Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Aberration correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Isotope-Resolved Electron Energy Loss Spectroscopy in a Monochromated Scanning Transmission Electron Microscope

The development and implementation of high-stability monochromators in state-of-the-art aberration-corrected scanning transmission electron microscopes has enabled materials characterization with an energy resolution as good as 3 meV. This allows the vibrational modes, which would otherwise be obscured by the energy spread of the electron beam, to be probed with very high precision in molecular materials. Since the vibrational energies depend on the weight of the atomic nuclei, vibrational spectroscopy can distinguish isotopes whose only difference lies in their neutron content. This opens up isotopic analysis and mapping in transmission electron microscopy as two important new research areas. In this paper, we review the monochromated electron energy loss spectroscopy (EELS) instrumentation, discuss optimal methods for probing beam-sensitive materials without destroying them, and review key nanoscale isotope-resolved results.

47 OTHER INSTRUMENTATION↗

Mapping valence electron distributions with multipole density formalism using 4D-STEM

Recent advancement in aberration correction and detector technology opened a door to various applications using 4D-STEM, which yields a diffraction pattern for each scanning position within a crystal unit-cell in scanning transmission electron microscopy (STEM) and generates incredible amounts of data in momentum space. Currently 4D-STEM analysis relies on the center-of-mass of the diffraction patterns in electric field and charge density mapping. It only derives the total projected charge density and is limited to phase objects, e.g. extremely thin samples. Here, we propose a new analytical method to accurately map aspherical valence electron distributions with atom-centered multipolar functions formalism using the whole 4D-STEM dataset. We demonstrate that, with the full dynamical calculations for various sample thicknesses, the method is sensitive not only to the miniscule charge transfer, but also to the atomic site symmetry and aspherical electron orbitals. The process of the refinement is much more robust and reliable than quantitative convergent beam electron diffraction.

4D-STEM↗

Discovery of Dielectric Response and Forces in Sub-Nanoscale Objects (Final Technical Report)

This is the final technical report for DOE Award DE-SC0005132 entitled “Discovery of Dielectric Response and Forces in Sub-Nanoscale Objects.” This award originated on August 15, 2010 with Principle Investigator Prof. Phil Batson of Rutgers, The State University of New Jersey. Prof. Batson transitioned to Professor Emeritus status on January 31, 2023. At that time PI status was transferred to Prof. Robert Bartynski of the Department of Physics and Astronomy at Rutgers, The State University of New Jersey, and Director of the Rutgers Laboratory for Surface Modification. The central theme of the research performed under this award is develop and refine a NION aberration-corrected Scanning Transmission Electron Microscope to attain atomic spatial resolution and sub 10meV energy resolution in electron energy loss spectroscopy (EELS) performed on the transmitted electron beam. These capabilities allow examination of the excitation properties (primarily plasmonic and vibrational [ie., phonons] of nanoscale objects when excited with a highly-localized (~ Angstrom-scale) high energy (~ 60 keV) electron beam. Direct excitations (i.e., the response to electrons impinging directly on the sample) as well as excitations in response to the dynamic electric (and magnetic!) fields of an aloof electron beam (i.e., a beam that is close to but displaced from the target) have been studied. Our experimental work has benefited greatly from close collaborations with theoretical colleagues, but at Rutgers and from around the world, providing a much more complete understanding of the observed phenomena and suggesting avenues for further study and practical applications. This report summarizes the technical and scientific achievements accomplished during the entire award period. More extensive details are available in the Progress Reports that have already been filed with the Department of Energy. The report is divided into six sections. The first four sections focus on exploring, developing and understanding several unique capabilities and phenomena discovered and accessible owing to the high spatial- and energy-resolution we have been able to achieve. The latter two sections focus on applications of the STEM’s novel capabilities to study atomic- and nanometer-scale properties of solids, as well as broader applications to advanced and bio-materials.

