Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKSCATTERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Dynamic coherent backscattering mirror

The phase of multiply scattered light has recently attracted considerable interest. Coherent backscattering is a striking phenomenon of multiple scattered light in which the coherence of light survives multiple scattering in a random medium and is observable in the direction space as an enhancement of the intensity of backscattered light within a cone around the retroreflection direction. Reciprocity also leads to enhancement of backscattering light in the spatial space. The random medium behaves as a reciprocity mirror which robustly converts a diverging incident beam into a converging backscattering one focusing at a conjugate spot in space. Here we first analyze theoretically this coherent backscattering mirror (CBM) phenomenon and then demonstrate the capability of CBM compensating and correcting both static and dynamic phase distortions occurring along the optical path. CBM may offer novel approaches for high speed dynamic phase corrections in optical systems and find applications in sensing and navigation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TH-E-BRE-09: TrueBeam Monte Carlo Absolute Dose Calculations Using Monitor Chamber Backscatter Simulations and Linac-Logged Target Current

Purpose: To simulate and measure radiation backscattered into the monitor chamber of a TrueBeam linac; establish a rigorous framework for absolute dose calculations for TrueBeam Monte Carlo (MC) simulations through a novel approach, taking into account the backscattered radiation and the actual machine output during beam delivery; improve agreement between measured and simulated relative output factors. Methods: The ‘monitor backscatter factor’ is an essential ingredient of a well-established MC absolute dose formalism (the MC equivalent of the TG-51 protocol). This quantity was determined for the 6 MV, 6X FFF, and 10X FFF beams by two independent Methods: (1) MC simulations in the monitor chamber of the TrueBeam linac; (2) linac-generated beam record data for target current, logged for each beam delivery. Upper head MC simulations used a freelyavailable manufacturer-provided interface to a cloud-based platform, allowing use of the same head model as that used to generate the publicly-available TrueBeam phase spaces, without revealing the upper head design. The MC absolute dose formalism was expanded to allow direct use of target current data. Results: The relation between backscatter, number of electrons incident on the target for one monitor unit, and MC absolute dose was analyzed for open fields, as well as a jaw-tracking VMAT plan. The agreement between the two methods was better than 0.15%. It was demonstrated that the agreement between measured and simulated relative output factors improves across all field sizes when backscatter is taken into account. Conclusion: For the first time, simulated monitor chamber dose and measured target current for an actual TrueBeam linac were incorporated in the MC absolute dose formalism. In conjunction with the use of MC inputs generated from post-delivery trajectory-log files, the present method allows accurate MC dose calculations, without resorting to any of the simplifying assumptions previously made in the TrueBeam MC literature. This work has been partially funded by Varian Medical Systems.

07 ISOTOPE AND RADIATION SOURCES↗

Backscatter dose effects for high atomic number materials being irradiated in the presence of a magnetic field: A Monte Carlo study for the MRI linac

Purpose: To quantify and explain the backscatter dose effects for clinically relevant high atomic number materials being irradiated in the presence of a 1.5 T transverse magnetic field. Methods: Interface effects were investigated using Monte Carlo simulation techniques. We used GPUMCD (v5.1) and GEANT4 (v10.1) for this purpose. GPUMCD is a commercial software written for the Elekta AB, MRI linac. Dose was scored using GPUMCD in cubic voxels of side 1 and 0.5 mm, in two different virtual phantoms of dimensions 20 × 20 × 20 cm and 5 × 5 × 13.3 cm, respectively. A photon beam was generated from a point 143.5 cm away from the isocenter with energy distribution sampled from a histogram representing the true Elekta, MRI linac photon spectrum. A slab of variable thickness and position containing either bone, aluminum, titanium, stainless steel, or one of the two different dental filling materials was inserted as an inhomogeneity in the 20 × 20 × 20 cm phantom. The 5 × 5 × 13.3 cm phantom was used as a clinical test case in order to explain the dose perturbation effects for a head and neck cancer patient. The back scatter dose factor (BSDF) was defined as the ratio of the doses at a given depth with and without the presence of the inhomogeneity. Backscattered electron fluence was calculated at the inhomogeneity interface using GEANT4. A 1.5 T magnetic field was applied perpendicular to the direction of the beam in both phantoms, identical to the geometry in the Elekta MRI linac. Results: With the application of a 1.5 T magnetic field, all the BSDF’s were reduced by 12%–47%, compared to the no magnetic field case. The corresponding backscattered electron fluence at the interface was also reduced by 45%–64%. The reduction in the BSDF at the interface, due to the application of the magnetic field, is manifested in a different manner for each material. In the case of bone, the dose drops at the interface contrary to the expected increase when no magnetic field is applied. In the case of aluminum, the dose at the interface is the same with and without the presence of the aluminum. For all of the other materials the dose increases at the interface. Conclusions: The reduction in dose at the interface, in the presence of the magnetic field, is directly related to the reduction in backscattered electron fluence. This reduction occurs due to two different reasons. First, the electron spectrum hitting the interface is changed when the magnetic field is turned on, which results in changes in the electron scattering probability. Second, some electrons that have curved trajectories due to the presence of the magnetic field are absorbed by the higher density side of the interface and no longer contribute to the backscattered electron fluence.

