Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Baseline”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Baseline Calibration of the GeoSAR Interferometric Mapping Instrument

GeoSAR is a dual frequency, X-Band and P-Band, interferometric mapping radar flown on a Gulfstream II with a nominal flying altitude of 10000 and a swath width of 10 km on both left and right sides of the aircraft. The radar is designed to generate high resolution and high accuracy digital elevation maps both above and below the vegetation canopy. In order to generate the high accuracy digital elevations models it is necessary to have extremely precise knowledge of the interferometric baseline, approximately .1 mm for the X-band system and 3 mm for the P-band system. Baseline knowledge to this level of accuracy is achieved through a combination of active baseline measurement using a Laser Baseline Metrology System (LBMS) and baseline calibration using an accurately surveyed array of corner reflectors. In this paper, we describe the LBMS system used to measure the dynamic component of the interferometric baseline and the least squares procedure used to estimate all three components of the interferometric baseline based on differences between calculated and surveyed corner reflector locations.

Hensley, Scott↗

Testing Explanations of Short Baseline Neutrino Anomalies

The experimental observation of neutrino oscillations profoundly impacted the physics of neutrinos, from being well understood theoretically to requiring new physics beyond the standard model of particle physics. Indeed, the mystery of neutrino masses implies the presence of new particles never observed before, often called sterile neutrinos, as they would not undergo standard weak interactions. And while neutrino oscillation measurements entered the precision era, reaching percent-level precision, many experimental results show significant discrepancies with the standard model, at baselines much shorter than typical oscillation baselines, like LSND, MiniBooNE, gallium experiments, and reactor antineutrino measurements. These short baseline anomalies could be explained by the addition of a light sterile neutrino, with mass in the $1-10~\text{eV}$ range, however, in strong tension with many null experimental observations. Other explanations that rely on sterile neutrinos with masses in the $1-500~\text{MeV}$ could resolve the tension. Here we test both classes of models. On the one hand, we look for datasets collected at a short baseline which can constrain heavy sterile neutrino models. We find that the minimal model is fully constrained, but several extensions of this model could weaken the current constraint and be tested with current and future datasets. On the other hand, we test the presence of neutrino oscillations at short baselines, induced by a light sterile state, with the data collected by the MicroBooNE experiment, a liquid argon time projection chamber specifically designed to resolve the details of each neutrino interaction. We report null results from both analyses, further constraining the space of possible explanations for the short baseline anomalies. If new physics lies behind the short baseline anomaly puzzle, it is definitely not described by a simple model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving the accuracy of energy baseline models for commercial buildings with occupancy data

More than 80% of energy is consumed during operation phase of a building's life cycle, so energy efficiency retrofit for existing buildings is considered a promising way to reduce energy use in buildings. The investment strategies of retrofit depend on the ability to quantify energy savings by “measurement and verification” (M&V), which compares actual energy consumption to how much energy would have been used without retrofit (called the “baseline” of energy use). Although numerous models exist for predicting baseline of energy use, a critical limitation is that occupancy has not been included as a variable. However, occupancy rate is essential for energy consumption and was emphasized by previous studies. This study develops a new baseline model which is built upon the Lawrence Berkeley National Laboratory (LBNL) model but includes the use of building occupancy data. The study also proposes metrics to quantify the accuracy of prediction and the impacts of variables. However, the results show that including occupancy data does not significantly improve the accuracy of the baseline model, especially for HVAC load. The reasons are discussed further. In addition, sensitivity analysis is conducted to show the influence of parameters in baseline models. To conclude, the results from this study can help us understand the influence of occupancy on energy use, improve energy baseline prediction by including the occupancy factor, reduce risks of M&V and facilitate investment strategies of energy efficiency retrofit.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Using Visual Systems Mapping to Improve Transparency and Comparability of Life Cycle Assessment Baseline Scenarios