47 OTHER INSTRUMENTATION↗

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE↗

Spherical Aberrations - Final Focus and Solenoid Scans

Conclusions: Spherical aberrations in solenoids are unavoidable and problematic whenever the beam is focused; It may be possible to include a spherical aberration correction to the analysis of a solenoid scan in the manner described above although more accurate 2D PIC models should be studied to determine the accuracy of the very simple model used above. This correction would have to be iterated as the beam size in the solenoid is iterated; A quadrupole triplet final focus would not have aberrations (preliminary analysis shows improvement in spot size, very difficult to tune).

43 PARTICLE ACCELERATORS↗

White-Light Phase-Conjugate Mirrors as Distortion Correctors

White-light phase-conjugate mirrors would be incorporated into some optical systems, according to a proposal, as means of correcting for wavefront distortions caused by imperfections in large optical components. The proposal was given impetus by a recent demonstration that white, incoherent light can be made to undergo phase conjugation, whereas previously, only coherent light was known to undergo phase conjugation. This proposal, which is potentially applicable to almost any optical system, was motivated by a need to correct optical aberrations of the primary mirror of the Hubble Space telescope. It is difficult to fabricate large optical components like the Hubble primary mirror and to ensure the high precision typically required of such components. In most cases, despite best efforts, the components as fabricated have small imperfections that introduce optical aberrations that adversely affect imaging quality. Correcting for such aberrations is difficult and costly. The proposed use of white-light phase conjugate mirrors offers a relatively simple and inexpensive solution of the aberration-correction problem. Indeed, it should be possible to simplify the entire approach to making large optical components because there would be no need to fabricate those components with extremely high precision in the first place: A white-light phase-conjugate mirror could correct for all the distortions and aberrations in an optical system. The use of white-light phase-conjugate mirrors would be essential for ensuring high performance in optical systems containing lightweight membrane mirrors, which are highly deformable. As used here, "phase-conjugate mirror" signifies, more specifically, an optical component in which incident light undergoes time-reversal phase conjugation. In practice, a phase-conjugate mirror would typically be implemented by use of a suitably positioned and oriented photorefractive crystal. In the case of a telescope comprising a primary and secondary mirror (see figure) white light from a distant source would not be brought to initial focus on one or more imaging scientific instrument(s) as in customary practice. Instead, the light would be brought to initial focus on a phase-conjugate mirror. The phase-conjugate mirror would send a phase-conjugate image back, along the path of the incoming light, to the primary mirror. A transparent, highly efficient diffractive thin film deposited on the primary mirror would direct the phase-conjugate image to the imaging instrument(s).

Frazier, Donald↗

Optical Design for CETUS a Wide-Field 1.5-m Aperture UV Payload Being Studied for a NASA Probe Class Mission Study

As part of a study funded by NASA headquarters, we are developing a probe-class mission concept called the Cosmic Evolution through UV Spectroscopy (CETUS). CETUS includes a 1.5-m aperture diameter telescope with a large field of view (FOV). CETUS includes three scientific instruments: a far ultraviolet (FUV) and near ultraviolet (NUV) imaging camera (CAM); a NUV multiobject spectrograph (MOS); and a dual-channel point/slit spectrograph (PSS) in the Lyman ultraviolet (LUV), FUV, and NUV spectral regions. The large FOV three-mirror anastigmatic (TMA) optical telescope assembly (OTA) simultaneously feeds the three separate scientific instruments. That is, the instruments view separate portions of the TMA image plane, enabling parallel operation by the three instruments. The field viewed by the MOS, whose design is based on an Offner-type spectrographic configuration to provide wide FOV correction, is actively configured to select and isolate numerous field sources using a next-generation micro-shutter array. The two-channel CAM design is also based on an Offner-like configuration. The PSS performs high spectral resolution spectroscopy on unresolved objects over the NUV region with spectral resolving power, R ~ 40,000, in an echelle mode. The PSS also performs long-slit imaging spectroscopy at R ~ 20,000 in the LUV and FUV spectral regions with two aberration-corrected, blazed, holographic gratings used in a Rowland-like configuration. The optical system also includes two fine guidance sensors, and wavefront sensors that sample numerous locations over the full OTA FOV. In-flight wavelength calibration is performed by a wavelength calibration system, and flat-fielding is also performed, both using in-flight calibration sources. We describe the current optical design of CETUS and the major trade studies leading to the design.

