Airflow resistivity instrument for in situ measurement on the earth's ground surface

An airflow resistivity instrument features a novel specimen holder, especially designed for in situ measurement on the earth's ground surface. This capability eliminates the disadvantages of prior intrusive instruments, which necessitate the removal of a test specimen from the ground. A prototype instrument can measure airflow resistivities in the range 10-5000 cgs rayl/cm, at specimen depths up to 15.24 cm (6 in.), and at differential pressures up to 2490.8 dyn sq cm (1 in. H2O) across the specimen. Because of the close relationship between flow resistivity and acoustic impedance, this instrument should prove useful in acoustical studies of the earth's ground surface. Results of airflow resistivity measurements on an uncultivated grass field for varying values of moisture content are presented.

Zuckerwar, A. J.↗

Portable Airflow Meter

Compact hand-held instrument measures airflow. Consists of hot-wire anemometer probe in flow-straightening tube that reduces swirling. Configuration developed empirically to reduce length of instrument to practical dimension for use and storage in confined space. Two versions of new straightener only 17 and 18 in. long. Weighs less than 8 lb. and readily stored on Space Shuttle, developed to measure airflow in waster-collection system during flight. Used on Earth to measure airflow in ventilation systems, vacuum cleaners, and the like.

Burgett, Frank A.↗

Data Visualization of Invisible Airflow Hazards During Helicopter Takeoff and Landing Operations

Many aircraft accidents each year are caused by encounters with unseen airflow hazards near the ground such as vortices, downdrafts, wind shear, microbursts, or other turbulence. While such hazards frequently pose problems to fixed-wing airplanes, they are especially dangerous to helicopters, which often have to operate in confined spaces and under operationally stressful conditions. We are developing flight-deck visualizations of airflow hazards during helicopter takeoff and landing operations, and are evaluating their effectiveness with usability studies. Our hope is.that this work will lead to the production of an airflow hazard detection system for pilots that will save lives.

Aragon, Cecilia R.↗

Airflow Hazard Visualization for Helicopter Pilots: Flight Simulation Study Results

Airflow hazards such as vortices or low level wind shear have been identified as a primary contributing factor in many helicopter accidents. US Navy ships generate airwakes over their decks, creating potentially hazardous conditions for shipboard rotorcraft launch and recovery. Recent sensor developments may enable the delivery of airwake data to the cockpit, where visualizing the hazard data may improve safety and possibly extend ship/helicopter operational envelopes. A prototype flight-deck airflow hazard visualization system was implemented on a high-fidelity rotorcraft flight dynamics simulator. Experienced helicopter pilots, including pilots from all five branches of the military, participated in a usability study of the system. Data was collected both objectively from the simulator and subjectively from post-test questionnaires. Results of the data analysis are presented, demonstrating a reduction in crash rate and other trends that illustrate the potential of airflow hazard visualization to improve flight safety.

Aragon, Cecilia R.↗

Characterization of Pump-Induced Acoustics in Space Launch System Main Propulsion System Liquid Hydrogen Feedline Using Airflow Test Data

High intensity acoustic edgetones located upstream of the RS-25 Low Pressure Fuel Turbo Pump (LPFTP) were previously observed during Space Launch System (STS) airflow testing of a model Main Propulsion System (MPS) liquid hydrogen (LH2) feedline mated to a modified LPFTP. MPS hardware has been adapted to mitigate the problematic edgetones as part of the Space Launch System (SLS) program. A follow-on airflow test campaign has subjected the adapted hardware to tests mimicking STS-era airflow conditions, and this manuscript describes acoustic environment identification and characterization born from the latest test results. Fluid dynamics responsible for driving discrete excitations were well reproduced using legacy hardware. The modified design was found insensitive to high intensity edgetone-like discretes over the bandwidth of interest to SLS MPS unsteady environments. Rather, the natural acoustics of the test article were observed to respond in a narrowband-random/mixed discrete manner to broadband noise thought generated by the flow field. The intensity of these responses were several orders of magnitude reduced from those driven by edgetones.

