Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Airways”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Venous return curves obtained from graded series of valsalva maneuvers

The effects were studied of a graded series of valsalva-like maneuvers on the venous return, which was measured transcutaneously in the jugular vein of an anesthetized dog, with the animal serving as its own control. At each of five different levels of central venous pressure, the airway pressure which just stopped venous return during each series of maneuvers was determined. It was found that this end-point airway pressure is not a good estimator of the animal's resting central venous pressure prior to the simulated valsalva maneuver. It was further found that the measured change in right atrial pressure during a valsalva maneuver is less than the change in airway pressure during the same maneuver, instead of being equal, as had been expected. Relative venous return curves were constructed from the data obtained during the graded series of valsalva maneuvers.

Mastenbrook, S. M., Jr.

Effect of lysophosphatidylcholine on the filtration coefficient in intact dog lungs

Lysophosphatidylcholine (lyso-Pc) is a lysophospholipid normally found in low concentrations in the lung. At high concentrations lyso-Pc, instilled into the airways, causes pulmonary edema. The hypothesis was tested that the edema caused by lyso-Pc was due to an increase in pulmonary microvascular membrane permeability. In 11 anesthetized dogs, the left lower lobes (LLL) were continuously weighed while lyso-Pc (20 mM) was instilled into the LLL airways. After 30 min, the microvascular membrane fluid filtration coefficient (Kf) was determined from the relationship between the rate of LLL weight gain and the pulmonary microvascular pressure. Kf was not significantly different between the lyso-Pc-treated lobes vs control lobes. The data do not support the hypothesis that lyso-Pc, instilled into the airways, causes an increase in pulmonary microvascular permeability.

Butler, B. D.

Paramyxovirus Infection Mimics In Vivo Cellular Dynamics in Three-Demensional Human Bronchio-Epithelial Tissue-Like Assemblies

