Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIRFLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Quasi‐dynamic breathing model of the lung incorporating viscoelasticity of the lung tissue

Abstract We advanced a novel model to calculate viscoelastic lung compliance and airflow resistance in presence of mucus, accounting for the quasi‐linear viscoelastic stress–strain response of the parenchyma (alveoli) tissue. We adapted a continuum‐based numerical modeling approach for the lung, integrating the fluid mechanics of the airflow within individual generations of the bronchi and alveoli. The model accounts for elasticity of the deformable bronchioles, resistance to airflow due to the presence of mucus within the bronchioles, and subsequent mucus flow. Simulated quasi‐dynamic inhalation and expiration cycles were used to characterize the net compliance and resistance of the lung, considering the rheology of the mucus and viscoelastic properties of the parenchyma tissue. The structure and material properties of the lung were identified to have an important contribution to the lung compliance and airflow resistance. The secondary objective of this work was to assess whether a higher frequency and smaller volume of harmonic air flow rate compared to a normal ventilator breathing cycle enhanced mucus outflow. Results predict, lower mucus viscosity and higher excitation frequency of breathing are favorable for the flow of mucus up the bronchi tree, towards the trachea.

60 APPLIED LIFE SCIENCES↗

Operator learning for energy-efficient building ventilation control with computational fluid dynamics simulation of a real-world classroom

Energy-efficient ventilation control plays an important role in reducing building energy consumption while ensuring occupant health and comfort. While Computational Fluid Dynamics (CFD) simulations provide detailed and physically accurate representations of indoor airflow, their high computational cost limits their use in real-time building control. In this work, we present a neural operator learning framework that combines the physical accuracy of CFD with the computational efficiency of machine learning to enable building ventilation control with the high-fidelity fluid dynamics models. Our method jointly optimizes the airflow supply rates and vent angles to reduce energy use and adhere to air quality constraints. We train an ensemble of neural operator transformer models to learn the mapping from building control actions to airflow fields using high-resolution CFD data. This learned neural operator is then embedded in an optimization-based control framework for building ventilation control. Experimental results show that our approach achieves significant energy savings compared to maximum airflow rate control, rule-based control, as well as data-driven control methods using spatially averaged CO 2 prediction and deep learning–based reduced-order models, while consistently maintaining safe indoor air quality. These results highlight the practicality and scalability of our method in maintaining energy efficiency and indoor air quality in real-world buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Data Processing Pipeline To Extract A Knowledge Graph From Heterogeneous Data For Socio-technical Analysis Of Critical Infrastructure Influence

The code is written in Python and consists of the following pipeline that is implemented in Apache Airflow. This pipeline intends to understand the companies that are directly or indirectly involved with a type of critical infrastructure system at some point in that system's lifecycle. The pipeline takes a configuration file that specifies a list of initial companies to consider, a geographic region of interest, and a set of SEC form types as well as other data sources (e.g. CrunchBase) from which to extract entities and relations. There are four main components to this pipeline as currently implemented: Entity Extraction, Network Construction, Analysis, and Visualization. First, Entity Extraction, is implemented as the `topear-extract_organizations` Apache Airflow workflow. Given an initial query that specifies a geographic region of interest and a time interval, the software will extract CI facilities of interest and organizations that have a direct influence relationship to those facilities (e.g. ownership). During the course of the LDRD, we focused on Electric Vehicle charging stations and this information is available via the Department of Energy (DOE) database on fueling stations maintained by NREL. Within the context of the DOE CESER project, we have focused on Battery Energy Storage Systems (BESS). Second, the Network Extraction component will iteratively construct a social network graph given the set of organizations and people extracted in the previous step. Organizations (and eventually People if desired) are then fed as a query to the `topgear-construct_social_network` Apache Airflow workflow which given a set of initial companies and data sets (e.g. SEC EDGAR form types, OpenCorporates, Crunchbase). This Airflow workflow will iteratively query such data sources to discover relationships with new organizations and people. For example, this module can iteratively query SEC EDGAR for metadata that documents the number of each type of form for the given set of companies and their location. This forms metadata represents a catalog of data sources from SEC EDGAR for the extracted social network knowledge graph. The pipeline then downloads these forms from the website and saves them in a build directory for further processing. These documents are then parsed for entities and relations. Again, we note that in additional to SEC data sources, this step can also pull in information on organizations via API services such as CrunchBase and OpenCorporates or bulk data sources. At the end of this step, the resultant social network, the Critical Infrastructure network, and the edges that encode relationships between organizations and CI facilities, form the Adversarial Socio-Technical Network (ASTN) that informs the analysis. Third, the Analysis component processes these generated ASTN. Previously, that has included the ability to compare prevalence of different vendors for a given infrastructure component type across different regions as well as identify common public and private investors across those vendors. This was demonstrated for EV Charging Stations across several different metropolitan areas within an IEEE PES GridEdge publication. More recently, we have looked at ways to identify infrastructure owners and operators of BESS with the most nameplate capacity across different states as well as other indictors of risk resulting from changes in ownership over time. Finally, the Visualization component consists of an HTML/CSS/JS framework by which users can interact geospatial, operational, and organizational relationships across a given portfolio of Critical Infrastructure facilities. The objective is to provide a library of UI/UX modules that can be repurposed for stakeholder-specific dashboards. All of the modules are related via a common event model that enables UI actions in one view to percolate across the other views.

