Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BLOOD FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The effect of entrance flow development on vortex formation and wall shear stress in a curved artery model

In this work, we numerically investigate the effect of entrance condition on the spatial and temporal evolution of multiple three-dimensional vortex pairs and the wall shear stress distribution in a curved artery model. We perform this study using a Newtonian blood-analog fluid subjected to a pulsatile flow with two inflow conditions. The first flow condition is fully developed while the second condition is undeveloped (i.e., uniform). We discuss the connection along the axial direction between regions of organized vorticity observed at various cross sections of the model and compare results between the different entrance conditions. We model a human artery with a simple, rigid 180° curved pipe with a circular cross section and constant curvature, neglecting the effects of taper, torsion, and elasticity. Numerical results are computed from a discontinuous high-order spectral element flow solver. The flow rate used in this study is physiological. We observe differences in secondary flow patterns, especially during the deceleration phase of the physiological waveform where multiple vortical structures of both Dean-type and Lyne-type coexist. The results indicate that decreased axial velocities under an undeveloped condition produce smaller secondary flows that ultimately inhibit growth of any interior flow vortices. We highlight the effect of the entrance condition on the formation of these structures and subsequent appearance of abnormal inner wall shear stresses, which suggest there may be a lower prevalence of cardiovascular disease in curved arteries where the flow is rather undeveloped—a potentially physiologically significant result to help understand the influence of blood flow development on disease.

60 APPLIED LIFE SCIENCES↗

A centrifugal microfluidic cross-flow filtration platform to separate serum from whole blood for the detection of amphiphilic biomarkers

Abstract The separation of biomarkers from blood is straightforward in most molecular biology laboratories. However, separation in resource-limited settings, allowing for the successful removal of biomarkers for diagnostic applications, is not always possible. The situation is further complicated by the need to separate hydrophobic signatures such as lipids from blood. Herein, we present a microfluidic device capable of centrifugal separation of serum from blood at the point of need with a system that is compatible with biomarkers that are both hydrophilic and hydrophobic. The cross-flow filtration device separates serum from blood as efficiently as traditional methods and retains amphiphilic biomarkers in serum for detection.

59 BASIC BIOLOGICAL SCIENCES↗

A Poisson equation method for prescribing fully developed non-Newtonian inlet conditions for computational fluid dynamics simulations in models of arbitrary cross-section

Prescribing inlet boundary conditions for computational fluid dynamics (CFD) simulations of internal flow in complex geometries such as anatomical vascular models is challenging. In the absence of patient-specific inlet velocity data, a common approach for long blood vessels is to assume that the inlet flow is fully developed. In vessels of irregular cross section, however, prescribing fully developed conditions is complicated due to the lack of a general closed-form analytical solution. In this study, we develop a simple Poisson equation method for prescribing fully developed inlet conditions for the flow of either Newtonian or non-Newtonian fluids in CFD models of arbitrary cross-section. We first derive the generalized Poisson equation for fully developed flow of a non-Newtonian fluid and we then develop and verify a methodology for numerically computing the solution on any planar boundary domain. In addition, we develop a simple extension of the method for prescribing a non-orthogonal inlet velocity that represents fully developed flow from an upstream tube that is connected to the CFD inlet at a non-orthogonal angle. This may be used to investigate a common source of uncertainty in CFD simulations of internal flow that is due to a lack of information concerning the exact streamwise flow direction at the inlets. Comparison to several Newtonian and non-Newtonian benchmark verification solutions shows the method to be extremely accurate. As a practical demonstration case, we use the method to prescribe fully developed conditions on multiple non-circular inlets for the non-Newtonian flow of blood in a patient-specific model of the inferior vena cava (IVC). Finally, we further demonstrate the utility of the method by performing a sensitivity study using the patient-specific IVC model, wherein we investigate the influence of inlet velocity flow direction on the non-Newtonian IVC hemodynamics. Given its simplicity and computational efficiency, the method is shown to be far superior to alternative approaches for prescribing fully developed inlet conditions in such complicated geometries. In conclusion, to facilitate the adoption of our Poisson equation method, we have distributed our OpenFOAM source code and the associated test cases from this study as open-source software.

