Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTERIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Systemic Artery to Pulmonary Artery Fistula Associated with Mitral Regurgitation: Successful Treatment with Endovascular Embolization

We present the case of a 60-year-old woman with symptomatic mitral regurgitation caused by a left-to-right shunt via anastomoses consisting of microfistulae, most likely of inflammatory origin, between the right subclavian artery and the right pulmonary artery. The three arteries responsible for fistulous formation, including the internal mammary, thyrocervical, and lateral thoracic arteries, were successfully occluded by transcatheter embolization using superabsorbent polymer microsphere (SAP-MS) particles combined with metallic coils. No complications have been identified following treatment with SAP-MS particles. This approach significantly reduced the patient's mitral regurgitation and she has remained asymptomatic for more than 4 years.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of a Ruptured Profunda Femoral Artery Branch After Fogarty Thrombectomy of a Femoro-Femoral Crossover Arterial Graft: A Case Report and Review of the Literature

We present a very rare case of a life-threatening rupture of a profunda femoral artery distal branch after a Fogarty thrombectomy of a thrombosed crossover synthetic graft between the ipsilateral common femoral artery and a contralateral iliac-popliteal graft; the bleeding profunda femoral artery branch was successfully embolized with metallic coils through the axillary artery approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neurofibromatosis Type 1: Transcatheter Arterial Embolization for Ruptured Occipital Arterial Aneurysms

Two cases of ruptured aneurysms in the posterior cervical regions associated with type-1 neurofibromatosis treated by transcatheter embolization are reported. Patients presented with acute onset of swelling and pain in the affected areas. Emergently performed contrast-enhanced CT demonstrated aneurysms and large hematomas widespread in the posterior cervical regions. Angiography revealed aneurysms and extravasations of the occipital artery. Patients were successfully treated by percutaneous transcatheter arterial microcoil embolization. Transcatheter arterial embolization therapy was found to be an effective method for treating aneurysmal rupture in the posterior cervical regions occurring in association with type-1 neurofibromatosis. A literature review revealed that rupture of an occipital arterial aneurysm, in the setting of neurofibromatosis type 1, has not been reported previously.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Large Posttraumatic Subclavian Artery Aneurysm Complicated by Artery Occlusion and Arteriobronchial Fistula Successfully Treated Using a Covered Stent

The treatment of posttraumatic aneurysms of peripheral arteries using covered stents is increasingly commonplace. We present the case of a 10-year-old girl with a pseudoaneurysm of the subclavian artery complicated by an arteriobronchial fistula with hemorrhaging into the bronchial tree and distal subclavian artery occlusion. Despite the lack of artery patency, endovascular stent graft implantation was successful. Pseudoaneurysm exclusion and involution was achieved, together with a patent implant and maintained collateral circulation patency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aberrant Left Inferior Bronchial Artery Originating from the Left Gastric Artery in a Patient with Acute Massive Hemoptysis

Massive hemoptysis is a life-threatening condition, and the major source of bleeding in this condition is the bronchial circulation. Bronchial artery embolization is a safe and effective treatment for controlling hemoptysis. However, the sites of origin of the bronchial arteries (BAs) have numerous anatomical variations, which can result in a technical challenge to identify a bleeding artery. We present a rare case of a left inferior BA that originated from the left gastric artery in a patient with recurrent massive hemoptysis caused by bronchiectasis. The aberrant BA was embolized, and hemoptysis has been controlled for 8 months.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiple Renal Artery Pseudoaneurysms in Patients Undergoing Renal Artery Embolization Following Partial Nephrectomy: Correlation with RENAL Nephrometry Scores

