Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

53 records · Page 3

Effects of Cage Type and NASA Rodent Food Bar in Male Sprague-Dawley Rats

Early prototype caging for the rodent Advanced Animal Habitat (P-AAH) for the International Space Station (ISS) is currently being tested. In this five week study, effects of the wire-bottom P-AAH cages and specialized NASA rodent food bars (FB) were compared to standard vivarium cages (VIV) with corn-cob, litter-filled bottoms, and standard Purina rat chow (CH). Ninety-six male Sprague-Dawley rats were divided into four treatment groups (24 rats/treatment): Group 1) VIV+CH, Group 2) P-AAH+CH, Group 3) VIV+FB, and Group 4) P-AAH+FB. Each VIV and P-AAH cage housed three and six rats, respectively. After five weeks of treatment rats were weighed, euthanized, and blood samples were collected. Weights of liver (LIV), kidney (KID), brain (BRN), epididymal fat (EPI), and perirenal fat (PERI) were also measured. Statistical analysis to compare differences between groups was performed by standard analysis of variance procedures (ANOVA) with a significance level of pLO.05. Results indicated P-AAH housed rats had significantly lower body weights (BW), LIV weights, and LIV/BW than VIV housed rats. FB fed rats had significantly lower blood urea nitrogen (BUN) levels and LIV/BW than CH fed rats. In addition, FB fed rats had significantly higher cholesterol (CHOL) levels, EPI/BW, PERI/BW, and total fat (EPI+PERI)/BW than CH fed rats. The P-AAH+FB group had significantly lower EPI, BRN, and total fat than VIV+FB rats. VIV+FB rats had significantly higher BRN, EPI, PERI, and total fat than VIV+CH rats. Triglycerides (TG), KID, KID/BW, and BRN/BW were not significantly different among treatment groups. These findings provide valuable information regarding cage design and food bar suitability for long-term use on the ISS.

Lau, Angela↗

Calcium Balance in Mature Rats Exposed to a Space Flight Model

Depressed intestinal calcium absorption (Ca abs.) and lower circulating 1,25-dihydroxyvitamin D (1,25-D) are associated with less positive calcium balance in young 200 g rats exposed to skeletal unloading by hind-limb suspension than controls (C) . To determine the effect of the space flight model on calcium balance in mature rats, we exposed 6 mo. old males weighing 492 +/- 12g to the model for 4 weeks (S) and compared Ca in the diet, urine, feces and 1,25-D in S and C. Rats were fed diets containing sufficient Ca to satisfy metabolic needs, but not to cause deficiency (0.1%). At the end of 4 weeks, there was a 5 percent weight loss in S, but not in C; and no differences in dietary, urine (UCa) or fecal Ca (FCa) in S and C. Net Ca abs. (0.1 vs 2.7 %), 1,25-D (50 +/- 16 vs 47 +/- 14 pg/ml) and Ca balances (-1.8 +/- 4 vs -1.0 +/- 2.9 mg/d) were similar in C and S. UCa loss was added to the model by inducing calciuria with 8% salt diets (HiNa). A 4-fold increase in UCa in C and S was transiently higher in S than C after 1 week. After 4 weeks, loss in BW was greater in S than C, Ca abs was higher in C than S (32 +/- 10 vs 3.5 +/- 16%, p less than .05), 1,25-D greater in S than C (98 +/- 15 vs 79 +/- 14 pg/ml p less than .05) and Ca balance less in S than C (-5.2 +/- 4 vs -1.7 +/- 2 mg/d, p less than .05). Ca balance in the mature rat is unaffected by the space flight model unless calciuria intervenes and reveals the failure of the intestine to enhance Ca abs. and compensate for UCa loss.

Navidi, Meena↗

Absence of Change in Total Daily Energy Expenditure (EE(sub TD)) in Young and Mature Rats During 14 Days of Hypergravity

Effect of age on the response of EE(sub TD) to an increase in gravity was assessed in young (Y; 1.5 month old) and mature (M; 8 month old) Sprague-Dawley rats. Rats were implanted with transmitters to monitor activity, and metabolism was determined by the double labeled water technique. Daily food intake was measured. For each age, rats (n=8 per treatment) were exposed to centrifugation at 2G, or remained at 1G. There was a difference in EE(sub TD) between age groups, 182 plus or minus 11 and 143 plus or minus 5 kcal/kg/day in Y and M, respectively. This difference was attributed in part to a lower activity level in M animals, 48% of Y rats. After day 6 there was no effect on EE(sub TD) of exposure to 2G, or on food intake per 100g BW. Prior studies show a 20% increase in resting EE with hypergravity. In our study the level of activity was reduced to 41% of 1G in both age groups during 2G. For Y at 1G resting EE accounted for 78% of the EE(sub TD) and activity 22%, while at 2G resting EE was 96% of EE(sub TD) and activity 4%. M rats had similar changes. Independent of age, with exposure to hypergravity EE(sub TD) is maintained by behavioral changes.