Visual systems mapping is a systems engineering approach used to represent complex processes and interactions. This study evaluates its application for documenting assumptions in life cycle assessment (LCA) baseline scenarios. In LCA, the baseline or reference case represents the business as usual system against which changes in impacts (e.g., emissions) are assessed. These baseline assumptions are particularly influential in biomass LCAs, yet they often vary across studies due to regional context, system boundaries, and simplifying assumptions that are not consistently or transparently documented. As a result, key feedbacks, omitted processes, and boundary choices may remain unclear, limiting comparability across studies and weakening their usefulness for decision-making. This study examines whether visual systems mapping can improve the transparency and comparability of biomass LCA baseline scenarios. A case study of five published biomass-related LCAs were reviewed, and their baseline scenarios were translated into visual system maps to identify included processes, omitted components, and underlying assumptions. The analysis demonstrates that visual systems mapping can make baseline assumptions more explicit, highlight excluded dynamics, and improve documentation of system boundaries. Based on these findings, the study recommends the use of visual systems mapping alongside open data repositories and reproducible workflows to support greater transparency, reproducibility, and comparability in LCAs. These improvements can strengthen the role of LCAs in informing decisions related to sustainable biomass systems.

Davis, Maggie [ORNL] (ORCID:0000000181319328)↗

Prognosticating Survival in Hepatocellular Carcinoma with Elevated Baseline Alpha-fetoprotein Treated with Radioembolization Using a Novel Laboratory Scoring System: Initial Development and Validation

Aims: To investigate laboratory parameters as predictors of overall survival (OS) for hepatocellular carcinoma (HCC) treated with radioembolization and develop/validate a scoring system. Methods: With IRB approval, we included all patients with baseline alpha-fetoprotein (AFP) > 100 ng/dL from our prospectively acquired HCC radioembolization database. Neutrophil–lymphocyte ratio, albumin–bilirubin (ALBI), and AFP were measured at baseline and at 1-, 3-, and 6-month post-radioembolization Landmarks. OS was assessed from these Landmarks. Univariate/multivariate analyses were performed to evaluate OS predictability of these parameters. Baseline Imaging, Laboratory, and Combination scoring systems were developed. Developing/validating groups were created to investigate/validate the score’s OS predictability. Time-dependent receiver operating characteristics (ROC) were evaluated. Patients were stratified into groups I, II, and III by using 25th and 75th percentile cutoffs according to change in Laboratory Score from baseline. Results: 345/401 (86%), 238/401 (59%), and 167/401 (42%) patients had laboratory parameters available at the 1-, 3-, and 6-month Landmarks, respectively. ALBI and AFP were significant OS prognosticators at all Landmarks. The Laboratory Score [ALBI + (0.3 × LnAFP)] was developed/internally validated to predict OS from these Landmarks. Areas under the curve of time-dependent ROCs of the Baseline Imaging vs. Laboratory scores in predicting patient OS post 3 and 6 months Landmarks were 0.56 versus 0.82 and 0.57 versus 0.77, respectively. OS differences in groups I, II, and III according to change in Laboratory Score from baseline were significant (p < 0.001). Conclusions: Post-radioembolization AFP and ALBI scores were significant OS prognosticators. A decrease in post-therapeutic Laboratory Score, which combines AFP and ALBI, correlates with an improved OS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intrafractional Baseline Shift or Drift of Lung Tumor Motion During Gated Radiation Therapy With a Real-Time Tumor-Tracking System

Purpose: To investigate the frequency and amplitude of baseline shift or drift (shift/drift) of lung tumors in stereotactic body radiation therapy (SBRT), using a real-time tumor-tracking radiation therapy (RTRT) system. Methods and Materials: Sixty-eight patients with peripheral lung tumors were treated with SBRT using the RTRT system. One of the fiducial markers implanted near the tumor was used for the real-time monitoring of the intrafractional tumor motion every 0.033 seconds by the RTRT system. When baseline shift/drift is determined by the system, the position of the treatment couch is adjusted to compensate for the shift/drift. Therefore, the changes in the couch position correspond to the baseline shift/drift in the tumor motion. The frequency and amount of adjustment to the couch positions in the left-right (LR), cranio-caudal (CC), and antero-posterior (AP) directions have been analyzed for 335 fractions administered to 68 patients. Results: The average change in position of the treatment couch during the treatment time was 0.45 ± 2.23 mm (mean ± standard deviation), −1.65 ± 5.95 mm, and 1.50 ± 2.54 mm in the LR, CC, and AP directions, respectively. Overall the baseline shift/drift occurs toward the cranial and posterior directions. The incidence of baseline shift/drift exceeding 3 mm was 6.0%, 15.5%, 14.0%, and 42.1% for the LR, CC, AP, and for the square-root of sum of 3 directions, respectively, within 10 minutes of the start of treatment, and 23.0%, 37.6%, 32.5%, and 71.6% within 30 minutes. Conclusions: Real-time monitoring and frequent adjustments of the couch position and/or adding appropriate margins are suggested to be essential to compensate for possible underdosages due to baseline shift/drift in SBRT for lung cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE 2014 ALMA LONG BASELINE CAMPAIGN: AN OVERVIEW

