Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM BENDING MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An RF beam sweeper for purifying in-flight produced secondary ion beams at ATLAS

A new large-acceptance RE beam sweeper was designed, constructed and put into operation with the goal to remove the energy-degraded primary beams tails from radioactive beams (RIB) produced by inflight transfer or charge-exchange reactions. The system makes use of the velocity difference between the RIB beam of interest and the remaining tails of the primary beam after momentum selection by a bending magnet. The time-delayed primary beam components are deflected vertically out of the beam path by the RF sweeper, significantly reducing the stable beam background. Beam purity for the in-flight radioactive ion beams as high as 96% has been achieved with this system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delivery of H - / H + Beams to Area A

We explore the relative merits of transporting the beam from the H + ion source and from the H - ion source to Area-A for low current applications. Transporting the H - beam to Area-A using the laser neutralization approach has some risk associated with it and will require some development. Alternative method of delivering H - beam to Area-A includes replacing LDBM00 bending magnet with kicker for sharing beam between Line D and modified Line A. Transporting the H + beam to Area-A will have significant impact on the operation the IPF facility and maintaining high pulse rate to IPF will require major modifications to the transition region of the accelerator and Drift Tube Linac.

43 PARTICLE ACCELERATORS↗

Using Polarimetry to Determine the CEBAF Beam Energy

As Jefferson Lab begins operations with its upgraded CEBAF a ccelerator, the lab once again needs to experimentally determine the absolute beam energy of the machine. Previously, the CE- BAF beam energy was determined using precision measurement s of the bending magnet integral fields along with beam position information. The result obta ined from this technique was cross- checked with elastic scattering from hydrogen where knowle dge of the scattering angles of the electron and proton allow the beam energy to be determined. Wh ile the field integral method will still work with the upgraded machine, the elastic cross sect ion becomes too small to make preci- sion measurements at angles that are large enough to be easil y accessible; thus a new technique for energy determination has been sought. It will be shown th at by making use of polarimetry, one can use CEBAF’s polarized electrons’ g-2 spin precessio n to determine the absolute beam energy. This can be done in a single hall if the parameters of t he machine, such as the injector energy and linac imbalance, are known or with two halls witho ut any knowledge of the machine parameters

Higinbotham, Douglas W.↗

SU-E-T-249: Determining the Sensitivity of Beam Profile Parameters for Detecting Energy Changes in Flattening Filter-Free Beams

Purpose: To identify the beam profile parameters that can be used to detect energy changes in a flattening filter-free photon beams. Methods: Flattening filter-free beam profiles (inline, crossline, and diagonals) were measured for multiple field sizes (25×25cm and 10×10cm) at 6MV on a clinical system (Truebeam, Varian Medical Systems Palo Alto CA). Profiles were acquired for baseline energy and detuned beams by changing the bending magnet current (BMC), above and below baseline. The following profile parameters were measured: flatness (off-axis ratio at 80% of field size), symmetry, uniformity, slope, and the off-axis ratio (OAR) at several off-axis distances. Tolerance values were determined from repeated measurements. Each parameter was evaluated for sensitivity to the induced beam changes, and the minimum detectable BMC change was calculated for each parameter by calculating the change in BMC that would Result in a change in the parameter above the measurement tolerance. Results: Tolerance values for the parameters were-Flatness≤0.1%; Symmetry≤0.4%; Uniformity≤0.01%; Slope≤ 0.001%/mm. The measurements made with a field size of 25cm and a depth of d=1.5cm showed the greatest sensitivity to bending magnet current variations. Uniformity had the highest sensitivity, able to detect a change in BMC of BMC=0.02A. The OARs and slope were sensitive to the magnitude and direction of BMC change. The sensitivity in the flatness parameter was BMC=0.04A; slope was sensitive to BMC=0.05A. The sensitivity decreased for OARs measured closer to central axis-BMC(8cm)=0.23A; BMC(5cm)=0.47A; BMC(2cm)=1.35A. Symmetry was not sensitive to changes in BMC. Conclusion: These tests allow for better QA of FFF beams by setting tolerance levels to beam parameter baseline values which reflect variations in machine calibration. Uniformity is most sensitive to BMC changes, while OARs provide information about magnitude and direction of miscalibration. Research funding provided by Varian Medical Systems. Dr. Sasa Mutic receives compensation for providing patient safety training services from Varian Medical Systems, the sponsor of this study.