PurposeTo describe the incidence of multiple renal artery pseudoaneurysms (PSA) in patients referred for renal artery embolization following partial nephrectomy and to study its relationship to RENAL nephrometry scores.Materials and MethodsThe medical records of 25 patients referred for renal artery embolization after partial nephrectomy were retrospectively reviewed for the following parameters: size and number of tumors, RENAL nephrometry scores, angiographic abnormalities, technical and clinical outcomes, and estimated glomerular filtration rates (eGFRs) after embolization.ResultsTwenty-four patients had primary renal tumors, while 1 patient had a pancreatic tumor invading the kidney. Multiple tumors were resected in 4 patients. Most patients (92 %) were symptomatic, presenting with gross hematuria, flank pain, or both. Angiography revealed PSA with (n = 5) or without (n = 20) AV fistulae. Sixteen patients (64 %) had multiple PSA involving multiple renal vessels. Higher RENAL nephrometry scores were associated with an increasing likelihood of multiple PSA. Multiple vessels were embolized in 14 patients (56 %). Clinical success was achieved after one (n = 22) or two (n = 3) embolization sessions in all patients. Post-embolization eGFR values at different time points after embolization were not significantly different from the post-operative eGFR.ConclusionA majority of patients requiring renal artery embolization following partial nephrectomy have multiple pseudoaneurysms, often requiring selective embolization of multiple vessels. Higher RENAL nephrometry score is associated with an increasing likelihood of multiple pseudoaneurysms. We found transarterial embolization to be a safe and effective treatment option with no long-term adverse effect on renal function in all but one patient with a solitary kidney.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Iatrogenic celiac and hepatic artery dissections during intra-arterial regional tumor therapies: a 16-year retrospective review

Purpose: To identify the incidence and outcomes of iatrogenic celiac and hepatic artery dissections during transarterial therapies, including bland embolization, chemoembolization, radioembolization (TARE), and pre-TARE scintigraphic mapping. Methods: The institution’s quality assessment database, electronic medical record, and picture archiving and communication system were reviewed to identify all patients who underwent transarterial locoregional therapy from 1/2001 to 7/2017 and to determine the incidence of iatrogenic dissection, to assess patency of the arteries after dissection, and to assess the ability to complete therapy. Results: 2253 patients underwent 3776 transarterial hepatic oncology procedures. Among 3776 procedures, 40 (1.1%) were associated with dissection of the visceral vasculature, affecting 39 patients (1.7%). The incidence of flow-limiting dissections was 0.3% (13/3776) and non-flow-limiting dissections was 0.7% (27/3776). After dissection, 68% (27/40) of treatments were completed the same day. Among the 13 aborted treatments, 8 (62%) were completed on a subsequent encounter. Follow-up imaging was obtained in 26 of 40 cases at median time of 63 days. Complete resolution of the dissection was seen in 15/26 cases (58%), near complete resolution (< 30% luminal narrowing) in 3/26 (12%), unchanged appearance of a non-flow-limiting dissection in 4/26 (15%), progressive luminal narrowing in 3/26 (12%), and complete occlusion in 1/26 (4%). Conclusion: Iatrogenic dissections of visceral arteries rarely occur during tumor embolization procedures. 35/39 (90%) of patients underwent successful treatment despite the dissection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Embolization of Bronchial Artery Arising from Left Circumflex Coronary Artery in a Patient with Massive Hemoptysis

It has been reported that anastomoses between the bronchial and the coronary arteries can become dilated and functional in certain diseases, provoking angina pectoris through coronary steal syndrome. The condition can be treated with endovascular or surgical management. It is possible that this abnormality may be associated with hemoptysis in patients with parenchymal or vascular disease of the lung but this condition is very rare. We present the coronary CT angiographic findings of bronchial arteries arising from the left coronary artery and their treatment with transcatheter embolization for the control of massive hemoptysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deriving the Intrahepatic Arteriovenous Shunt Rate from CT Images and Biochemical Data Instead of from Arterial Perfusion Scintigraphy in Hepatic Arterial Infusion Chemotherapy

The purpose of the present study was to elucidate a method for predicting the intrahepatic arteriovenous shunt rate from computed tomography (CT) images and biochemical data, instead of from arterial perfusion scintigraphy, because adverse exacerbated systemic effects may be induced in cases where a high shunt rate exists. CT and arterial perfusion scintigraphy were performed in patients with liver metastases from gastric or colorectal cancer. Biochemical data and tumor marker levels of 33 enrolled patients were measured. The results were statistically verified by multiple regression analysis. The total metastatic hepatic tumor volume (V{sub metastasized}), residual hepatic parenchyma volume (V{sub residual}; calculated from CT images), and biochemical data were treated as independent variables; the intrahepatic arteriovenous (IHAV) shunt rate (calculated from scintigraphy) was treated as a dependent variable. The IHAV shunt rate was 15.1 {+-} 11.9%. Based on the correlation matrixes, the best correlation coefficient of 0.84 was established between the IHAV shunt rate and V{sub metastasized} (p < 0.01). In the multiple regression analysis with the IHAV shunt rate as the dependent variable, the coefficient of determination (R{sup 2}) was 0.75, which was significant at the 0.1% level with two significant independent variables (V{sub metastasized} and V{sub residual}). The standardized regression coefficients ({beta}) of V{sub metastasized} and V{sub residual} were significant at the 0.1 and 5% levels, respectively. Based on this result, we can obtain a predicted value of IHAV shunt rate (p < 0.001) using CT images. When a high shunt rate was predicted, beneficial and consistent clinical monitoring can be initiated in, for example, hepatic arterial infusion chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Hemostatic Durability between N-Butyl Cyanoacrylate and Gelatin Sponge Particles in Transcatheter Arterial Embolization for Acute Arterial Hemorrhage in a Coagulopathic Condition in a Swine Model