A major goal of the Atacama Large Millimeter/submillimeter Array (ALMA) is to make accurate images with resolutions of tens of milliarcseconds, which at submillimeter (submm) wavelengths requires baselines up to ∼15 km. To develop and test this capability, a Long Baseline Campaign (LBC) was carried out from 2014 September to late November, culminating in end-to-end observations, calibrations, and imaging of selected Science Verification (SV) targets. This paper presents an overview of the campaign and its main results, including an investigation of the short-term coherence properties and systematic phase errors over the long baselines at the ALMA site, a summary of the SV targets and observations, and recommendations for science observing strategies at long baselines. Deep ALMA images of the quasar 3C 138 at 97 and 241 GHz are also compared to VLA 43 GHz results, demonstrating an agreement at a level of a few percent. As a result of the extensive program of LBC testing, the highly successful SV imaging at long baselines achieved angular resolutions as fine as 19 mas at ∼350 GHz. Observing with ALMA on baselines of up to 15 km is now possible, and opens up new parameter space for submm astronomy.

79 ASTRONOMY AND ASTROPHYSICS↗

Coriolis force compensation and laser beam delivery for 100-m baseline atom interferometry

The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry, which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.

Glick, Jonah↗

Baseline [ 18 F]GTP1 tau PET imaging is associated with subsequent cognitive decline in Alzheimer’s disease

Background: The role and implementation of tau PET imaging for predicting subsequent cognitive decline in Alzheimer’s disease (AD) remains uncertain. This study was designed to evaluate the relationship between baseline [ 18 F]GTP1 tau PET and subsequent longitudinal change across multiple cognitive measures over 18 months. Methods: Our analyses incorporated data from 67 participants, including cognitively normal controls (n = 10) and β-amyloid (Aβ)-positive individuals ([ 18 F] florbetapir Aβ PET) with prodromal (n = 26), mild (n = 16), or moderate (n = 15) AD. Baseline measurements included cortical volume (MRI), tau burden ([ 18 F]GTP1 tau PET), and cognitive assessments [Mini-Mental State Examination (MMSE), Clinical Dementia Rating (CDR), 13-item version of the Alzheimer’s Disease Assessment Scale-Cognitive Subscale (ADAS-Cog13), and Repeatable Battery for the Assessment of Neuropsychological Status (RBANS)]. Cognitive assessments were repeated at 6-month intervals over an 18-month period. Associations between baseline [ 18 F]GTP1 tau PET indices and longitudinal cognitive performance were assessed via univariate (Spearman correlations) and multivariate (linear mixed effects models) approaches. The utility of potential prognostic tau PET cut points was assessed with ROC curves. Results: Univariate analyses indicated that greater baseline [ 18 F]GTP1 tau PET signal was associated with faster rates of subsequent decline on the MMSE, CDR, and ADAS-Cog13 across regions of interest (ROIs). In multivariate analyses adjusted for baseline age, cognitive performance, cortical volume, and Aβ PET SUVR, the prognostic performance of [ 18 F]GTP1 SUVR was most robust in the whole cortical gray ROI. When AD participants were dichotomized into low versus high tau subgroups based on baseline [ 18 F]GTP1 PET standardized uptake value ratios (SUVR) in the temporal (cutoff = 1.325) or whole cortical gray (cutoff = 1.245) ROIs, high tau subgroups demonstrated significantly more decline on the MMSE, CDR, and ADAS-Cog13. Conclusions: Our results suggest that [ 18 F]GTP1 tau PET represents a prognostic biomarker in AD and are consistent with data from other tau PET tracers. Tau PET imaging may have utility for identifying AD patients at risk for more rapid cognitive decline and for stratification and/or enrichment of participant selection in AD clinical trials.

