Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Adaptive radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Adaptive materials and systems for manipulation of electromagnetic radiation

Fully artificial, adaptive composite materials and systems, having variable transmittance, reflectance, and/or absorptance to radiation in visible, infrared, or other desired region of the electromagnetic spectrum, and methods of the manufacture and use thereof are provided. The adaptive composite materials and systems possess an unprecedented combination of properties and are, therefore, poised to enable a broad range of practical applications. The adaptive composite material incorporates at least one size-variable active area having a variable transmittance, reflectance, and/or absorptance in at least a portion of the electromagnetic spectrum and comprises at least: an elastomer substrate, a texturizing layer disposed on top of the substrate, and an optional reflective coating disposed on top of the texturizing layer. In operation, the stretching and relaxation of the elastomer substrate causes changes in the surface morphology of the texturized layers (e.g., the change in the size and depth of surface features in the texturizing layer), this in turn results in the increased or decreased transmittivity, reflectivity, and/or absorptivity of the active area.

Gorodetsky, Alon A.↗

Initial Feasibility and Clinical Implementation of Daily MR-Guided Adaptive Head and Neck Cancer Radiation Therapy on a 1.5T MR-Linac System: Prospective R-IDEAL 2a/2b Systematic Clinical Evaluation of Technical Innovation

This prospective study is, to our knowledge, the first report of daily adaptive radiation therapy (ART) for head and neck cancer (HNC) using a 1.5T magnetic resonance imaging-linear accelerator (MR-linac) with particular focus on safety and feasibility and dosimetric results of an online rigid registration-based adapt to position (ATP) workflow.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Space simulator Patent

Space simulator with uniform test region radiation distribution, adapted to simulate Venus solar radiations

Thiele, C.↗

Moment-based adaptive time integration for thermal radiation transport

Here, in this paper we develop a framework for moment-based adaptive time integration of deterministic multifrequency thermal radiation transpot (TRT). We generalize our recent semi-implicit-explicit (IMEX) integration framework for gray TRT to multifrequency TRT, and also introduce a semi-implicit variation that facilitates higher-order integration of TRT, where each stage is implicit in all components except opacities. To appeal to the broad literature on adaptivity with Runge–Kutta methods, we derive new embedded methods for four asymptotic preserving IMEX Runge–Kutta schemes we have found to be robust in our previous work on TRT and radiation hydrodynamics. We then use a moment-based high-order-low-order representation of the transport equations. Due to the high dimensionality, memory is always a concern in simulating TRT. We form error estimates and adaptivity in time purely based on temperature and radiation energy, for a trivial overhead in computational cost and memory usage compared with the base second order integrators. We then test the adaptivity in time on the tophat and Larsen problem, demonstrating the ability of the adaptive algorithm to naturally vary the timestep across 4–5 orders of magnitude, ranging from the dynamical timescales of the streaming regime to the thick diffusion limit.

97 MATHEMATICS AND COMPUTING↗

Protective mechanisms and acclimation to solar ultraviolet-B radiation in Oenothera stricta

Plant adaptations ameliorating or repairing the damaging effects of ultraviolet-B (UV-B) radiation on plant tissue were investigated. The degree of phenotype plasticity in UV protective mechanisms and acclimation in relation to the natural solar UV-B radiation flux and in an enhanced UV-B irradiance environment was also examined. Mechanisms by which plants avoid radiation, adaptations altering the path of radiation incident on the leaf, and repair processes were considered. Attenuation of UV-B by tissues, UV-B irradiation into the leaf, and the effects of UV-B on photosynthesis were investigated.

Robberecht, R.↗

Liquid sheet radiator apparatus

An external flow, liquid sheet radiator apparatus adapted for space applications has as its radiating surface a thin stable liquid sheet formed by fluid flow through a very narrow slit affixed to the sheet generator. As a result of surface tension forces, the sheet has a triangular shape and is collected into a simply designed collector positioned at the apex of the triangle. The specific power for the liquid sheet is virtually the same as the droplet sheet specific power.

Chubb, Donald L.↗

Radiation-induced bystander effect and adaptive response in mammalian cells

Two conflicting phenomena, bystander effect and adaptive response, are important in determining the biological responses at low doses of radiation and have the potential to impact the shape of the dose-response relationship. Using the Columbia University charged-particle microbeam and the highly sensitive AL cell mutagenic assay, we show here that non-irradiated cells acquire mutagenesis through direct contact with cells whose nuclei have been traversed with a single alpha particle each. Pretreatment of cells with a low dose of X-rays four hours before alpha particle irradiation significantly decreased this bystander mutagenic response. Results from the present study address some of the fundamental issues regarding both the actual target and radiation dose effect and can contribute to our current understanding in radiation risk assessment. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

NASA Discipline Radiation Health↗

A Block-Structured Adaptive Mesh Framework to Solve Radiation Transfer Equation in Irregular Embedded Geometries