Respiratory syncytial virus and parainfluenza virus cause severe respiratory disease, especially in infants, children and the elderly. An in vitro model that accurately mimics infection of the human respiratory epithelium (HRE) would facilitate vaccine development greatly. Monolayer cultures traditionally used to study these viruses do not accurately and precisely differentiate the replication efficiencies of wild type and attenuated viruses. Therefore, we engineered novel three-dimensional (3D) tissue-like assemblies (TLAs) of human broncho-epithelial (HBE) cells to produce a more physiologically relevant in vitro model of the HRE. TLAs resemble HRE structurally and by expression of differentiated epithelial cell markers. Most significantly, wild type viruses exhibited a clear growth advantage over attenuated strains in TLAs unlike monolayer cultures. In addition, the TLAs responded to virus infection by secreting pro-inflammatory mediators similar to the respiratory epithelia of infected children. These characteristics make the TLA model a valuable platform technology to develop and evaluate live, attenuated respiratory virus vaccine candidates for human use. Respiratory virus diseases, the most frequent and least preventable of all infectious diseases, range in severity from the common cold to severe bronchiolitis and pneumonia . Two paramyxoviruses, respiratory syncytial virus (RSV) and parainfluenza virus type 3 (PIV3), are responsible for a majority of the most severe respiratory diseases of infants and young children. RSV causes 70% of all bronchiolitis cases and is a major cause of morbidity and mortality worldwide, especially in infants. PIV3 causes 10-15% of bronchiolitis and pneumonia during infancy, second only to RSV, and 40% of croup in infants To date, licensed vaccines are not available to prevent these respiratory diseases. At present, traditional monkey kidney (Vero and LLC-MK2) and human (HEp-2) tissue culture cells and small animal models (mouse, cotton rat, guinea pig, ferret, and hamster) fail to accurately imitate viral replication and human disease states (8). Lacking an authentic model has impeded the development and evaluation of live, attenuated vaccine candidates. Development of a physiologically relevant in vitro tissue culture model that reproduces characteristics of the HRE, the primary target of RSV and PIV3, would aid in predicting clinical attenuation and safety of vaccine candidates. Successful tissue engineering of a 3D human intestinal model using novel NASA technology inspired the development of a tri-culture 3D model for the HRE. Sequential layering of primary mesenchymal cells (comprised of normal human fibroblasts and endothelial cells) followed by BEAS-2B epithelial cells derived from human bronchi and tracheae were recapitulated on Cultisphere and/or cytodex3 microcarriers in cylindrical vessels that rotate horizontally creating an organized epithelial structure. Horizontal rotation randomizes the gravity vector modeling aspects of microgravity. Mesenchymal and epithelial cells grown under these conditions reproduce the structural organization, multi-cellular complexity, and differentiation state of the HRE. The opportunity to study respiratory viruses in a nasal epithelium model is invaluable because the most promising respiratory virus vaccine candidates are live attenuated viruses for intranasal administration. Here we characterize the interactions of respiratory viruses and epithelial cells grown under modeled microgravity in comparison to gravity-ladened monolayers. 3D HBE TLAs and traditional monolayers (2D) are infected at 35 C, the upper temperature of the upper HRE, to simulate in vivo infection conditions. Growth kinetics of wild type (wt) RSV and PIV3 viruses were compared in 2D and 3D cells to that of strains attenuated in humans or rhesus macaques. This novel 3D HBE model also offers an opportunity to study whether the epithelial cell function, especially in host defenses recapitulated by mimicking the structural organization of the HRE. In vivo, airway epithelial cells play a significant and dynamic role in host defense by blocking paracellular permeability and modulating airway function through cellular interactions or tight junctions. As regulators of the innate immune response, epithelial cells constitutively express cytokines, chemokines, and colony stimulating factors including RANTES, IL-8, IL-6, GM-CSF, and G-CSF for proactive host defense. In response to viral infection, epithelial cells induce potent immuno-modulatory and pro-inflammatory cytokines that recruit phagocytic and inflammatory cells to clear the virus and enhance protection. Although disease pathogenesis is classically attributed to the cytopathic effects of the pathogen, severe disease states associated with RSV and PIV3 are attributed to the inflammatory response, especially in infants. RSV is a potent inducer of cytokines and pro-inflammatory mediators in epithelial cells in vivo. A differentiated human epithelial model independent of the complete functional immune system will help elucidate the role of epithelial cells in respiratory disease. We reported here, virus and host cell interactions in 3D HBE TLAs are similar to that in vivo. Because the epithelial cell organization of the TLAs impacts not only the expression of airway epithelial characteristics, but also cellular communication, the TLAs represent a more physiologically relevant model of the HRE than BEAS-2B or other non-tumour monolayer models of respiratory disease. As a result, wild type respiratory viruses have a clear growth advantage over attenuated viruses in TLAs unlike traditional monolayers. In addition, the TLAs respond to wild type virus infection by secreting pro-inflammatory mediators characteristic of infected HRE. TLAs expressing microbial defense mechanisms provide an excellent model to study the interactions of respiratory pathogens with their host and to identify the innate immunity mediators. Therefore, 3D HBE TLAs offer advantages for the study of respiratory viruses and the development of viral vaccine candidates.

Deatly, Anne M.

Subject-specific multi-scale modeling of the fate of inhaled aerosols

Determining the fate of inhaled aerosols in the respiratory system is essential in assessing the potential toxicity of inhaled airborne materials, responses to airborne pathogens, or in improving inhaled drug delivery. The availability of high-resolution clinical lung imaging and advances in the reconstruction of lung airways from CT images have led to the development of subject-specific in-silico 3D models of aerosol dosimetry, often referred to as computational fluid-particle-dynamics (CFPD) models. As CFPD models require extensive computing resources, they are typically confined to the upper and large airways. These models can be combined with lower-dimensional models to form multiscale models that predict the transport and deposition of inhaled aerosols in the entire respiratory tract. Understanding where aerosols deposit is only the first of potentially several key events necessary to predict an outcome, being a detrimental health effect or a therapeutic response. To that end, multiscale approaches that combine CFPD with physiologically-based pharmacokinetics (PBPK) models have been developed to evaluate the absorption, distribution, metabolism, and excretion (ADME) of toxic or medicinal chemicals in one or more compartments of the human body. CFPD models can also be combined with host cell dynamics (HCD) models to assess regional immune system responses. Here, this paper reviews the state of the art of these different multiscale approaches and discusses the potential role of personalized or subject-specific modeling in respiratory health.

