Thus, comparing the energies at the track extremes provides an additional rejection tool. The unique combination of the topology-based background discrimination and excellent energy resolution (1% FWHM at the Q-value of the decay) is the distinguishing feature of NEXT. Previous studies demonstrated a topological background rejection factor of ~ 5 when reconstructing electron-positron pairs in the 208Tl 1.6 MeV double escape peak (with Compton events as background), recorded in the NEXT-White demonstrator at the Laboratorio Subterráneo de Canfranc, with 72% signal efficiency. This was recently improved through the use of a deep convolutional neural network to yield a background rejection factor of ~ 10 with 65% signal efficiency. Here, we present a new reconstruction method, based on the Richardson-Lucy deconvolution algorithm, which allows reversing the blurring induced by electron diffusion and electroluminescence light production in the NEXT TPC. The new method yields highly refined 3D images of reconstructed events, and, as a result, significantly improves the topological background discrimination. When applied to real-data 1.6 MeV e - e + pairs, it leads to a background rejection factor of 27 at 57% signal efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronic Melting of Silicon in Nanostructures using X-ray Forbidden Bragg Reflections

Abstract We carried out a short beamtime at the Pohang Accelerator Laboratory x-ray Free Electron Laser to perform a pump-probe (PP) laser excitation diffraction experiment on the silicon (222) forbidden Bragg peak. To limit the x-ray penetration, we used a “device layer” silicon film wafer bonded to a silicon substrate. The sample, specially fabricated by MEMC Electronic Materials, had a Si(100) substrate bonded to a 170 nm Si(100) film rotated at 45° for crystallographic isolation. A second sample was reactive-ion-etched down to 52 nm thickness. In the silicon lattice, the covalent bonds are seen exclusively at the 222 reflection. Upon laser excitation, these electrons are expected to be excited to the valence band on femtosecond electronic time scales. The Si(222) reflection is therefore expected to be extinguished on this fast time scale, while the electron–phonon coupled acoustic response is determined by the lattice dynamics. The latter is determined by the speed of sound over the device thickness, which is in the mid-picosecond range.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

An efficient computational framework for charge density estimation in twisted bilayer graphene

Electronic properties such as band structure and Fermi velocity in low-angle twisted bilayer graphene (TBG) are intrinsically dependent on the atomic structure. Rigid rotation between individual graphene layers provides an approximate description of the bilayer symmetry. Upon relaxation, in-plane displacement of the atoms in low angle TBG causes a change in the symmetry through the enlargement of the AB stacking regions and the reduction in size of AA and SP stacking regions. However, the effect of this in-plane relaxation on the charge density remains unexplored, because the necessary electronic structure calculations of such large supercells of low twist angle TBG are computationally infeasible. Therefore, we develop a computationally efficient framework that enables the exploration of the charge density symmetry of the low twist angle TBG. This framework is based on the Fourier representation of the charge density which presents high intensity Bragg peaks. Here we find that with the decrease of twist angle, low intensity satellite peaks also become apparent. Our framework incorporates these satellite peaks which reveals transformation of symmetry in the charge density distribution from high to low twist angle TBG. One striking outcome is the demonstration of the electron localization in the AA region of low twist angle TBG. Our framework helps to explain the effect of the atomistic relaxation on the charge density distribution and thus, it provides information about exotic electronic properties of low twist angle TBG at a low computational expense.

36 MATERIALS SCIENCE↗

Magnetic structure of triangular lattice compound Tb2Ni0.90Si2.94

AlB 2 -type ternary intermetallic compound Tb 2 Ni 0.90 Si 2.94 (space group P 6=mmm, hP 3, No. 191) was reported to exhibit spin freezing behaviour of the ferromagnetic clusters present in the system below T f = 9:9 K, along with the presence of spatially limited antiferromagnetic phase. In this work, on the basis of variable temperature zero-field neutron diffraction measurements, we have shown that the antiferromagnetic phase transition occurs for the compound below T N ~13 K. Neutron diffraction study indicates ab-plane non-collinear sine-modulated antiferromagnetic ordering of the system with wave vectors of k 1 = [±1/6, ±1/6, 0] and k 2 = [±1/3, ±1/3, 0] down to 1.7 K. The weak and diffuse nature of the magnetic Bragg peaks along with limited coherence length further confirm the short-range nature of the antiferromagnetic phase in this compound.

36 MATERIALS SCIENCE↗

Magnetic structure of topological nodal-line semimetal EuSb 2

Here, we investigated the magnetic structure of the magnetic topological nodal-line semimetal EuSb 2 using x-ray resonant magnetic scattering at the Eu 𝐿 3 absorption edge. Forbidden magnetic reflections confirm antiferromagnetic ordering with propagation vector 𝐪 = (0.5,0,0) below 𝑇 N ≈ 27 K. Azimuthal-angle-dependent measurements reveal that the Eu moments are aligned along the monoclinic 𝑏 axis. Comparison between the measured 𝐐-dependent magnetic Bragg peak intensities and calculations based on representation analysis identifies the magnetic structure as the A-type antiferromagnetic 𝛤 4 representation with a (++−−) arrangement along the 𝑎 direction. These results establish the microscopic magnetic structure of EuSb 2 and provide a basis for understanding the interplay between antiferromagnetism and topological electronic states in this system.

