Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Beamline IDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Photon beamline frontends for the PETRA III extension project

The photon beamline frontend design for the new insertion device (ID) beamlines of the PETRA III extension project will be presented. The design is based on the concepts developed for the photon beamline frontends at PETRA III. This generic design approach minimized the number of specialized components for all beamlines. The girder concept with kinematic mounts at each girder allowed a fast and reliable installation phase. The extension beamlines are located in two new additional buildings. There will be 4 sectors with two undulator IDs in each sector with a canting angle of 20 mrad between the insertion devices. Additionally, two straight sections and a bending magnet chamber will be modified: one straight section will be transformed to a side station sector, the straight section with the 40 m long damping wiggler will be used as a hard X-ray source, and the bending magnet will serve as a soft-X-ray source.

43 PARTICLE ACCELERATORS↗

Focusing a round coherent beam by spatial filtering the horizontal source

This paper illustrates the use of spatial filtering with a horizontal slit near the source to enlarge the horizontal coherence in an experimental station and produce a diffraction-limited round focus at an insertion device beamline for X-ray photon correlation spectroscopy experiments. Simple expressions are provided to guide the optical layout, and wave propagation simulations confirm their applicability. The two-dimensional focusing performance of Be compound refractive lenses to produce a round diffraction-limited focus at 11 keV capable of generating a high-contrast speckle pattern of an aerogel sample is demonstrated. The coherent scattering patterns have comparable speckle sizes in both horizontal and vertical directions. The focal spot sizes are consistent with hybrid ray-tracing calculations. Producing a two-dimensional focus on the sample can be helpful to resolve speckle patterns with modern pixel array detectors with high visibility. This scheme has now been in use since 2019 for the 8-ID beamline at the Advanced Photon Source, sharing the undulator beam with two separate beamlines, 8-ID-E and 8-ID-I at 7.35 keV, with increased partially coherent flux, reduced horizontal spot sizes on samples, and good speckle contrast.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FY26 Progress Report on the Operation of the Activated Materials Laboratory at the Advanced Photon Source as a Nuclear Science User Facilities Partner Facility

The Activated Materials Laboratory (AML), located in the Long Beamline Building of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL), provides a centralized radiological capability for preparing, handling, and supporting synchrotron experiments on activated materials. As a Nuclear Science User Facilities (NSUF) partner facility, the AML enables the receipt of radioactive shipments, open-form sample handling, encapsulation, transport of specimens to and from APS beamlines, and experimentation with dedicated equipment. The partnership includes the APS 1-ID and 20-ID beamlines, which provide high-energy x-ray scattering, tomography, and diffraction microscopy techniques for ex-situ, in-situ, and grainresolved three-dimensional (3D) characterization. All samples supported through the AML and partner beamlines must meet radiological limits of less than 100 mrem/h at 30 cm. This FY26 progress report summarizes the first full year of AML operations as an NSUF partner facility and highlights progress in both user support and capability development. By the end of FY26, the AML had received a total of 10 NSUF-awarded projects, including 2 Consolidated Innovative Nuclear Research (CINR), 7 Rapid Turnaround Experiment (RTE), and 1 Super RTE projects. Beamtime was fully delivered for 3 RTE projects and partially delivered for 1 CINR project, demonstrating successful workflows for receipt, encapsulation, beamline transfer, and radiological experiment execution. These efforts demonstrated safe radiological experiments at APS beamlines for samples with dose rates above the historical 5 mrem/h threshold and now up to 100 mrem/h at 30 cm, marking an important milestone for neutron-irradiated materials research. During FY26, the AML also expanded its experimental capabilities. A Psylotech xTS load frame with in-grip rotation was deployed for room-temperature mechanical testing with threedimensional x-ray characterization during interrupted loading. A Linkam TS1500V vacuum heater was commissioned for thermally driven studies, and temperature calibration experiments were performed to establish specimen-relevant thermal profiles. In parallel, a customized split-tube furnace for high-temperature mechanical testing entered commissioning, and initial work began on robotic sample handling to reduce worker dose and improve operational efficiency. Data workflow and beamline operations continued to mature. Together, these developments demonstrate that the AML is becoming a unique national resource for safe, efficient, and scientifically advanced characterization of activated materials at the APS.