60 APPLIED LIFE SCIENCES↗

Novel technique for spatially resolved imaging of molecular bond orientations using x-ray birefringence

Birefringence has been observed in anisotropic materials transmitting linearly polarized X-ray beams tuned close to an absorption edge of a specific element in the material. Synchrotron bending magnets provide X-ray beams of sufficiently high brightness and cross section for spatially resolved measurements of birefringence. The recently developed X-ray Birefringence Imaging (XBI) technique has been successfully applied for the first time using the versatile test beamline B16 at Diamond Light Source. Orientational distributions of the C–Br bonds of brominated “guest” molecules within crystalline “host” tunnel structures (in thiourea or urea inclusion compounds) have been studied using linearly polarized incident X-rays near the Br K-edge. Imaging of domain structures, changes in C–Br bond orientations associated with order-disorder phase transitions, and the effects of dynamic averaging of C–Br bond orientations have been demonstrated. The XBI setup uses a vertically deflecting high-resolution double-crystal monochromator upstream from the sample and a horizontally deflecting single-crystal polarization analyzer downstream, with a Bragg angle as close as possible to 45°. In this way, the ellipticity and rotation angle of the polarization of the beam transmitted through the sample is measured as in polarizing optical microscopy. The theoretical instrumental background calculated from the elliptical polarization of the bending-magnet X-rays, the imperfect polarization discrimination of the analyzer, and the correlation between vertical position and photon energy introduced by the monochromator agrees well with experimental observations. The background is calculated analytically because the region of X-ray phase space selected by this setup is sampled inefficiently by standard methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-210: The Variable Virtual Source-To-Axis Distance Effect On A Compact Proton Pencil Beam Scanning System

Purpose: We investigate the spot characteristic and dose profiles properties from a compact gantry proton therapy system. This compact design features a dedicated pencil beam scanning nozzle with the scanning magnet located upstream of the final 60 degree bending magnet. Due to the unique beam line design, uncertainty has been raised in the virtual source-to-axis distance (SAD). We investigate its potential clinical impact through measurements and simulation. Methods: A scintillator camera based detector was used to measure spot characteristics and position accuracy. An ion chamber array device was used to measure planar dose profile. Dose profile in-air simulation was performed using in-house built MATLAB program based on additional spot parameters directly from measurements. Spot characteristics such as position and in-air sigma values were used to general simulated 2D elliptical Gaussian spots. The virtual SAD distance changes in the longitudinal direction were also simulated. Planar dose profiles were generated by summation of simulated spots at the isocenter, 15 cm above the isocenter, and 15 cm below the isocenter for evaluation of potential clinical dosimetric impact. Results: We found that the virtual SAD varies depending on the spot location on the longitudinal axis. Measurements have shown that the variable SAD changes from 7 to 12 meters from one end to the other end of the treatment field in the longitudinal direction. The simulation shows that the planer dose profiles differences between the fixed SAD and variable SAD are within 3% from the isocenter profile and the lateral penumbras are within 1 mm difference. Conclusion: Our measurements and simulations show that there are minimum effects on the spot characteristics and dose profiles for this up-stream scanning compact system proton system. Further treatment planning study is needed with the variable virtual SAD accounted for in the planning system to show minimum dosimetric impact.

60 APPLIED LIFE SCIENCES↗

Scanning systems for particle cancer therapy

A particle beam to treat malignant tissue is delivered to a patient by a gantry. The gantry includes a plurality of small magnets sequentially arranged along a beam tube to transfer the particle beam with strong focusing and a small dispersion function, whereby a beam size is very small, allowing for the small magnet size. Magnets arranged along the beam tube uses combined function magnets where the magnetic field is a combination of a bending dipole field with a focusing or defocusing quadrupole field. A triplet set of combined function magnets defines the beam size at the patient. A scanning system of magnets arranged along the beam tube after the bending system delivers the particle beam in a direction normal to the patient, to minimize healthy skin and tissue exposure to the particle beam.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-F-16A-02: Simulation of a Medical Linear Accelerator for Teaching Purposes