60 APPLIED LIFE SCIENCES↗

An approach to software baseline generation

A current Data & Analysis Center for Software (DACS) effort to develop software baselines is summarized. This baseline effort is an on-going activity; that is, the baselines are meant to be updated as new software data becomes available. The information presented and processed was organized to make periodic updating a much simpler task. A baseline, for this effort, consists of an estimation of any characteristic of a software project that is helpful to a developer, manager, or monitor to manage, control, or influence a software product. The objective of these baselines is to provide a tool for aiding software developers in their daily work. Baselines were synthesized from an empirical dataset provided by the Software Engineering Laboratory at NASA Goddard Space Flight Center (NASA/SEL). These data were selected because the data collection effort developed at the NASA/SEL is the most thorough and complete available.

Romeu, J. L.↗

Angular navigation capabilities of short baseline phase delay interferometry

Short baseline phase delay interferometry can provide angular navigation capabilities which are competitive with current accuracies for group delay Very Long Baseline Interferometry (VLBI) on intercontinental baselines. In addition, a number of operational considerations make short baseline interferometry attractive, including enhanced mutual visibility, ability to observe at higher elevation angles, and the possibility of processing data in realtime. To make use of the higher precision phase delay datatype, however, the cycle ambiguity associated with the observed interferometric phase must be resolved. Results are presented for two experiments, on baselines of 5.9 and 253 km, for which RF phase connection appears to have been reliably achieved for several groups of angularly close radio sources. The dependence of the resulting phase delay residuals on elevation suggests that temporal fluctuations in the line-of-sight troposphere delay are a dominant error source. The observed RMS phase delay residuals of 10 psec or less suggest that baselines of order 100 km could provide high-efficiency angular navigation with accuracies well below 50 nrad. Plans for further work at the Goldstone Deep Space Communication Complex are reviewed.

Edwards, C. D.↗

Carrier phase ambiguity resolution for the Global Positioning System applied to geodetic baselines up to 2000 km

A technique for resolving the ambiguities in the GPS carrier phase data (which are biased by an integer number of cycles) is described which can be applied to geodetic baselines up to 2000 km in length and can be used with dual-frequency P code receivers. The results of such application demonstrated that a factor of 3 improvement in baseline accuracy could be obtained, giving centimeter-level agreement with coordinates inferred by very-long-baseline interferometry in the western United States. It was found that a method using pseudorange data is more reliable than one using ionospheric constraints for baselines longer than 200 km. It is recommended that future GPS networks have a wide spectrum of baseline lengths (ranging from baselines shorter than 100 km to those longer than 1000 km) and that GPS receivers be used which can acquire dual-frequency P code data.

Blewitt, Geoffrey↗

Information content of a single pass of phase-delay data from a short baseline connected element interferometer

An analytic development of the information array obtained with a single tracking pass of phase-delay measurements made from a short baseline interferometer is presented. Phase-delay observations can be made with great precision from two antennas using a single, common distributed frequency standard, hence the name connected element. With the information array, closed-form expressions are developed for the error covariance in declination and right ascension. These equations serve as useful tools for analyzing the relative merits of candidate station locations for connected element interferometry (CEI). The navigation performance of a short baseline interferometer located at the Deep Space Network's (DSN's) Goldstone intracomplex is compared with that which is presently achievable using Very Long Baseline Interferometry (VLBI) over intercontinental baselines. The performance of an intracomplex pair of short baselines formed by three stations is also investigated, along with the use of a single baseline in conjunction with conventional two-way Doppler data. The phase-delay measurement accuracy and data rate used in the analysis are based on the expected performance of an experimental connected element system presently under construction at Goldstone. The results indicate that the VLBI system that will be used during the Galileo mission can determine the declination and right ascension of a distant spacecraft to an accuracy of 20 to 25 nrad, while the CEI triad system and the combination of CEI-Doppler system are both capable of 30 to 70 nrad performance.

Thurman, S. W.↗

An evaluation of water vapor radiometer data for calibration of the wet path delay in very long baseline interferometry experiments

The internal consistency of the baseline-length measurements derived from analysis of several independent VLBI experiments is an estimate of the measurement precision. The paper investigates whether the inclusion of water vapor radiometer (WVR) data as an absolute calibration of the propagation delay due to water vapor improves the precision of VLBI baseline-length measurements. The paper analyzes 28 International Radio Interferometric Surveying runs between June 1988 and January 1989; WVR measurements were made during each session. The addition of WVR data decreased the scatter of the length measurements of the baselines by 5-10 percent. The observed reduction in the scatter of the baseline lengths is less than what is expected from the behavior of the formal errors, which suggest that the baseline-length measurement precision should improve 10-20 percent if WVR data are included in the analysis. The discrepancy between the formal errors and the baseline-length results can be explained as the consequence of systematic errors in the dry-mapping function parameters, instrumental biases in the WVR and the barometer, or both.