Weaver, Gabriel [Idaho National Laboratory (INL), ↗

Building ControlScore: General Service Administration Office Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore concept, which takes operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control). PNNL applied the Building ControlScore application to all available data from a General Services Administration office building within the period of January 1, 2023, to March 9, 2023. The building scored a 4.7 overall, with all 74 of the building’s loops fitting a roughly normal distribution centered around 5. These results indicate that the analyzed systems have below-average performance with room for improvement, especially in the poorly scored systems. Airflow loops tended to have much lower scores than zone temperature loops. The lowest and highest performing systems in the building section were identified, as were all loops with a score less than 1. While the ControlScore identifies loops and systems that aren’t meeting their designated setpoints, it does not indicate the cause of those issues. For example, consider a supply air terminal unit’s airflow loop that received a low score due to it delivering less air than specified by the setpoint. The lower-than-desired airflow could be due to equipment limitations (e.g., the terminal unit or duct serving is too small to accommodate that airflow), malfunctioning equipment (e.g., a stuck damper or bad sensor), or something else entirely. The ControlScore does not diagnose problems it simply identifies the symptoms that can be explored and addressed by building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Glovebox CFD Analysis: Low-Flow, Laminar CFD Analysis of Glovebox Ventilation and Humidity Transport in Ansys Fluent 2025 R1

There are gloveboxes that frequently exceed the 30% relative humidity level required for operations. These exceedances result in alternative operations needing to be utilized. This report documents a computational fluid dynamics (CFD) analysis performed to characterize airflow and humidity transport within a representative glovebox under nominal, low-flow conditions. The analysis focuses on establishing the flow regime, identifying transport-limited regions, and evaluating the implications of laminar flow on humidity removal. A single-phase, laminar flow model with a species transport model was used to represent air and water vapor mixing. Results demonstrate that, at the nominal flow rates, airflow is laminar with weak mixing, which will result in long residence times, tens of minutes long or more, in low-velocity regions. These conclusions suggests that humidity reduction is transport-limited. This analysis provides qualitative insight into airflow structure and humidity transport trends. In addition to characterization of glovebox airflow and humidity transport, results are intended to inform experimental validation and future transient modeling efforts.