Zhang, Xuan↗

Properties of the insertion devices for PETRA III and its extension

DESY presently operates 14 independent insertion device (ID) beamlines at its 6 GeV storage ring PETRA III. Besides the 2 m long standard undulators U29 and U32, several special IDs of up to 5 m length have been installed to meet the experimental requests for high energy X-rays, elliptically polarized light, and a higher degree of coherence. Two additional half octants of the ring have recently been reconstructed, in order to extend the experimental capabilities at PETRA III. The straight sections also allow for installation of IDs of 2 m or 5 m length. This article gives an overview of the ID key parameters, the spectral properties and the brilliance of the current undulators installed at PETRA III. It also presents the characteristics of some of the upcoming special IDs, like in-vacuum and short undulators.

43 PARTICLE ACCELERATORS↗

Beamline XPD (28-ID, DW 100) Commissioning Radiation Survey Report

A radiological survey of the Beamline XPD (28ID, Damping Wiggler) was conducted on February 19, 2015 between 0030 and 0320 in accordance with the Beamline XPD (28-ID) Radiation Survey Plan [1]. This comprehensive survey was limited in scope because the FE slits were not fully open and the filters were not ALL out.

36 MATERIALS SCIENCE↗

Possibility of splitting APS dipoles to make more ID straights.

Recently we were asked by Ercan Alp if it would be possible to use three dipoles in an APS sector to make a second ID beamline possible, much as was done for the APSx3 design. We've looked at this to see what might be possible without making too many changes to the ring. Ideally, we'd like to simply replace the one dipole with two shorter dipoles with an insertion device in the middle. Of course, we'd like to make the ID as long as possible, subject to limits on dipole strength, accelerator optics, and emittance. We used elegant [3] to match an insertion device consisting of two sectors. The second (BM) dipole of the first sector was split at the 1/8th point in terms of both angle and length. A zero length drift space was inserted that could then be stretched to create room for an ID. To simplify matters somewhat at this stage, we constrained the length of the two dipoles plus the drift to equal the original dipole length. I.e., we ignored for now the difference between arc and straight length. Our desire is to make the drift space as long as possible. If we limit the dipole field B to 2T, then the total length of the dipoles must be greater than L{sub min} = H{theta}/B, where H = 23.35Tm is the rigidity and {theta} = {pi}/40-0.001 is the total angle. L{sub min} is therefore 0.91 m, and hence the drift space can at most be 2.15 m. At least one, perhaps both, of the short dipoles will end up in a high-dispersion region, which will lead to emittance growth. Hence, we didn't want to drive the length too far and decided to limit it to 2 m, approximately the same as in the APSx3 lattice. Hence, as in that lattice we should be able to accommodate a 1-m-long insertion device. In addition to stretching the drift space, we allowed all twenty quadrupoles in the sectors to vary. Initial constraints included less than 20% deviation in lattice functions at the middle ID straight and less than 0.001% deviation in the final ID straight (to get a good match to the rest of the ring). We found the dispersion slope at the middle ID was quite hard to match, and made this a relatively loose constraint. We also had to increase the tolerance on changes in the horizontal beta function at the middle ID from 20 to 30%. A constraint was also placed on the effective emittance to make it as small as possible. Figure 1 shows the lattice functions for the two sectors. The magnet-to-magnet distance between the split dipoles is 1.97 m, slightly short of the 2 m mark. The first dipole is 0.17 m long with a field of 1.35 T, while the second dipole is 0.92 m long with a field of 1.73 T. The effective emittance assuming we formed a ring from such sectors is 4.95 nm. Hence, if we add N such modules to a ring with all other sectors being normal (3.13 nm effective emittance), the expected emittance is 9.9N + (40-2N)3.13/40 (1). If we want to limit the emittance to 10% more than the nominal 3.13 nm, we need N < 4. If we limit it to under 4 nm (ESRF's emittance), then we have N < 10. Table 1 lists parameters of the new source point, assuming that we insert three such modules in the ring (N = 3) and that we have a 1.5% ratio of the raw emittances. We attempted to improve the emittance and matching by allowing a gradient in the dipoles, thinking that perhaps it would provide additional optics flexibility. However, no improvement was obtained.