space sensors↗

A transmission hologram for slitless spectrophotometry on a convergent telescope beam. 1. Focus and resolution

We report in this paper the test of a plane holographic optical element to be used as an aberration-corrected grating for a slitless spectrograph, inserted in a convergent telescope beam. Our long-term objective is the optimization of a specific hologram to switch the auxiliary telescope imager of the Vera Rubin Observatory into an accurate slitless spectrograph, dedicated to the atmospheric transmission measurement. We present and discuss here the promising results of tests performed with prototype holograms at the CTIO $0.9\,$m telescope during a run of 17 nights in 2017 May–June. After their on-sky geometrical characterization, the performances of the holograms as aberration-balanced dispersive optical elements have been established by analysing spectra obtained from spectrophotometric standard stars and narrow-band emitter planetary nebulae. Thanks to their additional optical function, our holographic disperser prototypes allow us to produce significantly better focused spectra within the full visible wavelength domain $[370,1050]\,$nm than a regular grating, which suffers from strong defocusing and aberrations when used in similar conditions. We show that the resolution of our slitless on-axis spectrograph equipped with the hologram approaches its theoretical performance. While estimating the benefits of a hologram for the spectrum resolution, the roadmap to produce a competitive holographic element for the Vera Rubin Observatory auxiliary telescope has been established.

79 ASTRONOMY AND ASTROPHYSICS↗

Atomic-scale Imaging of PGM-free Catalyst Active Sites by 30 keV 4D-STEM

Platinum group metal (PGM)-free catalysts have attracted a large amount of attention due to their potential for enabling low-cost, commercially viable hydrogen fuel cells and electrolyzers [1]. Degradation of cell performance remains a significant challenge, however, currently limiting implementation of devices that utilize PGM-free materials [2]. Controlling degradation in these materials requires a better understanding of the atomic structure of active sites, thought to be FeN4 structures within a graphitic carbon lattice, which would enable more accurate prediction of the associated degradation pathways. The exact structural arrangement of active sites in these materials is still debated since a range of structures have been computationally predicted and methods to directly validate these models are still needed [1,3-5].While scanning transmission electron microscopy (STEM) has provided initial glimpses into the nature of the proposed active sites, detailed evaluation of the structure of these sites is challenging since they involve defects, edges, and nitrogen dopants in the graphitic lattice, which are susceptible to beam damage [6,7]. Conventional STEM imaging and spectroscopy methods exacerbate this problem with dose-inefficiency or nonideal contrast characteristics for imaging light and heavy elements simultaneously. A method that minimizes damage while generating dose-efficient, easily-interpretable contrast for both light and heavy elements is therefore needed to facilitate imaging of sensitive active site atomic structure.Here, we demonstrate direct atomic-scale imaging of PGM-free catalyst active sites by low-voltage four-dimensional (4D)-STEM. To accomplish this, we pair a 30 keV aberration-corrected probe, which minimizes knock-on damage, with a fast pixelated detector that has optimal performance at low beam energies [8]. We show how this setup enables relatively simple center-of-mass (CoM) techniques [9,10] to produce images with an increased signal-to-noise ratio (SNR) and light-element contrast over conventional imaging modes, allowing the entire active site structure to be imaged at the atomic scale. Moreover, we show how electron ptychography [11,12] enables images with further improved characteristics to be obtained, for example by minimizing residual aberrations, which provides a more accurate structural representation. The increased understanding that these low-voltage 4D-STEM techniques will provide about the atomic structure of PGM-free active sites and their associated degradation pathways will facilitate rational design of next-generation materials, promoting development of low-cost hydrogen fuel cells, electrolyzers, and other energy conversion devices [13]. References:[1] U Martinez et al., Adv. Mater. 31 (2019), p. 1806545.[2] Y Shao et al., Adv. Mater. 31 (2019), p. 1807615.[3] J Kneebone et al., J. Phys. Chem. C 121, (2017), p.16283.[4] T Mineva et al., ACS Catal. 9 (2019), p. 9359.[5] J Li et al., Nat. Catal. 4 (2021), p. 10.[6] T Susi et al., ACS Nano 6 (2012), p. 8837.[7] P Zelenay and DJ Myers, US Department of Energy Hydrogen and Fuel Cells Program 2017 Annual Merit Review and Peer Evaluation Meeting, Washington, DC (2017).[8] H Ryll et al., J. Inst. 11 (2016), p. P04006.[9] K Müller et al., Nat. Commun. 5 (2014), p. 5653.[10] I Lazic et al., Ultramicroscopy 160 (2016), p. 265.[11] H Yang et al., Nat. Commun. 7 (2016), p. 12532.[12] Y Jiang et al., Nature 559 (2018), p. 343. [13] Research sponsored by the Hydrogen and Fuel Cell Technologies Office, Office of Energy Efficiency and Renewable Energy, US Department of Energy (DOE). Research was conducted at the Center for Nanophase Materials Sciences, which is a DOE Office of Science User Facility.