This study was designed to compare the efficacy of transcatheter arterial embolization (TAE) with N-butyl cyanoacrylate (NBCA) or gelatin sponge particles (GSP) for acute arterial bleeding in a coagulopathic condition using a swine model. Four healthy swine were divided into two coagulopathic conditions: mild and severe. Five hemorrhages were created in each swine (10 hemorrhages per coagulopathy). Mild coagulopathy was achieved by bloodletting 10% of the total circulatory whole blood and preserving activated clotting time (ACT) less than 200 s (ACT < 200 s state); severe coagulopathy was achieved by bloodletting 30% and preserving ACT > 400 s (ACT > 400-second state). For each state, of ACT < 200 s or ACT > 400 s, TAE was conducted with GSP or NBCA to control five hemorrhages arising from artificially created renal and splenic injuries. Angiography immediately after TAE with GSP or NBCA showed complete occlusion in both coagulopathic conditions. In the ACT < 200-second state, follow-up angiography at 5-30 min after TAE with GSP or NBCA showed no evidence of recurrent hemorrhage. In the ACT > 400-second state, follow-up angiography showed recurrent hemorrhage in four (80%) of the five hemorrhages embolized with GSP and in one (20%) of the five hemorrhages embolized with NBCA. Microscopically, red thrombi were observed densely surrounding GSP in mild coagulopathy but were scarce in severe coagulopathy. In a condition with severe coagulopathy, TAE with NBCA was more effective in durability to cease active arterial bleeding than with GSP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Iliac Artery Stent Placement Relieves Claudication in Patients with Iliac and Superficial Femoral Artery Lesions

Purpose. To evaluate the efficacy of iliac artery stent placement for relief of claudication in patients with both iliac and superficial femoral artery (SFA) lesions. Methods. Stent placement for only iliac artery occlusive disease was performed in 94 limbs (74 patients) with both iliac and SFA occlusive disease on the same limb. All procedures were performed because intermittent claudication did not improve after continuation of antiplatelet medication therapy and home-based exercise for 3 months. Rutherford classification was 2 in 20 limbs and 3 in 74 limbs. Patients with critical limb ischemia were excluded. Median duration of follow-up was 40 months. Primary patency rates of the iliac stent, clinical improvement rates, and risk factors for requiring additional SFA procedures were evaluated. Results. Primary patency rates of the iliac stent at 1, 3, 5, and 7 years were 97, 93, 79, and 79 %, respectively. The initial clinical improvement rate was 87 %. Continued clinical improvement rates at 1, 3, 5, and 7 years were 87, 81, 69, and 66 %, respectively. SFA Trans-Atlantic Inter-Society Consensus (TASC) II C/D lesion was a significant risk factor for requiring additional SFA procedures. Conclusion. Intermittent claudication was relieved by iliac stent placement in most patients with both iliac and SFA lesions. Thus, the indications for treatment of the SFA intended for claudicants should be evaluated after treatment of the iliac lesion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility and Safety of Vascular Closure Devices in an Antegrade Approach to Either the Common Femoral Artery or the Superficial Femoral Artery

Introduction: The purpose of the present study was to analyze complications following antegrade puncture of the common femoral artery (CFA) and the superficial femoral artery (SFA) using vascular closure systems (VCS). Methods: A single-center, retrospective study was performed after obtaining approval from the institutional review board and informed consent from all patients. At our center, the CFA or SFA are used for arterial access. All patients were evaluated clinically on the same day. If there was any suspicion of an access site problem, Duplex ultrasound was performed. Results: Access location was the CFA in 50 patients and the SFA in 130 patients. The sheath size ranged from 4F to 10F. Two patients had to be excluded because of lack of follow-up. Successful hemostasis was achieved in 162 of 178 cases (91 %). The following complications were observed in 16 patients (8.9 %): 4 pseudoaneurysms (2.2 %), 11 hematomas (6.2 %), and 1 vascular occlusion (0.5 %). The two pseudoaneurysms healed spontaneously, in one case an ultrasound-guided thrombin injection was performed, and one aneurysm was compressed manually. No further medical therapy was needed for the hematomas. The one vascular occlusion was treated immediately with angioplasty using a contralateral approach. No significant difference was noted between the CFA and the SFA group with respect to complications (p = 1.000). Conclusions: The use of closure devices for an antegrade approach up to 10F is feasible and safe. No differences in low complication rates were observed between CFA and SFA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