60 APPLIED LIFE SCIENCES

NASA Global Atmospheric Sampling Program (GASP) data report for tape VL0006

The NASA Global Atmospheric Sampling Program (GASP) is obtaining measurements of atmospheric trace constituents in the upper troposphere and lower stratosphere using fully automated air sampling systems on board several commercial B-747 aircraft in routine airline service. Atmospheric ozone, and related flight and meteorological data were obtained during 245 flights of a Qantas Airways of Australia B-747 and two Pan American World Airways B-747s from July 1976 through September 1976. In addition, whole air samples, obtained during three flights, were analyzed for trichlorofluoromethane, and filter samples, obtained during four flights, were analyzed for sulfates, nitrates, fluorides, and chlorides. Flight routes and dates, instrumentation, data processing procedures, data tape specifications, and selected analyses are discussed.

Gauntner, D. J.

Flight service evaluation of two aluminum-brazed titanium spoilers

The long-term service evaluation of two aluminum-brazed titanium (ABTi) honeycomb flight spoilers was concluded. The two spoilers had about 7.5 years of commercial flight experience on All Nippon Airways Model 737 aircraft. All Nippon Airways was selected because Japan has one of the most severe marine-industrial environments in the world. The results indicated that both flight spoilers still had the same load-carrying capability as when they were originally installed. No direct evidence of any corrosion was observed on either spoiler. Another significant accomplishment of this effort was the development of a braze design for efficiently distributing point loads from the fittings and skin into the honeycomb core.

Boyer, R. R.

Pulmonary function in men after oxygen breathing at 3.0 ATA for 3.5 h

A complete description of pulmonary measurements obtained after continuous O2 exposure of 13 healthy men at 3.0 ATA for 3.5 h is presented. Measurements included flow-volume loops, spirometry, and airway resistance(n = 12); CO diffusing capacity (n = 11); closing volumes (n= 6); and air vs. HeO2 forced vital capacity maneuvers (n = 5). The average difference in maximum mid expiratory flows at 50 percent vital capacity on air and HeO2 was found to be significantly reduced postexposure by 18 percent. Raw and CO diffusing capacity were not changed postexposure. It is concluded that the relatively large change in forced expiratory flow at 25-75 percent of vital capacity compared with the mean forced expiratory volume in 1 s, the reduction in density dependence of flow, and the normal Raw postexposure are all consistent with flow limitation in peripheral airways as a major cause of the observed reduction in expiratory flow.

Clark, J. M.

Ventilation-perfusion relationships in the lung during head-out water immersion

Mechanisms of altered pulmonary gas exchange during water immersion were studied in 12 normal males: 6 young (aged 20-29) and 6 older (aged 40-45). It is concluded that, in young subjects with closing volume (CV) less than expiratory reserve volume (ERV), gas exchange was enhanced during immersion, because normal ventilation-perfusion relations were preserved, and by mass balance, the ventilation/O2 uptake changes elevated arterial P(O2). In older males with CV greater than ERV and 52 percent of tidal volume below CV, immersion-induced airways closure during tidal breathing was associated with minimally increased shunt that did not significantly impair gas exchange. It is suggested that airways closure of this degree is of little importance to gas exchange.

Derion, Toniann

Advanced Cardiac Life Support (ACLS) utilizing Man-Tended Capability (MTC) hardware onboard Space Station Freedom