Zachman, Michael↗

van der Waals Semiconductor Empowered Vertical Color Sensor

We report biomimetic artificial vision is receiving significant attention nowadays, particularly for the development of neuromorphic electronic devices, artificial intelligence, and microrobotics. Nevertheless, color recognition, the most critical vision function, is missed in the current research due to the difficulty of downscaling of the prevailing color sensing devices. Conventional color sensors typically adopt a lateral color sensing channel layout and consume a large amount of physical space, whereas compact designs suffer from an unsatisfactory color detection accuracy. In this work, we report a van der Waals semiconductor-empowered vertical color sensing structure with the emphasis on compact device profile and precise color recognition capability. More attractive, we endow color sensor hardware with the function of chromatic aberration correction, which can simplify the design of an optical lens system and, in turn, further downscales the artificial vision systems. Also, the dimension of a multiple pixel prototype device in our study confirms the scalability and practical potentials of our developed device architecture toward the above applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical Performance Prediction of the Thirty Meter Telescope after Initial Alignment Using Optical Modeling

We present an estimate of the optical performance of the Thirty Meter Telescope (TMT) after execution of the full telescope alignment plan. The TMT alignment is performed by the Global Metrology System (GMS) and the Alignment and Phasing System (APS). The GMS first measures the locations of the telescope optics and instruments as a function of elevation angle. These initial measurements will be used to adjust the optics positions and build initial elevation look-up tables. Then the telescope is aligned using starlight as the input for the APS at multiple elevation angles. APS measurements are used to refine the telescope alignment to build elevation and temperature dependent look-up tables. Due to the number of degrees of freedom in the telescope (over 10,000), the ability of the primary mirror to correct aberrations on other optics, the tight optical performance requirements and the multiple instrument locations, it is challenging to develop, test and validate these alignment procedures. In this paper, we consider several GMS and APS operational scenarios. We apply the alignment procedures to the model-generated TMT, which consists of various quasi-static errors such as polishing errors, passive supports errors, thermal and gravity deformations and installation position errors. Using an integrated optical model and Monte-Carlo framework, we evaluate the TMT’s aligned states using optical performance metrics at multiple instrument and field of view locations. The optical performance metrics include the Normalized Point Source Sensitivity (PSSN), RMS wavefront error before and after Adaptive Optics (AO) correction, pupil position change, and plate scale distortion.