Wade, C. E.↗

Chandra Observations of the X-ray Environs of SN 1998bw/GRB 980425

We report X-ray studies of the environs of SN 1998bw and GRB 980425 using the Chandra X-Ray Observatory 1281 days after the gamma-ray burst (GRB). Eight X-ray point sources were localized, three and five each in the original error boxes, S1 and S2, assigned for variable X-ray counteparts to the GRB by BeppoSAX. The sum of the discrete X-ray sources plus continuous emission in S2 observed by Chandra on day 1281 is within a factor of 1.5 of the maximum and the upper limits seen by BeppoSAX. We conclude that S2 is the sum of several variable sources that have not disappeared and therefore is not associated with the GRB. Within S1, clear evidence is seen for a decline of approximately a factor of 12 between day 200 and day 1281. One of the sources in S 1, S 1 a, is coincident with the well-determined radio location of SN 1998bw and is certainly the remnant of that explosion. The nature of the other sources is also discussed. Combining our observation of the supernova with others of the GRB afterglow, a smooth X-ray light curve, spanning approx. 1400 days, is obtained by assuming that the burst and supernova were coincident at 35.6 Mpc. When this X-ray light curve is compared with those of the X-ray af "erglows" of ordinary GRBs, X-ray flashes, and ordinary supernovae, evidence emerges for at least two classes of light curves, perhaps bounding a continuum. By 3-10 yr, all these phenomena seem to converge on a common X-ray luminosity, possibly indicative of the supernova underlying them all. This convergence strengthens the conclusion that SN 1998 bw aid GRB 980425 took place in the same object.One possible explanation for the two classes is that a (nearly) standard GRB was observed at different angles, in which case X-ray afterglows with intermediate luminosities should eventually be discovered. Finally, we comment on the contribution of GRB afterglows to the ultraluminous X-ray source population.

Kouveliotou, C.↗

Peripheral vascular responses to heat stress after hindlimb suspension

PURPOSE: The purpose of this study was to determine whether hindlimb suspension (which simulates the effects of microgravity) results in impaired hemodynamic responses to heat stress or alterations in mesenteric small artery sympathetic nerve innervation. METHODS: Over 28 d, 16 male Sprague-Dawley rats were hindlimb-suspended, and 13 control rats were housed in the same type of cage. After the treatment, mean arterial pressure (MAP), colonic temperature (Tcol), and superior mesenteric and iliac artery resistances (using Doppler flowmetry) were measured during heat stress [exposure to 42 degrees C until the endpoint of 80 mm Hg blood pressure was reached (75 +/- 9 min); endpoint Tcore = 43.6 +/- 0.2] while rats were anesthetized (sodium pentobarbital, 50 mg x kg(-1) BW). RESULTS: Hindlimb-suspended and control rats exhibited similar increases in Tcol, MAP, and superior mesenteric artery resistance, and similar decreases in iliac resistance during heat stress (endpoint was a fall in MAP below 80 mm Hg). Tyrosine hydroxylase immunostaining indicated similar sympathetic nerve innervation in small mesenteric arteries from both groups. CONCLUSION: Hindlimb suspension does not alter the hemodynamic or thermoregulatory responses to heat stress in the anesthetized rat or mesenteric sympathetic nerve innervation, suggesting that this sympathetic pathway is intact.

