Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM CURRENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

DEVELOPMENT OF ACCELERATOR DATA REPORTING SYSTEM AND ITS APPLICATION TO TREND ANALYSIS OF BEAM CURRENT DATA

Detailed ongoing information about the ion beam quality is crucial to the successful operation of the Spallation Neutron Source at Oak Ridge National Laboratory. In order to provide the highest possible neutron production time, ion beam quality is monitored to isolate possible problems or performance-related issues throughout the accelerator and accumulator ring. For example, beam current monitor (BCM) data is used to determine the quality of the beam transport through the accelerator. In this study, a reporting system infrastructure was implemented and used to generate a trend analysis report of the BCM data. The BCM data was analyzed to facilitate the identifi cation of monitor calibration issues, beam trends, beam abnormalities, beam deviations and overall beam quality. A comparison between transformed BCM report data and accelerator log entries shows promising results which represent correlations between the data and changes made within the accelerator. The BCM analysis report is one of many reports within a system that assist in providing overall beam quality information to facilitate successful beam operation. In future reports, additional data manipulation functions and analysis can be implemented and applied. Built-in and user-defi ned analytic functions are available throughout the reporting system and can be reused with new data.

Padilla, M J↗

Auger electron spectroscopy at high spatial resolution and nA primary beam currents

An experimental Auger microprobe system is described which incorporates a field-emission electron gun and total beam currents in the nanoampere range. The distinguishing characteristics of this system include a large multistation UHV specimen chamber, pulse counting and fully digital Auger signal-processing techniques, and digital referencing methods to eliminate the effects of beam instabilities. Some preliminary results obtained with this system are described, and it is concluded that field-emission electron sources can be used for high-resolution Auger electron spectroscopy with primary-beam spots of less than 100 nm and beam currents of the order of 1 nA.

Todd, G.↗

Direct fabrication of nanopores in a metal foil using focused ion beam with in situ measurements of the penetrating ion beam current

A through hole with a diameter less than 100 nm was fabricated in an Ag foil using only a focused ion beam (FIB) system and in situ measurements of the penetrating ion beam. During the drilling of the foil by a FIB of Ga{sup +} ions, the transmitted part of the beam was measured with an electrode mounted on the back face of the foil. When the beam current penetrating through the nanopore reached a certain value, irradiation was stopped and the area of the created aperture was measured with a scanning electron microscope. The resulting area was correlated with the current of the penetrating ion beam. This suggests that we can fabricate a nanopore of the desired size by controlling the ion beam via penetrating ion beam measurements. The smallest aperture thus created was circular with diameter of 30 nm.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Experimental Investigation and Validation of Neutral Beam Current Drive for ITER Through ITPA Joint Experiments

Joint experiments investigating the off-axis neutral beam current drive (NBCD) capability to be utilized for advanced operation scenario development in ITER were conducted in four tokamaks (ASDEX Upgrade (AUG), DIII-D, JT-60U and MAST) through the international tokamak physics activity (ITPA). The following results were obtained in the joint experiments, where the toroidal field, B(t), covered 0.4-3.7 T, the plasma current, I(p), 0.5-1.2 MA, and the beam energy, E(b), 65-350 keV. A current profile broadened by off-axis NBCD was observed in MAST. In DIII-D and JT-60U, the NB driven current profile has been evaluated using motional Stark effect diagnostics and good agreement between the measured and calculated NB driven current profile was observed. In AUG (at low delta similar to 0.2) and DIII-D, introduction of a fast-ion diffusion coefficient of D(b) similar to 0.3-0.5 m(2) s(-1) in the calculation gave better agreement at high heating power (5 MW and 7.2 MW, respectively), suggesting anomalous transport of fast ions by turbulence. It was found through these ITPA joint experiments that NBCD related physics quantities reasonably agree with calculations (with D(b) = 0-0.5 m(2) s(-1)) in all devices when there is no magnetohydrodynamic (MHD) activity except ELMs. Proximity of measured off-axis beam driven current to the corresponding calculation with D(b) = 0 has been discussed for ITER in terms of a theoretically predicted scaling of fast-ion diffusion that depends on E(b)/T(e) for electrostatic turbulence or beta(t) for electromagnetic turbulence.