Purpose: Detailed functioning of linear accelerator physics is well known. Less well developed is the basic understanding of how the adjustment of the linear accelerator's electrical components affects the resulting radiation beam. Other than the text by Karzmark, there is very little literature devoted to the practical understanding of linear accelerator functionality targeted at the radiotherapy clinic level. The purpose of this work is to describe a simulation environment for medical linear accelerators with the purpose of teaching linear accelerator physics. Methods: Varian type lineacs were simulated. Klystron saturation and peak output were modelled analytically. The energy gain of an electron beam was modelled using load line expressions. The bending magnet was assumed to be a perfect solenoid whose pass through energy varied linearly with solenoid current. The dose rate calculated at depth in water was assumed to be a simple function of the target's beam current. The flattening filter was modelled as an attenuator with conical shape, and the time-averaged dose rate at a depth in water was determined by calculating kerma. Results: Fifteen analytical models were combined into a single model called SIMAC. Performance was verified systematically by adjusting typical linac control parameters. Increasing klystron pulse voltage increased dose rate to a peak, which then decreased as the beam energy was further increased due to the fixed pass through energy of the bending magnet. Increasing accelerator beam current leads to a higher dose per pulse. However, the energy of the electron beam decreases due to beam loading and so the dose rate eventually maximizes and the decreases as beam current was further increased. Conclusion: SIMAC can realistically simulate the functionality of a linear accelerator. It is expected to have value as a teaching tool for both medical physicists and linear accelerator service personnel.

43 PARTICLE ACCELERATORS↗

Design and Testing of Subsystems for Mo-99 Production Facility

Three beamline configurations have been proposed for the SHINE Medical Technologies facility for producing fission-product 99 Mo using a D/T-accelerator (Figure 1). One configuration, proposed by Los Alamos National Laboratory (LANL), includes a three-bend magnet system with a total 20° bending angle. This configuration also includes a set of octuplet magnets to generate a non-Gaussian beam profile. Argonne has proposed two beamlines based on a (1) 10° bending magnet (Appendix A and Ref. 1) and (2) alpha magnets (Appendix B) that use a pair of raster doublets to redistribute the beam over the face of the target. This report gives an overview of the various designs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and Testing of Subsystems for Mo-99 Production Facility

So far, three beamline configurations have been proposed for the SHINE Medical Technologies facility for producing fission-product 99 Mousing a D/T-accelerator (Figure 1). One configuration, proposed by Los Alamos National Laboratory (LANL), includes a three-bend magnet system with a total 20 o bending angle. This configuration also includes a set of octuplet magnets to generate a non-Gaussian beam profile. Argonne has proposed two beamlines based on a (1)10° bending magnet (Appendix A and Ref. 1) and (2) alpha magnets (Appendix B) that use a pair of raster doublets to redistribute the beam over the face of the target. While those configurations are quite different, and each of the configurations has its advantages and disadvantages, they all have to incorporate the means to verify beam parameters before placing the beam on the target, monitor beam position and shape during a run, protect the target housing from the overheating due to beam displacement, and protect the beamlines from overheating due to beam misalignment.

07 ISOTOPE AND RADIATION SOURCES↗

Calculation of synchrotron radiation from high intensity electron beam at eRHIC

The Electron-Relativistic Heavy Ion Collider (eRHIC) at Brookhaven National Lab is an upgrade project for the existing RHIC. A 30 GeV energy recovery linac (ERL) will provide a high charge and high quality electron beam to collide with proton and ion beams. This will improve the luminosity by at least 2 orders of magnitude. The synchrotron radiation (SR) from the bending magnets and strong quadrupoles for such an intense beam could be penetrating the vacuum chamber and producing hazards to electronic devices and undesired background for detectors. In this paper, we calculate the SR spectral intensity, power density distributions and heat load on the chamber wall. We suggest the wall thickness required to stop the SR and estimate spectral characteristics of the residual and scattered background radiation outside the chamber.

