At least 55 records · Page 3

ASTROS - A sub-arcsec CCD star tracker

The design and application of ASTROS (Advanced Star and Target Reference Optical Sensor) are described, with emphasis on performance test results acquired with a prototype system. The ASTROS tracker provides extremely precise measurements of star image coordinates as inputs to the Image Motion Compensation (IMC) system used to stabilize the science instrument focal planes. Performance levels achieved are dramatic improvements over the levels achieved with image dissector designs with comparable fields of view.

Stanton, R. H.↗

Acquisition and track algorithms for the Astros star tracker

The Astros star tracker has been designed for an employment with the Space Shuttle. An achievement of the performance levels needed has required critical trade-offs between the hardware design and the control algorithms. This paper provides a description of the development of the acquisition and track algorithms. Attention is given to an Astros system overview, a system firmware description, cluster evaluation, guide star selection, exposure time determination, video data input, update interval timing, exposure time sequencing full frame video A/D conversion, analog threshold for acquisition, minimum threshold determination, and the theoretical basis for the track algorithm.

Shalom, E.↗

ASTROS: A multidisciplinary automated structural design tool

ASTROS (Automated Structural Optimization System) is a finite-element-based multidisciplinary structural optimization procedure developed under Air Force sponsorship to perform automated preliminary structural design. The design task is the determination of the structural sizes that provide an optimal structure while satisfying numerous constraints from many disciplines. In addition to its automated design features, ASTROS provides a general transient and frequency response capability, as well as a special feature to perform a transient analysis of a vehicle subjected to a nuclear blast. The motivation for the development of a single multidisciplinary design tool is that such a tool can provide improved structural designs in less time than is currently needed. The role of such a tool is even more apparent as modern materials come into widespread use. Balancing conflicting requirements for the structure's strength and stiffness while exploiting the benefits of material anisotropy is perhaps an impossible task without assistance from an automated design tool. Finally, the use of a single tool can bring the design task into better focus among design team members, thereby improving their insight into the overall task.

Neill, D. J.↗

A mass additive technique for modal testing as applied to the Space Shuttle ASTRO-1 payload

Traditionally, a fixed base modal test has been performed as a means of verifying the coupled loads math model for Space Shuttle flight payloads. An alternate method, a free-free configured payload using mass loaded boundary conditions, is presented as a means of verifying the coupled loads model of the ASTRO-1 flight payload. This method allows evaluation of the influence of local load paths into the frequency range of the free-free test. The method is cost effective and does not contaminate the modal test results with fixture coupled modes or boundary condition uncertainties. This paper describes the mass additive modal test technique as applied to the Space Shuttle ASTRO-1 flight payload.

Coleman, A. D.↗

Astro - Observatory in a Shuttle

This paper discusses the Astro, a UV and X-ray observatory designed for the Space Shuttle Columbia, which is scheduled for the May 7, 1990 launch. Astro's four telescopes and their operation are described. They are the Hopkins Ultraviolet Telescope, the Wisconsin Ultraviolet Photo-Polarimeter Experiment, the Ultraviolet Imaging Telescope, and the Broad Band X-ray Telescope. Attention is also given to the mission plan and to the ground operations.

Blair, William P.↗

The Astro-1 Observatory mission

This paper describes the NASA's Astro-1 Observatory mission. The three ultraviolet (UV) telescopes and one X-ray telescope that make up this Spacelab mission will observe objects in the solar system, including comets and the outer planets, objects within the Milky Way Galaxy, and high-energy extragalactic objects such as quasi-stellar objects and active galaxies. While briefly discussing the science objectives of the mission, the paper focuses on the history of the mission, the Spacelab hardware assembled by the George C. Marshall Space Flight Center (MSFC) to carry the telescopes into orbit, and the complexities of the systems supporting that payload. Also discussed are the dimensions and capabilities of the Hopkins Ultraviolet Telescope, the Ultraviolet Imaging Telescope, the Wisconsin Ultraviolet Photopolarimeter Experiment, and the Broad Band X-Ray Telescope, all of which will coobserve a number of targets to generate comprehensive data in both the ultraviolet and X-ray ranges of the spectrum. The Astro-1 mission operations are described, and the cooperative functions of other NASA centers are reported.