T-Stenting-and-Small-Protrusion Technique for Bifurcation Stenoses After End-to-Side Anastomosis of Transplant Renal Artery and External Iliac Artery: Report of Two Cases

Bifurcation stenoses after end-to-side anastomosis of transplant renal artery (TRA) and external iliac artery (EIA), including stenoses at the anastomosis and the iliac artery proximal to the TRA, are rare. In the present article, we report two successfully managed cases of bifurcation stenoses after end-to-side anastomosis of the TRA and EIA using the technique of T-stenting and small protrusion (TAP stenting)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of Ruptured Vertebral Artery Dissecting Aneurysms Distal to the Posterior Inferior Cerebellar Artery: Stenting or Trapping?

PurposeThe treatment of ruptured vertebral artery dissecting aneurysms (VADAs) continues to be controversial. Our goal was to evaluate the safety, efficacy, and long-term outcomes of internal trapping and stent-assisted coiling (SAC) for ruptured VADAs distal to the posterior inferior cerebellar artery (supra-PICA VADAs), which is the most common subset.MethodsA retrospective review was conducted of 39 consecutive ruptured supra-PICA VADAs treated with internal trapping (n = 20) or with SAC (n = 19) at our institution. The clinical and angiographic data were retrospectively compared.ResultsThe immediate total occlusion rate of the VADAs was 80 % in the trapping group, which improved to 88.9 % at the follow-ups (45 months on average). Unwanted occlusions of the posterior inferior cerebellar artery (PICA) were detected in three trapped cases. Incomplete obliteration of the VADA or unwanted occlusions of the PICA were detected primarily in the VADAs closest to the PICA. In the stenting group, the immediate total occlusion rate was 47.4 %, which improved to 100 % at the follow-ups (39 months on average). The immediate total occlusion rate of the VADAs was higher in the trapping group (p < 0.05), but the later total occlusion was slightly higher in the stenting group (p > 0.05).ConclusionsOur preliminary results showed that internal trapping and stent-assisted coiling are both technically feasible for treating ruptured supra-PICA VADAs. Although not statistically significant, procedural related complications occurred more frequently in the trapping group. When the VADAs are close to the PICA, we suggest that the lesions should be treated using SAC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role and Effectiveness of Percutaneous Arterial Embolization in Hemodynamically Unstable Patients with Ruptured Splanchnic Artery Pseudoaneurysms

PurposeTo assess the role and effectiveness of percutaneous arterial embolization (TAE) in patients with hemodynamic instability due to hypovolemic shock secondary to ruptured splanchnic artery pseudoaneurysms (SAPA).Materials and MethodsSeventeen patients (11 men, 6 women; mean age, 53 years) with hemodynamic instability (systolic blood pressure <90 mmHg) due to hypovolemic shock secondary to ruptured SAPA were treated by TAE. Clinical files, multidetector row computed tomography angiography, and angiographic examinations along with procedure details were reviewed.ResultsSeventeen SAPAs were present, predominantly located on gastroduodenal or pancreatic arteries (9/17; 53 %). Angiography showed extravasation of contrast medium from SAPA in 15/17 patients (88 %). Technical success rate of TAE was 100 %. TAE was performed using metallic coils in all patients (100 %), in association with gelatin sponge in 5/17 patients (29 %). TAE allowed controlling the bleeding and returning to normal hemodynamic status in 16/17 patients (94 %). In 1/17 patient (6 %), surgery was needed to definitively control the bleeding. The mortality and morbidity rate of TAE at 30 days were 0 and 12 %, respectively. Morbidity consisted in coil migration in 1/17 patient (6 %) and transient serum liver enzyme elevation in 1/17 patient (6 %).ConclusionTAE is an effective and safe treatment option for ruptured SAPA in hemodynamically unstable patients, with a success rate of 94 %. Our results suggest that TAE should be the favored option in patients with hemodynamic instability due to ruptured SAPA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Perigraft Plug Embolization of the Internal Iliac Artery and Implantation of a Bifurcated Stentgraft: One Treatment Option for Insufficient Tubular Stentgraft Repair of a Common Iliac Artery Aneurysm