97 MATHEMATICS AND COMPUTING↗

Circulating SARS-CoV-2 + megakaryocytes are associated with severe viral infection in COVID-19

Several independent lines of evidence suggest that megakaryocytes are dysfunctional in severe COVID-19. Herein, we characterized peripheral circulating megakaryocytes in a large cohort of inpatients with COVID-19 and correlated the subpopulation frequencies with clinical outcomes. Using peripheral blood, we show that megakaryocytes are increased in the systemic circulation in COVID-19, and we identify and validate S100A8/A9 as a defining marker of megakaryocyte dysfunction. We further reveal a subpopulation of S100A8/A9 + megakaryocytes that contain severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) protein and RNA. Using flow cytometry of peripheral blood and in vitro studies on SARS-CoV-2–infected primary human megakaryocytes, we demonstrate that megakaryocytes can transfer viral antigens to emerging platelets. Mechanistically, we show that SARS-CoV-2–containing megakaryocytes are nuclear factor κB (NF-κB)-activated, via p65 and p52; express the NF-κB–mediated cytokines interleukin-6 (IL-6) and IL-1β; and display high surface expression of Toll-like receptor 2 (TLR2) and TLR4, canonical drivers of NF-κB. In a cohort of 218 inpatients with COVID-19, we correlate frequencies of megakaryocyte subpopulations with clinical outcomes and show that SARS-CoV-2–containing megakaryocytes are a strong risk factor for mortality and multiorgan injury, including respiratory failure, mechanical ventilation, acute kidney injury, thrombotic events, and intensive care unit admission. Furthermore, we show that SARS-CoV-2 + megakaryocytes are present in lung and brain autopsy tissues from deceased donors who had COVID-19. To our knowledge, this study offers the first evidence implicating SARS-CoV-2 + peripheral megakaryocytes in severe disease and suggests that circulating megakaryocytes warrant investigation in inflammatory disorders beyond COVID-19.

60 APPLIED LIFE SCIENCES↗

The effect of blood viscosity on shear‐induced hemolysis using a magnetically levitated shearing device

Abstract Introduction Blood contacting medical devices, including rotary blood pumps, can cause shear‐induced blood damage that may lead to adverse effects in patients. Due in part to an inadequate understanding of how cell‐scale fluid mechanics impact red blood cell membrane deformation and damage, there is currently not a uniformly accepted engineering model for predicting blood damage caused by complex flow fields within ventricular assist devices (VADs). Methods We empirically investigated hemolysis in a magnetically levitated axial Couette flow device typical of a rotary VAD. The device is able to accurately control the shear rate and exposure time experienced by blood and to minimize the effects of other uncharacterized stresses. Using this device, we explored the effects of both hematocrit and plasma viscosity on shear‐induced hemolysis to characterize blood damage based on the viscosity‐independent shear rate, rather than on shear stress. Results Over a shear rate range of 20 000 – 80 000 1/s, the Index of Hemolysis (IH) was found to be dependent upon and well‐predicted by the shear rate alone. IH was independent of hematocrit, bulk viscosity, or the suspension media viscosity and less correlated to shear stress (MSE = 0.46–0.75) than to shear rate (MSE = 0.06–0.09). Conclusion This study recommends that future investigations of shear‐induced blood damage report findings with respect to the viscosity‐neutral term of shear rate, in addition to the bulk whole blood viscosity measured at an appropriate shear rate relevant to the flow conditions of the device.

Krisher, James A.↗

Stress Birth and Death: Disruptive Computational Mechanics and Novel Diagnostics for Fluid-to-Solid Transitions