Jones, Jack↗

Large scale optimization using ASTROS: An overview

Interest in interdisciplinary systems is widespread around the world. A number of structural optimization systems are being developed and tested. Some examples are listed here. ASOP, FASTOP, and TSO are programs developed for the Air Force Flight Dynamics Laboratory during the seventies. These programs established the feasibility of integrating various disciplines. The program 'STARS' is basically a structural optimization system developed by the Royal Aircraft Establishment (RAE) in England. At present, it is being enhanced to include aeroelasticity. 'LAGRANGE' is an optimization system developed by MBB in Germany. ELFINI is a similar system developed in France. It is being marketed in the U.S. as well as other countries. The Automated STRuctural Optimization System (ASTROS) was developed for the Flight Dynamics Directorate of Wright Laboratory. The ASTROS system is described in viewgraph form.

Venkayya, Vipperia B.↗

Orbiter attitude design for the Astro-1 Spacelab mission

The methods utilized to design orbiter attitudes that satisfied the various Space Shuttle program and payload constraints of the Astro-1 Spacelab astronomy mission are described. The premission methods developed for attitude design and how those methods were applied to accomplish the large amount of real-time replanning required during the flight are presented. Some of the attitude concerns for Astro-1 included orbiter window thermal constraints, two separate telescope fields-of-view, tracking and data relay satellite Ku-band access, and telescope sun avoidance.

Olsen, C. D.↗

An introduction to the Astro Edge solar array

The Astro Edge solar array is a new and innovative low concentrator power generating system which has been developed for applications requiring high specific power, high stiffness, low risk, light modular construction which utilizes conventional materials and technology, and standard photovoltaic solar cells and laydown processes. Mechanisms, restraint/release devices, wiring harnesses, substrates, and support structures are designed to be simple, functional, lightweight, and modular. A brief overview of the Astro Edge solar array is discussed.

Spence, B. R.↗

STS-35: Astro-1 BBXRT Problem Area

The primary objective of STS-35 was to conduct observations in ultraviolet and X-ray astronomy with the ASTRO-1 observatory. ASTRO-1 consisted of four telescopes: Hopkins Ultraviolet Telescope (HUT); Wisconsin Ultraviolet Photo-Polarimeter Experiment (WUPPE); Ultraviolet Imaging Telescope (UIT); and Broad Band X-ray Telescope (BBXRT). This videotape shows work on the BBXRT in the clean room. Two days before a scheduled September 1 launch date, the avionics box on the BBXRT malfunctioned and had to be changed and retested.

Source record↗

Development of the ASTRO-H Soft X-ray Telescope (SXT): Engineering Model Performance

The X-ray astronomy satellite ASTRO-H, being developed under the collaboration among JAXA, NASA's GSFC and ESA, will have two Soft X-ray Telescopes (SXTs), among other instuments onboard, with a sensitive energy band below 12 keV. One is for an X-ray micorocalorimeter detector and the other for a X-ray CCD detector. The SXT uses a conically approximated Wolter I grazing incidence optic implemented by thin aluminum foil substrates with thickness of 0.152, 0.229, and 0.305 mm. It is similar to the Suzaku XRT, but with larger diameter (45 cm) and longer focal length (5.6 m). Goal of the angular resolution and effective area are 1 arcmin and 390 cm$A2$ at 6 keV, respectively. We made serveral improvements from Suzaku to ASTRO-H, such as thicker substrates, more forming mandrels, thinner epoxy layer for replication, stiffer housings, precise alignment bars, etc. With all these changes, we have fabricated the engineering test unit of the SXT. In this paper, we will discuss all the changes made, their effects, and report X-ray performance of the SXT test unit. An angular resolution of the test unit was measured at new Goddard X-ray calibration facility (100 m X-ray beamline) and was found to be 1.1 arcmin. We will also discuss further improvements toward the flight unit to be delivered to JAXA in 2012.