60 APPLIED LIFE SCIENCES↗

Laser transport and backscatter in low-density SiO 2 and Ta2O 5 foams

Experiments using a single 527 nm wavelength beam interacting with sub- and supercritical density SiO 2 and Ta 2 O 5 foams examined laser propagation and backscatter from laser–plasma instabilities such as Stimulated Brillouin Scattering (SBS). Two densities of each material were examined, and multiple diagnostics were used to characterize the propagation and backscatter. For 5 mg/cc SiO 2 (n e /n c = 0.375), the laser propagation distance was well approximated by treating the foam as a gas. However, for the 2 mg/cc SiO 2 foam (n e /n c = 0.15), the same model over-predicts the propagation distance by ~40%. Furthermore, existing analytical theories on propagation through subcritical foams were able to account for this difference. The laser heat wave propagated ~1/2 as far in Ta 2 O 5 than SiO 2 foams with similar electron density. We showed that this difference is due to the increased radiation losses in the higher Z foam. The fraction of backscattered light scales linearly with incident laser intensity for the range of intensities examined. Ta 2 O 5 foams had significantly lower levels of backscatter (1–3%) than the SiO 2 (4–8%), which is consistent with estimates of large Landau damping due to the presence of the oxygen atoms. The measured fraction of SBS backscattered laser energy for a 2 mg/cc SiO 2 foam shot was ~4 times lower than predicted by simulations assuming a gas-like foam. We found that we needed to assume increased ion heating such that T i /T e ~1.2–1.5 in the plasma to agree with the measured SBS reflectivity. Analytical models of laser-heated foams predict preferential heating of the ions as has been observed in previous experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Statistical properties of backscattered semiconductor laser radiation with different degrees of coherence

This paper compares the statistical properties of the backscatter intensity in a single-mode optical fibre for semiconductor lasers with a high and a low degree of coherence. We demonstrate that, when short probe pulses are used, shorter than the coherence times of the lasers, the statistical properties of the backscatter intensity obtained with the two lasers are identical, and the intensity distribution over an ensemble of independent fibre sections has an exponential form for both. With increasing probe pulse duration, the backscatter intensity distribution obtained with the shorter coherence time laser approaches a Gaussian one, whereas the distribution function obtained with the high-coherence laser remains nearly exponential. Reflectograms of a coherent reflectometer that relies on the detection of backscattered radiation have the highest contrast for an exponential backscatter intensity distribution over an ensemble of independent fibre sections. The reflectometer then probably has the highest sensitivity to external influences. This leads us to conclude that, when short probe pulses are used, which ensure high spatial resolution (10 m and better), one can use a laser with a short coherence time, equal to the pulse duration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TH-C-19A-09: Quantification of Transmission and Backscatter Factors as a function of Distance to Inhomogeneity Interface for Three Types of Surgical Implant Plates