Rogers, John↗

Optical Modeling Activities for NASA's James Webb Space Telescope (JWST): Wavefront Aberrations due to Alignment and Figure Compensation - 3

This is part three of a series describing the ongoing optical modeling activities for James Webb Space Telescope (JWST). The first two discussed modeling JWST on-orbit performance using wavefront sensitivities to predict line of sight motion induced blur, and stability during thermal transients. The work here investigates the aberrations resulting from alignment and figure compensation of the controllable degrees of freedom (primary and secondary mirrors), which may be encountered during ground alignment and on-orbit commissioning of the observatory. The optical design of the telescope is a three-mirror anastigmat, with an active fold mirror at the exit pupil for fine guiding. The primary mirror is over 6.5 meters in diameter, and is composed of 18 hexagonal segments that can individually positioned on hexapods, as well as compensated for radius of curvature. This effectively gives both alignment and figure control of the primary mirror. The secondary mirror can be moved in rigid body only, giving alignment control of the telescope. The tertiary mirror is fixed, however, as well as the location of the science instrumentation. Simulations are performed of various combinations of active alignment corrections of component figure errors, and of primary mirror figure corrections of alignment errors. Single field point and moderate field knowledge is assumed in the corrections. Aberrations over the field are reported for the varying cases, and examples presented.

Howard, Joseph↗

Direct Visualization of Localized Vibrations at Complex Grain Boundaries

Abstract Grain boundaries (GBs) are a prolific microstructural feature that dominates the functionality of a wide class of materials. The functionality at a GB results from the unique atomic arrangements, different from those in the grain, that have driven extensive experimental and theoretical studies correlating atomic‐scale GB structures to macroscopic electronic, infrared optical, and thermal properties. In this work, a SrTiO 3 GB is examined using atomic‐resolution aberration‐corrected scanning transmission electron microscopy and ultrahigh‐energy‐resolution monochromated electron energy‐loss spectroscopy, in conjunction with density functional theory. This combination enables the correlation of the GB structure, nonstoichiometry, and chemical bonding with a redistribution of vibrational states within the GB dislocation cores. The new experimental access to localized GB vibrations provides a direct route to quantifying the impact of individual boundaries on macroscopic properties.

36 MATERIALS SCIENCE↗

The Atomic Drill Bit: Precision Controlled Atomic Fabrication of 2D Materials

The ability to deterministically fabricate nanoscale architectures with atomic precision is the central goal of nanotechnology, whereby highly localized changes in the atomic structure can be exploited to control device properties at their fundamental physical limit. Here, an automated, feedback-controlled atomic fabrication method is reported and the formation of 1D–2D heterostructures in MoS 2 is demonstrated through selective transformations along specific crystallographic orientations. The atomic-scale probe of an aberration-corrected scanning transmission electron microscope (STEM) is used, and the shape and symmetry of the scan pathway relative to the sample orientation are controlled. The focused and shaped electron beam is used to reliably create Mo 6 S 6 nanowire (MoS-NW) terminated metallic-semiconductor 1D–2D edge structures within a pristine MoS 2 monolayer with atomic precision. From these results, it is found that a triangular beam path aligned along the zig-zag sulfur terminated (ZZS) direction forms stable MoS-NW edge structures with the highest degree of fidelity without resulting in disordering of the surrounding MoS 2 monolayer. Density functional theory (DFT) calculations and ab initio molecular dynamic simulations (AIMD) are used to calculate the energetic barriers for the most stable atomic edge structures and atomic transformation pathways. These discoveries provide an automated method to improve understanding of atomic-scale transformations while opening a pathway toward more precise atomic-scale engineering of materials.

