Advanced technical developments in support of scientific experiments in space

A technique was developed for preparing solid state, lithium-drifted silicon detectors. Hollow cylindrical detectors were built and tested for possible use as anticoincidence shields to replace conventional plastic scintillators and photomultipliers. A fission cell was developed for the Pioneer F/G instruments and the IMP I subsystem. An electron current detector was developed for Jovian belt measurements of electron flux. A number of circuits and semiconductor devices was also developed.

Lamport, J. E.↗

Search for X rays from the planet Jupiter.

Actively collimated balloon-borne scintillation counters employing a special phoswich anticoincidence technique were flown a total of 5 times from Palestine, Texas. Jupiter was observed for a total of 133 min, and an upper limit to the flux of X rays present at the observation time is .016 X rays/sq cm sec in the energy range 30-100 keV. Three separate calculations are made to estimate the flux of Jovian X rays at the earth. These estimates range from .000000001 to .1 X rays/sq cm sec in the energy range 30-100 keV. It is concluded that, since there was no decametric emission at the time of the flight and there had been no significant solar activity for several days prior to the flight, no X rays were being generated at the time of the observation.

Hurley, K. C.↗

Electron scattering effects in typical cosmic ray telescopes.

Laboratory measurements have been made of the response of two typical cosmic ray detector systems to electrons between 0.2 and 2.0 MeV. Working laboratory versions of each of these particle telescopes were exposed to the monoenergetic electron beam from a magnetic spectrometer. The results of pulse height and counting rate measurements indicate that electrons scattered from the anticoincidence cup comprise about 25% of the total number arriving at the top of the detector stack. In certain cases, the contribution of these scattered particles to the total number of electrons detected can reach 65%.

Lupton, J. E.↗

Techniques in balloon X-ray astronomy.

Since the first balloon observation of the Crab Nebula balloon data have provided much information on the positions, spectra, time variability and pulsed nature of localized sources, and on the spectrum and isotropy of diffuse galactic and universal components. Measurements are limited to energies above about 20 keV by atmospheric attenuation at 2 to 3 g/sq cm depth and to below several hundred keV by detector sensitivity. Detectors usually consist of large-area Na I or Cs I scintillation counters with anticoincidence collimators for rejection of charged particles and scattered X-rays. Proportional counters are occasionally used at lower energies and solid-state detectors are used where extreme energy resolution is important. The instruments require a pointing capability on the order of 1.0 to 0.1 deg, depending on the collimator aperture. Digital data is either recorded on board or telemetered using a PCM technique.

Peterson, L. E.↗

The cosmic gamma-ray spectrum between 0.3 and 27 MeV measured on the Apollo 15

The spectrum of the total (diffuse and discrete sources) cosmic gamma-ray background over the 0.3 to 27 MeV range was measured with a 7.0 cm diameter x 7.0 cm long uncollimated NaI(Tl) scintillation counter located on a boom 7.6 m from the Apollo 15 service module. Data on cosmic gamma-rays were taken during transearth coast at various boom extensions, detector gains, and with the plastic anticoincidence scintillator enabled and disabled.

Trombka, J. I.↗

Coaxial anode for background suppression in X-ray proportional counters

A scheme which permits the ends (near the anode seals) as well as the bottom and sides of an X-ray astronomy proportional counter to be protected by anticoincidence guard counters is described. A rocket-borne test showed that the non-X-ray background is reduced by an additional factor of about 30 when the end guard counter feature is added.

Bunner, A. N.↗

Coaxial anode for background suppression in X-ray proportional counters.

We have devised, constructed, and tested in flight a scheme which permits the ends (near the anode seals) as well as the bottom and sides of an X-ray astronomy proportional counter to be protected by anticoincidence guard counters. A rocket-borne test has shown that the non-X-ray background is reduced by an additional factor of about 30 when the end guard counter feature is added.