42 ENGINEERING↗

Performance Simulation and Analysis of Occupancy-Based Control for Office Buildings with Variable-Air-Volume Systems

Variable-air-volume (VAV) systems are used in many office buildings. The minimum airflow rate setting of VAV terminal boxes has a significant impact on both energy consumption and indoor air quality. Conventional controls usually have the terminal’s minimum airflow rate at a constant (e.g., 30% or more of the terminal design airflow rate), irrespective of the occupancy status, which may cause problems, such as excessive simultaneous heating and cooling, under ventilation, and thermal comfort issues. This paper examines the potential of energy savings from occupancy-based controls (OBCs). The sensed occupancy information, either occupant presence or people count, is used to determine the airflow rate of terminal boxes, the thermostat setpoints, and the lighting control. Using EnergyPlus, a whole-building energy modeling software, the energy savings of OBC strategies are evaluated for representative existing medium office buildings in the U.S. The simulation results show that the conventional OBC, based on occupant presence sensing, can save 8% of whole-building energy use in Miami (hot climate) for systems without air-side economizer and about 13% in both Baltimore (mixed climate) and Chicago (cold climate). Comparatively, the advanced OBC, based on people counting, can save 8% in Miami to 23% in Baltimore for systems with economizers. The outdoor-air fraction of the supply air from air-handling units significantly affects the potential energy savings from the advanced OBC strategy. In addition to energy savings, the advanced OBC satisfies the zone ventilation during all occupied hours over the whole year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooling systems having an integrated ionic liquid salt dehumidification system

A cooling systems utilizes an organic ionic salt composition for dehumidification of an airflow. The organic ionic salt composition absorbs moisture from an inlet airflow to produce an outlet airflow with a reduce moisture from that of the inlet airflow. The organic ionic salt composition may be regenerated, wherein the absorbed moisture is expelled by heating with a heating device. The heating device may be an electrochemical heating device, such as a fuel cell, an electrochemical metal hydride heating device, an electrochemical heat pump or compressor, or a condenser of a refrigerant cycle, which may utilize an electrochemical pump or compressor. The efficiency of the cooling system may be increased by utilization of the waste heat the cooling system. The organic ionic salt composition may circulate back and forth or in a loop between a conditioner, where it absorbs moisture, to a regenerator, where moisture is desorbed by heating.

Bahar, Bamdad↗

Cooling systems having an integrated ionic liquid salt dehumidification system

A cooling system utilizes an organic ionic salt composition for dehumidification of an airflow. The organic ionic salt composition absorbs moisture from an inlet airflow to produce an outlet airflow with a reduce moisture from that of the inlet airflow. The organic ionic salt composition may be regenerated, wherein the absorbed moisture is expelled by heating with a heating device. The heating device may be an electrochemical heating device, such as a fuel cell, an electrochemical metal hydride heating device, an electrochemical heat pump or compressor, or a condenser of a refrigerant cycle, which may utilize an electrochemical pump or compressor. The efficiency of the cooling system may be increased by utilization of the waste heat the cooling system. The organic ionic salt composition may circulate back and forth or in a loop between a conditioner, where it absorbs moisture, to a regenerator, where moisture is desorbed by heating.

Bahar, Bamdad↗

A Novel Simulation-Based Framework for Sensor Error Impact Analysis in Smart Building Systems: A Case Study for a Demand-Controlled Ventilation System

Sensors are one of the fundamental components for sensor-rich controls in buildings but are prone to different errors. Existing studies show that sensor errors hold a place among top-priority faults in building systems. Before we take countermeasures to mitigate the sensor errors, it is vital to prioritize key sensors and quantify the collective impacts of concurrent sensor errors. In response to this, a simulation-based methodology is introduced to conduct a comprehensive sensor error impact analysis in building systems, which adds a stochastic sensor prioritization through a sensitivity analysis on top of a commonly used deterministic sensor error quantification. The synergies of these two parts help better interpret the sensor error impacts on building energy consumption, ventilation performance, thermal comfort, etc. A sensor-rich CO2-based Demand-Controlled Ventilation system is used as a case study to demonstrate the viability of the methodology as a proof-of-the-concept. The results show that the energy savings potential and ventilation performance are mostly influenced by the accuracy of the AHU outdoor airflow sensors. The accuracy of zone level airflow sensors has a negligible impact on both energy savings and ventilation performance. The accuracy of zone CO2 sensors has more influence on the ventilation performance compared with the accuracy of zone airflow sensors. Compared with the baseline case with zero errors, the largest deviation percentages could reach 16.90% and 94.32%, respectively, in terms of the Heating, Ventilation, and Air-Conditioning (HVAC) annual energy consumption and the Outdoor Air Ratio (OAR) when multiple key sensors suffer from normal error intensities simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bringing solar to agriculture: An interdisciplinary design and analysis of a Concord grape agrivoltaic system