Purpose: Carbon fiber materials have been increasingly used clinically, mainly in orthopedics, as an alternative to metallic implants because of their minimal artifacts on CT and MRI images. This study characterizes the transmission and backscatter property of carbon fiber plates (CarboFix Orthopedics, Herzeliya, Israel) with measurements for radiation therapy applications, and compares them to traditional Stainless Steel (SS) and Titanium (Ti) metal materials. Methods: For the transmission measurements, 1-mm-thick test plate was placed upstream from a plane parallel Markus chamber, separated by various thicknesses of polystyrene plates in 0.5 cm increments between 0 and 5 cm. With this setup, we quantified the radiation transmission as a function of distance to the inhomogeneity interface. The LINAC source to detector distance was maintained at 100 cm and 200 MU was delivered for each measurement. Two 3-cm solid water phantoms were placed at the top and bottom to provide build up. All the measurements were performed for 6 MV and 18 MV photons. The backscatter measurements had the identical setup, except that the test plate was downstream of the chamber from radiation. Results: The carbon fiber plates did not introduce any measureable inhomogeneity effect on the transmission and backscatter factor because of its low atomic number. In contrast, traditional metal implant materials caused up to 15% dose difference at upstream and 25% backscatter at downstream from radiation. Such differences decrease as the distance to the inhomogeneity interface increases and become unmeasurable at distance of 3 cm and 1 cm for upstream and downstream, respectively. Conclusion: A new type of carbon fiber implant plate was evaluated and found to have minimal inhomogeneity effect in MV radiation beams. Patients would benefit from a carbon based implant over metal for radiation therapy due to their minimal backscatter and imaging artifacts.

60 APPLIED LIFE SCIENCES↗

The aCORN backscatter-suppressed beta spectrometer

Backscatter of electrons from a beta detector, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electron–antineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter veto detectors surrounds a plastic scintillator beta energy detector. The spectrometer contains an axial magnetic field gradient, so electrons are efficiently admitted but have a low probability for escaping back through the entrance after backscattering. Lastly, the design, construction, calibration, and performance of the spectrometer are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling and Characterizing the electron backscatter in a cylindrical anode-based distributed X-ray source

Upcoming advancements in computed tomography architectures warrants the investigation of new X-ray source designs and the impacts that electron backscatter can have on these designs. One such design being investigated is a distributed, cylindrical anode-based X-ray source. For such a distributed X-ray source, we developed a modeling pipeline for simulating electron optics and transport to characterize the quality of the primary X-ray beam and the electron backscatter behavior. We report our results on the energy distributions of the bremsstrahlung spectra; electron backscatter ratio; and spatial, temporal, and energy distributions of backscattered electrons that return to the anode.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

A calculation of backscattering factor database for quantitative analysis by Auger electron spectroscopy

A systematic calculation of the backscattering factor in quantitative analysis by Auger electron spectroscopy has been performed for the primary electron beam of energy from the threshold energy of inner-shell ionization to 30 keV at the incident angle of 0 deg. - 89 deg. and for principal Auger transition and Auger electrons emitted from over 28 pure elements at an emission angle of 0 deg. - 89 deg. by using a Monte Carlo simulation method. The calculation employs a general definition of backscattering factor, Casnati's ionization cross section, up-to-date Monte Carlo model of electron scattering, and a large number of electron trajectories to ensure less statistical error. Both the configuration geometry of concentric hemispherical analyzer and the cylindrical mirror analyzer for Auger electron detection are considered in the calculation. The calculated backscattering factors are found to describe very well an experimental dependence of Auger electron intensity on primary energy and on incident angle for Si, Cu, Ag, and W in literature. The calculated numerical values of backscattering factor are stored in an open and online database at http://micro.ustc.edu.cn/BSFDataBase/BFAES.htm.

