Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BNCT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Development of a dual phantom technique for measuring the fast neutron component of dose in boron neutron capture therapy

Purpose: Research and development of various accelerator-based irradiation systems for boron neutron capture therapy (BNCT) is underway throughout the world. Many of these systems are nearing or have started clinical trials. Before the start of treatment with BNCT, the relative biological effectiveness (RBE) for the fast neutrons (over 10 keV) incident to the irradiation field must be estimated. Measurements of RBE are typically performed by biological experiments with a phantom. Although the dose deposition due to secondary gamma rays is dominant, the relative contributions of thermal neutrons (below 0.5 eV) and fast neutrons are virtually equivalent under typical irradiation conditions in a water and/or acrylic phantom. Uniform contributions to the dose deposited from thermal and fast neutrons are based in part on relatively inaccurate dose information for fast neutrons. This study sought to improve the accuracy in the dose estimation for fast neutrons by using two phantoms made of different materials in which the dose components can be separated according to differences in the interaction cross sections. The development of a “dual phantom technique” for measuring the fast neutron component of dose is reported. Methods: One phantom was filled with pure water. The other phantom was filled with a water solution of lithium hydroxide (LiOH) capitalizing on the absorbing characteristics of lithium-6 (Li-6) for thermal neutrons. Monte Carlo simulations were used to determine the ideal mixing ratio of Li-6 in LiOH solution. Changes in the depth dose distributions for each respective dose component along the central beam axis were used to assess the LiOH concentration at the 0, 0.001, 0.01, 0.1, 1, and 10 wt. % levels. Simulations were also performed with the phantom filled with 10 wt. % {sup 6}LiOH solution for 95%-enriched Li-6. A phantom was constructed containing 10 wt. % {sup 6}LiOH solution based on the simulation results. Experimental characterization of the depth dose distributions of the neutron and gamma-ray components along the central axis was performed at Heavy Water Neutron Irradiation Facility installed at Kyoto University Reactor using activation foils and thermoluminescent dosimeters, respectively. Results: Simulation results demonstrated that the absorbing effect for thermal neutrons occurred when the LiOH concentration was over 1%. The most effective Li-6 concentration was determined to be enriched {sup 6}LiOH with a solubility approaching its upper limit. Experiments confirmed that the thermal neutron flux and secondary gamma-ray dose rate decreased substantially; however, the fast neutron flux and primary gamma-ray dose rate were hardly affected in the 10%-{sup 6}LiOH phantom. It was confirmed that the dose contribution of fast neutrons is improved from approximately 10% in the pure water phantom to approximately 50% in the 10%-{sup 6}LiOH phantom. Conclusions: The dual phantom technique using the combination of a pure water phantom and a 10%-{sup 6}LiOH phantom developed in this work provides an effective method for dose estimation of the fast neutron component in BNCT. Improvement in the accuracy achieved with the proposed technique results in improved RBE estimation for biological experiments and clinical practice.

60 APPLIED LIFE SCIENCES↗

Therapeutic efficacy of boron neutron capture therapy mediated by boron-rich liposomes for oral cancer in the hamster cheek pouch model