36 MATERIALS SCIENCE↗

Visualizing electrode assembly movement and lithiation heterogeneity in lithium-metal batteries using operando energy dispersive X-ray diffraction

There is renewed interest in Li-metal anodes in order to increase the energy density of battery cells. Here, we demonstrate an operando X-ray crystallography method to visualize lithiation gradients and electrode assembly movement during electrochemical cycling of a Li-metal cell containing a Ni-Mn-Co layered oxide cathode (NMC811). During charge, deposition of Li + ions from the cathode increases the Li foil thickness; during discharge, the thickness decreases as Li + ions are stripped off the foil. Additionally, the resulting periodic movement is observed through tracking of Bragg peaks from the ordered phases of the cathode and separator. In addition to this 3.6 μm/mAh displacement, continuous mossy Li build-up on the anode causes an irreversible drift of the assembly, which is similar to 11.3 μm/cycle. Furthermore, our data indicate significant lithiation gradients in the NMC811 cathode during the oxide relithiation, which is not observed during the delithiation.

25 ENERGY STORAGE↗

Search for octupolar order in NpO 2 by neutron powder diffraction

The magnetic structure of neptunium dioxide (NpO 2 ) remains a mystery despite decades of research. We revisited the search for magnetic ordering in NpO 2 by performing a powder neutron diffraction experiment at low temperatures and relatively large values of Q. Diffraction data were collected for 300 MK, 15 K, and 35 K to understand the phase transition near 25 K. However, no significant changes in the neutron diffraction pattern were identified. Using the octupolar magnetic form factor j 6 , the maximum theoretical expected value of the magnetic moment (3.27 μ B ), the calculated magnetic Bragg peak intensities would not be observable in neutron powder diffraction data. This value is much larger than the previously estimated magnetic moment of ~0.1 μ B . In conclusion, supported by experimental results, these calculations suggest that unpolarized neutron powder diffraction is unsuitable for measuring octupolar ordering in NpO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multicycle flash sintering of cubic Y 2 O 3 -stabilized ZrO 2 : An in situ energy dispersive synchrotron x-ray diffraction study with high temporal resolution

The current induced unit cell volume changes, (111) Bragg peak full width at half maximum (FWHM) and its integrated intensity in 8 % Y 2 O 3 stabilized ZrO 2 (8 %YSZ) solid state electrolyte was monitored during a triple-flash sintering experiment by in situ energy dispersive x-ray diffraction using a polychromatic synchrotron probe (max, photon energy 200 keV) with 2 second temporal resolution. The first spontaneous singularity in the unit cell volume (+0.54 %) was observed at 899 °C under 15 V/mm applied field intensity, which was associated with 13 mA/mm 2 current draw and an increase in density to 97 %. Following anelastic relaxation of the unit cell volume under open circuit conditions, the same applied field was applied twice in a row which resulted in additional induced singularities at 925 °C (+0.48 %) and 944 °C (+0.42 %). A floating baseline, which was above the thermal expansion baseline, was observed from 833 to 969 °C and was attributed to Joule heating. In conclusion, the singularity at 899 °C is associated with a sharp change in (111) FWHM and a 34 % decrease in integrated peak area that was attributed to changes in the distribution of oxygen vacancies and the changes in their concentration as induced by the applied field in the spontaneous transient stage of flash sintering.

36 MATERIALS SCIENCE↗

Imaging Polarity in Two Dimensional Materials by Breaking Friedel's Law

Friedel's law guarantees an inversion-symmetric diffraction pattern for thin, light materials where a kinematic approximation or a single-scattering model holds. Typically, breaking Friedel symmetry is ascribed to multiple scattering events within thick, non-centrosymmetric crystals. However, two-dimensional (2D) materials such as a single monolayer of MoS 2 can also violate Friedel's law, with unexpected contrast between conjugate Bragg peaks. Here, we show analytically that retaining higher order terms in the power series expansion of the scattered wavefunction can describe the anomalous contrast between hkl and $\bar{hkl}$ peaks that occurs in 2D crystals with broken in-plane inversion symmetry. These higher-order terms describe multiple scattering paths starting from the same atom in an atomically thin material. Furthermore, 2D materials containing heavy elements, such as WS 2 , always act as strong phase objects, violating Friedel's law no matter how high the energy of the incident electron beam. Experimentally, this understanding can enhance diffraction-based techniques to provide rapid imaging of polarity, twin domains, in-plane rotations, or other polar textures in 2D materials.

2D materials↗

Multibeam Electron Diffraction

One of the primary uses for transmission electron microscopy (TEM) is to measure diffraction pattern images in order to determine a crystal structure and orientation. In nanobeam electron diffraction (NBED), we scan a moderately converged electron probe over the sample to acquire thousands or even millions of sequential diffraction images, a technique that is especially appropriate for polycrystalline samples. However, due to the large Ewald sphere of TEM, excitation of Bragg peaks can be extremely sensitive to sample tilt, varying strongly for even a few degrees of sample tilt for crystalline samples. In this paper, we present multibeam electron diffraction (MBED), where multiple probe-forming apertures are used to create multiple scanning transmission electron microscopy (STEM) probes, all of which interact with the sample simultaneously. We detail designs for MBED experiments, and a method for using a focused ion beam to produce MBED apertures. We show the efficacy of the MBED technique for crystalline orientation mapping using both simulations and proof-of-principle experiments. We also show how the angular information in MBED can be used to perform 3D tomographic reconstruction of samples without needing to tilt or scan the sample multiple times. Finally, we also discuss future opportunities for the MBED method.

47 OTHER INSTRUMENTATION↗