43 PARTICLE ACCELERATORS↗

Commissioning the Super High Momentum Spectrometer in Hall C at Jefferson Lab

The Super High Momentum Spectrometer (SHMS) is a new spectrometer installed in Hall C at Jefferson Lab that can detect particles over a range of central momenta from 2-11 GeV/c and scattering angles from 5.5 to 40 degrees. Jefferson Lab delivers a high intensity electron beam with an energy up to 11 GeV to fixed targets in Hall C. The SHMS is a highly precise and essential upgrade for the 12 GeV Jefferson Lab physics program. Its beam line consists of a dipole magnet with a 3-degree horizontal bend, three quadrupole magnets for horizontal and vertical focusing of the beam, and the spectrometer dipole capable of a 4 T central magnetic field and 18.4-degree bend angle. Measurements in Hall C can be taken with the SHMS independently or in coincidence with the existing High Momentum Spectrometer (HMS). The SHMS was installed in the spring of 2017 and commissioned during the fall 2017/winter 2018 using a range of electron beam energies. This talk summarizes the initial results of the optics tuning of the SHMS and the performance during recent experimental running to include initial elastic hydrogen scattering measurements.

Szumila-Vance, Holly↗

The Negative Mass Instability in an Enge "Pretzel" Magnet

A novel magnet invented by Harald Enge has the useful property of achromatically deflecting charged particle beams. One can envision many applications for these for transport and guiding in high-current electron beam research. However, a high-current electron beam bent by the magnetic field in one of these magnets is subject to the negative mass instability. The negative mass instability is a problem for all accelerators that rely on magnetic fields to bend or circulate the beam. The subject of this article is the assessment of this instability in these devices for a range of electron beam parameters typical of the linear induction accelerators (LIAs) at Los Alamos. We first describe the properties of the magnet, and then calculate the negative mass instability growth rate for a high current beam having parameters of interest. Finally, we show that the beam does not spend enough time circulating through the magnet for the instability to grow significantly.

43 PARTICLE ACCELERATORS↗

SU-G-TeP1-10: Predicting Photon Percentage Depth Dose From Profile Due to Changes in Beam Quality

Purpose: To predict photon percentage depth dose (PDD) from profile due to a change in flattened (FF) and flattening-filter-free (FFF) beam quality. Methods: 6MV photon beam PDDs and profiles in a 3D water tank (3DW) and profiles in an ionization chamber array (ICP) were collected for different field sizes and depths with FF and FFF beams in a Versa HD (Elekta Ltd.). The energy was adjusted by changing the bending magnet current (BMC) ±15% from the clinical beam (6MV) in 5% increments. For baseline establishment, PDDs(depth≥3cm) were parameterized with bi-exponential functions and the PDD 20 to 10cm ratios (PDD{sub 20,10}) were calculated. Then, the FF profile at 10cm from the central axis (Pr{sub 10}) and the slope of the FFF central linear region (SFFF) were calculated. Calibration curves were established: (1) change in Pr{sub 10} and SFFF as functions of the change in PDD{sub 20,10} and (2) change in PDD(depth=3, 15 and 30cm) as function of the change in PDD{sub 20,10}. The differences between Pr{sub 10} and SFFF from baseline were calculated and, from calibration curves, changes in PDD{sub 20,10} and PDD(depth=3, 15 and 30cm) were obtained. Then, absolute PDD(depth=3, 15 and 30cm) values were input into a least-square-optimization algorithm to calculate the bi-exponential function’s optimal coefficients and generate the PDD(depths≥3cm). Results: The change in PDD{sub 20,10} relative to baseline increased (<±4%) with BMC. Pr{sub 10} increased (±6%) and SFFF decreased (±11%) with BMC. Relative differences between measured and calculated (i.e. PDD calculation from Pr{sub 10} and SFFF) PDDs were less than 1%. Results apply to FF and FFF beams measured in 3DW and ICP. Conclusion: Pr{sub 10} and SFFF are more sensitive than PDD to changes in beam energy and PDD information can be accurately generated from them. With known 3DW and ICP profile relationship, ICP can be used to obtain PDD for current photon beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