NASA Discipline Cardiopulmonary↗

External Load Affects Ground Reaction Force Parameters Non-uniformly during Running in Weightlessness

Long-term exposure to microgravity induces detrimefits to the musculcskdetal system (Schneider et al., 1995; LeBlanc et al., 2000). Treadmill exercise is used onboard the International Space Station as an exercise countermeasure to musculoskeletal deconditioning due to spaceflight. During locomotive exercise in weightlessness (0G), crewmembers wear a harness attached to an external loading mechanism (EL). The EL pulls the crewmember toward the treadmill, and provides resistive load during the impact and propulsive phases of gait. The resulting forces may be important in stimulating bone maintenance (Turner, 1998). The EL can be applied via a bungee and carabineer clip configuration attached to the harness and can be manipulated to create varying amounts of load levels during exercise. Ground-based research performed using a vertically mounted treadmill found that peak ground reaction forces (GRF) during running at an EL of less than one body weight (BW) are less than those that occur during running in normal gravity (1G) (Davis et al., 1996). However, it is not known how the GRF are affected by the EL in a true OG environment. Locomotion while suspended may result in biomechanics that differ from free running. The purpose of this investigation was to determine how EL affects peak impact force, peak propulsive force, loading rate, and impulse of the GRF during running in 0G. It was hypothesized that increasing EL would result in increases in each GRF parameter.

DeWitt, John↗

A Compact 600 GHz Electronically Tunable Vector Measurement System for Submillimeter Wave Imaging

The design of a complete vector measurement system being tested over 560-635 GHz is presented. The topics include: 1) Current State-of-the-Art in Vector Measurements; 2) Submillimeter Active Imaging Requirements; 3) 600 GHz Vector Measurement System; 4) 450 MHz IF Signal; 5) 450 MHz IF signal @ 1 kHz Res. BW; 6) 450 MHz IF Signal Mixed with Shifted 450 MHz Reference Signal; 7) Reference Signal Offset Generator; 8) Cavity Bandpass Filter; 9) Miniature Multistage Helical Filter; 10) X36 450 MHz Multiplier; 11) 600 GHz Test Setup; 12) 600 GHz Transmit Module; 13) 600 GHz Receive Module; 14) Performance Tests: Amplitude Stability & Dynamic Range; 15) Performance Tests: Phase Stability; 16) Stability at Imaging Bandwidths; 17) Phase Measurement Verification; and 18) The Next Step: Imaging.

phase measurements↗

Gravitational Effects upon Locomotion Posture

Researchers use actual microgravity (AM) during parabolic flight and simulated microgravity (SM) obtained with horizontal suspension analogs to better understand the effect of gravity upon gait. In both environments, the gravitational force is replaced by an external load (EL) that returns the subject to the treadmill. However, when compared to normal gravity (N), researchers consistently find reduced ground reaction forces (GRF) and subtle kinematic differences (Schaffner et al., 2005). On the International Space Station, the EL is applied by elastic bungees attached to a waist and shoulder harness. While bungees can provide EL approaching body weight (BW), their force-length characteristics coupled with vertical oscillations of the body during gait result in a variable load. However, during locomotion in N, the EL is consistently equal to 100% body weight. Comparisons between AM and N have shown that during running, GRF are decreased in AM (Schaffner et al, 2005). Kinematic evaluations in the past have focussed on joint range of motion rather than joint posture at specific instances of the gait cycle. The reduced GRF in microgravity may be a result of differing hip, knee, and ankle positions during contact. The purpose of this investigation was to compare joint angles of the lower extremities during walking and running in AM, SM, and N. We hypothesized that in AM and SM, joints would be more flexed at heel strike (HS), mid-stance (MS) and toe-off (TO) than in N.

DeWitt, John K.↗

Kinematic and EMG Comparison of Gait in Normal and Microgravity

Astronauts regularly perform treadmill locomotion as a part of their exercise prescription while onboard the International Space Station. Although locomotive exercise has been shown to be beneficial for bone, muscle, and cardiovascular health, astronauts return to Earth after long duration missions with net losses in all three areas [1]. These losses might be partially explained by fundamental differences in locomotive performance between normal gravity (NG) and microgravity (MG) environments. During locomotive exercise in MG, the subject must wear a waist and shoulder harness that is attached to elastomer bungees. The bungees are attached to the treadmill, and provide forces that are intended to replace gravity. However, unlike gravity, which provides a constant force upon all body parts, the bungees provide a spring force only to the harness. Therefore, subjects are subjected to two fundamental differences in MG: 1) forces returning the subject to the treadmill are not constant, and 2) forces are only applied to the axial skeleton at the waist and shoulders. The effectiveness of the exercise may also be affected by the magnitude of the gravity replacement load. Historically, astronauts have difficulty performing treadmill exercise with loads that approach body weight (BW) due to comfort and inherent stiffness in the bungee system. Although locomotion can be executed in MG, the unique requirements could result in performance differences as compared to NG. These differences may help to explain why long term training effects of treadmill exercise may differ from those found in NG. The purpose of this investigation was to compare locomotion in NG and MG to determine if kinematic or muscular activation pattern differences occur between gravitational environments.

