Engineering PapersSearch

SEARCH · Engineering Papers

Results for “BLOOD PRESSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Responses of heart rate and blood pressure to KC-135 hyper-gravity

Many investigators have clarified the effects of hyper gravitational-inertial forces (G) upon the cardiovascular system, using the centrifugal apparatus with short rotating radius. We investigated the cardiovascular responses to KC-135 hyper-G flight with negligibly small angular velocity. Six normal, healthy subjects 29 to 40 years old (5 males and 1 female) took part in this experiment. Hyper gravitational-inertial force was generated by the KC-135 hyper-G flight, flown in a spiral path with a very long radius of 1.5 miles. Hyper-G was sustained for 3 minutes with 1.8 +Gz in each session and was repeatedly exposed to very subject sitting on a chair 5 times. The preliminary results of blood pressure and R-R interval are discussed. An exposure of 1.8 +Gz stress resulted in a remarkable increase of systolic and diastolic blood pressure, while the pulse pressure did not change and remained equal to the control level regardless of an exposure of hyper-G. These results in blood pressure indicate an increase of resistance in the peripheral vessels, when an exposure of hyper-G was applied. The R-R interval was calculated from ECG. R-R interval in all subjects was changed but not systematically, and R-R interval became obviously shorter during the hyper-G period than during the 1 +Gz control period although R-R interval varied widely in some cases. The coefficient of variation of R-R interval was estimated to determine the autonomic nerve activity, but no significant change was detectable.

Satake, Hirotaka

Blood Pressure Responses and Mineral Ocorticoid Levels in the Suspended Rat Model for Weightlessness

Cardiovascular responses and fluid/electrolyte shifts seen during space flight are attributed to cephalad redistribution of vascular fluid. The antiorthostatic (AO) rat (suspended head down tilted, 15-20 deg) is used to model these responses. Current studies show that elevated blood pressures in A0 rats are sustained for periods up to seven days. Comparisons are made with presuspension rats. Increased blood pressure in head down tilted subjects suggests a specific response to A0 positioning, potentially relatable to cephalad fluid shift. To assess a role for hormonal regulation of sodium excretion, serum aldosterone levels were measured.

Musacchia, X. J.

Alanine increases blood pressure during hypotension

The effect of L-alanine administration on blood pressure (BP) during haemorrhagic shock was investigated using anesthetized rats whose left carotid arteries were cannulated for BP measurement, blood removal, and drug administration. It was found that L-alanine, in doses of 10, 25, 50, 100, and 200 mg/kg, increased the systolic BP of hypotensive rats by 38 to 80 percent (while 100 mg/kg pyruvate increased BP by only 9.4 mmhg, not significantly different from saline). The results suggest that L-alanine might influence cardiovascular function.

Conlay, L. A.

Mechanism of blood pressure and R-R variability: insights from ganglion blockade in humans

Spontaneous blood pressure (BP) and R-R variability are used frequently as 'windows' into cardiovascular control mechanisms. However, the origin of these rhythmic fluctuations is not completely understood. In this study, with ganglion blockade, we evaluated the role of autonomic neural activity versus other 'non-neural' factors in the origin of BP and R-R variability in humans. Beat-to-beat BP, R-R interval and respiratory excursions were recorded in ten healthy subjects (aged 30 +/- 6 years) before and after ganglion blockade with trimethaphan. The spectral power of these variables was calculated in the very low (0.0078-0.05 Hz), low (0.05-0.15 Hz) and high (0.15-0.35 Hz) frequency ranges. The relationship between systolic BP and R-R variability was examined by cross-spectral analysis. After blockade, R-R variability was virtually abolished at all frequencies; however, respiration and high frequency BP variability remained unchanged. Very low and low frequency BP variability was reduced substantially by 84 and 69 %, respectively, but still persisted. Transfer function gain between systolic BP and R-R interval variability decreased by 92 and 88 % at low and high frequencies, respectively, while the phase changed from negative to positive values at the high frequencies. These data suggest that under supine resting conditions with spontaneous breathing: (1) R-R variability at all measured frequencies is predominantly controlled by autonomic neural activity; (2) BP variability at high frequencies (> 0.15 Hz) is mediated largely, if not exclusively, by mechanical effects of respiration on intrathoracic pressure and/or cardiac filling; (3) BP variability at very low and low frequencies (< 0.15 Hz) is probably mediated by both sympathetic nerve activity and intrinsic vasomotor rhythmicity; and (4) the dynamic relationship between BP and R-R variability as quantified by transfer function analysis is determined predominantly by autonomic neural activity rather than other, non-neural factors.

