Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Analytical Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Summary of Savannah River Site FY24 Salt Waste Qualification Data

Savannah River Mission Completion (SRMC), the Liquid Waste Operations subcontractor at SRS, and Savannah River National Laboratory (SRNL) analyzed samples from Savannah River Site (SRS) Waste Tanks 21H, 41H, and 42H to support qualification of Salt Waste Processing Facility (SWPF) Waste Batches 10, 11, 12, and 13 for processing (the FY24 Salt Batch Qualification samples). These Tanks (i.e. 21H, 41H and 42H) are blend tanks for feed to SWPF. This report focuses on the characterization of the Salt Batch Qualification sub-samples (i.e., any adjustments after qualification or as a part of processing are documented elsewhere). None of the samples displayed any unusual or unexpected characteristics such as large amounts of solids, floating solids, or unusual color. Characterization of these samples confirmed similar chemical composition and characteristics to previous salt waste batches. The analytical results (both rapid, typically 4 weeks, and long-term, typically 8 weeks) for Salt Batches 10, 11, 12, and 13 are now summarized and discussed in this technical report. SRMC-Analytical Laboratory (SRMC-AL), for the first time, provided all the short-term analyses data used in the qualification evaluations of SWPF Salt Batches 10, 11, 12, and 13. These SRMC short-term results are presented along with the results for the long-term analyses provided by SRNL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chemical Analysis Results for Potable Water from ISS Expeditions 21 Through 25

The Johnson Space Center Water and Food Analytical Laboratory (WAFAL) performed detailed ground-based analyses of archival water samples for verification of the chemical quality of the International Space Station (ISS) potable water supplies for Expeditions 21 through 25. Over a 14-month period the Space Shuttle visited the ISS on four occasions to complete construction and deliver supplies. The onboard supplies of potable water available for consumption by the Expeditions 21 to 25 crews consisted of Russian ground-supplied potable water, Russian potable water regenerated from humidity condensate, and US potable water recovered from urine distillate and condensate. Chemical archival water samples that were collected with U.S. hardware during Expeditions 21 to 25 were returned on Shuttle flights STS-129 (ULF3), STS-130 (20A), STS-131 (19A), and STS-132 (ULF4), as well as on Soyuz flights 19-23. This paper reports the analytical results for these returned potable water archival samples and their compliance with ISS water quality standards.

Straub, John E., II↗

Chemical Analysis Results for Potable Water from ISS Expeditions 21 to 25

The Johnson Space Center Water and Food Analytical Laboratory (WAFAL) performed detailed ground-based analyses of archival water samples for verification of the chemical quality of the International Space Station (ISS) potable water supplies for Expeditions 21 to 25. Over a 14-month period, the Space Shuttle visited the ISS on five occasions to complete construction and deliver supplies. The onboard supplies of potable water available for consumption by the Expeditions 21 to 25 crews consisted of Russian ground-supplied potable water, Russian potable water regenerated from humidity condensate, and US potable water recovered from urine distillate and condensate. Chemical archival water samples that were collected with U.S. hardware during Expeditions 21 to 25 were returned on Shuttle flights STS-129 (ULF3), STS-130 (20A), STS-131 (19A), STS-132 (ULF4) and STS-133 (ULF5), as well as on Soyuz flights 19-22. This paper reports the analytical results for the returned archival water samples and evaluates their compliance with ISS water quality standards. The WAFAL also received and analyzed aliquots of some Russian potable water samples collected in-flight and pre-flight samples of Rodnik potable water delivered to the Station on the Russian Progress vehicle during Expeditions 21 to 25. These additional analytical results are also reported and discussed in this paper.

Straub, John E., II↗

ISS Expeditions 16 & 17: Chemical Analysis Results for Potable Water

During the twelve month span of Expeditions 16 and 17 beginning October of 2007, the chemical quality of the potable water onboard the International Space Station (ISS) was verified safe for crew consumption through the return and chemical analysis of water samples by the Water and Food Analytical Laboratory (WAFAL) at Johnson Space Center (JSC). Reclaimed cabin humidity condensate and Russian ground-supplied water were the principle sources of potable water and for the first time, European groundsupplied water was also available. Although water was transferred from Shuttle to ISS during Expeditions 16 and 17, no Shuttle potable water was consumed during this timeframe. A total of 12 potable water samples were collected using U.S. hardware during Expeditions 16 and 17 and returned on Shuttle flights 1E (STS122), 1JA (STS123), and 1J (STS124). The average sample volume was sufficient for complete chemical characterization to be performed. The results of JSC chemical analyses of these potable water samples are presented in this paper. The WAFAL also received potable water samples for analysis from the Russian side collected inflight with Russian hardware, as well as preflight samples of Rodnik potable water delivered to ISS on Russian Progress vehicles 28 to 30. Analytical results for these additional potable water samples are also reported and discussed herein. Although the potable water supplies available during Expeditions 16 and 17 were judged safe for crew consumption, a recent trending of elevated silver levels in the SVOZV water is a concern for longterm consumption and efforts are being made to lower these levels.