Eberhart, C. J.↗

Dilated causal convolutional neural networks for forecasting zone airflow to estimate short-term energy consumption

Here this paper investigates the use of dilated causal convolutional neural networks for fine- grained temporal forecasting of building zone states. Specifically, we build and evaluate models using a small set of exogenous features (e.g., external temperature) to autoregressively predict zone airflow setpoints every minute for a 24-hour prediction window. We carefully explore the trade-off between generality and specificity in these models, training and evaluating them based on zone, zone type, month, season, and combinations thereof. When evaluated for a commercial office building in Eastern Washington with 16 zones served by variable air volume air handling units, we find that the highest performance comes from a zone-specific, season-agnostic approach; with it, we obtain an R 2 of 0.704 (averaged over zones) and an average normalized root mean square error (nRMSE) of 0.111. In contrast, the most general model (trained across all zones and seasons) yields an R 2 of only 0.416 and a nRMSE of 0.168, while a baseline zone-specific reduced order model obtains 0.443 R 2 and 0.159 nRMSE. We also report on factors affecting airflow forecasting performance, on the ability of models trained on a specific zone to generalize to other zones, and on the capability of those models trained on a specific month to generalize to other months.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of basic airflow configurations for separate sensible and latent cooling systems with indoor air recirculation

Separate sensible and latent cooling (SSLC) is a technology with efficiency and comfort advantages over conventional cooling systems used for space conditioning of buildings. Using multiple cooling processes at different temperatures allows SSLC to save energy by raising the evaporation temperature of the sensible cooling process. In this paper, all possible airflow configurations of SSLC systems are enumerated under the following constraints: exactly two heat exchangers are used, and air is recirculated to the conditioned space (no exhaust or outdoor air treatment). Seven designs are identified, with varying free operating variables, and each is modeled. Analysis reveals that several configurations are equivalent, and there is only one unique basic airflow SSLC configuration: the one with the sensible and latent heat exchangers placed in series. The efficiency of the SSLC system is compared against that of the conventional system. Under standard conditions, an SSLC system can improve the coefficient of performance by 14.8%. In addition to the numerical simulation, the optimal operating condition of the basic air configuration of the SSLC system is derived analytically. The basic SSLC system is shown to offer the highest performance improvement when the outdoor temperature is relatively cool and the space sensible heat ratio is high.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ECAR-7428 Rev 0 MARVEL Upper Confinement Structure Airflow Analysis

This ECAR documents airflow values calculated for the Upper Confinement Structure (UCS) design, which is a subsystem of the Microreactor Applications Research Validation and Evaluation (MARVEL) reactor. These airflow values are calculated based on current design parameters and heat removal requirements and are needed to verify the UCS can adequately maintain a target design temperature.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Fast-airflow tumble clothes dryer with small thermoelectric heat pump: Experimental evaluation

Residential clothes drying accounts for about 5% of the total residential-sector energy consumption in the United States. Most dryers use electric resistance heaters to dry clothes and have low efficiencies. Higher-efficiency dryers that use vapor compression heat pumps are expensive and complex and have not gained a large market share in the United States. A novel tumble clothes dryer using a small thermoelectric heat pump with faster airflow than typical dryers is presented in this work. The benchtop performance of the thermoelectric heat pump and high-speed blower are presented, and the development of the prototype dryer is described. The dryer was tested for efficiency and dry time for a range of airflow rates and applied currents to the thermoelectric heat pump. The combined efficiency factor was 5.09–6.29 lb BDW /kWh (specific moisture extraction rate of 1.23–1.53 kg w /kWh) with 100–138 min dry times for these tests. The measured efficiency was 36 %–68 % greater than the minimum efficiency standard in the United States, and compared with vapor compression heat pump–based clothes dryers, the prototype dryer had less expensive, less complex components and did not use refrigerants. Finally, the performance of this small thermoelectric heat pump clothes dryer is also compared with previous iterations of the thermoelectric tumble clothes dryer described in the literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantification of air leakage paths: a comparison of airflow and acoustic measurements