36 MATERIALS SCIENCE↗

Pulse Compression of Nd:YAG Laser with Stimulated Brillouin Scattering for Compton Backscattered X-ray Source

Compton backscattered x-ray source is developed in the energy region of a few hundred keV at Kansai Photon Science Institute of Japan Atomic Energy Agency (KPSI-JAEA). A remarkable feature of the Compton backscattered x-ray source is that the generated x-ray beam is a well-collimated and has a definite polarization property. The Compton backscattered x-ray source at KPSI-JAEA consists of the 150-MeV electron beam with the pulse duration of 24 ps accelerated by Microtron accelerator and a Nd:YAG laser with the pulse duration of 23 ns. At the first trial of the X-ray generation, the x-ray flux is not enough for actual use. As an actual x-ray source, it is important to increase the generated x-ray flux as much as possible. Thus, in order to increase the x-ray flux, we develop the pulse compression system for the Nd:YAG laser through the stimulated Brillouin scattering (SBS). The SBS pulse compression is characterized by its high conversion efficiency and by its simplicity of construction. On this article, we describe the present status of the SBS pulse compression for the Compton backscattered x-ray source at KPSI-JAEA.

07 ISOTOPE AND RADIATION SOURCES↗

Rutherford backscattering oscillation in scanning helium-ion microscopy

Scanning helium-ion microscopy (SHIM) yields high-resolution imaging and is capable of surface elemental analysis at the nanometer scale. Here we examine recently discovered SHIM backscattered intensity oscillations versus the target atomic number. These oscillations are contrary to the expected monotonic increase of the backscattered helium-ion (He{sup +}) rate with the atomic number of elemental samples. We explore the ion-sample interaction via numerical simulations for a variety of scattering geometries and confirm the presence of oscillations. The oscillations are attributed to the atomic rather than the nuclear structure of the target. To that end, we study the link (near anticorrelation) between backscatter rate and He{sup +} beam stopping power, both versus the target atomic number. This leads us to ascribe the origin of the backscatter oscillation to the ''Z{sub 2}-oscillations'' of the stopping power in ion-beam physics, with the latter being rooted in the valence electron configuration of elemental targets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Kinetic simulations of stimulated Raman backscattering and related processes for the shock-ignition approach to inertial confinement fusion

A detailed description of stimulated Raman backscattering and related processes for the purpose of inertial confinement fusion requires multi-dimensional kinetic simulations of a full speckle in a high-temperature, large-scale, inhomogeneous plasma. In particular for the shock-ignition scheme operating at high laser intensities, kinetic aspects are predominant. High- (I{lambda}{sub o}{sup 2}{approx}5x10{sup 15}W{mu}m{sup 2}/cm{sup 2}) as well as low-intensity (I{lambda}{sub o}{sup 2}{approx}10{sup 15}W{mu}m{sup 2}/cm{sup 2}) cases show the predominance of collisionless, collective processes for the interaction. While the two-plasmon decay instability and the cavitation scenario are hardly affected by intensity variation, inflationary Raman backscattering proves to be very sensitive. Brillouin backscattering evolves on longer time scales and dominates the reflectivities, although it is sensitive to the intensity. Filamentation and self-focusing do occur for all cases but on time scales too long to affect Raman backscattering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo study of electron-beam penetration and backscattering in multi-walled carbon nanotube materials: The effect of different scattering models

A systematic study of electron-beam penetration and backscattering in multi-walled carbon nanotube (MWCNT) materials for beam energies of {approx}0.3 to 30 keV is presented based on event-by-event Monte Carlo simulation of electron trajectories using state-of-the-art scattering cross sections. The importance of different analytic approximations for computing the elastic and inelastic electron-scattering cross sections for MWCNTs is emphasized. We offer a simple parameterization for the total and differential elastic-scattering Mott cross section, using appropriate modifications to the Browning formula and the Thomas-Fermi screening parameter. A discrete-energy-loss approach to inelastic scattering based on dielectric theory is adopted using different descriptions of the differential cross section. The sensitivity of electron penetration and backscattering parameters to the underlying scattering models is examined. Our simulations confirm the recent experimental backscattering data on MWCNT forests and, in particular, the steep increase of the backscattering yield at sub-keV energies as well as the sidewalls escape effect at high-beam energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Influence of lithium coating on the optics of Doppler backscatter system