2D materials↗

Top-Down Fabrication of Atomic Patterns in Twisted Bilayer Graphene

Atomic-scale engineering typically involves bottom-up approaches, leveraging parameters such as temperature, partial pressures, and chemical affinity to promote spontaneous arrangement of atoms. These parameters are applied globally, resulting in atomic-scale features scattered probabilistically throughout the material. In a top-down approach, different regions of the material are exposed to different parameters, resulting in structural changes varying on the scale of the resolution. In this work, the application of global and local parameters is combined in an aberration-corrected scanning transmission electron microscope (STEM) to demonstrate atomic-scale precision patterning of atoms in twisted bilayer graphene. The focused electron beam is used to define attachment points for foreign atoms through the controlled ejection of carbon atoms from the graphene lattice. The sample environment is staged with nearby source materials such that the sample temperature can induce migration of the source atoms across the sample surface. Under these conditions, the electron-beam (top-down) enables carbon atoms in the graphene to be replaced spontaneously by diffusing adatoms (bottom-up). Using image-based feedback control, arbitrary patterns of atoms and atom clusters are attached to the twisted bilayer graphene with limited human interaction. Finally, the role of substrate temperature on adatom and vacancy diffusion is explored by first-principles simulations.

36 MATERIALS SCIENCE↗

Reward Driven Workflows for Unsupervised Explainable Analysis of Phases and Ferroic Variants From Atomically Resolved Imaging Data

Rapid progress in aberration corrected electron microscopy necessitates development of robust methods for the identification of phases, ferroic variants, and other pertinent aspects of materials structure from imaging data. While unsupervised methods for clustering and classification are widely used for these tasks, their performance can be sensitive to hyperparameter selection in the analysis workflow. In this study, the effects of descriptors and hyperparameters are explored on the capability of unsupervised ML methods to distill local structural information, exemplified by the discovery of polarization and lattice distortion in Sm − dopped BiFeO 3 (BFO) thin films. It is demonstrated that a reward-driven approach can be used to optimize these key hyperparameters across the full workflow, where rewards are designed to reflect domain wall continuity and straightness, ensuring that the analysis aligns with the material's physical behavior. This approach allows the discovery of local descriptors that are best aligned with the specific physical behavior, providing insight into the fundamental physics of materials. The reward driven workflow is further extended to disentangle structural factors of variation via an optimized variational autoencoder (VAE). Lastly, the importance of well-defined rewards is explored as a quantifiable measure of the success of the workflow.

Barakati, Kamyar [University of Tennessee, Knoxvil↗

Complex-Concentrated Anion Doping Enables Ultra-Stable Lattice Oxygen and Structural Integrity in Lithium-Rich Layered Oxide Cathodes

Lithium- and manganese-rich layered oxides (LMR) stand out as next-generation lithium-ion cathode chemistries, which harness both transition-metal and lattice-oxygen redox processes to deliver exceptional capacity and energy density. However, their full potential is hindered by intrinsic oxygen instability and structural degradation, resulting in pronounced voltage fade and capacity decay. Here, we present a complex-concentrated anion-doping paradigm in which multiple anions, F, Br, and S, are incorporated into the oxygen sublattice to enhance oxygen-redox and structural stability. X-ray absorption spectroscopy and aberration-corrected scanning transmission electron microscopy confirm ultra-stable local oxygen coordination environments during long-term cycling, with detrimental phase transformations and oxygen-loss-induced cavitation dramatically inhibited. Notably, we show that the characteristic LiTM6 transition metal (TM) honeycomb ordering is preserved even after electrochemical cycling. Concurrently, this strategy yields an unprecedented volume change of only 0.63% upon charging to 4.8 V vs. Li+/Li, achieving the first zero-strain LMR cathode. The resulting LMR cathode delivers ultralow voltage fade (1 mV per cycle during the first 100 cycles and becomes negligible in subsequent cycles) and outstanding energy retention (93% after 200 cycles) in a pouch cell configuration. Our complex-concentrated anion-doping concept establishes a broadly applicable strategy for resolving chemo-mechanical failure mechanisms in ceramic intercalation electrodes for next-generation energy storage.

Li-ion batteries↗