DeWitt, John K.↗

Excercise Within LBNP as an Artificial Gravity Countermeasure

Previous exercise in space has lacked sufficient loads to maintain preflight cardiovascular and musculoskeletal mass and function. Lower body negative pressure (LBNP) produces a static force equivalent to one Earth body weight by each 52 mm Hg of LBNP during supine posture. LBNP also provides transmural blood pressures simulating upright exercise. Thus, this artificial-gravity concept may help maintain cardiovascular and musculoskeletal systems of crewmembers during prolonged exposure to microgravity. Currently available, bungee cord assisted, treadmill exercise is limited by harness discomfort, lower than normal loads, abnormal post-flight gait, and the absence of gravitational blood pressures within the vascular system. PURPOSE: This project evaluates a method to create artificial gravity using supine LBNP treadmill exercise to prevent loss of physiologic function in microgravity simulated by 30 days of bed rest. Identical twins were used as volunteers so that statistical power could be maximized. This countermeasure is being transitioned to space flight. CURRENT STATUS OF RESEARCH Methods: Six sets of identical twins (6 females and 14 males, 21-36 years) remained in 6 head-down tilt (HDT) bed rest for 30 days to simulate prolonged microgravity. Six subjects were randomly selected to exercise supine in an LBNP chamber for 40 minutes six days per week (EX group), while their twin brothers served as non-exercise controls (CON). Pressure within the exercise LBNP chamber was adjusted to increase load, hence increasing exercise intensity. During supine treadmill exercise, LBNP (52-63 mmHg) was applied to produce foot ward forces equivalent to those for upright running on Earth at 1.0-1.2 times body weight (BW) and subjects performed an interval exercise protocol (40-80% peak exercise capacity [VO2pk]). Five minutes of resting LBNP immediately followed each exercise session. Results: Orthostatic tolerance time decreased significantly after 30 days bed rest in the CON group, but was relatively maintained in the EX group. VO2pk was maintained in EX males, but not in CON males. Isokinetic knee strength (extension, peak torque) decreased significantly in CON males, but was preserved in EX males. The EX group had significantly higher spine muscle strength after bed rest than the CON group. The cross-sectional area of spinal muscle at L4/5 level decreased significantly in the CON group but not in the EX group. Urinary n-telopeptide excretion, an index of bone resorption, was increased during bed rest in CON, but not in EX subjects. This suggests protection by LBNP exercise against the increase in bone resorption typically seen in simulated and actual microgravity. Significant changes in bone mineral density (BMD) in the spine and ribs were observed in CON subjects, but not in EX subjects. Conclusions: Our treadmill exercise protocol within LBNP plus a short period of post-exercise LBNP maintains orthostatic responses, upright exercise capacity and other important physiologic parameters during bed rest. These results document the efficacy of our apparatus and exercise protocol for maintaining physiologic structure and function during long-duration microgravity as simulated by 30 days of HDT bed rest. FUTURE PLANS: More sets of female identical twins are needed to reach significance. The LBNP exercise chamber will be redesigned for flight.

Hargens, A. R.↗

Analysis of Skeletal Muscle Metrics as Predictors of Functional Task Performance

PURPOSE: The ability to predict task performance using physiological performance metrics is vital to ensure that astronauts can execute their jobs safely and effectively. This investigation used a weighted suit to evaluate task performance at various ratios of strength, power, and endurance to body weight. METHODS: Twenty subjects completed muscle performance tests and functional tasks representative of those that would be required of astronauts during planetary exploration (see table for specific tests/tasks). Subjects performed functional tasks while wearing a weighted suit with additional loads ranging from 0-120% of initial body weight. Performance metrics were time to completion for all tasks except hatch opening, which consisted of total work. Task performance metrics were plotted against muscle metrics normalized to "body weight" (subject weight + external load; BW) for each trial. Fractional polynomial regression was used to model the relationship between muscle and task performance. CONCLUSION: LPMIF/BW is the best predictor of performance for predominantly lower-body tasks that are ambulatory and of short duration. LPMIF/BW is a very practical predictor of occupational task performance as it is quick and relatively safe to perform. Accordingly, bench press work best predicts hatch-opening work performance.