This paper presents the first investigation of the effect of lithium coating on the optics of Doppler backscattering. A liquid lithium limiter has been applied in the Experimental Advanced Superconducting Tokamak (EAST), and a Doppler backscattering has been installed in the EAST. A parabolic mirror and a flat mirror located in the vacuum vessel are polluted by lithium. An identical optical system of the Doppler backscattering is set up in laboratory. The power distributions of the emission beam after the two mirrors with and without lithium coating (cleaned before and after), are measured at three different distances under four incident frequencies. The results demonstrate that the influence of the lithium coating on the power distributions are very slight, and the Doppler backscattering can work normally under the dosage of lithium during the 2014 EAST campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BASIS: A New Backscattering Spectrometer at the SNS

A new spectrometer named BASIS has recently entered the general user program at the Spallation Neutron Source. BASIS is an acronym for Backscattering Silicon Spectrometer. While there are several operational reactor-based spectrometers that utilize backscattering reflection from silicon single crystals, such as IN10 and IN16 [1] at the ILL, France; HFBS [2] at the NCNR, USA; and SPHERES [3] at the FRM-II, JCNS, Germany, BASIS is the first silicon backscattering spectrometer built on a spallation neutron source. Conceptually, it is similar to previously built time-of-flight backscattering spectrometers that utilize reflections from pyrolytic graphite or mica, such as IRIS [4] and OSIRIS [5] at the ISIS, UK; LAM-80 [6] at the KENS, Japan; or MARS [7] at the SINQ, Switzerland.

43 PARTICLE ACCELERATORS↗

The Backscattering Phase Function for a Sphere with a Two-Scale Relief of Rough Surface

The backscattering of light from spherical surfaces characterized by one and two-scale roughness reliefs has been investigated. The analysis is performed using the three-dimensional Monte-Carlo program POKS-RG (geometrical-optics approximation), which makes it possible to take into account the roughness of objects under study by introducing local geometries of different levels. The geometric module of the program is aimed at describing objects by equations of second-order surfaces. One-scale roughness is set as an ensemble of geometric figures (convex or concave halves of ellipsoids or cones). The two-scale roughness is modeled by convex halves of ellipsoids, with surface containing ellipsoidal pores. It is shown that a spherical surface with one-scale convex inhomogeneities has a flatter backscattering phase function than a surface with concave inhomogeneities (pores). For a sphere with two-scale roughness, the dependence of the backscattering intensity is found to be determined mostly by the lower-level inhomogeneities. The influence of roughness on the dependence of the backscattering from different spatial regions of spherical surface is analyzed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent backscattering of light in nematic liquid crystals

Multiple light scattering by director fluctuations in nematic liquid crystals is considered. A uniform director orientation is assumed to be specified by an applied magnetic field. The coherent backscattering effect, which consists in the presence of a sharp light backscattering peak, is studied. The Bethe-Salpeter equation is used to calculate the multiple scattering intensity taking into account the contributions of ladder and cyclic diagrams. An analytical expression for the angular and polarization dependences of the coherent backscattering intensity is obtained in terms of the diffusion approximation. The calculation and experimental results are compared. The developed theory is shown to qualitatively describe the elliptical shape of the backscattering cone, to explain the absence of a coherent contribution for crossed polarizations, and to calculate the relative peak height.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulation of coherent backscattering of light in nematic liquid crystals

Multiple scattering of light by the fluctuations of the director in a nematic liquid crystal (NLC) aligned by a magnetic field is considered. A peak of coherent backscattering is calculated by numerical simulation. Since the indicatrix of single scattering for a liquid crystal (LC) is known exactly, the calculations are carried out without any simplifying assumptions on the parameters of the liquid crystal. Multiple scattering is simulated as a random walk of photons in the medium. A peak of coherent backscattering in such a medium is very narrow; therefore, the so-called semianalytical method is applied. The parameters of the backscattering peak obtained by numerical simulation are compared with the available experimental data and with the results of analytical approximations. It turns out that the experimental data are in good agreement with the results of simulation. The results of numerical simulation adequately describe the anisotropy and the width of the backscattering peak.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