Many materials of interest to Sandia transition from fluid to solid or have regions of both phases coexisting simultaneously. Currently there are, unfortunately, no material models that can accurately predict this material response. This is relevant to applications that "birth stress" related to geoscience, nuclear safety, manufacturing, energy production and bioscience. Accurately capturing solidification and residual stress enables fully predictive simulations of the evolving front shape or final product. Accurately resolving flow of proppants or blood could reduce environmental impact or lead to better treatments for heart attacks, thrombosis, or aneurism. We will address a science question in this proposal: When does residual stress develop during the critical transition from liquid to solid and how does it affect material deformation? Our hypothesis is that these early phases of stress development are critical to predictive simulation of material performance, net shape, and aging. In this project, we use advanced constitutive models with yield stress to represent both fluid and solid behavior simultaneously. The report provides an abbreviated description of the results from our LDRD "Stress Birth and Death: Disruptive Computational Mechanics and Novel Diagnostics for Fluid-to-Solid Transitions," since we have written four papers that document the work in detail and which we reference. We give highlights of the work and describe the gravitationally driven flow visualization experiment on a model yield stress fluid, Carbopol, at various concentrations and flow rates. We were able to collapse the data on a single master curve by showing it was self-similar. We also describe the Carbopol rheology and the constitutive equations of interest including the Bingham-Carreau-Yasuda model, the Saramito model, and the HB-Saramito model including parameter estimation for the shear and oscillatory rheology. We present several computational models including the 3D moving mesh simulations of both the Saramito models and Bingham-Carreau-Yasuda (BCY) model. We also show results from the BCY model using a 3D level set method and two different ways of handling reduced order Hele-Shaw modeling for generalized Newtonian fluids. We present some first ever two-dimensional results for the modified Jeffries Kamani-Donley-Rogers constitutive equation developed during this project. We include some recent results with a successful Saramito-level set coupling that allows us to tackle problems with complex geometries like mold filling in a thin gap with an obstacle, without the need for remeshing or remapping. We report on some experiments for curing systems where fluorescent particles are used to track material flow. These experiments were carried out in an oven on Sylgard 184 as a model polymerizing system. We conclude the report with a summary of accomplishments and some thoughts on follow-on work.

36 MATERIALS SCIENCE↗

Circulating Tumour Cell Numbers Correlate with Platelet Count and Circulating Lymphocyte Subsets in Men with Advanced Prostate Cancer: Data from the ExPeCT Clinical Trial (CTRIAL-IE 15-21)

Interactions between circulating tumour cells (CTCs) and platelets are thought to inhibit natural killer(NK)-cell-induced lysis. We attempted to correlate CTC numbers in men with advanced prostate cancer with platelet counts and circulating lymphocyte numbers. Sixty-one ExPeCT trial participants, divided into overweight/obese and normal weight groups on the basis of a BMI ≥ 25 or <25, were randomized to participate or not in a six-month exercise programme. Blood samples at randomization, and at three and six months, were subjected to ScreenCell filtration, circulating platelet counts were obtained, and flow cytometry was performed on a subset of samples (n = 29). CTC count positively correlated with absolute total lymphocyte count (r 2 = 0.1709, p = 0.0258) and NK-cell count (r 2 = 0.49, p < 0.0001). There was also a positive correlation between platelet count and CTC count (r 2 = 0.094, p = 0.0001). Correlation was also demonstrated within the overweight/obese group (n = 123, p < 0.0001), the non-exercise group (n = 79, p = 0.001) and blood draw samples lacking platelet cloaking (n = 128, p < 0.0001). By flow cytometry, blood samples from the exercise group (n = 15) had a higher proportion of CD3+ T-lymphocytes (p = 0.0003) and lower proportions of B-lymphocytes (p = 0.0264) and NK-cells (p = 0.015) than the non-exercise group (n = 14). These findings suggest that CTCs engage in complex interactions with the coagulation cascade and innate immune system during intravascular transit, and they present an attractive target for directed therapy at a vulnerable stage in metastasis.

60 APPLIED LIFE SCIENCES↗

Determining critical overlap concentration of polyethylene oxide to support excipient safety assessment of opioid products

Intravenous administration of abuse-deterrent opioid products poses high safety risks, in part due to the presence of high molecular weight polymeric excipients. Previous in vivo studies in animal models have shown that the higher molecular weight (Mw) polymeric excipients like polyethylene oxide (PEO) were directly linked to such adverse responses as intravenous hemolysis and kidney damage. PEO polymers have been widely used in abuse-deterrent formulations (ADF) of opioid products, adding to concerns over the general safety of the opioid category due to the unknown safety risk from abuse via unintended routes. Here, the current study focused on the determination of the critical overlap concentration (c*) at various PEO molecular weights to aid in explaining differences in observed adverse responses from previous animal studies on the intravenous administration of PEO solutions. Adverse in vivo responses may be related to the viscoelastic regime of the polymer solution, which depends not only on Mw but also on concentration. Having a localized polymer concentration in the blood above the c*, i.e., the transition from the dilute to semi-dilute entangled viscoelastic regime, may influence the flow behavior and interactions of cells in the blood. The relationship of c* to this combination of physical, chemical, and rheological effects is a possible driving force behind adverse in vivo responses.