Ryder, Jeffrey W.↗

A Better ARED Squat

The 0-G ARED squat under loads the legs relative to the 1g ARED squat. In 1g the knee extensor/flexor muscles are primarily engaged due to the body's center of gravity is behind the knees during the motion of the squat. As body weight does not play a sufficient role 0 G, a crewmember's load exposure is limited by the load delivered by ARED through the exercise bar. Prescription loads for lowerbody resistance exercise in microgravity aim to include 1-G exercise bar load in addition to the crewmember's Earth body weight (BW); however, pressure points from the bar and the 1BW increased load at the shoulders translating to higher loads on the back have been a historical limitation for shoulders, requiring a decrease in exercise load at the start of the mission. Analogous to crewmembers, bed rest subjects report limitations of exercising with high loads on the back while performing squats on the horizontal exercise fixture (HEF), a custom exercise device that serves as an analog to 0-G ARED. Improvements for increasing loads on the HEF squat were suggested by distributing total exercise load between the hips and the bar1. The same is recommended for the 0-G ARED squat, with using current equipment on the ISS, which include the T2 running harness and T2 bungees. Quantification of this improvement has been accessed through computational modeling. The purpose of this study is to characterize joint torque during a squat with a distribution in exercise load on the ARED in 0 G. The analysis used existing models from NASA's Digital Astronaut Project. The biomechanics squat model was integrated with the ARED model and T2 bungees. The spring constant for the bungees were derived from ground testing. Forward dynamic simulation was performed for various conditions including anchor point attachments on the footplate of the ARED, bar load, hip load, and gravitational environment. The model confirms joint torques at knees is lower relative to 1G conditions primarily because the load delivery system is just with the exercise bar in 0 G. By distributing partial loads through use of the bungees to the hips joint-torque profiles were altered during a squat and provided options to enhance targeting lower-body loading in aims as for an improved countermeasure.

Caldwell, E. E.↗

Final Report on the Detection of Green Monopropellants

In 2014, National Aeronautics and Space Administration (NASA) Kennedy Space Center (KSC) funded a project titled "Familiarization and Detection of Green Monopropellants" utilizing Independent Research and Technology Development (IR&TD) and Center Innovation Fund (CIF) funding. The purpose of the project was to evaluate methods of detection for ammonium dinitramide (ADN) and hydroxylammonium nitrate (HAN). An Engineering Services Contract (ESC) task order was created with the scope of evaluation of several methods of detecting ADN- and HAN-based propellants, as well as development of methods for detection. Detection methods include developed methods such as colorimetric indicating absorbent socks, and commercial-off-the- shelf (COTS) units for ammonia detection. An additional goal of the task order was for ESC to become familiar with ADN's and HAN's material properties and material compatibility. Two approaches were initially investigated as possible methods for the detection of HAN (or AFM315E) and ADN (or LMP-103S). These approaches were colorimetric analysis and instrumentation-based COTS vapor sensors utilization. Initial testing showed that the relatively non-existent vapor pressure of the AF-M315E (of which HAN is a major component) propellant would make the use of COTS sensors difficult for real-time area monitoring of HAN; a small response was detected through the use of active COTS sensors, including the RAE Systems MultiRAE Lite and Drager X-act (registered) 5000, but the levels detected were below the threshold limit value for the toxic gas ammonia. Therefore, a detection system ased upon a colorimetric indicator impregnated into an absorbent material was developed. Preliminary analysis (ESC-245-FDG-001) identified a particularly outstanding candidate as a colorimetric indicator for the detection of the presence of AF-M315E in the form of a Methyl Red (Basic) indicator. Materials impregnated with this indicator exhibit significant color change and the materials are not susceptible to interference from exposure to water or carbon dioxide. The completed detection system for HAN/AF-M315E consists of absorbent socks packed with Fisher Universal Spill Absorbent capable of absorbing and containing any propellant spills that they come into contact with along with indicating wipes. The absorbent socks are also chemically treated with a Methyl Red (Basic) indicator solution to provide the end user with a visual indication that a leak has occurred and proper protective precautions must be undertaken. An added benefit of this detection system is that the absorbent socks should neutralize/absorb any commodity that it comes into contact with (until saturation is reached). Additional adsorbent socks can be deployed until a color change is not seen, indicating that the HAN/AF-M315E contamination has been contained. The indicating wipes provide the user the opportunity to wipe surfaces to determine if there is any HAN/AF-M315E or HAN/AFM315E residue present. The wipes should allow the detection of fuel levels that may be too small to detect with the absorbent socks. The development of a detection system for the ADN/LMP-103S focused on the use of various COTS sensors used as real-time area monitoring devices and personal dosimeters. These COTS based sensor systems were of several different types, including both actively pumped and diffusion-based passive systems, as well as a "rope"-type chemical sensing cable. The results highlighted some of the major differences between the two monopropellants undergoing evaluation. Unlike HAN, ADN (which is the major constituent of LMP-103S) exhibits a much more volatile nature in comparison to AF-M315E. In fact, testing showed that a large percentage of the fuel was lost during the sampling measurement (greater than 10 percent by mass); although this testing cannot tell if the volatile component is the ADN itself or another component of the monopropellant solution. Not surprisingly, all four of the procured vapor-based COTS sensors showed positive results when exposed to solutions of the LMP-103S (ESC-245-FDG-002). The completed detection system for ADN/LMP-103S consists of a combination of two of the tested COTS sensor systems, the RAE Systems MultiRAE Lite and the BW Technologies GasAlert Extreme. These systems are meant to be used in conjunction with one another, which allows for the end-user to have both real-time area monitoring (MultiRAE Lite) as well as a personal dosimeter device (GasAlert Extreme) which can be worn as additional personal protective equipment. An stainless steel extension wand was fabricated and included in the detection system for the MultiRAE Lite to allow for more remote sensing, and connects via the active pumping inlet of the sensor. As stated, the final results of this testing resulted in the production of two "kits" which can be used for the detection of HAN/AF-M315E and ADN/LMP-103s (ESC-245-FDG-003).