Suzuki, T↗

Spatially-Resolved Beam Current and Charge-State Distributions for the NEXT Ion Engine

Plume characterization tests with the 36-cm NEXT ion engine are being performed at The Aerospace Corporation using engineering-model and prototype-model thrusters. We have examined the beam current density and xenon charge-state distribution as functions of position on the accel grid. To measure the current density ratio j++/j+, a collimated Eprobe was rotated through the plume with the probe oriented normal to the accel electrode surface at a distance of 82 cm. The beam current density jb versus radial position was measured with a miniature planar probe at 3 cm from the accel. Combining the j++/j+ and jb data yielded the ratio of total Xe+2 current to total Xe+1 current (J++/J+) at forty operating points in the standard throttle table. The production of Xe+2 and Xe+3 was measured as a function of propellant utilization to support performance and lifetime predictions for an extended throttle table. The angular dependence of jb was measured at intermediate and far-field distances to assist with plume modeling and to evaluate the thrust loss due to beam divergence. Thrust correction factors were derived from the total doubles-to-singles current ratio and from the far-field divergence data

Pollard, James E.↗

Routine {sup 18}F{sup -} production with 180 {mu}A to 200 {mu}A target beam current on a GE PETtrace 800 cyclotron

Through upgrades and enhancements, which are now standard on current PETtrace 800 cyclotrons, a GE PETtrace cyclotron installed in 2002 has demonstrated reliable routine [{sup 18}F]FDG production at total target beam currents of 180 {mu}A without detriment to saturation and [{sup 18}F]FDG yields. Routine production at 200 {mu}A has been achieved and its evaluation is continuing. Self-shielded target using W/Cu alloy for the target body afforded a reduction in dose rate from the Havar foils by a factor of {approx} 8-10, reducing dose from the targets and need for removing targets during maintenance. The main activation product in the shield is {sup 187}W (T1/2 24 h). The {sup 60}Co ((T1/2 5.3 y) activation is about 250 times less at 24 h post EOB and is not considered a major issue despite its long half-life.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Off-axis neutral beam current drive for advanced scenario development in DIII-D

Modification of the two existing DIII-D neutral beamlines is planned to allow vertical steering to provide off-axis neutral beam current drive (NBCD) peaked as far off-axis as half the plasma minor radius. New calculations for a downward-steered beam indicate strong current drive with good localization off-axis so long as the toroidal magnetic field, B-T, and the plasma current, I-p, point in the same direction. This is due to good alignment of neutral beam injection (NBI) with the local pitch of the magnetic field lines. This model has been tested experimentally on DIII-D by injecting equatorially mounted NBs into reduced size plasmas that are vertically displaced with respect to the vessel midplane. The existence of off-axis NBCD is evident in the changes seen in sawtooth behaviour in the internal inductance. By shifting the plasma upwards or downwards, or by changing the sign of the toroidal field, off-axis NBCD profiles measured with motional Stark effect data and internal loop voltage show a difference in amplitude (40-45%) consistent with differences predicted by the changed NBI alignment with respect to the helicity of the magnetic field lines. The effects of NBI direction relative to field line helicity can be large even in ITER: off-axis NBCD can be increased by more than 30% if the B-T direction is reversed. Modification of the DIII-D NB system will strongly support scenario development for ITER and future tokamaks as well as provide flexible scientific tools for understanding transport, energetic particles and heating and current drive.