43 PARTICLE ACCELERATORS↗

Far-Field High-Energy Diffraction Microscopy: A Non-Destructive Tool for Characterizing the Microstructure and Micromechanical State of Polycrystalline Materials

A suite of non-destructive, three-dimensional X-ray microscopy techniques have recently been developed and used to characterize the microstructures of polycrystalline materials. These techniques utilize high-energy synchrotron radiation and include near-field and far-field diffraction microscopy (NF- and FF-HEDM, respectively) and absorption tomography. Several compatible sample environments have also been developed, enabling a wide range of 3D studies of material evolution. In this article, the FF-HEDM technique is described in detail, including its implementation at the 1-ID beamline of the Advanced Photon Source. Examples of how the information obtained from FF-HEDM can be used to deepen our understanding of structure-property-processing relationships in selected materials are presented.

36 MATERIALS SCIENCE↗

Label-based Virtual Directories In dCache

Traditional filesystems organize data in directories. These directories are typically a collection of files whose grouping is based on a single criterion, e.g., the starting date of an experiment, experiment name, beamline ID, measurement device, or instrument. However, each file in a directory can belong to several logical groups, such as a special event type, experiment condition, or a part of a selected dataset. dCache is a storage system developed to store large amounts of scientific data, used by many HEP and Photon Science experiments. With recent developments in dCache, we have introduced a concept of file tagging, which dynamically groups files with the same label into virtual directories. The file labels can be added, removed, renamed, and deleted through the admin interface or via REST API. The files in virtual directories are exposed through all protocols supported by dCache. This contribution will describe the details of the implementation for file tagging in dCache and present our future development plans on automatic metadata extractions, a feature that will significantly simplify data management. Additionally, we are exploring the future use of virtual directories as a way to translate scientific data catalogs into filesystem views for direct data analysis.

Sahakyan, Marina [DESY]↗

Development and Performance of Superconducting Undulators at the Advanced Photon Source

Several years ago, an article in SRN [1] with the same title as this article summarized the decade-long development of superconducting undulators (SCUs) at the Advanced Photon Source (APS). The article presented those developments leading to the point when the first prototype, called SCU0 and intended for installation at the APS, was under fabrication. SCU0 was built in 2012, its cryogenic performance has been extensively tested, and detailed magnet measurements of the device have been conducted. After verification that SCU0 met all of the technical requirements for APS insertion devices, it was installed in the APS storage ring in January 2013, commissioned in a record short time (two weeks), and became a routinely used source of hard X-rays at the APS Sector 6 ID beamline.

Gluskin, Efim↗

Sample-minimizing co-flow cell for time-resolved pump–probe X-ray solution scattering

A fundamental problem in biological sciences is understanding how macromolecular machines work and how the structural changes of a molecule are connected to its function. Time-resolved techniques are vital in this regard and essential for understanding the structural dynamics of biomolecules. Time-resolved small- and wide-angle X-ray solution scattering has the capability to provide a multitude of information about the kinetics and global structural changes of molecules under their physiological conditions. However, standard protocols for such time-resolved measurements often require significant amounts of sample, which frequently render time-resolved measurements impossible. A cytometry-type sheath co-flow cell, developed at the BioCARS 14-ID beamline at the Advanced Photon Source, USA, allows time-resolved pump–probe X-ray solution scattering measurements to be conducted with sample consumption reduced by more than ten times compared with standard sample cells and protocols. The comparative capabilities of the standard and co-flow experimental setups were demonstrated by studying time-resolved signals in photoactive yellow protein.

36 MATERIALS SCIENCE↗

X-ray Measurements of Fuel Spray Specific Surface Area and Sauter Mean Diameter for Cavitating and Non-Cavitating Diesel Sprays

Specific surface area measurements of diesel sprays were performed using ultra-small-angle x-ray scattering at the 9-ID beamline of the Advanced Photon Source at Argonne National Laboratory. Injector orifice type, rail pressure, and ambient pressure effects were explored. The targeted sprays were created by three different single-hole nozzles fitted with duplicate light-duty common rail diesel injector bodies. One of the nozzles has been designed to cavitate under typical diesel operating conditions, while the other two nozzles are its non-cavitating analogues with nominally identical geometries. Measurements were conducted in the near-nozzle region along the spray axis as well as across the width of the jet. These data provide information with regard to not only the rate of shear-driven atomization, but also the radial dispersion of the fuel droplets at each of the measured conditions. In addition, when coupled with complementary measurements of the projected density, the data quantify the Sauter mean diameter of the fuel droplets in the probe volume. Here, these specific surface area and Sauter mean diameter measurements can be used to inform computational models of spray breakup that rely on droplet information in the near-nozzle region, where optical diagnostics have proven challenging.