Agrivoltaics presents an opportunity to integrate solar photovoltaics (PV) with agricultural production, but crop-specific challenges and operational constraints remain underexplored. This study develops and evaluates a Concord grape agrivoltaic system in the Lake Erie American Viticulture Area, where vineyards face economic pressures and land use conflicts with solar development. Starting with vertical, tracking, and overhead PV systems, we model photosynthetic photon flux density (PPFD) reduction in grapevines and power generation losses from shading using the Agrivoltaic Radiation Tool (ART). Based on these results, which indicate 0.47 % annual grapevine PPFD loss for vertical designs, 1.6 % for tracking, and up to 25 % for the overhead systems, the vertical and tracking designs are selected for further computational fluid dynamics (CFD) analysis to evaluate airflow interactions. CFD results show that vertical panels do not significantly impact airflow through the grapevine canopy, and that tracking systems in horizontal position may enhance airflow compared to a vine-only scenario. Considering operational constraints for tracking systems, the vertical design is selected for an economic evaluation to reveal key financial outcomes for solar developers (14-year payback period) and growers ($408 reduction in financial losses per acre annually). A sensitivity analysis quantifies uncertainty in power generation (±8.8 %) and PPFD (±5.0 %), ensuring model robustness across different vineyard conditions. Furthermore, these findings provide quantitative evidence for the feasibility of Concord grape agrivoltaics, demonstrating a synergistic opportunity for dual-use solar while preserving cultural heritage in grape-growing regions.

14 SOLAR ENERGY↗

Performance study of the cross-flow Maisotsenko cycle in humid climate conditions

This paper presents a first numerical analysis of the cross-flow Maisotsenko cycle (M-Cycle) below dew-point evaporative cooler for humid climates with model including the water vapor condensation phenomenon. Proposed solution allows to cool ambient air below its dew-point temperature, by utilizing cooling energy in air extracted from the building, due to that it can be used as effective pre-cooling solution for traditional systems. Proposed unit has significant advantage over traditional counter and cross-flow units operating in heat recovery mode, hence it is almost insensitive on temperature of exhaust air. This is caused by effective pre-cooling of the exhaust air in its initial part. Operation in humid climates using cold extracted air results in condensation occurrence in the primary air channels, and hence partial dehumidification of the primary airflow (which allows to cool the air before its dew- point temperature). The Maisotsenko cycle exchanger used to recover heat in the air-conditioning system is compared with Maisotsenko exchanger that operates only on the ambient airflow and does not allow to recover heat from the exhaust airflow from a conditioned space. Achieved results showed that M-Cycle below dew-point air cooler can operate more effectively in humid climates than traditional cross-flow Maisotsenko cycle exchanger.

Condensation↗

A multiphase flow model of water droplets dielectrophoretic-induced air dehumidification phenomena

Air humidity in indoor spaces plays a critical role in human comfort and health. Dehumidification systems are used for building humidity controls, but they can take significant energy consumption, especially in geographic locations with high outdoor humidity and warm climates. Consequently, there is a growing demand for innovative dehumidification processes that consume minimal energy. Dielectrophoretic air dehumidification represents one such promising approach. However, it has not garnered significant attention due to the absence of engineering models and simulation tools capable of evaluating its performance and limitations at large-scale airflows. A new numerical multiphase CFD model, which is also experimentally validated, is developed in a customized Reacting Foam solver based on OpenFOAM® version 9. The newly developed model seeks to decrease substantial energy consumption and lower costs by leveraging the dielectrophoretic phenomenon to regulate moisture levels in the air. The solver integrates a hybrid Eulerian-Lagrangian framework to track the droplet's trajectory and growth rate while solving the continuum equations for the moist air. An electrospray produces electrically charged droplets, which grow during their in-flight trajectories as water vapor condenses onto their surfaces. The role of electrostatic forces in promoting vapor condensation within a high-gradient electrical field is investigated, and the dielectrophoretic vapor nucleation process on charged water droplets is discussed. The CFD model was validated against results from the literature and from proof-of-concept experiments conducted by the authors, which showed a 2 % air dehumidification with a single electrospray and airflow rate of 5 cubic feet per minute. The simulation results indicated that augmenting the number of electrically charged spray droplets increased the dehumidification of the air to 25 %. The initial mean droplet diameter, the orientation of the injector and relative humidity significantly influence the assessment of dehumidification. As a result, scaling up this approach to larger airflow volumes is identified as a potential future research direction.

