At least 55 records · Page 3

Results of The Excreta Bioassay Quality Control Program For April 1, 2010 Through March 31, 2011

A total of 76 urine samples and 10 spiked fecal samples were submitted during the report period (April 1, 2010 through March 31, 2011) to GEL Laboratories, LLC in South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for 14C, Sr, for 238 Pu, 239 Pu, 241 Am, 243 Am, 235U, 238U, 238U-mass and fecal analyses for 241Am, 238 Pu and 239 Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.1% of the total samples submitted.

61 RADIATION PROTECTION AND DOSIMETRY↗

Results of the Excreta Bioassay Quality Control Program For April 1, 2006 Through March 31, 2007

A total of 66 urine samples, 6 blank fecal and 6 spiked artificial fecal samples were submitted during the report period (April 1, 2006 through March 31, 2007) to General Engineering Laboratories, South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for tritium, Sr, 238Pu, 239Pu, 241Am, 243Am 235U, 238U, elemental uranium and fecal analyses for 241Am, 238Pu and 239Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.7% of the total samples submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 36% of the analyses processed by GEL during the second year of this contract were quality control samples. GEL tested the performance of 16 radioisotopes, all of which met or exceeded the specifications in the Statement of Work. IDP concluded that GEL was performing well for all analyses tested, and concerns identified earlier were satisfactorily resolved.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Results Of The Excreta Bioassay Quality Control Program For April 1, 2007 Through March 31, 2008

A total of 79 urine samples, 3 blank fecal and 5 spiked artificial fecal samples were submitted during the report period (April 1, 2007 through March 31, 2008) to General Engineering Laboratories, South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for tritium, Sr, 238Pu, 239Pu, 241Am, 243Am 235U, 238U, elemental uranium and fecal analyses for 241Am, 238Pu and 239Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.8% of the total samples submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 35% of the analyses processed by GEL during the third year of this contract were quality control samples. GEL tested the performance of 24 radioisotopes, all of which met or exceeded the specifications in the Statement of Work within statistical uncertainty (Table 4). IDP concluded that GEL was performing well for all analyses tested, and concerns identified earlier were satisfactorily resolved.

61 RADIATION PROTECTION AND DOSIMETRY↗

Synthesis and bioassay of a new class of disubstituted 1,3,4-oxadiazoles, 1,3,4-thiadiazoles and 1,2,4-triazoles

A new class of aroylethenesulfonylmethyl styryl oxadiazoles/thiadiazoles/triazoles and arylsulfonylethenesulfonylmethyl styryl oxadiazoles/thiadiazoles/triazoles were synthesized from the synthetic intermediates E-aroylethenesulfonylacetic acid methyl ester, E-arylsulfonylethenesulfonylacetic acid methyl ester and substituted cinnamic acids adopting conventional and ultrasonication methodologies. All the synthesized compounds were obtained in higher yields and in shorter reaction times in ultrasound irradiation method when compared with conventional method. The structures of all the compounds were characterized by IR, {sup 1}H NMR, {sup 13}C NMR and mass spectra. All the title compounds were tested for antimicrobial activity. The arylsulfonylethenesulfonylmethyl styryl azoles displayed higher antimicrobial activity than the aroylethenesulfonylmethyl styryl azoles. The compounds having triazole moiety showed greater activity than those with oxadiazole and thiadiazole. Amongst all the tested compounds unsubstituted and chloro substituted arylsulfonylethenesulfonyl methyl styryl triazoles are identified as potential antimicrobial agents particularly against B. subtilis and P.chrysogenum. .

60 APPLIED LIFE SCIENCES↗

Lung response to coarse PM: Bioassay in mice

Particulate matter (PM) elicits inflammatory and toxic responses in the lung specific to its constituents, which can vary by region, time, and particle size. To identify the mechanism of toxicity in PM collected in a rural area in the San Joaquin Valley of Central California, we studied coarse particles of 2.5-10 {mu}m diameter (PM{sub 2.5}-PM{sub 10}). Potential pro-inflammatory and toxic effects of PM{sub 2.5}-PM{sub 10} in the lung were investigated using intratracheally instilled mice. We determined total and differential cell profiles and inflammatory chemokines in lung lavage fluid, and biomarkers of toxicity resulting from coarse PM exposure. Responses of the mice were readily observed with total doses of 25-50 {mu}g of PM per mouse. Changes in pro-inflammatory cellular profiles and chemokines showed both dose and time responses; peak responses were observed 24 h after PM instillation, with recovery as early as 48 h. Furthermore, macrophage inflammatory protein (MIP-2) profiles following PM exposures were correlated to levels of measured macrophages and neutrophils recovered from lung lavage fluid of PM-treated animals. Our data suggest that pro-inflammatory effects observed from coarse PM collected during the summer months from California's hot and dry Central Valley are driven largely by the insoluble components of the PM mixture, and are not caused by endotoxin.