Okajima, Takashi↗

ASTRO-H Soft X-Ray Telescope (SXT)

ASTRO-H is an astrophysics satellite dedicated for X-ray spectroscopic study non-dispersively and to carry out survey complementally, which will be borne out of US-Japanese collaborative effort. Among the onboard instruments there are four conically approximated Wolter-I X-ray mirrors, among which two of them are soft X-ray mirrors\ of which the energy range is from a few hundred eV to 15 keY, currently being fabricated in the X-ray Optics Lab at Goddard Space Flight Center. The focal point instruments will be a calorimeter (SXS) and a CCD camera (SXI), respectively. The reflectors of the mirror are made of heat-formed aluminum substrate of the thickness gauged of 152 micron, 229 micron, and 305 micron of the alloy 5052 H-19, followed by epoxy replication on gold-sputtered smooth Pyrex cylindrical mandrels to acquire the X-ray reflective surface. The epoxy layer is 10 micron nominal and surface gold layer of 0.2 micron. Improvements on angular response over the Astro-El/Suzaku mirrors come from error reduction on the figure, the roundness, and the grazing angle/radius mismatching of the reflecting surface, and tighter specs and mechanical strength on supporting structure to reduce the reflector positioning and the assembly errors. In this paper, we report the results of calibration of the engineering model of SXT (EM), and project the quality of the flight mirrors.

Soong, Yang↗

On-Orbit Operation of the Adiabatic Demagnetization Refrigerator on the Astro-H/Hitomi Soft X-ray Spectrometer Instrument

The Soft X-ray Spectrometer instrument on the Astro-H observatory contains a 6x6 array of x-ray microcalorimeters, which is cooled to 50 mK by an adiabatic demagnetization refrigerator (ADR). The ADR consists of three stages in order to provide stable detector cooling using either a 1.2 K superfluid helium bath or a 4.5 K Joule-Thomson (JT) cryocooler as its heat sink. When liquid helium is present, two of the ADRs stages are used to single-shot cool the detectors while rejecting heat to the helium. After the helium is depleted, all three stages are used to cool both the helium tank (to about 1.5 K) and the detectors (to 50 mK) using the JT cryocooler as its heat sink. The Astro-H observatory, renamed Hitomi after its successful launch in February 2016, carried approximately 36 liters of helium into orbit. On day 5, the helium had cooled sufficiently (1.4 K) to allow operation of the ADR. This paper describes the design, operation and on-orbit performance of the ADR.

sub-kelvin refrigeration↗

The ASTRO-H (Hitomi) X-Ray Astronomy Satellite

The Hitomi (ASTRO-H) mission is the sixth Japanese X-ray astronomy satellite developed by a large international collaboration, including Japan, USA, Canada, and Europe. The mission aimed to provide the highest energy resolution ever achieved at E greater than 2 keV, using a microcalorimeter instrument, and to cover a wide energy range spanning four decades in energy from soft X-rays to gamma-rays. After a successful launch on 2016 February 17, the spacecraft lost its function on 2016 March 26, but the commissioning phase for about a month provided valuable information on the on-board instruments and the spacecraft system, including astrophysical results obtained from first light observations. The paper describes the Hitomi (ASTRO-H) mission, its capabilities, the initial operation, and the instruments/spacecraft performances confirmed during the commissioning operations for about a month.