60 APPLIED LIFE SCIENCES↗

Go with the flow: modeling unique biological flows in engineered in vitro platforms

Interest in recapitulating in vivo phenomena in vitro using organ-on-a-chip technology has grown rapidly and with it, attention to the types of fluid flow experienced in the body has followed suit. These platforms offer distinct advantages over in vivo models with regards to human relevance, cost, and control of inputs (e.g., controlled manipulation of biomechanical cues from fluid perfusion). Given the critical role biophysical forces play in several tissues and organs, it is therefore imperative that engineered in vitro platforms capture the complex, unique flow profiles experienced in the body that are intimately tied with organ function. In this review, we outline the complex and unique flow regimes experienced by three different organ systems: blood vasculature, lymphatic vasculature, and the intestinal system. Here, we highlight current state-of-the-art platforms that strive to replicate physiological flows within engineered tissues while introducing potential limitations in current approaches.

42 ENGINEERING↗

Comparison of animal and human blood for in vitro dynamic thrombogenicity testing of biomaterials

Abstract Background To determine suitable alternatives to human blood for in vitro dynamic thrombogenicity testing of biomaterials, four different animal blood sources (ovine, bovine, and porcine blood from live donors, and abattoir porcine blood) were compared to fresh human blood. Methods To account for blood coagulability differences between individual donors and species, each blood pool was heparinized to a donor‐specific concentration immediately before testing in a dynamic flow loop system. The target heparin level was established using a static thrombosis pre‐test. For dynamic testing, whole blood was recirculated at room temperature for 1 h at 200 ml/min through a flow loop containing a single test material. Four materials with varying thrombotic potentials were investigated: latex (positive control), polytetrafluoroethylene (PTFE) (negative control), silicone (intermediate thrombotic potential), and high‐density polyethylene (HDPE) (historically thromboresistant). Thrombus weight and surface area coverage on the test materials were quantified, along with platelet count reduction in the blood. Results While donor‐specific heparin levels varied substantially from 0.6 U/ml to 7.0 U/ml among the different blood sources, each source was able to differentiate between the thrombogenic latex and the thromboresistant PTFE and HDPE materials ( p < 0.05). However, only donor ovine and bovine blood were sensitive enough to differentiate an increased response for the intermediate thrombotic silicone material compared to PTFE and HDPE. Conclusions These results demonstrated that multiple animal blood sources (particularly donor ovine and bovine blood) may be suitable alternatives to fresh human blood for dynamic thrombogenicity testing when appropriate control materials and donor‐specific anticoagulation levels are used.

Engineering↗

Biomimetic Rebuilding of Multifunctional Red Blood Cells: Modular Design Using Functional Components

The design and synthesis of artificial materials that mimic the structures, mechanical properties, and ultimately functionalities of biological cells remains a current holy grail of materials science. Here based on a silica cell bio-replication approach, we report the design and construction of synthetic rebuilt red blood cells (RRBCs) that fully mimic the broad properties of native RBCs: size, biconcave shape, deformability, oxygen carrying capacity, long circulation time. Four successive nano-scale processing steps: RBC bioreplication, layer-by-layer polymer deposition, and precision silica etching, followed by RBC ghost membrane vesicles fusion are employed for RRBC construction. A panel of physicochemical analyses including zeta potential measurement, fluorescence microscopy, and antibody-mediated agglutination assay proved the recapitulation of RBC shape, size, and membrane structure. Flow-based deformation studies carried out in a microfluidic blood capillary model confirrned the ability of RRBCs to deform and pass through small slits and reconstitute themselves in a manner comparable to native RBCs. Circulation studies of RRBCs conducted ex-ovo in a chick embryo and in vivo in a mouse model demonstrated the requirement of both deformability and native cell membrane surface to achieve long-term circulation. To confer additional non-native functionalities to RRBCs, we developed modular procedures in which to load functional cargos such as hemoglobin, drugs, magnetic nanoparticles, and ATP biosensors within the RRBC interior to enable various functions, including oxygen delivery, therapeutic drug delivery, magnetic manipulation, and toxin biosensing and detection. Taken together, RRBCs represent a class of long circulating RBC-inspired artificial hybrid materials with a broad range of potential applications.