Radiation transport arises in various scientific, industrial, and medical fields, and understanding its effect in applications is needed to make accurate predictions, safety assessments and performance optimizations. Solving the Radiation Transport Equation (RTE) is challenging due to its integro-differential nature, which involves both differential and integral terms. The differential term describes the change in radiation intensity due to absorption and emission, while the integral term accounts for scattering. The accurate modeling of radiation is further complicated in many applications due to the complex, irregular geometries. Various methods exist for solving the RTE, including the zonal, Monte Carlo, spherical harmonics, discrete ordinates, and finite volume methods. Traditional mesh-based approaches, which rely on structured or unstructured meshes, struggle with irregular geometries due to: a) the difficulty of conforming structured grids to irregular domains, b) challenges in enforcing boundary conditions correctly, and c) the additional computational cost of unstructured mesh methods. This work presents a second-order accurate method for solving the RTE in irregular geometries. The radiation intensity is discretized using the finite-volume method in both spatial and angular directions on regular Cartesian grid blocks. Leveraging the block-structured adaptive mesh refinement (AMR) framework provided by AMReX, our method refines the grid locally to reduce spatial discretization error, ensuring a converged numerical solution while minimizing computational costs elsewhere. A two-stage deferred correction approach is employed: First, a first-order discretization on grid blocks is solved using an algebraic multigrid method in HYPRE. Second, a correction term is applied explicitly to achieve second-order accuracy. The correction term is calculated by approximating the radiation flux on cell faces using a Total Variation Diminishing (TVD) scheme. This approach ensures quick convergence of the multigrid method while preserving higher-order accuracy of the numerical solution. Irregular geometries are resolved as embedded boundaries (EB), resulting in both cut cells and regular cells. In cut cells, we modify the fluxes using face fractions and incorporate additional contributions from EB boundary conditions. To ensure higher-order convergence near the EB interface, the correction term is modified by interpolating the radiation intensity to fictitious ghost points. The implementation takes advantage of modern supercomputers by leveraging AMReX’sMPI/X parallelization strategy where X can be MPI or a GPU accelerator including CUDA, HIP and DPC++. We validate our solver using classical test cases, both with and without EB, demonstrating accuracy and efficiency. Additionally, we analyze the impact of adaptive mesh refinement on solution accuracy and computational cost, highlighting the advantages of our approach for high-resolution radiation transport simulations.

computational fluid dynamics (CFD)↗

Effects of heavy ions on visual function and electrophysiology of rodents: the ALTEA-MICE project

ALTEA-MICE will supplement the ALTEA project on astronauts and provide information on the functional visual impairment possibly induced by heavy ions during prolonged operations in microgravity. Goals of ALTEA-MICE are: (1) to investigate the effects of heavy ions on the visual system of normal and mutant mice with retinal defects; (2) to define reliable experimental conditions for space research; and (3) to develop animal models to study the physiological consequences of space travels on humans. Remotely controlled mouse setup, applied electrophysiological recording methods, remote particle monitoring, and experimental procedures were developed and tested. The project has proved feasible under laboratory-controlled conditions comparable in important aspects to those of astronauts' exposure to particle in space. Experiments are performed at the Brookhaven National Laboratories [BNL] (Upton, NY, USA) and the Gesellschaft fur Schwerionenforschung mbH [GSI]/Biophysik (Darmstadt, FRG) to identify possible electrophysiological changes and/or activation of protective mechanisms in response to pulsed radiation. Offline data analyses are in progress and observations are still anecdotal. Electrophysiological changes after pulsed radiation are within the limits of spontaneous variability under anesthesia, with only indirect evidence of possible retinal/cortical responses. Immunostaining showed changes (e.g. increased expression of FGF2 protein in the outer nuclear layer) suggesting a retinal stress reaction to high-energy particles of potential relevance in space. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

NASA Center JSC↗

Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System From Adaptive Detector Movements

To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Recent accelerated diversification in rosids occurred outside the tropics

Conflicting relationships have been found between diversification rate and temperature across disparate clades of life. Here, we use a supermatrix comprising nearly 20,000 species of rosids—a clade of ~25% of all angiosperm species—to understand global patterns of diversification and its climatic association. Our approach incorporates historical global temperature, assessment of species’ temperature niche, and two broad-scale characterizations of tropical versus non-tropical niche occupancy. We find the diversification rates of most subclades dramatically increased over the last 15 million years (Myr) during cooling associated with global expansion of temperate habitats. Climatic niche is negatively associated with diversification rates, with tropical rosids forming older communities and experiencing speciation rates ~2-fold below rosids in cooler climates. Our results suggest long-term cooling had a disproportionate effect on non-tropical diversification rates, leading to dynamic young communities outside of the tropics, while relative stability in tropical climes led to older, slower-evolving but still species-rich communities.

59 BASIC BIOLOGICAL SCIENCES↗

Inflatable radar reflector unit Patent

Inflatable radar reflector unit - lightweight, highly reflective to electromagnetic radiation, and adaptable for erection and deployment with minimum effort and time

Radnofsky, M. I.↗

Array Feed To Compensate For Distortion In Antenna

System partly restores desired far-field radiation pattern. Adaptive array feed for paraboloidal-reflector antenna helps compensate for effects of slow changes in shape of reflecting surface. Counteracts distortion by illuminating reflector with wave fronts that have "opposite" distortion.

Rahmat-Samii, Y.↗

Compositions of near-Earth asteroids

Observational studies of near-earth asteroids and development of techniques for determining their composition were continued. The analysis techniques were applied to the spectra of several bodies in preparation for their application of near-earth asteroids. In mid-November 1989, near-IR observations of three near-earth atseroids, 1865 Cerberus, 1989 VA, and 1989 VB, were made. These asteroids were observed in six broadband visual and near-IR filters (0.4 to 2.5 microns), and a few narrowband measurements in the IR were obtained, but the asteroids were too faint to measure beyond 2.5 microns. Simultaneous, high-resolution visual CCD spectra were measured for these objects, but the data were not yet reduced to determine their quality. Narrowband spectra of the Martian satellite Deimos in the 1 to 3 micron spectral region were obtained. Simultaneous with the observing project, laboratory studies of meteorites and meteorite analogs which are used in spectral analysis of the telescopic data are continuing to be performed. Extensive work was performed in developing applications of Hapke reflectance theory to compositional analysis. Hapke theory is an adaptation of radiative reflectance theory to particulate surfaces.

Lebofsky, Larry A.↗