47 OTHER INSTRUMENTATION↗

Mechanical Properties and Deformation Behavior of Additively Manufactured 316L Stainless Steel (FY2020)

The Transformational Challenge Reactor (TCR) program plans to build most of the TCR core components through additive manufacturing (AM) processes. These processes include laser powder bed fusion (LPBF) for the metallic (316L) components and the newly developed combined process of binderjet printing and chemical vapor infiltration (CVI) for the SiC fuel matrix. Mechanical testing and characterization tasks have been carried out since the beginning of the TCR program to (1) build a property database for the AM materials that will be used in TCR core and (2) to assess the materials’ performance in TCR-relevant conditions. This document reports the outcome of the testing and characterization efforts for the fiscal year with a focus on the mechanical performance data of AM 316L stainless steel (SS). Baseline tensile testing over a wide temperature range of room temperature–600 °C was completed for the AM 316L alloy in as-built, stress-relieved, and solution-annealed conditions. The as-built 316L showed the highest strength, and the alloy after the post-build treatments showed reduced strengths in the low-strain range. However, the strength differences among the AM materials became insignificant in the later part of deformation. Furthermore, regardless of post-build processing, the AM 316L SS showed higher strength and comparable ductility when compared with wrought 316L SS. Thermal creep testing and microstructural evolution during creep deformation were also performed under selected conditions. It was found that the AM 316L steel showed the best creep resistance in the stress-relieved condition. In-situ tensile tests were performed using scanning electron microscopy and 1-ID beamline at the Advanced Photon Source to elucidate the deformation and fracture behavior of AM 316L and the evolution of crystalline stress, dislocations, and pore distribution. Using these in-situ testing data, an in-depth analysis of the roles of microstructural features in deformation and fracture processes is presented herein. The final section of the document introduces ongoing and future activities for materials testing and characterization, including irradiation effect studies and ball punch testing on AM 316L and AM IN718 alloys.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Power density calculation of spontaneous radiation emission from a finite emittance electron beam in planar undulators

We extend the angular power density formulae for spontaneous radiation emission from planar undulators to include finite emittance and angular misalignment of the electron beam. Then we calculate and compare power densities estimated from integral approach with Gaussian beam distribution and summation approach with macro-particle allocation covering particle beam phase space. After showing that both approaches converge to each other, we apply the macro-particle approach to study power absorbed and transmitted by various apertures at front end of 9-ID beamline at National Synchrotron Light Source-II for misaligned electron beam. Our analysis indicate that the electron beam misalignment could lead to unwarranted power deposition at tighter apertures that would have been otherwise difficult to account for during the aperture design/choice process.

43 PARTICLE ACCELERATORS↗

High-Energy X-ray Studies of Real Materials Under Real Conditions and in Real Time

High-energy x-rays from 3rd generation synchrotron sources, including the APS, possess a unique combination of high penetration power and high spatial, reciprocal space, and temporal resolution. These characteristics can be exploited to non-destructively measure phase, texture and strain distributions under extreme environments including thermo-mechanical loading, high-pressure, irradiation and supercritical environments. Over the past several years, the 1-ID beamline has developed a number of programs for these purposes, namely (i) high-energy diffraction microscopy, in which grain and sub-grain volumes are mapped in polycrystalline aggregates, and (ii) combined small-and wide-angle x-ray scattering which permits information over a broad range of length scales to be collected from the same (micron-level) volume. These programs have been increasingly used to test and extend predictive simulations of materials behavior over size scales ranging from nm to mm. Select studies will be presented including nucleation and growth of nanomaterials, void and structural evolution in complex composites under thermo-mechanical and irradiated environments, and microstructural changes in layered systems including thermal-barrier coatings, batteries and fuel cells. Finally, extension of these programs, through the planned APS upgrade, to higher spatio-temporal resolution will be described.