Hard X-ray↗

Astro-H/Hitomi Data Analysis, Processing, and Archive

Astro-H is the x-ray/gamma-ray mission led by Japan with international participation, launched on February 17, 2016. Soon after launch, Astro-H was renamed Hitomi. The payload consists of four different instruments (SXS, SXI, HXI, and SGD) that operate simultaneously to cover the energy range from 0.3 keV up to 600 keV. On March 27, 2016, JAXA lost contact with the satellite and, on April 28, they announced the cessation of the efforts to restore mission operations. Hitomi collected about one months worth of data with its instruments. This paper presents the analysis software and the data processing pipeline created to calibrate and analyze the Hitomi science data, along with the plan for the archive. These activities have been a collaborative effort shared between scientists and software engineers working in several institutes in Japan and United States.

Angelini, Lorella↗

Performance Testing of the Astro-H Flight Model 3-Stage ADR

The Soft X-ray Spectrometer (SXS) is one of four instruments that will be flown on the Japanese Astro-H satellite, planned for launch in late 2015early 2016. The SXS will perform imaging spectroscopy in the soft x-ray band using a 6x6 array of silicon micro calorimeters operated at 50 mK, cooled by an adiabatic demagnetization refrigerator (ADR). NASAGSFC is providing the detector array and ADR, and Sumitomo Heavy Industries, Inc. is providing the remainder of the cryogenic system (superfluid helium dewar (1.3 K), Stirling cryocoolers and a 4.5 K Joule-Thomson (JT) cryocooler). The ADR is unique in that it is designed to use both the liquid helium and the JT cryocooler as it heat sink. The flight detector and ADR assembly have successfully undergone vibration and performance testing at GSFC, and have now undergone initial performance testing with the flight dewar at Sumitomo Heavy Industries, Inc. in Japan. This presentation summarizes the performance of the flight ADR in both cryogen-based and cryogen-free operating modes.

adiabatic demagnetization refrigerator↗

Study of the Residual Background Events in Ground Data from the ASTRO-HSXS Microcalorimeter

The measured instrumental background of the XRS calorimeter spectrometer of Suzaku had several sources, including primary cosmic rays and secondary particles interacting with the pixels and with the silicon structure of the array. Prior to the launch of Suzaku, several data sets were taken without x-ray illumination to study the characteristics and timing of background signals produced in the array and anti-coincidence detector. Even though the source of the background in the laboratory was different from that in low-earth orbit (muons and environmental gamma-rays on the ground versus Galactic cosmic-ray (GCR) protons and alpha particles in space), the study of correlations and properties of populations of rare events was useful for establishing the preliminary screening parameters needed for selection of good science data. Sea-level muons are singly charged minimum-ionizing particles, like the GCR protons, and thus were good probes of the effectiveness of screening via the signals from the anti-coincidence detector. Here we present the first analysis of the on-ground background of the SXS calorimeter of Astro-H. On XRS, the background prior to screening was completely dominated by coincident events on many pixels resulting from the temperature pulse arising from each large energy deposition (greater than 200 keV) into the silicon frame around the array. The improved heat-sinking of the SXS array compared with XRS eliminated these thermal disturbances, greatly reducing the measured count rate in the absence of illumination. The removal of these events has made it easier to study the nature of the residual background and to look for additional event populations. We compare the SXS residual background to that measured in equivalent ground data for XRS and discuss these preliminary results.

ASTRO-H↗

The Design, Implementation, and Performance of the Astro-H SXS Calorimeter Array and Anti-Coincidence Detector

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The SXS has a square array of 36 microcalorimeters at the focal plane. These calorimeters consist of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices have demonstrated a resolution of better than 4.5 eV at 6 keV when operated at a heat-sink temperature of 50 mK. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, resistance function, absorber details, and means of attaching the absorber to the thermistor-bearing element. We will also present the thermal characterization of the whole array, including thermal conductance and crosstalk measurements and the results of pulsing the frame temperature via alpha particles, heat pulses, and the environmental background. A silicon ionization detector is located behind the calorimeter array and serves to reject events due to cosmic rays. We will briefly describe this anti-coincidence detector and its performance.

x-ray calorimeter↗