Unilamellar liposomes formulated with an equimolar mixture of cholesterol and 1,2-distearoyl-sn-glycero-3-phosphocholine, incorporating K[nido-7-CH 3 (CH 2 )15-7,8-C 2 B 9 H 11 ] in the lipid bilayer, and encapsulating Na 3 [1-(2’-B 10 -H 9 )-2-NH 3 B 10 H 8 ] were prepared by probe sonication and investigated in vivo. Microwave assisted digestion followed by inductively coupled plasma-optical emission spectroscopy was utilized to determine the biodistribution of boron in various tissues following either a single tail vein injection or two identical injections (separated by 24 hours) of the liposomal suspension in BALB/c mice bearing EMT6 mammary adenocarcinomas in their right flank. Double-injection protocols resulted in a boron content in the tumor exceeding 50 µg of boron per gram of tissue for 48 to 72 hours subsequent to the initial injection while tumor:blood boron ratios were more ideal from 54 hours (1.9:1) to 96 hours (5.7:1) subsequent to the initial injection. Tumor bearing mice were given a double-injection of liposomes containing the 10 B-enriched analogs of the aforementioned agents and subjected to a 30 minute irradiation by thermal neutrons with a flux of 8.8 x 10 8 (±7%) neutrons/cm 2 s integrated over the energy range of 0.0 – 0.414 eV. Significant tumor response for a single BNCT treatment was demonstrated by growth curves versus a control group. Vastly diminished tumor growth was witnessed at 14 days (186% increase versus 1551% in controls) in mice that were given a second injection/radiation treatment 7 days after the first. Mice given a one hour neutron irradiation following the double-injection of liposomes had a similar response (169% increase at 14 days) suggesting that neutron fluence is the limiting factor towards BNCT efficacy in this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-21: A D-D Based Neutron Generator System for Boron Neutron Capture Therapy: A Feasibility Study

Purpose: To investigate the feasibility of a deuterium-deuterium (DD) neutron generator for application in boron neutron capture therapy (BNCT) of brain cancer Methods: MCNP simulations were performed using a head phantom and a monoenergetic neutron source, which resembles the point source in a DD generator that emits 2.45-MeV neutrons. Source energies ranging from 5eV to 2.45MeV were simulated to determine the optimal treatment energy. The phantom consisted of soft tissue, brain tissue, skull, skin layer, and a brain tumor of 5 cm in diameter. Tumor depth was varied from 5–10 cm. Boron-10 concentrations of 10 ppm, 15 ppm, and 30 ppm were used in the soft/brain tissues, skin, and tumor, respectively. The neutron flux required to deliver 60 Gy to the tumor as well as the normal tissue doses were determined. Results: Beam energies between 5eV and 10keV obtained doses with the highest dose ratios (3.3–25.9) between the tumor and the brain at various depths. The dose ratio with 2.45-MeV neutrons ranged from 0.8–6.6. To achieve the desired tumor dose in 40 minutes, the required neutron flux for a DD generator was between 8.8E10 and 5.2E11 n/s and the resulting brain dose was between 2.3 and 18 Gy, depending on the tumor depth. The skin and soft tissue doses were within acceptable tolerances. The boron-neutron interaction accounted for 54–58% of the total dose. Conclusion: This study shows that the DD neutron generator can be a feasible neutron source for BNCT. The required neutron flux for treatment is achievable with the current DD neutron technology. With a well-designed beam shaping assembly and treatment geometry, the neutron flux can be further improved and a 60-Gy prescription can be accurately delivered to the target while maintaining tolerable normal tissue doses. Further experimental studies will be developed and conducted to validate the simulation results.

60 APPLIED LIFE SCIENCES↗

Ultrathin Boron Growth onto Nanodiamond Surfaces via Electrophilic Boron Precursors

Diamond as a templating substrate is largely unexplored, and the unique properties of diamond, including its large bandgap, thermal conductance, and lack of cytotoxicity, makes it versatile in emergent technologies in medicine and quantum sensing. Surface termination of an inert diamond substrate and its chemical reactivity are key in generating new bonds for nucleation and growth of an overlayer material. Oxidized high-pressure high temperature (HPHT) nanodiamonds (NDs) are largely terminated by alcohols that act as nucleophiles to initiate covalent bond formation when an electrophilic reactant is available. In this work, we demonstrate a templated synthesis of ultrathin boron on ND surfaces using trigonal boron compounds. Boron trichloride (BCl 3 ), boron tribromide (BBr 3 ), and borane (BH 3 ) were found to react with ND substrates at room temperature in inert conditions. BBr 3 and BCl 3 were highly reactive with the diamond surface, and sheet-like structures were produced and verified with electron microscopy. Surface-sensitive spectroscopies were used to probe the molecular and atomic structure of the ND constructs’ surface, and quantification showed the boron shell was less than 1 nm thick after 1–24 h reactions. Observation of the reaction supports a self-terminating mechanism, similar to atomic layer deposition growth, and is likely due to the quenching of alcohols on the diamond surface. X-ray absorption spectroscopy revealed that boron-termination generated midgap electronic states that were originally predicted by density functional theory (DFT) several years ago. DFT also predicted a negative electron surface, which has yet to be confirmed experimentally here. The boron-diamond nanostructures were found to aggregate in dichloromethane and were dispersed in various solvents and characterized with dynamic light scattering for future cell imaging or cancer therapy applications using boron neutron capture therapy (BNCT). The unique templating mechanism based on nucleophilic alcohols and electrophilic trigonal precursors allows for covalent bond formation and will be of interest to researchers using diamond for quantum sensing, additive manufacturing, BNCT, and potentially as an electron emitter.