59 BASIC BIOLOGICAL SCIENCES↗

Flow balancing devices, methods, and systems

The disclosed subject matter relates to extracorporeal blood processing or other processing of fluids. Volumetric fluid balance, a required element of many such processes, may be achieved with multiple pumps or other proportioning or balancing devices which are to some extent independent of each other. This need may arise in treatments that involve multiple fluids. Safe and secure mechanisms to ensure fluid balance in such systems are described.

Burbank, Jeffrey H.↗

Enhanced phagocytosis and complement-mediated killing of Mannheimia haemolytica serotype 1 following in-frame CMP-sialic acid synthetase ( neuA ) gene deletion

ABSTRACT Mannheimia haemolyticais the most significant bacterial pathogen associated with the bovine respiratory disease complex. Although sialic acid is a known virulence factor in other members of Pasteurellaceae, such asHistophilus somniandPasteurella multocida, the significance of sialic acid to the virulence ofM. haemolyticais currently unknown. Therefore, the role of sialic acid as a virulence determinant ofM. haemolyticawas investigated by constructing an in-frameneuA[CMP-N-acetylneuraminic acid (Neu5Ac/sialic) synthetase] mutant, which was shown by high-performance anion exchange chromatographic analysis (HPAEC) to be devoid of sialic acid on the lipopolysaccharide (LPS). Both theneuAmutant and wild-type parent strains exhibited similar growth rates in the growth curve assay. Real-time qPCR and ELISA evaluation showed no differences in proinflammatory cytokine expressions (IL-1β, IL-6, and IL-8) between theneuAmutant and parent strain when peripheral blood mononuclear cells were incubated with LPS. Interestingly, theneuAmutant was three to four logs more sensitive to a whole-blood bacterial killing assay than the parent strain. Similar results were also observed in plasma and serum bacterial killing assays. Flow cytometry analyses showed higher uptake ofneuAmutant by phagocytes, compared to the parent strain, in the whole-blood phagocytosis assay; however, no difference in reactive oxygen species production in neutrophils or monocytes was detected for either strain. Taken together, these results indicate that sialylation ofM. haemolyticaLPS plays a vital role in reducing complement-mediated and phagocytic killing. IMPORTANCE The Gram-negative coccobacillusMannheimia haemolyticais a natural inhabitant of the upper respiratory tract in ruminants and the most common bacterial agent involved in bovine respiratory disease complex development. Key virulence factors harbored byM. haemolyticaare leukotoxin, lipopolysaccharide, capsule, adhesins, and neuraminidase which are involved in evading innate and adaptive immune responses. In this study, we have shown that CMP-sialic acid synthetase (neuA) is necessary for the incorporation of sialic acid onto the membrane, and inactivation ofneuAresults in increased phagocytosis and complement-mediated killing ofM. haemolytica,thus demonstrating that sialylation contributes to the virulence ofM. haemolytica.