Murakami, Masanori↗

A 128-channel picoammeter system and its application on charged particle beam current distribution measurements

A 128-channel picoammeter system is constructed based on instrumentation amplifiers. Taking advantage of a high electric potential and narrow bandwidth in DC energetic charged beam measurements, a current resolution better than 5 fA can be achieved. Two sets of 128-channel strip electrodes are implemented on printed circuit boards and are employed for ion and electron beam current distribution measurements. Tests with 60 keV O{sup 3+} ions and 2 keV electrons show that it can provide exact boundaries when a positive charged particle beam current distribution is measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, performance, and calculated error of a Faraday cup for absolute beam current measurements of 600-MeV protons

A mobile self-contained Faraday cup system for beam current measurments of nominal 600 MeV protons was designed, constructed, and used at the NASA Space Radiation Effects Laboratory. The cup is of reentrant design with a length of 106.7 cm and an outside diameter of 20.32 cm. The inner diameter is 15.24 cm and the base thickness is 30.48 cm. The primary absorber is commercially available lead hermetically sealed in a 0.32-cm-thick copper jacket. Several possible systematic errors in using the cup are evaluated. The largest source of error arises from high-energy electrons which are ejected from the entrance window and enter the cup. A total systematic error of -0.83 percent is calculated to be the decrease from the true current value. From data obtained in calibrating helium-filled ion chambers with the Faraday cup, the mean energy required to produce one ion pair in helium is found to be 30.76 + or - 0.95 eV for nominal 600 MeV protons. This value agrees well, within experimental error, with reported values of 29.9 eV and 30.2 eV.

Beck, S. M.↗

Dependence of ion beam current on position of mobile plate tuner in multi-frequencies microwaves electron cyclotron resonance ion source

We are constructing a tandem-type electron cyclotron resonance ion source (ECRIS). The first stage of this can supply 2.45 GHz and 11-13 GHz microwaves to plasma chamber individually and simultaneously. We optimize the beam current I{sub FC} by the mobile plate tuner. The I{sub FC} is affected by the position of the mobile plate tuner in the chamber as like a circular cavity resonator. We aim to clarify the relation between the I{sub FC} and the ion saturation current in the ECRIS against the position of the mobile plate tuner. We obtained the result that the variation of the plasma density contributes largely to the variation of the I{sub FC} when we change the position of the mobile plate tuner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Controlling precise magnetic field configuration around electron cyclotron resonance zone for enhancing plasma parameters and beam current

Multi-charged ion source which has wide operating conditions is required in various application fields. We have constructed tandem type ECR ion source (ECRIS); one of the features of its main stage is an additional coil for controlling magnetic field distribution around the mirror bottom precisely. Here the effect of magnetic field variation caused by the additional coil is experimentally considered in terms of plasma parameters and beam current as the first investigation of the main stage plasma. Furthermore, behavior of magnetic lines of force flowing from the ECR zone is calculated, and is compared with measurement results aiming for better understanding of interrelationship between plasma production and ion beam generation on the ECRIS.

43 PARTICLE ACCELERATORS↗

SU-E-T-08: A Beam Source Model for Monte Carlo Simulations of a Double-Scattering Proton Beam Delivery System Using Beam Current Modulation

Purpose: To reconstruct phase-space information upstream of patient specific collimators for Monte Carlo simulations using only radiotherapy planning system data. Methods: The proton energies are calculated based on residual ranges, e.g., sum of prescribed ranges in a patient and SSD. The Kapchinskij and Vladimirskij (KV) distribution was applied to sample proton’s x-y positions and momentum direction and the beam shape was assumed to be a circle. Free parameters, e.g., the initial energy spread and the emittance of KV distribution were estimated from the benchmarking with commissioning data in a commercial treatment planning system for an operational proton therapy center. The number of histories, which defines the height of individual pristine Bragg peaks (BP) of Spread-out Bragg peak (SOBP), are weighted based on beam current modulation and a correction factor is applied to take into account the fluence reduction as the residual range decreases due to the rotation of the range modulator wheel. The timedependent behaviors, e.g., the changes of the residual range and histories per a pristine BP, are realized by utilizing TOPAS (Tool for Particle Simulation). Results: Benchmarking simulations for selected SOBPs ranging 7.5 cm to 15.5 cm matched within 2 mm in range and up to 5 mm in SOBP width against measurement data in water phantom. We found this model tends to underestimate entrance dose by about 5 % in comparison to measurement. This was attributed to the situation that the energy distribution used in the model was limited in its granularity at the limit of single energy spectrum for the narrow angle modulator steps used in the proximal pull back region of the SOBPs. Conclusion: Within these limitations the source modeling method proved itself an acceptable alternative of a full treatment head simulation when the machine geometry and materials information are not available.