Because of the time and distance involved in returning a patient from space to a definitive medical care facility, the capability for Advanced Cardiac Life Support (ACLS) exists onboard Space Station Freedom. Methods: In order to evaluate the effectiveness of terrestrial ACLS protocols in microgravity, a medical team conducted simulations during parabolic flights onboard the KC-135 aircraft. The hardware planned for use during the MTC phase of the space station was utilized to increase the fidelity of the scenario and to evaluate the prototype equipment. Based on initial KC-135 testing of CPR and ACLS, changes were made to the ventricular fibrillation algorithm in order to accommodate the space environment. Other constraints to delivery of ACLS onboard the space station include crew size, minimum training, crew deconditioning, and limited supplies and equipment. Results: The delivery of ACLS in microgravity is hindered by the environment, but should be adequate. Factors specific to microgravity were identified for inclusion in the protocol including immediate restraint of the patient and early intubation to insure airway. External cardiac compressions of adequate force and frequency were administered using various methods. The more significant limiting factors appear to be crew training, crew size, and limited supplies. Conclusions: Although ACLS is possible in the microgravity environment, future evaluations are necessary to further refine the protocols. Proper patient and medical officer restraint is crucial prior to advanced procedures. Also emphasis should be placed on early intubation for airway management and drug administration. Preliminary results and further testing will be utilized in the design of medical hardware, determination of crew training, and medical operations for space station and beyond.

Smith, M.

The high speed civil transport: A technology challenge

It has been over 17 years since Concorde entered service with British Airways and Air France. The thirteen production aircraft are still safely operating and may extend their service life into the next century. We can appreciate the technical success Concorde has achieved. However, from the onset the aircraft was unable to achieve overall economic viability. Currently the aircraft does generate a yearly profit for British Airways which is privatized. Unacceptable airport noise and sonic boom overland levels were detrimental to the aircraft performing between many worldwide city pairs. On the horizon appears a possible successor to Concorde that will need to demonstrate environmental acceptability and economic viability shortly after the turn of the century. This vehicle has been labelled the High Speed Civil Transport (HSCT). I believe that we can overcome the environmental and economic goals based on encouraging market demand forecasts and technology improvements that are materializing in current research and development programs.

Mortlock, Alan K.

Gas Sensor

High Technology Sensors, Inc.'s Model SS-250 carbon dioxide detector uses a patented semiconductor optical source that efficiently creates infrared radiation, which is focused through an airway on a detector. Carbon dioxide passing through the airway absorbs the radiation causing the detector to generate a signal. The small size and low power requirements of the SS-250 make it attractive for incorporation in a variety of medical instruments.

Source record

Effects of immersion in cool water on lung-exhaled nitric oxide at rest and during exercise

Lung nitric oxide (NO) has been postulated to relax airway and vascular smooth muscle at rest and during exercise. As a cold environment is a common cause of respiratory distress, lung exhaled NO was measured during skin and core body cooling at rest and during a progressive cycle exercise. Ten healthy male subjects were immersed in water at a water temperature (Tw) which was thermal neutral (35 degrees C) at 30 degrees C Tw, at which only skin temperature is decreased; and at 20 degrees C Tw, at which the core temperature is decreased (0.05 degrees C). At rest, V(O), and V(E) increased while exhaled NO concentration [NO] and the rate of expiration of NO (V(NO)) decreased with decreased Tw. V(O2) and ventilation (V(E)) increased with workload (W) and the values at all Tw were not different, whereas, [NO] decreased with W and the values during exercise were progressively less at all Ws as Tw declined. These results indicate that lung NO output is reduced in a graded fashion during body cooling at rest and during exercise. This suggests that lower lung NO may contribute to airway obstruction in cold environments and NO may contribute to regulation of lung heat and water exchange.

Non-NASA Center

Cardiogenic oscillation phase relationships during single-breath tests performed in microgravity

We studied the phase relationships of the cardiogenic oscillations in the phase III portion of single-breath washouts (SBW) in normal gravity (1 G) and in sustained microgravity (microG). The SBW consisted of a vital capacity inspiration of 5% He-1.25% sulfurhexafluoride-balance O2, preceded at residual volume by a 150-ml Ar bolus. Pairs of gas signals, all of which still showed cardiogenic oscillations, were cross-correlated, and their phase difference was expressed as an angle. Phase relationships between inspired gases (e.g., He) and resident gas (n2) showed no change from 1 G (211 +/- 9 degrees) to microG (163 +/- 7 degrees). Ar bolus and He were unaltered between 1 G (173 +/- 15 degrees) and microG (211 +/- 25 degrees), showing that airway closure in microG remains in regions of high specific ventilation and suggesting that airway closure results from lung regions reaching low regional volume near residual volume. In contrast, CO2 reversed phase with He between 1 G (332 +/- 6 degrees) and microG (263 +/- 27 degrees), strongly suggesting that, in microG, areas of high ventilation are associated with high ventilation-perfusion ratio (VA/Q). This widening of the range of VA/Q in microG may explain previous measurements (G.K. Prisk, A.R. Elliott, H.J.B. Guy, J.M. Kosonen, and J.B. West J. Appl. Physiol. 79: 1290-1298, 1995) of an overall unaltered range of VA/Q in microG, despite more homogeneous distributions of both ventilation and perfusion.