36 MATERIALS SCIENCE↗

High-flux neutron source based on a liquid-lithium target

A prototype compact Liquid Lithium Target (LiLiT), able to constitute an accelerator-based intense neutron source, was built. The neutron source is intended for nuclear astrophysical research, boron neutron capture therapy (BNCT) in hospitals and material studies for fusion reactors. The LiLiT setup is presently being commissioned at Soreq Nuclear research Center (SNRC). The lithium target will produce neutrons through the {sup 7}Li(p,n){sup 7}Be reaction and it will overcome the major problem of removing the thermal power generated by a high-intensity proton beam, necessary for intense neutron flux for the above applications. The liquid-lithium loop of LiLiT is designed to generate a stable lithium jet at high velocity on a concave supporting wall with free surface toward the incident proton beam (up to 10 kW). During off-line tests, liquid lithium was flown through the loop and generated a stable jet at velocity higher than 5 m/s on the concave supporting wall. The target is now under extensive test program using a high-power electron-gun. Up to 2 kW electron beam was applied on the lithium flow at velocity of 4 m/s without any flow instabilities or excessive evaporation. High-intensity proton beam irradiation will take place at SARAF (Soreq Applied Research Accelerator Facility) superconducting linear accelerator currently in commissioning at SNRC.

43 PARTICLE ACCELERATORS↗

Application of the BINS superheated drop detector spectrometer to the {sup 9}Be(p,xn) neutron energy spectrum determination

In the framework of TRASCO-BNCT project, a Bubble Interactive Neutron Spectrometer (BINS) device was applied to the characterization of the angle-and energy-differential neutron spectra generated by the {sup 9}Be(p,xn)reaction. The BINS spectrometer uses two superheated emulsion detectors, sequentially operated at different temperatures and thus provides a series of six sharp threshold responses, covering the 0.1-10 MeV neutron energy range. Spectrum unfolding of the data was performed by means of MAXED code. The obtained angle, energy-differential spectra were compared with those measured with a Bonner sphere spectrometer, a silicon telescope spectrometer and literature data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single step synthesis of nanostructured boron nitride for boron neutron capture therapy

Nanostructured Boron Nitride (BN) has been successfully synthesized by carbo-thermic reduction of Boric Acid (H{sub 3}BO{sub 3}). This method is a relatively low temperature synthesis route and it can be used for large scale production of nanostructured BN. The synthesized nanoparticles have been characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and differential thermal analyzer (DTA). XRD analysis confirmed the formation of single phase nanostructured Boron Nitride. SEM analysis showed that the particles are spherical in shape. DTA analysis showed that the phase is stable upto 900 °C and the material can be used for high temperature applications as well boron neutron capture therapy (BNCT)

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-E-J-104: Single Photon Image From PET with Insertable SPECT Collimator for Boron Neutron Capture Therapy: A Feasibility Study