THE HIDDEN MAGNETIC FIELD OF THE YOUNG NEUTRON STAR IN KESTEVEN 79

Recent observations of the central compact object in the Kesteven 79 supernova remnant show that this neutron star (NS) has a weak dipole magnetic field (a few Multiplication-Sign 10{sup 10} G) but an anomalously large ({approx}64%) pulse fraction in its surface X-ray emission. We explore the idea that a substantial sub-surface magnetic field exists in the NS crust, which produces diffuse hot spots on the stellar surface due to anisotropic heat conduction, and gives rise to the observed X-ray pulsation. We develop a general-purpose method, termed 'Temperature Template with Full Transport' (TTFT), that computes the synthetic pulse profile of surface X-ray emission from NSs with arbitrary magnetic field and surface temperature distributions, taking into account magnetic atmosphere opacities, beam pattern, vacuum polarization, and gravitational light bending. We show that a crustal toroidal magnetic field of order a few Multiplication-Sign 10{sup 14} G or higher, varying smoothly across the crust, can produce sufficiently distinct surface hot spots to generate the observed pulse fraction in the Kes 79 NS. This result suggests that substantial sub-surface magnetic fields, much stronger than the 'visible' dipole fields, may be buried in the crusts of some young NSs, and such hidden magnetic fields can play an important role in their observational manifestations. The general TTFT tool we have developed can also be used for studying radiation from other magnetic NSs.

79 ASTRONOMY AND ASTROPHYSICS↗

Permanent Magnet Dipole-Quadrupole and Correcto-Tuner for Small Bore Accelerators

Electromagnets are used to bend electron beams and generate X-ray light. Permanent magnets have many advantages over electromagnets and are being studied as an alternative for small bore accelerators. This paper focuses on the mechanical design of two holders. First, a holder for the corrector and tuner permanent magnet assembly, which aims to correct the errors in the permanent magnetic field strength and orientation. Second, a holder for the dipole-quadrupole magnet assembly, which aims to provide the required magnetic strength to steer the electrons. Prototypes for the corrector, tuner and dipole-quadrupole holders were designed and tested to validate conceptual design. Results show that the corrector magnets can be oriented into a prescribed configuration, the tuner magnets can be oriented simultaneously regardless of the magnetic forces involved, and the dipole-quadrupole magnets can provide the magnetic strength required to steer electrons.

Huschke, Christopher↗

High field superconductor development and understanding

All present circular accelerators use superconducting magnets to bend and to focus the particle beams. The most powerful of these machines is the large hadron collider (LHC) at CERN. The main ring dipole magnets of the LHC are made from Nb-Ti but, as the machine is upgraded to higher luminosity, more powerful magnets made of Nb 3 Sn will be required. Our work addresses how to make the Nb 3 Sn conductors more effective and more suitable for use in the LHC. The most important property of the superconducting conductor used for an accelerator magnet is that it must have very high critical current density, the property that allows the generation of high magnetic fields in small spaces. Nb 3 Sn is the original high field superconductor, the material which was discovered in 1960 to allow a high current density in the field of about 9 T. For the high luminosity upgrade of the LHC, much higher current densities in fields of about 12 Tesla will be required. The critical value of the current density is of order 2600 A/mm 2 in a field of 12 Tesla. But there are very important secondary factors that complicate the attainment of this critical current density. The first is that the effective filament diameter must be no larger than about 40 µm. The second factor is that 50% of the cross-section of the Nb 3 Sn conductor that is pure copper must be protected from any poisoning by any Sn leakage through the diffusion barrier that protects the package of niobium and tin from which the Nb 3 Sn is formed by a high temperature reaction. These three, somewhat conflicting requirements, mean that optimization of the conductor is complex. The work described in this contract report addresses these conflicting requirements. They show that very sophisticated characterizations can uncover the way to satisfy all 3 requirements and they also suggest that the ultimate optimization of Nb 3 Sn is still not yet in sight

36 MATERIALS SCIENCE↗

1D Transient Study of Glidcop Surface Heating by Beam Power

Radiation fans from Insertion Devices and Bending Magnets are “trimmed” by various water-cooled absorbers located strategically downstream of those sources. Mostly, the absorber surfaces onto which power is deposited is constructed from Glidcop (rarely OFHC copper). A ring-resident Active Interlock (AI) system is designed to protect against overheating by disabling mis-steered beam within an allotted time. The Synchrotron Radiation Protection (SRP) protocol has the limiting criterion of 100*C maximum allowable temperature at any point when subject to mis-steered beam for a fixed period before the AI takes action. After 0.2 msec, radiation in excess of the +/- 500 um offset and +/- 250 urad angular error from the HEX SCW will trip in fault. AI specified beam parameters allow 1.0 msec to fully dump the electron beam. Given such short periods of peak power deposition we explore here these brief thermal transients to glean a general understanding of highest reachable limits before the onset of AI protection.

36 MATERIALS SCIENCE↗