60 APPLIED LIFE SCIENCES↗

Profiling of benzophenone derivatives using fish and human estrogen receptor-specific in vitro bioassays

Benzophenone (BP) derivatives, BP1 (2,4-dihydroxybenzophenone), BP2 (2,2',4,4'-tetrahydroxybenzophenone), BP3 (2-hydroxy-4-methoxybenzophenone), and THB (2,4,4'-trihydroxybenzophenone) are UV-absorbing chemicals widely used in pharmaceutical, cosmetics, and industrial applications, such as topical sunscreens in lotions and hair sprays to protect skin and hair from UV irradiation. Studies on their endocrine disrupting properties have mostly focused on their interaction with human estrogen receptor alpha (hER{alpha}), and there has been no comprehensive analysis of their potency in a system allowing comparison between hER{alpha} and hER{beta} activities. The objective of this study was to provide a comprehensive ER activation profile of BP derivatives using ER from human and fish origin in a battery of in vitro tests, i.e., competitive binding, reporter gene based assays, vitellogenin (Vtg) induction in isolated rainbow trout hepatocytes, and proliferation based assays. The ability to induce human androgen receptor (hAR)-mediated reporter gene expression was also examined. All BP derivatives tested except BP3 were full hER{alpha} and hER{beta} agonists (BP2 > THB > BP1) and displayed a stronger activation of hER{beta} compared with hER{alpha}, the opposite effect to that of estradiol (E{sub 2}). Unlike E{sub 2}, BPs were more active in rainbow trout ER{alpha} (rtER{alpha}) than in hER{alpha} assay. All four BP derivatives showed anti-androgenic activity (THB > BP2 > BP1 > BP3). Overall, the observed anti-androgenic potencies of BP derivatives, together with their proposed greater effect on ER{beta} versus ER{alpha} activation, support further investigation of their role as endocrine disrupters in humans and wildlife.

60 APPLIED LIFE SCIENCES↗

SERS as a bioassay platform: fundamentals, design, and applications

Bioanalytical science is experiencing a period of unprecedented growth. Drivers behind this growth include the need to detect markers central to human and veterinary diagnostics at ever-lower levels and greater speeds. A set of parallel arguments applies to pathogens with respect to bioterrorism prevention and food and water safety. This tutorial review outlines our recent explorations on the use of surface enhanced Raman scattering (SERS) for detection of proteins, viruses, and microorganisms in heterogeneous immunoassays. It will detail the design and fabrication of the assay platform, including the capture substrate and nanoparticle-based labels. The latter, which is the cornerstone of our strategy, relies on the construction of gold nanoparticles modified with both an intrinsically strong Raman scatterer and an antibody. This labelling motif, referred to as extrinsic Raman labels (ERLs), takes advantage of the well-established signal enhancement of scatterers when coated on nanometre-sized gold particles, whereas the antibody imparts antigenic specificity. We will also examine the role of plasmon coupling between the ERLs and capture substrate, and challenges related to particle stability, nonspecific adsorption, and assay speed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Minimum Detectable Intakes and Doses for Uranium Bioassays—Comparison between Alpha Spectrometry and ICP-MS

Naturally occurring uranium complicates monitoring for occupational exposures. There are several retroactive methods that can be used to monitor for occupational exposures, with benefits and drawbacks to each. Analysis of uranium in urine by mass spectrometry and alpha spectrometry is compared, and methods of determining an occupational exposure are presented. Furthermore, the minimum detectable concentrations from each analysis and a method for intake determination based on the analytical results are compared for various solubility types and mixtures. Mass spectrometry with radiochemical separation was found to be the most sensitive analysis for detecting occupational exposures to anthropogenic mixtures based on minimum detectable doses calculated from the proposed method for intake determination.

bioassay↗

Results of the Excreta Bioassay Quality Control Program for April 1, 2009 through March 31, 2010

A total of 58 urine samples and 10 fecal samples were submitted during the report period (April 1, 2009 through March 31, 2010) to General Engineering Laboratories, South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for Sr, 238 Pu, 239 Pu, 241 Am, 243 Am 235 U, 238 U, elemental uranium and fecal analyses for 241 Am, 238 Pu and 239 Pu were tested this year as well as four tissue samples for 238 Pu, 239 Pu, 241 Am and 241 Pu. The number of QC urine samples submitted during the report period represented 1.3% of the total samples submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 33% of the analyses processed by GEL during the third year of this contract were quality control samples. GEL tested the performance of 21 radioisotopes, all of which met or exceeded the specifications in the Statement of Work within statistical uncertainty (Table 4).

61 RADIATION PROTECTION AND DOSIMETRY↗

Bioassay Monitoring at Los Alamos: A Guide for workers and their families

The purpose of this booklet is to help workers and their families understand how we monitor for a radionuclide intake and what to expect if we find one. The information given here explains the basics of radiation safety, the health effects of radiation, and the process of monitoring for and reporting radionuclide intakes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Los Alamos Radiation Protection Internal Dosimetry (Bioassay) Pamphlet

A radionuclide intake happens when a radioactive material enters the body through inhalation or ingestion or through a wound. Because the radiation produced by some materials (such as plutonium, americium, uranium, and tritium) cannot leave the body, we look for the materials themselves in urine samples.

61 RADIATION PROTECTION AND DOSIMETRY↗