Purpose: The aim of our proposed system is to confirm the feasibility of extraction of two types of images from one positron emission tomography (PET) module with an insertable collimator for brain tumor treatment during the BNCT. Methods: Data from the PET module, neutron source, and collimator was entered in the Monte Carlo n-particle extended (MCNPX) source code. The coincidence events were first compiled on the PET detector, and then, the events of the prompt gamma ray were collected after neutron emission by using a single photon emission computed tomography (SPECT) collimator on the PET. The obtaining of full width at half maximum (FWHM) values from the energy spectrum was performed to collect effective events for reconstructed image. In order to evaluate the images easily, five boron regions in a brain phantom were used. The image profiles were extracted from the region of interest (ROI) of a phantom. The image was reconstructed using the ordered subsets expectation maximization (OSEM) reconstruction algorithm. The image profiles and the receiver operating characteristic (ROC) curve were compiled for quantitative analysis from the two kinds of reconstructed image. Results: The prompt gamma ray energy peak of 478 keV appeared in the energy spectrum with a FWHM of 41 keV (6.4%). On the basis of the ROC curve in Region A to Region E, the differences in the area under the curve (AUC) of the PET and SPECT images were found to be 10.2%, 11.7%, 8.2% (center, Region C), 12.6%, and 10.5%, respectively. Conclusion: We attempted to acquire the PET and SPECT images simultaneously using only PET without an additional isotope. Single photon images were acquired using an insertable collimator on a PET detector. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, Information and Communication Technologies (ICT) and Future Planning (MSIP)(Grant No.2009 00420) and the Radiation Technology R and D program (Grant No.2013M2A2A7043498), Republic of Korea.

07 ISOTOPE AND RADIATION SOURCES↗

Accelerator based epithermal neutron source

We review the current status of the development of accelerator sources of epithermal neutrons for boron neutron capture therapy (BNCT), a promising method of malignant tumor treatment. Particular attention is given to the source of epithermal neutrons on the basis of a new type of charged particle accelerator: tandem accelerator with vacuum insulation and lithium neutron-producing target. It is also shown that the accelerator with specialized targets makes it possible to generate fast and monoenergetic neutrons, resonance and monoenergetic gamma-rays, alpha-particles, and positrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of an Accelerator-Based Epithermal Neutron Source for Boron Neutron Capture Therapy

The paper presents a review of the current state of development of accelerator-based epithermal neutron sources for boron neutron capture therapy (BNCT), a promising method for the treatment of malignant tumors. Special attention is paid to an epithermal neutron source based on a new type of accelerator of charged particles: a tandem accelerator with vacuum insulation and a lithium neutron-producing target.

43 PARTICLE ACCELERATORS↗

Carboranylporphyrins and uses thereof

The present invention is directed to low toxicity boronated compounds and methods for their use in the treatment, visualization, and diagnosis of tumors. More specifically, the present invention is directed to low toxicity carborane-containing porphyrin compounds with halide, amine, or nitro groups and methods for their use particularly in boron neutron capture therapy (BNCT), X-ray radiation therapy (XRT), and photodynamic therapy (PDT) for the treatment of tumors of the brain, head and neck, and surrounding tissue. The invention is also directed to using these carborane-containing porphyrin compounds in methods of tumor imaging and/or diagnosis such as MRI, SPECT, or PET.

60 APPLIED LIFE SCIENCES↗

Symmetric and asymmetric halogen-containing metallocarboranylporphyrins and uses thereof

The present invention is directed to low toxicity boronated compounds and methods for their use in the treatment, visualization, and diagnosis of tumors. More specifically, the present invention is directed to low toxicity halogenated, carborane-containing 5,10,15,20-tetraphenylporphyrin compounds and methods for their use particularly in boron neutron capture therapy (BNCT) and photodynamic therapy (PDT) for the treatment of tumors of the brain, head and neck, and surrounding tissue. The invention is also directed to using these halogenated, carborane-containing tetraphenylporphyrin compounds in methods of tumor imaging and/or diagnosis such as MRI, SPECT, or PET.