36 MATERIALS SCIENCE↗

Mechanical Design Progress of the In Situ Nanoprobe Instrument for APS-U

The In Situ Nanoprobe (ISN, 19-ID) beamline will be a new best-in-class long beamline to be constructed as part of the Advanced Photon Source Upgrade (APS-U) project [1, 2]. To achieve long working distance at high spatial resolution, the ISN instrument will be positioned 210 m downstream of the x-ray source, in a dedicated satellite building, currently under construction [3]. The ISN instrument will use a nano-focusing Kirkpatrick-Baez (K-B) mirror system, which will focus hard x-rays to a focal spot as small as 20 nm, with a large working distance of 61 mm. The large working distance provides space for various in situ sample cells for x-ray fluorescence tomography and ptychographic 3D imaging, allows the use of a separate, independent vacuum chambers for the optics and sample, and provides the flexibility to run experiments in vacuum or at ambient pressure. A consequence of the small spot size and large working distance are stringent requirements for high angular stability of the K-B mirrors (5 nrad V-mirror and 16 nrad H-mirror) and high relative stability be-tween focus spot and sample (4 nmRMS). Additional features include fly-scanning up to 2 kg mass, sample plus in situ cell, at 1 mm/s in vertical and/or horizontal directions over an area of 10 mm x 10 mm. Environmental capabili-ties will include heating and cooling, flow of fluids and applied fields, as required for electrochemistry and flow of gases at high temperature for catalysis. To achieve these capabilities and precise requirements we have used precision engineering fundamentals to guide the design process.

Kearney, Steven P.↗

Etched Silicon Planar CRL Optics for the High-Energy X-ray Diffraction Beamlines 11-ID-B and 11-ID-C at the APS

We report the focusing of high-energy X-rays is most commonly achieved by commercially available compound refractive lenses (CRL), which are added together in larger structures. There is a need for high-energy X-ray beamlines to enable focusing in only one dimension down to a few micrometers to study layered materials and thin films. High-energy X-rays above 50 keV require often 100 lenses or more, therefore it is more efficient to etch the complete arrays of lenses into a monolithic substrate like a silicon wafer. Custom lens arrays were fabricated for the high-energy x-ray beamlines 11-ID-B, and 11-ID-C at the Argonne National Laboratory. The fabrication required tuning parameters of the Bosch process to optimize the etching of deep vertical sidewalls at a reasonable speed without overheating. The beamline 11-ID-B is equipped with lens arrays of 85-110 lenses for 59 keV and 190-250 lenses for 87 keV photon energy, focusing the beam vertically below 5.0 µm at the sample positions between 1600 mm to 2100 mm. 11-ID-C has received arrays of 435 lenses that focus 106 keV X-rays to a vertical height of 2.0 µm at the sample position. In both cases, the flux density gain in the focal spot is larger than a factor of 20, relative to using slits to cut the beam size. The lens setup is permanently installed and can be moved in and out of the beam during the experiment without further alignment. The lenses have enabled operando diffraction studies on interfaces in batteries and the development of pair distribution function (PDF) analysis using grazing incidence geometry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reduction and Agglomeration of Supported Metal Clusters Induced by High-Flux X-ray Absorption Spectroscopy Measurements

Supported metal clusters are widely used in catalysis for many important reactions. To understand the catalytic properties, in situ/operando characterization techniques, such as X-ray absorption spectroscopy (XAS), provide essential details of the size, shape, and chemical composition of the cluster and the nature of the active sites. New-generation synchrotrons combined with focusing beamlines provide high-flux-density X-rays for improved detection sensitivity as well as higher time and spatial resolution. Understanding the effects of a high-flux-density X-ray beam on the catalyst during the actual measurement, whether XAS or another synchrotron-based technique, is crucial. This is especially important for in situ and operando studies where both the high flux density and reaction conditions can affect the catalyst structure. In this work, we investigated the effect of the flux density on rhodium clusters supported on Al 2 O 3 at two different beamlines: National Synchrotron Light Source II beamline 08-ID and Stanford Synchrotron Radiation Light Source (SSRL) beamline 4-1. We show that the higher flux density at beamline 08-ID causes the reduction of the highly dispersed RhO x /Al 2 O 3 catalyst, even at room temperature. Additionally, exposure to the higher flux density X-rays at beamline 08-ID during in situ reduction results in significant agglomeration of the Rh clusters. The final size of the Rh nanoparticles reduced at 310 °C is equivalent to that of particles formed after the reduction at 600–650 °C in the absence of the beam. Significant beam-induced reduction and agglomeration is also shown for Ni supported on beta zeolite during in situ reduction at an intermediate-flux-density beamline 9-3 at SSRL, indicating that beam-induced changes in heterogeneous catalysts could be common at intermediate- and high-flux-density beamlines. We provide precautions and recommendations for detecting and minimizing beam damage during in situ/operando XAS measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