Non-NASA Center

Pulmonary function in space

The lung is exquisitely sensitive to gravity, and so it is of interest to know how its function is altered in the weightlessness of space. Studies on National Aeronautics and Space Administration (NASA) Spacelabs during the last 4 years have provided the first comprehensive data on the extensive changes in pulmonary function that occur in sustained microgravity. Measurements of pulmonary function were made on astronauts during space shuttle flights lasting 9 and 14 days and were compared with extensive ground-based measurements before and after the flights. Compared with preflight measurements, cardiac output increased by 18% during space flight, and stroke volume increased by 46%. Paradoxically, the increase in stroke volume occurred in the face of reductions in central venous pressure and circulating blood volume. Diffusing capacity increased by 28%, and the increase in the diffusing capacity of the alveolar membrane was unexpectedly large based on findings in normal gravity. The change in the alveolar membrane may reflect the effects of uniform filling of the pulmonary capillary bed. Distributions of blood flow and ventilation throughout the lung were more uniform in space, but some unevenness remained, indicating the importance of nongravitational factors. A surprising finding was that airway closing volume was approximately the same in microgravity and in normal gravity, emphasizing the importance of mechanical properties of the airways in determining whether they close. Residual volume was unexpectedly reduced by 18% in microgravity, possibly because of uniform alveolar expansion. The findings indicate that pulmonary function is greatly altered in microgravity, but none of the changes observed so far will apparently limit long-term space flight. In addition, the data help to clarify how gravity affects pulmonary function in the normal gravity environment on Earth.

short duration

Ventilation-perfusion matching during exercise

In normal subjects, exercise widens the alveolar-arterial PO2 difference (P[A-a]O2) despite a more uniform topographic distribution of ventilation-perfusion (VA/Q) ratios. While part of the increase in P(A-a)O2 (especially during heavy exercise) is due to diffusion limitation, a considerable amount is caused by an increase in VA/Q mismatch as detected by the multiple inert gas elimination technique. Why this occurs is unknown, but circumstantial evidence suggests it may be related to interstitial pulmonary edema rather than to factors dependent on ventilation, airway gas mixing, airway muscle tone, or pulmonary vascular tone. In patients with lung disease, the gas exchange consequences of exercise are variable. Thus, arterial PO2 may increase, remain the same, or fall. In general, patients with advanced chronic obstructive pulmonary disease (COPD) or interstitial fibrosis who exercise show a fall in PO2. This is usually not due to worsening VA/Q relationships but mostly to the well-known fall in mixed venous PO2, which itself results from a relatively smaller increase in cardiac output than VO2. However, in interstitial fibrosis (but not COPD), there is good evidence that a part of the fall in PO2 on exercise is caused by alveolar-capillary diffusion limitation of O2 transport; in COPD (but not interstitial fibrosis), a frequent additional contributing factor to the hypoxemia of exercise is an inadequate ventilatory response, such that minute ventilation does not rise as much as does CO2 production or O2 uptake, causing arterial PCO2 to increase and PO2 to fall.

Non-NASA Center

Projecting Future Scheduled Airline Demand, Schedules and NGATS Benefits Using TSAM