Microbiology↗

Heterogeneity of neutrophils in arterial hypertension

Highlights: • Normal-density and low-density neutrophils from patients with hypertension influx more Na{sup +} compared to normotensive individuals. • Normal-density neutrophils from patients with hypertension generate low levels of reactive oxygen species. • Normal-density and low-density neutrophils from patients with hypertension exhibit lower levels of apoptosis. • Normal-density neutrophils from patients with hypertension maintain an activated and degranulated phenotype. • Low-density neutrophils from patients with hypertension show atypical mitochondrial morphology. Cellular heterogeneity and diversity are recognized to contribute to the functions of neutrophils under homeostatic and pathological conditions. We previously suggested that the chronic inflammatory responses associated with hypertension (HTN) are related to the participation of different subpopulations of neutrophils. Two populations of neutrophils can be obtained by density gradient centrifugation: normal-density neutrophils (NDN) and low-density neutrophils (LDN). However, the lack of standardized functional protocols has limited phenotypic characterization and functional comparisons of LDN and NDN. Based on their capability to incorporate Na{sup +}, maturity and activation stage, we characterized NDN and LDN in blood samples from ten patients with HTN and ten healthy individuals (HI) using flow cytometry. We compared the levels of reactive oxygen species (ROS), generation of neutrophil extracellular traps (NETs) and levels of apoptosis in NDN and LDN. In general, the NDN and LDN subpopulations from patients with HTN exhibited higher levels of sodium influx and ROS, and lower levels of apoptosis than the corresponding NDN and LDN subsets from HI. Transmission electron microscopy revealed NDN and LDN from patients with HTN exhibited alterations to mitochondrial morphology and fewer cytoplasmic granules than the corresponding HI subpopulations. Our results indicate both the NDN and LDN subpopulations enhance the effects of inflammation that contribute to the pathophysiology of HTN. Further detailed studies are required to characterize the events during ontogeny of the myeloid lineage that result in the diverse phenotypic characteristics of each subpopulation of LDN and NDN.

60 APPLIED LIFE SCIENCES↗

Image transformers for classifying acute lymphoblastic leukemia

Cancer is the leading cause of death by disease in American children. Each year, nearly 16,000 children in the United States and over 300,000 children globally are diagnosed with cancer. Leukemia is a form of blood cancer that originates in the bone marrow and accounts for one-third of pediatric cancers. This disease occurs when the bone marrow contains 20% or more immature white blood cell blasts. Acute lymphoblastic leukemia is the most prevalent leukemia type found in children, with half of all annual cases in the U.S. diagnosed for subjects under 20 years of age. To diagnose acute lymphoblastic leukemia, pathologists often conduct a morphological bone marrow assessment. This assessment determines whether the immature white blood cell blasts in bone marrow display the correct morphological characteristics, such as size and appearance of nuclei. Pathologists also use immunophenotyping via multi-channel flow cytometry to test whether certain antigens are present on the surface of blast cells; the antigens are used to identify the cell lineage of acute lymphoblastic leukemia. These manual processes require well-trained personnel and medical professionals, thus being costly in time and expenses. Computerized decision support via machine learning can accelerate the diagnosis process and reduce the cost. Training a reliable classification model to distinguish between mature and immature white blood cells is essential to the decision support system. Here, we adopted the Vision Transformer model to classify white blood cells. The Vision Transformer achieved superb classification performance compared to state-of-the-art convolutional neural networks while requiring less computational resources for training. Additionally, the latent self-attention architecture provided attention maps for a given image, providing clues as to which portion(s) of the image were significant in decision-making. We applied the Vision Transformer model and a convolutional neural network model to an acute lymphoblastic leukemia classification dataset of 12,528 samples and achieved accuracies of 88.4% and 86.2%.

Cho, Priscilla↗

Tungsten disulfide nanotubes enhance flow-induced crystallization and radio-opacity of polylactide without adversely affecting in vitro toxicity

Treatment of vascular disease, from peripheral ischemia to coronary heart disease (CHD), is poised for transformation with the introduction of transient implants designed to “scaffold” regeneration of blood vessels and ultimately leave nothing behind. Improved materials could expand the use of these devices. Here, we examine one of the leading polymers for bioresorbable scaffolds (BRS), polylactide (PLA), as the matrix of nanocomposites with tungsten disulfide (WS 2 ) nanotubes (WSNT), which may provide mechanical reinforcement and enhance radio-opacity. We evaluate in vitro cytotoxicity using vascular cells, flow-induced crystallization and radio-opacity of PLA-WSNT nanocomposites at low WSNT concentration. A small amount of WSNT (0.1 wt%) can effectively promote oriented crystallization of PLA without compromising molecular weight. And radio-opacity improves significantly: as little as 0.5 to 1 wt% WSNT doubles the radio-opacity of PLA-WSNT relative to PLA at 17 keV. The results suggest that a single component, WSNT, has the potential to increase the strength of BRS to enable thinner devices and increase radio-opacity to improve intraoperative visualization. Here, the in vitro toxicity results indicate that PLA-WSNT nanocomposites are worthy of investigation in vivo. Although substantial further preclinical studies are needed, PLA-WSNT nanocomposites may provide a complement of material properties that may improve BRS and expand the range of lesions that can be treated using transient implants.