Bunner, A. N.↗

Differential energy spectra of low energy (less than 8.5 MeV per nucleon) heavy cosmic rays during solar quiet times

Explorer 47 satellite observations of carbon, oxygen, and heavier nuclei differential energy spectra below 8.5 MeV/nucleon are presented for solar quiet time periods. A dE/dx vs E method for particle identification and energy determination was used. The instrumentation telescope included an isobutane proportional counter, a surface barrier Si detector, and a cylindrical plastic scintillator anticoincidence shield. The observations were performed outside the bow-shock and in the ecliptic plane. Results show an anisotropy of about 25% at 22 degrees west of the sun with a C/O ratio of 0.5 supporting a solar origin. The low energy portions of the C and O spectra have steep negative slopes, and the corresponding power law is given. Peculiarities in the O spectrum are discussed.

Hovestadt, D.↗

Spectrum of atmospheric gamma rays to 10 MeV at lambda = 40 deg

Results of measurements of the differential counting rate spectra due to atmospheric gamma rays as a function of altitude to 3.6 g/sq cm over Texas. Two gain settings and a 128-channel pulse height analyzer were used to cover the range from 0.2 to 10 MeV. The detector was a 7.6 x 7.6 cm NaI crystal, which was surrounded on five sides by a 2-cm-thick plastic anticoincidence shield for charged particle rejection. The system had a nearly isotropic response to photons above 0.2 MeV. The spectrum at ceiling appeared as a steep continuum with a power-law index of about 1.4. The only obvious feature was the 0.51-MeV positron annihilation line. The spectral shape was independent for depths less than 20 g/sq cm, the absolute intensity varying in proportion to the intensity of the cosmic ray secondary charged particles. Also, at depths less than 30 g/sq cm the observed flux variation with altitude can be described in terms of an empirical depth-dependent source function.

Peterson, L. E.↗

Gamma-spectrometric analysis of Luna 16 sample of lunar surface material

Using a scintillation gamma spectrometer with shielding against anticoincidences, the content of the natural radioelements (K, U, and Th) and long-lived cosmogenic radioisotopes (Al-26, Na-22, and Mn-54) in a sample of Sea of Fertility regolith was determined. Based on the content data of natural radioelements, an attempt was made to classify this sample in the scale of petrochemical types of terrestrial rocks arranged in accordance with their silicic content and alkalinity. Within the frame of reference of calcium-uranium systematics of lunar samples, a comparison was made of the K/U ratio obtained for the Sea of Fertility sample with analogous data for other regions of the moon. Also discussed are problems on the depthwise distribution of cosmogenic radioisotopes along the regolith profile.

Surkov, Y. A.↗

A burst of energetic gamma rays

A burst of gamma rays with energies greater than 1 MeV occurring on May 14, 1972, at 201247 UT (151247 local time) was detected during a balloon flight from Palestine, Texas, at a float altitude of 4g/sq cm residual atmosphere. The detector was a tank of liquid scintillator 1m x 0.5 m x 15 cm surrounded by a 0.6 cm plastic scintillator in anticoincidence. The signal was 60 standard deviations above a steady background of 600 counts/sec. The flux was 0.12 (+0.07 or -0.04) gamma/sq cm, and the time integrated flux 20(+11 or -7) gamma/sq cm. Only one such event was seen during the 8 hours of observation in the daytime on May 14 and 15. Two sub-flares in H alpha occurred during the burst, but not coincident with the start time. A detector on the Solrad satellite observed X-rays on all channels 2 minutes after the gamma ray start time. This event is similar to three earlier reported events.

Koga, R.↗

Observations of discrete gamma ray sources with SAS-2

Compact gamma ray sources centered on the Crab nebula and the Vela X supernova remnant are considered. An excess in the galactic radiation was observed in both regions. Data indicate that a large fraction of this flux is pulsed. The excess from the Vela region could reflect either a large-scale galactic feature, such as a superposition of spiral arm segments, or it could be associated with the Vela supernova remnant. Low-energy gamma ray bursts were observed in the SAS-2 anticoincidence shielding.