60 APPLIED LIFE SCIENCES↗

The influence of guiding magnetic field on beam current and plasma expansion in foil-less diode

The impedance collapse phenomenon in planar diodes has been widely investigated and is believed to be induced by the axial plasma expansion. However, there are few studies about the impedance collapse phenomenon in foil-less diodes, which may occur under a low guiding magnetic field and cannot be explained by the axial plasma expansion. This paper tries to explain this phenomenon by constructing a physical model with consideration of the radial expansion of cathode plasmas. Our physical model can quantitatively describe the formation process of beam current in experiments with reasonable parameters, and it demonstrates that a lower guiding magnetic field will lead to a faster radial plasma expansion speed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MHD stability trends and improved performance of LHD inward-shifted configurations: The role of the neutral beam current drive and thermal plasma density

The aim of the present study is to analyze the effect of the neutral beam current drive (NBCD), thermal plasma density, and NBI operational regime on the stability of pressure gradient-driven modes (PGDM) and Alfvén eigenmodes (AE) in LHD inward-shifted configurations. The stabilization of n/m = 1/2 PGDM (n toroidal mode and m poloidal mode) is observed in the discharge 167 800 during the co-NBCD phase. The iota profile evolution measured by motional stark effect diagnostic may indicate the iota profile up-shift caused by the co-NBCD can induce a non-resonant transition of the rational surface 1/2 before the mode stabilization. The evolution of the iota profile and continuum gaps in the discharge 167 805 during the ctr-NBCD phase leads to the stabilization of the AE, caused by the narrowing of the continuum gap as the iota profile down-shift. Opposite stability trends are identified for PGDM and AE stability with respect to the thermal plasma density. A larger thermal plasma density (larger thermal β) further enhances PGDM although the continuum gaps are narrower leading to configurations with stable AEs. The linear stability of AEs is analyzed using the gyro-fluid FAR3d code to reproduce the AE stability trends observed in the experiments with respect to the NBCD and thermal plasma density. The analysis of hypothetical scenarios dedicated to study different NBI operational regimes with respect to EP energy, and β and radial density profiles indicate off-axis NBI operation shows a higher EP β threshold to destabilize AEs compared to on-axis configuration. This is explained by the presence of a TAE gap in the inner plasma region, easily destabilized by an on-axis NBI injection. The control of the NBCD and thermal plasma in the discharge 167 800 shows a transitory stabilization of PGDM and AEs, as well as an improved discharge performance identified by an increment of the neutron fluxes.

Varela, Jacobo↗

Integration Development and Testing of Rear Transition Monitor for Beam Current Monitoring System

Addressing baseline effects in accelerator environments is crucial for accurate data acquisition and analysis, since baseline effects can obscure signal clarity and impact the reliability of beam current monitoring systems. There are many potential contributors to baseline noise, such as variations in beam dynamics, electromagnetic interference from nearby equipment, or RF interference. Previous applications of noise reduction systems don t sufficiently filter sources of asynchronous noise, so a new algorithm was implemented. A simulation dataset was created to replicate beam conditions and a Red Pitaya FPGA was used to collect data through the streaming application. A Python script was developed to implement noise reduction algorithms and efforts were made to integrate real-time data streaming with the Redis platform and Acnet Front End infrastructure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam current controller for laser ion source

The present invention relates to the design and use of an ion source with a rapid beam current controller for experimental and medicinal purposes. More particularly, the present invention relates to the design and use of a laser ion source with a magnetic field applied to confine a plasma flux caused by laser ablation.

42 ENGINEERING↗