43 records · Page 3

X-Ray and Particle Detection With the Si(Li) Tracker Module of the GAPS Experiment

Here, this work describes the architecture and the experimental results from the characterization of the lithium-drifted silicon (Si(Li)) detector module, which constitutes the building block of the tracker in the general antiparticle spectrometer (GAPS) experiment to search for dark matter. The instrument is designed for the identification of low-energy cosmic anti-nuclei (antiprotons, antideuterons, and antihelium) to be performed during an Antarctic long-duration balloon flight scheduled for late 2025. The GAPS Si(Li) tracker, that is the core of the instrument, is the assembly of 252 modules, each comprised of four Si(Li) detectors and a full custom-integrated circuit designed for detector readout and produced in a commercial 180-nm planar CMOS technology. A general overview of the detector module architecture and its components is provided, together with a description of the test setup and the experimental results obtained from the characterization of the low-noise analog readout channel. In order to verify the effective operation of the entire module, results concerning the detection of X-rays from a 241Am source and cosmic muons are also provided.

Manghisoni, Massimo [Università di Bergamo (Italy)↗

BESS: Present Results and the BESS-Polar Program

In nine flights between 1993 and 2002, the Balloon Borne Experiment with a Superconducting Spectrometer (BESS) has measured the spectrum of cosmic-ray antiprotons between 0.18 and 4.20 GeV, and the spectra of protons and helium to several hundred GeV/nucleon. BESS has also placed stringent upper limits on the existence of antihelium and antideuterons. Above about 1 GeV, models for antiprotons as secondary products of the interactions of primary cosmic rays agree with the BESS spectrum. Below 1 GeV, BESS data suggest the presence of an additional source of antiprotons. To extend BESS measurements to lower energies and to search for antinuclei, an evolutionary instrument, BESS-Polar, is under construction with a new, ultra-thin, superconducting spectrometer optimized for long-duration balloon flights. The initial flight is planned &om Antarctica in Winter 2004-2005. BESS Collaboration: High Energy Accelerator Research Organization (KEK), Japan; NASA Goddard Space Flight Center, USA; Kobe University, Japan; The University of Tokyo, Japan; Institute of Space and Astronautical Science/JAXA, Japan; University of Maryland, College Park, USA.

Ormes, Jonathan↗

The BESS Search for Cosmic-Ray Antiproton Origins and for Cosmological Antimatter

The apex of the Balloon-borne Experiment with a Superconducting Spectrometer (BESS) program was reached with the Antarctic flight of BESS-Polar II, during the 2007-2008 Austral Summer, that obtained 24.5 days of data on over 4.7 billion cosmic-ray events. The US-Japan BESS Collaboration uses elementary particle measurements to study the early Universe and provides fundamental data on the spectra of light cosmic-ray elements and isotopes. BESS measures the energy spectra of cosmic-ray antiprotons to investigate signatures of possible exotic sources, such as dark-matter candidates, and searches for heavier antinuclei that might reach Earth from antimatter domains formed during symmetry breaking processes in the early Universe. Since 1993, BESS has carried out eleven high-latitude balloon flights, two of long duration, that together have defined the study of antiprotons below about 4 GeV, provided standard references for light element and isotope spectra, and set the most sensitive limits on the existence of antideuterons and antihelium. The BESS-Polar II flight took place at Solar Minimum, when the sensitivity of the low-energy antiproton measurements to a primary source is greatest. The rich BESS-Polar II dataset more than doubles the combined data from all earlier BESS flights and has 10-20 times the statistics of BESS data from the previous Solar Minimum. Here, we summarize the scientific results of BESS program, focusing on the results obtained using data from the long-duration flights of BESS-Polar I (2004) and BESS-Polar II.

Mitchell, John↗

The General Antiparticle Spectrometer (GAPS) Antarctic Balloon Payload

The General Antiparticle Spectrometer (GAPS) is an Antarctic stratospheric balloon mission designed to provide unmatched sensitivity to low-energy (<0.25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter. The distinctive GAPS particle identification technique relies on measuring the energy loss along the track of an incoming antinucleus as it slows down and is captured into an exotic atom, and then detecting the de-excitation X-rays and the nuclear annihilation products. This measurement is realized using a Tracker composed of more than 1000 custom silicon strip detectors and a plastic scintillator time-of-flight (TOF) system instrumenting more than 40m$^2$. Together, these subsystems provide the velocity and energy resolution, stopping power, particle tracking, and X-ray identification necessary to distinguish rare antinucleus signals from the abundant positive-nucleus backgrounds, all within the constraints of a high-altitude mission. A multi-loop capillary heat pipe system has been developed to maintain the tracker operating temperature with significant mass and power savings over a conventional pump-based system. The first GAPS science payload flew for 25 days during the 2025/26 NASA Antarctic balloon campaign. We detail the design, integration, and commissioning of the payload prior to flight.

Aoyama, Kazutaka [JAXA, Sagamihara]↗

Fabrication of low-cost, large-area prototype Si(Li) detectors for the GAPS experiment

A Si(Li) detector fabrication procedure has been developed with the aim of satisfying the unique requirements of the GAPS (General Antiparticle Spectrometer) experiment. Si(Li) detectors are particularly well-suited to the GAPS detection scheme, in which several planes of detectors act as the target to slow and capture an incoming antiparticle into an exotic atom, as well as the spectrometer and tracker to measure the resulting decay X-rays and annihilation products. These detectors must provide the absorption depth, energy resolution, tracking efficiency, and active area necessary for this technique, all within the significant temperature, power, and cost constraints of an Antarctic long-duration balloon flight. We report here on the fabrication and performance of prototype 2"-diameter, 1–1.25 mm-thick, single-strip Si(Li) detectors that provide the necessary X-ray energy resolution of ~4 keV for a cost per unit area that is far below that of previously-acquired commercial detectors. Lastly, this fabrication procedure is currently being optimized for the 4"-diameter, 2.5 mm-thick, multi-strip geometry that will be used for the GAPS flight detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Antimatter Factory

Following the proposed d-bar production by p-bar(p-bar, {pi}{sup -})d-bar, (light) antinuclei synthesis can be made by successive use of one and two antinucleon transfer reactions, (d-bar,n-bar),(d-bar,p-bar),(t-bar,p-bar),(t-bar,n-bar),...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

e{sup +} and p-bar from inert doublet model dark matter

In the framework of the Inert Doublet Model, a very simple extension of the Standard Model, we study the production and propagation of antimatter in cosmic rays coming from annihilation of a scalar dark matter particle. We consider three benchmark candidates, all consistent with the WMAP cosmic abundance and existing direct detection experiments, and confront the predictions of the model with the recent PAMELA, ATIC and HESS data. For a light candidate, M{sub DM} {approx} 10 GeV, we argue that the positron and anti-proton fluxes may be large, but still consistent with expected backgrounds, unless there is an enhancement (boost factor) in the local density of dark matter. There is also a substantial anti-deuteron flux which might be observable by future experiments. For a candidate with M{sub DM} {approx} 70 GeV, the contribution to e{sup +} and p-bar fluxes is much smaller than the expected backgrounds. Even if a boost factor is invoked to enhance the signals, the candidate is unable to explain the observed e{sup +} and p-bar excesses. Finally, for a heavy candidate, M{sub DM} {approx} 10 TeV, it is possible to fit the PAMELA excess (but, unfortunately, not the ATIC one) provided there is a large enhancement, either in the local density of dark matter or through the Sommerfeld effect.

79 ASTRONOMY AND ASTROPHYSICS↗