Detection↗

Lidar Observations Revealing Transport of O3 in the Presence of a Nocturnal Low-Level Jet: Regional Implications for "Next-Day" Pollution

Remotely sensed profiles of ozone (O3) and wind are presented continuously for the first time during anocturnal low-level jet (NLLJ) event occurring after a severe O3 episode in the Baltimore-Washington D.C.(BW) urban corridor throughout 11-12 June 2015. High-resolution O3 lidar observations indicate a well mixedand polluted daytime O3 reservoir, which decayed into a contaminated nocturnal residual layer(RL) with concentrations between 70 and 100 ppbv near 1 km above the surface. Observations indicatethe onset of the NLLJ was responsible for transporting polluted O3 away from the region, while simultaneouslyaffecting the height and location of the nocturnal residual layer. High-resolution modelinganalyses and next-day (12 June) lidar, surface, and balloon-borne observations indicate the trajectory ofthe NLLJ and polluted residual layer corresponds with ''next-day'' high O3 at sites throughout thesouthern New England region (New York, Connecticut, Massachusetts). The novel O3 lidar observationsare evidence of both nocturnal advection (via high NLLJ wind fields) and entrainment of the pollutedresidual layer in the presence of the ''next-day'' convectively growing boundary layer. In the greatercontext, the novel observational suite described in this work has shown that the chemical budget in areasdownwind of major urban centers can be altered significantly overnight during transport events such asthe NLLJ.

ozone↗

Twenty Years of Terra MODIS Spectral Performance using the Spectro-Radiometric Calibration Assembly

The Moderate Resolution Imaging Spectroradiometer (MODIS) instrument on-board the Terra spacecraft has provided valuable Earth data to the science community for the last 20 years. Equipped with several on-board calibrators (OBCs), MODIS has continued to operate nominally since its launch in December 1999. The Spectro-Radiometric Calibration Assembly (SRCA) is one such OBC that is able to provide on-orbit measurements of the MODIS reflective solar bands (RSBs) in radiometric, spatial and spectral modes. While the SRCA is operating in spectral mode, it is able to monitor the center wavelength (CW), bandwidth (BW) and in-band relative spectral response (RSR) of most RSBs. Prelaunch measurements of the CWs, BWs and RSRs of the RSBs were performed at the system level using the Spectral measurement Assembly (SpMA). Using both the prelaunch measurements and the measurements obtained on-orbit using the SRCA, the changes in the spectral response of the MODIS reflective bands can be monitored throughout the mission. This paper will provide a brief description of the spectral calibration approach and report on-orbit changes in these spectral performance parameters and their uncertainties over the last 20 years. It will also address changes to the SRCA operation on-orbit and their impact on measured spectral calibration results. Despite two decades in orbit, the spectral responses for most Terra MODIS reflective bands continue to remain within their design specifications.