We report an endovascular technique for the treatment of type Ia endoleak after a plain tubular stentgraft had been implanted for a large common iliac artery aneurysm with an insufficient proximal landing zone and without occlusion of the hypogastric in another hospital. CT follow-up showed an endoleak with continuous sac expansion over 12 months. This was classified as type Ia by means of dynamic contrast-enhanced MRI. Before a bifurcated stentgraft was implanted to relocate the landing zone more proximally, the still perfused ipsilateral hypogastric artery was embolized to prevent a type II endoleak. A guidewire was manipulated alongside the indwelling stentgraft. The internal iliac artery could then be selectively intubated followed by successful plug embolization of the vessel’s orifice despite the stentgraft being in place.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Visibility of Metastatic Disease in the Liver During Intra-Arterial Therapy Using Delayed Arterial Phase Cone-Beam CT

PurposeTo compare the visibility of liver metastases on dual-phase cone-beam CT (DP-CBCT) and digital subtraction angiography (DSA), with reference to preinterventional contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver.MethodsThis IRB-approved, retrospective study included 28 patients with neuroendocrine (NELM), colorectal (CRCLM), or sarcoma (SLM) liver metastases who underwent DP-CBCT during intra-arterial therapy (IAT) between 01/2010 and 10/2014. DP-CBCT was acquired after a single contrast agent injection in the tumor-feeding arteries at early and delayed arterial phases (EAP and DAP). The visibility of each lesion was graded by two radiologists in consensus on a three-rank scale (complete, partial, none) on DP-CBCT and DSA images using CE-MRI as reference.Results47 NELM, 43 CRCLM, and 16 SLM were included. On DSA 85.1, 44.1, and 37.5 % of NELM, CRCLM, and SLM, were at least partially depicted, respectively. EAP-CBCT yielded significantly higher sensitivities of 88.3 and 87.5 % for CRCLM and SLM, respectively (p < 0.01), but not for NELM (89.4 %; p = 1.0). On DAP-CBCT all NELM, CRCLM, and SLM were visible (p < 0.001). Complete depiction was achieved on DSA for 59.6, 16.3, and 18.8 % of NELM, CRCLM, and SLM, respectively. The complete depiction rate on EAP-CBCT was significantly higher for CRCLM (46.5 %; p < 0.001), lower for NELM (40.4 %; p = 0.592), and similar for SLM (25 %, p = 0.399). On DAP-CBCT however, the highest rates of complete depiction were found—NELM (97.8 %; p = 0.008), CRCLM (95.3 %; p = 0.008), and SLM (100 %; p < 0.001).ConclusionDAP-CBCT substantially improved the visibility of liver metastases during IAT. Future studies need to evaluate the clinical impact.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temporary arterial shunts to maintain limb perfusion after arterial injury: an animal study

BACKGROUND: Temporary shunt placement can quickly restore perfusion after extremity arterial injury. This study examined the adequacy of limb blood flow with shunt use, non-heparin-bonded shunt patency over prolonged periods, and the safety of this technique. METHODS: Common iliac arteries were divided and 4.0-mm Silastic Sundt shunts placed in 16 anesthetized pigs. Eight (group I) had shunts placed immediately; eight others (group II) were shunted after an hour of limb ischemia and hemorrhagic shock. Physiologic parameters and femoral artery blood flow in both hindlimbs were continuously monitored. Limb lactic acid generation, oxygen utilization, and hematologic and metabolic effects were serially evaluated for 24 hours. RESULTS: Shunts remained patent in 13 of 16 pigs. Shunts thrombosed in two group I animals because of technical errors, but functioned well after thrombectomy and repositioning. Patency could not be maintained in one animal that died from shock. Flow in group I shunted limbs was 57 (+/-11 SD) % of control. For group II animals in shock, shunted limb flow initially averaged 46 +/- 15% of control, but 4 hours after shunt placement, the mean limb blood flow was the same as in group I. Increased oxygen extraction compensated for the lower flow. Lactic acid production was not increased in comparison to control limbs. CONCLUSION: Shunts provided adequate flow in this model of extremity trauma. Correctly placed shunts stayed patent for 24 hours, without anticoagulation, if shunt placement followed resuscitation.

Hindlimb/blood supply/injuries↗