42 ENGINEERING↗

Effects of Different Types of Entrances on Natural Ventilation in a Subway Station

In this study, the natural ventilation of a horizontal entrance of a typical subway station is investigated based on numerical simulations and experiments. In addition, a renormalization group k-e model (RNG k-e model) is applied to compute both the internal and external airflow patterns. Computational fluid dynamics (CFD) simulations are validated based on the experimental results. Furthermore, a multiple variable regression model is employed to study how the different parameters affect the internal airflow rates of the subway station statistically, according to the experimental results. For this typical model, the parameter importance can be ranked as follows: (1) outdoor wind speed; (2) flow resistance of the subway station; (3) height of the wind catcher; and (4) length of the wind catcher. To understand the detailed pressure distribution of the horizontal entrance of the subway station with and without the wind catcher, 3D numerical simulations are conducted for different scenarios. We attempt to alter the size of the wind catcher (including the length and height) to study the characteristics of the pressure on the horizontal entrance of the subway station under outdoor wind-driven conditions. The pressure distributions for the entrance for different scenarios are compared and analyzed. Finally, the interactions between the internal and external flows are investigated by changing the resistance of the subway station. When the internal flow resistance is changed, the pressure coefficient (Cp) of the entrance is different as well. Hence, the Cp is not only affected by the outdoor environment, but is also influenced by the internal airflows.

CFD↗

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling residential heating decarbonization through hydronic low-temperature thermal distribution using forced-air assistive devices

Space heating represents approximately one-tenth of the United States’ energy use and has a breadth of potential for emission reduction. An element of space heating, hydronic heat distribution methods, use water supply temperatures up to 82.2 °C (180 °F). However, this operating temperature can be incompatible with high-efficiency heat generation systems, which typically provide heating temperatures of up to 60 °C (140 °F). In this work, a low-cost retrofit solution is developed using experimentally validated computational tools by incorporating an airflow distributor that preferentially directs the airflow from a fan to enhance heat transfer over the finned-tube heat exchanger found in conventional baseboards. The same heat output of traditional baseboard heat distribution systems operating at higher water supply temperatures (71.1 – 82.2 °C) can also be achieved at lower temperatures (≤60 °C). Specifically, results indicate that the technology can produce more than a 46.7% improvement in the heat transfer output at temperatures as low as 60 °C (140 °F), effectively matching the same output range achieved by 71.1 – 82.2 °C (160–180 °F) water supply temperatures. An important benefit of this solution is that it utilizes the existing infrastructure as opposed to requiring the replacement of the entire distribution system. Additionally, this technology enables existing building infrastructure to be coupled with newer, high-efficiency heating systems such as condensing boilers, solar-thermal systems, and geothermal/air-to-water heat pumps that may produce lower water supply temperatures (60 °C). A geospatially resolved techno-economic and environmental analysis is completed and presented to further understand the equivalent carbon footprint of enabling higher efficiency heat generation systems with the improved efficiency heat distribution system disclosed. Using 2021 grid-average emission factors, an emission reduction of up to a 67.5% decrease (2658 kgCO 2 /yr) for a single-family home, depending on state and climate region, could be realized by replacing a traditional natural gas-fired boiler with an air-to-water heat pump coupled to the same high-temperature heat distribution system along with the low-cost retrofit solution. A complete CO 2 emission reduction of 6688 kgCO 2 /yr, depending on state and climate region, could be realized if all electricity is further renewably sourced. Thus, this study provides a possible pathway towards enabling the reduction of operational emissions in space heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An open source fast fluid dynamics model for data center thermal management