Non-NASA Center

Wearable Beat-to-Beat Blood Pressure Monitor

Linea Research Corporation has developed a wearable noninvasive monitor that provides continuous blood pressure and heart rate measurements in extreme environments. Designed to monitor the physiological effects of astronauts' prolonged exposure to reduced-gravity environments as well as the effectiveness of various countermeasures, the device offers wireless connectivity to allow transfer of both real-time and historical data. It can be modified to monitor the health status of astronaut crew members during extravehicular missions.

Lee, Yong Jin

Mechanisms of blood pressure alterations in response to the Valsalva maneuver in postural tachycardia syndrome

The postural tachycardia syndrome (POTS) is characterized clinically by orthostatic lightheadedness and tachycardia. When these patients perform a Valsalva maneuver, there is an excessive blood pressure increment after cessation of the maneuver (phase IV) that is sometimes associated with headaches. It is not known whether excessive phase IV is due to excessive peripheral vascular tone (an alpha-adrenergic mechanism) or is a manifestation of increased beta-adrenergic tone (hyperadrenergic state). The authors undertook a pharmacologic study evaluating the effect of intravenous phentolamine (alpha-adrenergic antagonist) and propranolol (beta-adrenergic antagonist) on the different phases of the Valsalva maneuver in a group of patients with POTS and age-matched normal control subjects. Patients with POTS had mean phases, when compared with controls, that were characterized by more negative II_E (p = 0.07), smaller II_L (p = 0.04), and significantly larger phase IV (p = 0.001). The effect of phentolamine was qualitatively and quantitatively different in POTS when compared with controls. Ten mg phentolamine in controls resulted in a significant accentuation of phase II_E (p = 0.001), attenuation of phase II_L (p = 0.002), and increase of phase IV (57.6 vs 30.7 mm Hg; p = 0.025). These changes resembled those of patients with POTS at baseline. In patients with POTS, the phase II abnormalities, already present, were further accentuated (p <0.001), and phase IV became smaller (50.6 vs 73.8 mm Hg; p = 0.09). Propranolol had no significant effect on phases II_E and II_L, but significantly reduced phase IV in both controls (p <0.05) and in patients with POTS (p <0.001) and improved the headache symptoms, when present, during and after phase IV. The authors conclude that phase IV is mainly under beta-adrenergic regulation and that the exaggerated phase IV in POTS is a result of a hyperadrenergic state.

Non-NASA Center

Blood pressure measurement and display system

System is described that employs solid state circuitry to transmit visual display of patient's blood pressure. Response of sphygmomanometer cuff and microphone provide input signals. Signals and their amplitudes, from turn-on time to turn-off time, are continuously fed to data transmitter which transmits to display device.

Farkas, A. J.

Evaluation of the relationship between motion sickness symptomatology and blood pressure, heart rate, and body temperature

This study investigated the relationship between the development of symptoms of motion sickness and changes in blood pressure, heart rate, and body temperature. Twelve subjects were each evaluated four times using the vestibular-visual interaction test (Graybiel and Lackner, 1980). The results were analyzed both within and across individual subjects. Neither a systematic group nor consistent individual relationship was found between the physiological parameters and the appearance of symptoms of motion sickness. These findings suggest that biofeedback control of the physiological variables studied is not likely to prevent the expression of motion sickness symptomatology.

Graybiel, A.