Straub, John E., II↗

ISS Expeditions 16 through 20: Chemical Analysis Results for Potable Water

During the 2-year span from Expedition 16 through Expedition 20, the chemical quality of the potable water onboard the International Space Station (ISS) was verified safe for crew consumption through the return and chemical analysis of archival water samples by the Water and Food Analytical Laboratory (WAFAL) at Johnson Space Center (JSC). Reclaimed cabin humidity condensate and Russian ground-supplied water were the principal sources of potable water for Expeditions 16 through 18. During Expedition 18 the U.S. water processor assembly was delivered, installed, and tested during a 90-day checkout period. Beginning with Expedition 19, U.S. potable water recovered from a combined waste stream of humidity condensate and pretreated urine was also available for ISS crew use. A total of 74 potable water samples were collected using U.S. sampling hardware during Expeditions 16 through 20 and returned on both Shuttle and Soyuz vehicles. The results of JSC chemical analyses of these ISS potable water samples are presented in this paper. Eight potable water samples collected in flight with Russian hardware were also received for analysis, as well as 5 preflight samples of Rodnik potable water delivered to ISS on Russian Progress vehicles 28 to 34. Analytical results for these additional potable water samples are also reported and discussed.

Straub, John E., II↗

Tank Waste Characterization: History, Challenges, and Success Stories

The preparation and chemical and radiochemical analysis of Hanford tank waste samples can be performed with standard laboratory equipment and instruments as relatively routine processes that are not particularly challenging. Rather, the main challenges of tank waste characterization are associated with radiological dose and sampling limitations. Accurate, representative and effective sampling techniques are difficult with the waste tanks because they were not designed for routine sampling. There are a finite number of sampling locations for each tank based on riser positioning, depth and the operational functionality of the sampling riser. For example, in one recently emptied SST, there was one riser that was found to have had concrete dumped down it, thereby eliminating that sampling port. Additionally, the waste within the tank; especially true for the saltcake and sludge, is not homogenous. The ability to adequately mix a million-gallon double shell tank (DST) is a concern for data reproducibility. Another real challenge that must be addressed for sampling single shell tanks, is how to dissolve the salt cake waste in a compromised (leaking) SST. These physical constraints mean that uncertainty in the representativeness of samples must be considered when applying analytical results to the bulk contents of the tank. The tank waste is highly radioactive and thus can only be handled initially by facilities that can receive samples into concrete-shielded hot cells with remote operation with an example provided in Figure 1. The shielding protects the worker from the radiological dose while mineral oil windows and remotely operated manipulators enables the samples to be handled. At Hanford, analytical laboratories with these hot cell capabilities are limited to the Pacific Northwest National Laboratory and the main Hanford operations support laboratory, 222-S Laboratory. Because of their highly radioactive nature, samples must be sufficiently diluted to facilitate their analysis outside of a shielded cell. In some cases, this means some accuracy must be compromised to complete the analysis beyond that normally encountered for non-radioactive material.

Waste Characterization, BBI, PHOENIX: Tank Farms: ↗

Organic and Isotope Measurement Protocols under Development for the 2009 Mars Science Laboratory

The Mars Science Laboratory (MSL) is under development by NASA with several international partners for launch in 2009. MSL is designed to quantitatively explore a local region on Mars as a potential habitat for present or past life (http://mars.jpl.nasa.gov/msl). The goals of MSL are to (1) assess the past or present biological potential of the target environment, (2) to characterize its geology and geochemistry, (3) to study planetary processes that influence habitability, and (4) to characterize the surface radiation. The last substantial search for organic molecules on the surface of Mars was with the Viking Landers in 1976 [Biemann, et al., 19771. In that mission, no organics were detected in near surface fines and presently a more comprehensive search is required to understand the potential of that planet to support life. While the Mars Exploration Rovers are able to identify mineralogical signatures of aqueous alteration, they are not equipped to search for organics. The planned capabilities of the MSL rover payload will enable a search for a wide range of organic molecules in both solid samples of rocks and fines and atmospheric samples. MSL will also provide a determination of definitive mineralogy of the solid samples and precision isotope measurements of several volatile elements. Contact and remote surface and subsurface survey tools will establish context for Analytical Laboratory measurements and will facilitate sample selection. The Sample Analysis at Mars (SAM) suite of MSL addresses several of the mission's core measurement goals. SAM includes a gas chromatograph, a mass spectrometer, and a tunable laser spectrometer. We will describe the range of measurement protocols under development and test for SAM and the relationship of our planned measurements to outstanding issues of martian habitability.