Although computational fluid dynamics (CFD) has been widely adopted to improve data center thermal management, the high computational demand limits its applications, such as multivariate optimal design and operation. Fast fluid dynamics (FFD), which has been applied for fast airflow simulation, shows great potential. However, few research applied FFD for optimal design and operation of data center thermal management. This research improves the FFD model for data centers and conducts a comprehensive evaluation and demonstration. First, the FFD model is improved by solving the advection and diffusion equations together using an upwind scheme instead of a semi-Lagrangian advection solver in the conventional FFD model. Second, new features for data centers are added, such as a pressure correction method to simulate plenum airflow and dynamic boundary conditions for IT racks. The new FFD model is first validated with two indoor environment cases and the results show that the new FFD model has slightly better overall prediction accuracy and faster speed compared to the conventional FFD model. It is also observed that both FFD models achieve acceptable accuracy, except for a few localized disparities with experimental data, which might be due to simplified handling of turbulence viscosity near the boundaries. Furthermore, validation with a real data center shows that the FFD model achieves a similar level of accuracy as CFD when compared to the experimental measurements with some level of uncertainties. It is then demonstrated for data center optimal design and operation, which saves 53.4–58.8% of annual energy while still meeting the thermal requirements. In conclusion, with a much faster speed and comparable accuracy compared to CFD, the FFD model parallelized on a graphics processing unit is promising for practical model-based data center early design and operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Data Center Energy Efficiency Through End-to-End Cooling Modeling and Optimization. Final Report

This report summarizes the development and demonstration of the three features developed for the DOE project “Improving Data Center Energy Efficiency through End-to-End Cooling Modeling and Optimization” (Award No. DE-EE0007688). The development of the three software features, Feature 1: Optimization of Cooling System Operation, Feature 2: Optimization of Airflow Management System, and Feature 3: Simultaneous Optimization of Airflow Management and Cooling Systems, are described first. Feature 1 is implemented in Phase 1 of the project and demonstrates 15% energy savings from cooling system optimization by applying the proposed retrofit solutions. Feature 2 is implemented in Phase 2 and the assessments show cooling energy-saving potential between 19.3% and 54.0%, depending on the energy-saving measures employed. In addition, investigating the energy saving potential for a hypothetical simple data center shows about 6.8% energy savings by optimizing the server load placement. Feature 3 is implemented in Phase 3 and the results show energy savings of 53.4% and 74.6% for the two partner data centers, respectively, compared to the baselines defined in Phase 1. Lastly, the project outcomes including software releases and publications are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ventilation in Residential Care Environments

The purpose of this study was to evaluate the effect of ventilation rate, directional airflow (e.g. pressure relationships) and airflow barriers on bioaerosol concentration and movement within assisted-living and residential care environments. Included within this report is a comprehensive literature review, field data collection test plan and, an evaluation of commercially available mitigation technologies related to the transmission of COVID-19 in LTC environments. Additionally, this report includes aerosol testing in an actual LTC facility using the test plan developed herein. Nearly 1.5 million people live in 16,000 nursing homes in the U.S. As of December 20, 2020 the Centers for Medicare and Medicaid Services (CMS) identified a total of 662,549 confirmed and suspected COVID-19 cases in these and other long-term care (LTC) facilities resulting in 92,373 deaths. At this time, COVID-19 cases in LTC facilities accounted for only 3% of the U.S. total of 21M confirmed cases yet nearly a third of the 350,000 total U.S. deaths. Preliminary studies have found little correlation between the quality of care and transmission of COVID-19 in these facilities, suggesting that even the best infection control practices may not be effective in containing the spread of this potentially airborne disease. As a result, many LTC facilities have implemented quarantine procedures and other measures to isolate infectious residents from the general population. Unfortunately, most LTC facilities were not designed for airborne infection control and guidance for retrofitting existing LTC spaces for airborne isolation is limited.

42 ENGINEERING↗