The Transportation Systems Analysis Model (TSAM) developed by Virginia Tech s Air Transportation Systems Lab and NASA Langley can provide detailed analysis of the effects on the demand for air travel of a full range of NASA and FAA aviation projects. TSAM has been used to project the passenger demand for very light jet (VLJ) air taxi service, scheduled airline demand growth and future schedules, Next Generation Air Transportation System (NGATS) benefits, and future passenger revenues for the Airport and Airway Trust Fund. TSAM can project the resulting demand when new vehicles and/or technology is inserted into the long distance (100 or more miles one-way) transportation system, as well as, changes in demand as a result of fare yield increases or decreases, airport transit times, scheduled flight times, ticket taxes, reductions or increases in flight delays, and so on. TSAM models all long distance travel in the contiguous U.S. and determines the mode choice of the traveler based on detailed trip costs, travel time, schedule frequency, purpose of the trip (business or non-business), and household income level of the traveler. Demand is modeled at the county level, with an airport choice module providing up to three airports as part of the mode choice. Future enplanements at airports can be projected for different scenarios. A Fratar algorithm and a schedule generator are applied to generate future flight schedules. This paper presents the application of TSAM to modeling future scheduled air passenger demand and resulting airline schedules, the impact of NGATS goals and objectives on passenger demand, along with projections for passenger fee receipts for several scenarios for the FAA Airport and Airway Trust Fund.

Dollyhigh, Samuel

Subject-specific modeling framework for particle deposition using computational fluid dynamics

Quantifying particle deposition and dose in the respiratory tract requires a physiologically realistic representation and reproducible computational workflows. However, existing modeling frameworks, such as the International Commission on Radiological Protection (ICRP) compartmental models and the Multiple Path Particle Dosimetry (MPPD) tool, lack detailed deposition profiles and subject-specific capabilities. The combination of advances in computer vision algorithms applied to the respiratory tract and Computational Fluid and Particle Dynamics (CFPD) allows high-fidelity simulations of particle behavior in anatomically accurate geometries derived from individual CT scans. The segmentation, preprocessing, and file preparation task for a CFPD simulation was often time-consuming, and no prior studies to-date have yet presented a fully automated framework. This work presents a fully automated workflow to obtain individualized particle deposition profiles in the human respiratory tract. The pipeline starts with segmenting upper and lower airway geometries using morphological and deep learning-based methods, generating three-dimensional (3D) models from CT imaging data. Next, a series of algorithms are presented to quality check and prepare the 3D geometry for a CFD or CFPD simulation. The preprocessing step includes correcting geometric artifacts, enforcing a physically consistent mesh, and automatically identifying and capping multiple outlets, which is required for CFD/CFPD simulations. These processed models are then input into open-source (OpenFOAM) or commercial (StarCCM+) CFD solvers, where flow and transient particle transport equations — including turbulence and particle–wall interactions are solved under realistic breathing conditions. Finally, the resulting particle deposition profiles can be integrated with Monte Carlo radiation transport codes and state-of-the-art computational phantoms to assess organ-specific absorbed doses in scenarios of radioactive aerosol inhalation. The presented work streamlines respiratory tract segmentation, preprocessing for CFD/CFPD simulations, and integration with dose assessment workflows, reducing manual intervention and improving access to high-fidelity, subject-specific modeling. The high precision in predicted particle deposition and dose distributions can improve personalized treatment strategies in respiratory medicine and refine dose estimates for radiation protection.

AI

Modeling aerosol bolus inhalations in the human lung with the multiple path particle deposition model: Comparison with experimental data

Existing one-dimensional (1D) models of aerosol dosimetry often ignore mixing mechanisms of inhaled aerosols during their transport in the lung. This mixing or aerosol dispersion results from different physical mechanisms in different regions of the lung. It is a higher order effect, which cannot be directly captured in 1D modeling approaches, and thus is sometimes modeled as a diffusive process. Here, in this study, we improved our recently developed alveolar mixing module incorporated in the multiple path particle dosimetry model (MPPD) to account for flow irreversibility and particle trapping in the alveolar spaces, as well as mixing occurring in the tracheobronchial region. This new version of MPPD was coupled with CFPD-based predictions of aerosol bolus dispersion in the oral airway. The model was used to predict the deposition, dispersion, and mode shift of aerosol bolus inhaled at different penetration depths within the lung for breathing patterns and particle size matching those used in a previous experimental study (Darquenne et al., 2016). Even though a quite simplified approach was used, the computations appear to describe subject-specific and test-specific experimental data reasonably well. The proposed combined dispersion-deposition model can be a useful tool for targeted drug delivery and also for exposure health risk assessment.

MPPD