36 MATERIALS SCIENCE↗

In vitro activity and in vivo efficacy of omadacycline against Plasmodium species

Abstract Background Doxycycline is currently the only tetracycline-class antibiotic recommended for malaria prophylaxis. Omadacycline, a semisynthetic aminomethylcycline approved for treatment of adults with community-acquired bacterial pneumonia and acute bacterial skin and skin structure infections, has a well-established safety profile. This study evaluated the in vitro activity of omadacycline againstPlasmodium falciparumandPlasmodium cynomolgiand its in vivo efficacy againstPlasmodium bergheiin experimental malaria models to assess its potential as an antimalarial drug. Methods Fluorescence-based assays were used to assess the in vitro blood and liver stage activity of omadacycline and doxycycline againstP. falciparumandP. cynomolgilaboratory clones. In vivo liver and early-stage blood stage efficacy were evaluated in a murine model ofP. bergheiinfection, utilizing in vivo imaging of luciferase-expressingP. berghei(ANKA strain) sporozoites in female albino C57Bl/6 mice. Parasitaemia was monitored by flow cytometry for up to 30 days post-infection. Results Omadacycline demonstrated comparable in vitro activity to doxycycline against both drug-sensitive and drug-resistantP. falciparumclones, while doxycycline showed reduced activity against two drug-resistant clones. Notably, omadacycline exhibited superior anti-schizont activity in theP. cynomolgiliver stage assay. In theP. bergheimurine model, omadacycline was efficacious in both liver and early blood stages compared to the untreated control group, and demonstrated improved survival compared to doxycycline. Conclusions Omadacycline demonstrated enhanced antimalarial efficacy over doxycycline in vitro in liver stage activity and in overcoming resistance in the blood stage, and in survival in an in vivo model ofP. bergheiinfection. These findings support further investigation of omadacycline as a potential candidate for malaria prophylaxis and treatment.

Infectious Diseases↗

Extreme elevational migration spurred cryptic speciation in giant hummingbirds

The ecoevolutionary drivers of species niche expansion or contraction are critical for biodiversity but challenging to infer. Niche expansion may be promoted by local adaptation or constrained by physiological performance trade-offs. For birds, evolutionary shifts in migratory behavior permit the broadening of the climatic niche by expansion into varied, seasonal environments. Broader niches can be short-lived if diversifying selection and geography promote speciation and niche subdivision across climatic gradients. To illuminate niche breadth dynamics, we can ask how “outlier” species defy constraints. Of the 363 hummingbird species, the giant hummingbird (Patagona gigas) has the broadest climatic niche by a large margin. To test the roles of migratory behavior, performance trade-offs, and genetic structure in maintaining its exceptional niche breadth, we studied its movements, respiratory traits, and population genomics. Satellite and light-level geolocator tracks revealed an >8,300-km loop migration over the Central Andean Plateau. This migration included a 3-wk, ~4,100-m ascent punctuated by upward bursts and pauses, resembling the acclimatization routines of human mountain climbers, and accompanied by surging blood-hemoglobin concentrations. Extreme migration was accompanied by deep genomic divergence from high-elevation resident populations, with decisive postzygotic barriers to gene flow. The two forms occur side-by-side but differ almost imperceptibly in size, plumage, and respiratory traits. The high-elevation resident taxon is the world’s largest hummingbird, a previously undiscovered species that we describe and name here. The giant hummingbirds demonstrate evolutionary limits on niche breadth: when the ancestral niche expanded due to evolution (or loss) of an extreme migratory behavior, speciation followed.

Science & Technology - Other Topics↗