60 APPLIED LIFE SCIENCES↗

Carbonylporphyrins and uses thereof

The present invention is directed to low toxicity boronated compounds and methods for their use in the treatment, visualization, and diagnosis of tumors. More specifically, the present invention is directed to low toxicity carborane-containing porphyrin compounds with halide, amine, or nitro groups and methods for their use particularly in boron neutron capture therapy (BNCT), X-ray radiation therapy (XRT), and photodynamic therapy (PDT) for the treatment of tumors of the brain, head and neck, and surrounding tissue. The invention is also directed to using these carborane-containing porphyrin compounds in methods of tumor imaging and/or diagnosis such as MRI, SPECT, or PET.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Criticality Benchmarking of the Oregon State TRIGA Reactor Using the MCNP Burn Option

Neutronic analyses of the Oregon State TRIGA Reactor (OSTR) have historically been performed using a thoroughly validated MCNP model. This model was originally created in 1997 in support of boron neutron capture therapy (BNCT) research, when the core still utilized highly-enriched uranium (HEU) fuel. The OSTR core was converted to low-enriched uranium (LEU) in the fall of 2008. To more accurately represent the converted state of the core, the MCNP model was modified to incorporate fuel material information from the fuel manufacturer (AREVA). In previous versions of the model, the fuel elements were assumed to have a uniform isotopic composition. Chemical analysis from AREVA provided far more resolved material information, allowing for increased fidelity in the representation of the fuel. The model was also updated to ENDF/B-VII.1 cross section libraries as the previous model utilized ENDF/B-VI. The primary impetus for the update of the MCNP model was the desire to have a more accurate assessment of criticality conditions of the OSTR. The OSTR utilizes three core configurations which are defined by the contents of the B1 grid position. If fuel resides in B1, this is designated as the 'normal' core. Otherwise, there are two aluminum in-core irradiation tubes (ICITs) that can be placed in B1. There is an unlined tube, designated simply as the ICIT, and there is a cadmium-lined tube, designated as the CLICIT. Table 1 contains a summary of the results of a series of MCNP criticality calculations which used the original 'fresh fuel' isotopics from the fall of 2008 in conjunction with critical rod height data from December 2013. Calculations were performed at 15 W, which is where the daily core excess measurements are taken, and at 1 MW, which is the current full-power level at the OSTR. The k-effective values indicate that the fresh fuel material cards are highly inaccurate and over-predict the criticality by at least $1.20 in every core configuration (based on a β{sub eff} value of 0.0075), thus it was desired to perform a depletion calculation to obtain more accurate fuel information. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Benchmarking Monte Carlo codes for the modelling of low-energy neutron production target reactions

The increasing adoption of accelerator-based neutron sources (ABNS) for applications including neutron capture therapy (NCT) research has highlighted the need for accurate simulation tools. Precise modelling of the neutron production target is crucial to ensure that simulated predictions of neutron beam characteristics used for subsequent beam shaping assembly design are reliable. This work presents a comprehensive benchmarking of four widely-used Monte Carlo codes - Geant4, PHITS, FLUKA (CERN), and MCNP - for modelling low-energy neutron production target reactions. Using their recommended physics models and cross-section libraries, we evaluate each code’s performance in simulating four beam-target reactions: 7 Li(p,n) 7 Be, 9 Be(p,n) 9 B, 9 Be(d,n) 10 B, and C(d,n)N. Predictions of neutron yield, angular distributions, and energy spectra are compared against available thick target experimental data. Results show varying levels of agreement between the codes depending on the reaction type, energy range, and beam characteristics. Geant4, MCNP and PHITS are the overall best performing codes for the simulation of total neutron yield and yield in the forward direction across most reactions. Across energies where experimental benchmarks exist, inter-code discrepancies in total and forward-directed yield are typically 10 to 30%, with larger deviations at near-threshold incident ion energies. PHITS provides the best overall reproduction of experimental spectra, particularly for the 9 Be(p,n) 9 B reaction. Additionally, PHITS demonstrates superior computational performance for most reactions. These findings provide valuable guidance for ABNS design, highlighting the strengths and limitations of each code for the simulation of low-energy neutron production reactions.

43 PARTICLE ACCELERATORS↗