Thompson, D. J.↗

Observations of low energy gamma-ray bursts with SAS-2

The present paper reports on the low-energy gamma-ray bursts observed by the plastic scintillator anticoincidence dome of the Small Astronomy Satellite-2 (SAS-2) gamma-ray telescope. SAS-2 detected two events observed by other satellites and discovered one which was subsequently confirmed by other satellite observations. Two events seen by other satellites were not detected by SAS-2, probably due to earth occultation. The event detection threshold for SAS-2 was almost two orders of magnitude lower than that of the Vela satellites.

Oegelman, H.↗

Interpretation of the radioactive background observed in the OSO-7 gamma-ray monitor

Application of a spallation activation calculation to the OSO-7 gamma-ray monitor background shows that major line features and about 30% of the continuum can be understood as activation of the central detector crystal by trapped protons. Weaker line features arise from activation of materials unshielded by the anticoincidence cup, while the remaining continuum and annihilation line would seem to come largely from electron-photon cascades originating in the spacecraft.

Dyer, C. S.↗

Narrow spikes in the selective precipitation of relativistic electrons in mid-latitudes

Relativistic electron precipitation spikes were observed in the quasi-trapped population at midlatitudes by an array of electron detectors aboard the low-altitude polar-orbiting satellite 1972-076B. The fluxes of electrons of energies not less than 4 MeV may undergo pronounced enhancements, while the intensities of electrons in the few hundred keV range may not be significantly affected. Energy spectra and pitch angle distributions were measured over the energy range 160 keV to 2.4 MeV with a combination of three spectrometers. Fluxes of energetic electrons (greater than 4 MeV) were measured with high sensitivity in each of two large plastic scintillator anticoincidence counters surrounding a germanium spectrometer.

Imhof, W. L.↗

Measurement of 0.511-MeV gamma rays with a balloon-borne Ge/Li/ spectrometer

A collimated high-resolution gamma ray spectrometer was flown on a balloon over Palestine, Texas, on June 10, 1974, to obtain measurements of the terrestrial and extraterrestrial 0.511-MeV gamma rays. The spectrometer consists of four 40-cu-cm Ge(Li) crystals operating in the energy range 0.06-10 MeV; this cluster of detectors is surrounded by a CsI(Na) anticoincidence shield. This system is used primarily to allow measurements of the two escape peaks associated with high-energy gamma ray lines. It also allows a measurement of the background component of the 0.511-MeV flux produced by beta(+) decays in materials inside the CsI(Na) shield. It is shown that the measurements of the atmospheric fluxes are consistent with earlier results after allowance is made for an additional component of the background due to beta(+) decays produced by neutron- and proton-initiated interactions with materials in and near the detector. Results of the extraterrestrial flux require an extensive detailed analysis of the time-varying background because of activation buildup and balloon spatial drifts.

Ling, J. C.↗

Rice University observations of the galactic center

The most sensitive of the four balloon fight observations of the galactic center made by Rice University was conducted in 1974 from Rio Cuarto, Argentina at a float altitude of 4 mbar. The count rate spectrum of the observed background and the energy spectrum of the galactic center region are discussed. The detector used consists of a 6 inch Nal(T 1ambda) central detector collimated to approximately 15 deg FWHM by a Nal(T lamdba) anticoincidence shield. The shield in at least two interaction mean free paths thick at all gamma ray energies. The instrumental resolution is approximately 11% FWHM at 662 keV. Pulses from the central detector are analyzed by two 256 channel PHA's covering the energy range approximately 20 keV to approximately 12 MeV. The detector is equatorially mounted and pointed by command from the ground. Observations are made by measuring source and background alternately for 10 minute periods. Background is measured by rotating the detector 180 deg about the azimuthal axis.

Meegan, C. A.↗

The nuclear radiation monitor for the Spacelab/Shuttle

A 5 inch by 5 inch diameter sodium iodide scintillation crystal, viewed by a 5 inch photomultiplier was designed to be mounted near the center of the shuttle payload bay to quantitatively measure the neutron and gamma ray environment during the second Spacelab mission. The expected energy resolution is 8% FWHM at 662 keV. The detector will operate in an energy range from 0.1 to 20 MeV. A charged anticoincidence shield consisting of a 1 cm thick plastic scintillator viewed by three 2 inch photomultiplier tubes, covers the crystal detector which has nearly omnidirectional response.