Mahaffy, Paul R.↗

Evolution of Mass Spectrometers for High m / z Biological Ion Formation, Transmission, Analysis and Detection: A Personal Perspective

Mass spectrometry (MS) has become an essential tool in virtually all academic, pharmaceutical, and biopharmaceutical analytical laboratories. The specialized and bespoke area of MS research and application of high m / z ion (> m / z 6000 and high mass, >150 kDa) formation, transmission, analysis, and detection is a relatively new area of focus for MS that has seen dramatic acceleration in interest over the last two decades. Herein we delve into this exciting aspect of MS, discussing how MS instrumentation has been refined and evolved for native-MS analysis. We cover the early groundbreaking experiments showing high m / z ion formation, transmission, and preservation of protein structure in the gas phase. Additionally, we discuss specific instrument optimizations and modifications that have advanced high m / z ion generation, transmission, analysis, and detection, contributing to the research area known as gas-phase structural biology. Native-MS sample introduction methods, emerging technologies, and future perspectives are also examined. Finally, we share personal opinions, observations, and experiences that are new to the community or previously unpublished.

collisions↗

Calendar Year 2023 Underground Test Area Annual Sampling Letter Report Nevada National Security Site

The calendar year 2023 annual sampling letter report presents Plan implementation and a summary of field activities, sampling methods, well completion diagrams, and analytical laboratory results from sampling of wells associated with the Pahute Mesa CAUs. The CY 2023 letter report also presents data from samples collected from Well ER-EC-11_p3 as part of a sampling investigation. This well was resampled because of anomalously low standard tritium (3H) results from bailer sampling that occurred in July 2021.

54 ENVIRONMENTAL SCIENCES↗

A Robust Assessment of High-Precision Plutonium Isotopic Analysis by Thermal Ionization Mass Spectrometry [Slides]

TIMS at SRNL • SRNL consolidated analytical laboratories and services into one area – loss of TIMS capability during relocation. • SRNL installed a new Thermo Scientific TRITON Plus TIMS in our Category II Nuclear Facility to re-establish the lab’s TIMS capabilities in Feb. 2024. • Allows for handling, preparation, purification, and analysis of high-level radiological materials within a single location • Pu and U isotopic composition and assay measurement qualification have been priority since installation. • Once the instrument has been qualified, this capability will support internal and external customers.

07 ISOTOPE AND RADIATION SOURCES↗

Robust and High Throughput Tools for Characterization of Wet Cellulosic Biogas Feedstocks and Co-Products: Cooperative Research and Development Final Report, CRADA Number CRD-21-21472

This project will develop standardized analytical procedures to support understanding of the chemical composition of wet manure feedstocks, and the digestate formed following anaerobic digestion of organic waste to produce renewable natural gas (RNG). The developed methods will be validated to improve component mass closure, eliminate ambiguities around key constituents, and document the precision and accuracy of the methods. Following validation of the analytical laboratory methods for characterization of wet organic waste feedstocks and digestate, NLR will use the same samples to build and validate near-infrared (NIR) models for high throughput analysis, potentially deployable at commercial facilities, enabling increased production of low carbon intensity RNG from wet organic wastes.

09 BIOMASS FUELS↗

Space shuttle/food system study. Volume 2, Appendix G: Ground support system analysis. Appendix H: Galley functional details analysis

The capabilities for preflight feeding of flight personnel and the supply and control of the space shuttle flight food system were investigated to determine ground support requirements; and the functional details of an onboard food system galley are shown in photographic mockups. The elements which were identified as necessary to the efficient accomplishment of ground support functions include the following: (1) administration; (2) dietetics; (3) analytical laboratories; (4) flight food warehouse; (5) stowage module assembly area; (6) launch site module storage area; (7) alert crew restaurant and disperse crew galleys; (8) ground food warehouse; (9) manufacturing facilities; (10) transport; and (11) computer support. Each element is discussed according to the design criteria of minimum cost, maximum flexibility, reliability, and efficiency consistent with space shuttle requirements. The galley mockup overview illustrates the initial operation configuration, food stowage locations, meal assembly and serving trays, meal preparation configuration, serving, trash management, and the logistics of handling and cleanup equipment.

Source record↗

Accuracy of trace element determinations in alternate fuels

A review of the techniques used at Lewis Research Center (LeRC) in trace metals analysis is presented, including the results of Atomic Absorption Spectrometry and DC Arc Emission Spectrometry of blank levels and recovery experiments for several metals. The design of an Interlaboratory Study conducted by LeRC is presented. Several factors were investigated, including: laboratory, analytical technique, fuel type, concentration, and ashing additive. Conclusions drawn from the statistical analysis will help direct research efforts toward those areas most responsible for the poor interlaboratory analytical results.