MODIS↗

Mid-IR interferometric nulling for TPF

By the middle of 2006, the Interferometry Technology development program for NASA’s Terrestrial Planet Finder (TPF) Mission has the goal of demonstrating deep and stable interferometric nulling of broadband Mid-IR thermal radiation under conditions that are traceable to the expected on-orbit conditions. Specifically, the task is to demonstrate null levels of 10 to the negative 6 power, with a 50% BW centered at 10 um, with null stabilities of 10 to the negative 7 power all at cryogenic temperatures for observational periods of a couple of hours. The Achromatic Nulling activity at JPL addresses this concern in two testbeds: the warm nulling testbed and the cryonulling testbed. The warm nulling testbed will demonstrate the physics of nulling broadband thermal sources in an environment that is conducive to efficient research. We’ll explore nulling techniques, optical-mechanical alignment methods, motion control, and path-length metrology for a single beam interferometer, as well as preliminary planet detection techniques. Ultimate nulling capabilities under conditions that are more flight-like will be demonstrated in cryogenic nulling testbed. Knowledge gained from operation at room temperature will be applied to the cryongenic experiment where we face the additional challenges of extreme temperatures, cryongenic actuators, component survivability and fluxes that are within an order of magnitude of expected flux levels on orbit. Concurrently, we will develop a low flux mid-IR camera that will allow us to measure the nulls at these faint photon fluxes. This talk will review this development activity and will include recent nulling experimental results and plans for future work.

Vasisht, Gautam↗

Crew State and Risk Model Development to Predict Hydration Status During Extravehicular Activity Training Events

Introduction: Hydration is critical for optimal human health and performance and dehydration can lead to impaired cardiovascular function, thermal dysregulation, decreased blood plasma volume, and cognitive impacts, particularly during physical activity. Prolonged and repeated extravehicular activities (EVA) without sufficiently available drinking water may increase risk for dehydration, which could impair crew health and impact mission success. Understanding hydration needs and potential effects on health and performance are necessary to optimize crew well-being and enable successful EVA objectives. This study aims to develop a model of hydration status during EVA using water balance techniques. Methods: Water balance measures were collected on 15 healthy astronauts who performed ≈6-hour simulated microgravity extravehicular activity (EVA) training in the NASA Neutral Buoyancy Laboratory (NBL). Data collected included pre-and post-EVA nude body weight (BW), maximum absorption garment (MAG) weight, Disposable In-suit Drink Bag (DIDB) weight, urine specific gravity (USG), and extra pre-EVA intake (W). Variables were combined to create the water balance model as pre-EVA (Hn)= BWn+ MAGn+ DIDBn+ Wnand post EVA (Hn+1) = BWn+1+ MAGn+1+ DIDBn+1. Urine specific gravity values were used to refine water balance measures into hydration categories: Hydrated, Marginally Hydrated, and Dehydrated. Results: Pre-EVA modeling indicated53% of crew were hydrated, 20% were marginally hydrated, and 27% were dehydrated. Alternately, Hn+1 showed 13% of crew remained hydrated, 47% were marginally hydrated, and 40% were dehydrated at the end of the EVA. Furthermore, 75% of the crewmembers who started sufficiently hydrated finished the run marginally hydrated or dehydrated. According to USG indices presented by Casa and Lawrence, et al. (2000), only 25% of the crew started and remained hydrated throughout the EVA, and those who were dehydrated at the outset stayed dehydrated. Conclusion: Model outcomes assessing hydration status during 6-hour simulated microgravity EVAs demonstrate the necessity to further address hydration requirements for optimal human performance during spaceflight and EVA. This study enables additional baseline development of the Crew State and Risk Model Hydration, Nutrition, and Waste Management component that aims to provide individualized crew state and risk predictions during EVAs. Reference: Casa, D. J., Armstrong, L. E., et al. (2000). National Athletic Trainers’ Association Position Statement: Fluid Replacement for Athletes. Journal of Athletic Training, 35:212-224.

L Cooper↗