Kuehn, C. E.↗

Baseline Medical System Translation for the Impact Medical Database

NASA has developed a new evidence-based data-driven probabilistic risk assessment and tradespace analysis tool as a successor to the Integrated Medical Model (IMM). This updated decision support tool is known as IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces). Whereas IMM focuses on the resources and risks associated with International Space Station (ISS) and Low Earth Orbit (LEO) missions, IMPACT estimates the frequency and consequences of medical conditions that might arise during exploration missions. One of the services offered by IMM is a series of generic or baseline medical systems associated with typical mission types or DRMs (Design Reference Missions), such that requestors may prioritize questions pertaining to the mission itself over the medical supplies indicated by the model outputs for that DRM. In a mission focused request, the appropriate baseline medical system is used in place of a prepared or optimized medical kit. In preparation, an effort was undertaken to create baseline systems of medical resources within IMPACT suitable for typical DRMs. Using an existing baseline medical system within IMM’s Integrated Medical Evidence Database (iMED) as a starting point, the resources found within the medical kit were compared to and substituted for equivalent resources available within the IMPACT MD (Medical Database). In consultation with clinicians with knowledge of IMPACT’s MD, each resource was matched as closely as possible to a similarly purposed resource in IMPACT, seeking to preserve the treatment capabilities and procedures offered by the IMM medical system while reconciling the differences in modeled resources and medical conditions between the models. To demonstrate the efficacy of this work, a prototype ISS medical system in IMPACT was translated from the baseline used in the IMM. The appropriate medical system was then run through its associated medical model to compare and validate the resultant risks and risk mitigation provided by each baseline ISS medical kit.

S Schwartz↗

Baseline Evaluations to Support Control Room Modernization at Nuclear Power Plants

For any major control room modernization activity at a commercial nuclear power plant (NPP) in the U.S., a utility should carefully follow the four phases prescribed by the U.S. Nuclear Regulatory Commission in NUREG-0711, Human Factors Engineering Program Review Model. These four phases include Planning and Analysis, Design, Verification and Validation, and Implementation and Operation. While NUREG-0711 is a useful guideline, it is written primarily from the perspective of regulatory review, and it therefore does not provide a nuanced account of many of the steps the utility might undertake as part of control room modernization. The guideline is largely summative—intended to catalog final products—rather than formative—intended to guide the overall modernization process. In this paper, we highlight two crucial formative sub-elements of the Planning and Analysis phase specific to control room modernization that are not covered in NUREG-0711. These two sub-elements are the usability and ergonomics baseline evaluations. A baseline evaluation entails evaluating the system as-built and currently in use. The usability baseline evaluation provides key insights into operator performance using the control system currently in place. The ergonomics baseline evaluation identifies possible deficiencies in the physical configuration of the control system. Both baseline evaluations feed into the design of the replacement system and subsequent summative benchmarking activities that help ensure that control room modernization represents a successful evolution of the control system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Baseline Graphite Characterization

Presentation will include baseline graphite characterization information, such as purpose and results, baseline property measurements, baseline graphite characterization method, baseline progress, split disc tensile strength: ASTM Tensile Strength Alternative, Identification of proper split disk fracture, baseline graphite ASTM D8289, horizontal orientation, digital image correlation, and DIC Analyzation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Language-Theoretic Data Analysis to Support ICS Protocol Baselining

Critical infrastructure stakeholders need to baseline their systems to understand expected protocol communications. Baseline behaviors may vary based on operational context. Expected operations during a maintenance window, for example, may be different from normal operations. Furthermore, constructing system baselines for Industrial Control Systems (ICS) is difficult and time-consuming. ICS processes generate artifacts expressed across heterogeneous data sources such as network traffic and device logs. This paper explores the hypothesis that such ICS artifacts form a language in the language-theoretic sense. From a theoretical perspective, the variety of implementations of ICS protocols and constrained environment of OT networks provide a rich application domain for language-theoretic approaches. We present several use cases related to the practical construction of system baselines: grammars for data fusion, language dialects for device fingerprinting, and security automata for system baselining

24 POWER TRANSMISSION AND DISTRIBUTION↗