Greenbauer-Seng, L. A.↗

Dynamic mechanical analysis and organization/storage of data for polymetric materials

Dynamic mechanical analysis was performed on a variety of temperature resistant polymers and composite resin matrices. Data on glass transition temperatures and degree of cure attained were derived. In addition a laboratory based computer system was installed and data base set up to allow entry of composite data. The laboratory CPU termed TYCHO is based on a DEC PDP 11/44 CPU with a Datatrieve relational data base. The function of TYCHO is integration of chemical laboratory analytical instrumentation and storage of chemical structures for modeling of new polymeric structures and compounds

Rosenberg, M.↗

Moisture loss from graphite structures for the Hubble Space Telescope

The construction and telescope assembly of the NASA's Hubble Space Telescope (HST) is described with particular reference to the features of its construction material. Due to the hygroscopic nature of the graphite-fiber reinforced epoxy, used for much of the structure of the HST, the telescope, when in orbit, suffers losses of water, absorbed during on-ground procedures, accompanied by shrinkage of the epoxy matrix, and needs periodic realignment. Using a combination of analytic, laboratory measured, and in-space measured data, an operational plan for adjusting the alignment of the HST is presented. The refocusing plan must take into account the preceding ground environment, as well as the prelaunch, lift-off, and predeployment environments of the HST-bearing Space Shuttle.

Facey, T. A.↗

Development of inspection techniques for quantitatively measuring surface contamination on SRM hardware

A contaminant is any material or substance which is potentially undesirable or which may adversely affect any part, component, or assembly. Contamination control of SRM hardware surfaces is a serious concern, for both Thiokol and NASA, with particular concern for contaminants which may adversely affect bonding surfaces. The purpose of this study is to develop laboratory analytical techniques which will make it possible to certify the cleanliness of any designated surface, with special focus on particulates (dust, dirt, lint, etc.), oils (hydrocarbons, silicones, plasticizers, etc.), and greases (HD-2, fluorocarbon grease, etc.). The hardware surfaces of concern will include D6AC steel, aluminum alloys, anodized aluminum alloys, glass/phenolic, carbon/phenolic, NBR/asbestos-silica, and EPDM rubber.

Law, R. D.↗

Chemical and microbiological experimentation for development of environmental control and life support systems

Microbiological techniques are under study with a view to the identification of viable microorganisms in liquid cultures, improve the identification of stressed organisms, and determine the biocidal activity of iodine and other chemicals on isolates from recycled water. A quality-assurance program has been implemented to validate data employed in making decisions concerning engineering and human health and safety. Analytical laboratory refinements will strongly aid the development of environmental control and life-support systems.

Whitman, G. A.↗

Some considerations on velocity vector accuracy in dust trajectory analysis

The relative contributions of comets and asteroids to the reservoir of dust in the interplanetary medium is not known. There are direct observations of dust released from comets and there is evidence to associate the IRAS dust bands with possible collisions of asteroids in the main belt. A means towards sorting out the parent sources has been proposed in the establishment of a dust collector in orbit about the Earth. The purpose of such a facility would be to collect not only cosmic dust particles intact but also the state vectors, as they arrive at the detector, the idea being that one may combine analytical laboratory analysis of the physics and chemistry of the captured particles with orbital data in order to help distinguish between bodies and identify parent bodies. The theoretical study of dust particle orbits in the solar system takes on greatly more importance if we use collected trajectory data. The orbital motion of dust when radiation and forces alone are acting is well understood. When gravitational forces due to the planets are included, the motion can become quite complex. In order to characterize the orbits of particles as they crossed the Earth's orbits, a study of the long-time dust orbital evolution was undertaken. We have considered various parameters associated with these dust orbits to see if one may in a general way discriminate between particles evolved from comets and asteroids. We proceed in this study as we have done previously. That is, we considered the dust particles as ideal black bodies, of density 1 gm/cc, spherical, with radii 10-100 microns. Particles of this size are affected by radiation forces, photon pressure, and Poynting-Robertson drag. Account was also taken of solar wind drag, which amounts to about 30 percent of the Poynting-Robertson drag negligible. The gravitational forces due to the planets are included, unlike in our previous study; the planetary orbits are those of true n-body interaction so that the possibility of secular resonance is included. Our method was to calculate explicitly by a numerical procedure the orbits of dust particles after they left their parent bodies. The motion is determined numerically with the implicit Runge-Kutta integrator using Gauss-Radau spacings.

Jackson, A. A.↗