Today, the fan pressurization method is the most frequently used method to evaluate a building's airtightness. However, the localization and quantification of leaks remain difficult. In this paper, an acoustic method is introduced to estimate the leakage size of single leaks. Acoustic and airflow measurements were conducted and compared in laboratory tests within the same boundary conditions. This work aims to investigate if various leak sizes can be predicted using acoustic measurement methods. The test apparatus consists of two chambers, separated by a test wall. This wall represents a single characteristic air leakage path. Various types of wall structures with different slit geometries, wall thicknesses, and insulation materials were investigated. The acoustic measurements were performed with a sound source placed in one chamber and ultrasonic microphones located in both chambers. These results were compared to measured airflows through the test wall to provide estimates of uncertainty in the acoustic approach, which indicate a linear trend. Finally, these laboratory measurements were compared to the same measurements at a real office building. Finally, although the acoustic measurement uncertainty is still significant (greater than +/- 50%), the acoustic method has the potential to give an order of magnitude of single leak sizes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated fault detection and diagnosis of airflow and refrigerant charge faults in residential HVAC systems using IoT-enabled measurements

While automated fault detection and diagnosis (AFDD) in residential heating, ventilation, and air-conditioning (HVAC) using smart thermostat data is gaining increasing attention in recent times, it still requires in-depth investigation for market adoption, especially with real-life data. Furthermore, this paper proposes an Internet of Things (IoT) - based approach that adds a smart sensor to the smart thermostat data to carry out AFDD. The approach uses a model which predicts enthalpy change across the evaporator and compares the prediction to the measured enthalpy change. Deviations which exceed analytically determined thresholds then signal faults in the HVAC system. The faults detected are either installation related or degradation related. Experimental tests were carried out in four homes located in Norman, Oklahoma. From the tests, installation issues like indoor/outdoor mismatch were detected in two homes, while a 30% low charge and low indoor airflow rate were detected in one home. The results show that the proposed AFDD algorithm was able to successfully detect two prevalent faults, namely low indoor airflow and low refrigerant charge. Unlike most of the smart thermostat-based approaches, the proposed IoT-based approach can detect and diagnose both faults but only require one additional sensor which is provided by smart thermostat manufacturers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coolant pressure and airflow distribution in a strut-supported transpiration-cooled vane for a gas turbine engine

An analysis to predict pressure and flow distribution in a strut-supported wire-cloth vane was developed. Results were compared with experimental data obtained from room-temperature airflow tests conducted over a range of vane inlet airflow rates from 10.7 to 40.4 g/sec (0.0235 to 0.0890 lb/sec). The analytical method yielded reasonably accurate predictions of vane coolant flow rate and pressure distribution.

Kaufman, A.↗

Evaluation of circumferential airflow uniformity entering combustors from compressors. Volume 2: Data supplement

A study of the airflow uniformity leaving compressors and entering combustors was made using compressors from two advanced engines, the J58 and F100/F401. The data used in the analysis of each case is presented in tabular form and computer-generated profile plots. A plot of the square root of the dynamic pressure ratio, which is similar to airflow deviation, is also presented.

Shadowen, J. H.↗

Evaluation of an experimental short-length annular combustor: One-side-entry dilution airflow concept

A test program was conducted to evaluate an experimental short-length annular combustor that uses a one-side-entry dilution airflow concept. The combustor design features scoops on the outer liner for controlling the primary- and secondary-zone airflow distribution. Combustor inlet total pressures were limited to 62 N/sq cm (90 psia) with inlet-air temperatures from 590 K (600 F) to 890 K (1150 F). At a diffuser inlet Mach number of 0.25, the exit temperature pattern factor was 0.44 with an average exit temperature of 1436 K (2124 F) and a total pressure loss of 4.3 percent. At a diffuser inlet Mach number of 0.31, the exit temperature pattern factor was reduced to 0.29 with an average exit temperature of 1450 K (2151 F) and a total pressure loss of 6.1 percent. Nominal combustion efficiencies of 100 percent were obtained with the ASTM A-1 fuel. Exhaust gas emissions, smoke, and altitude relight data are included with exit-temperature profiles and distribution patterns.

Humenik, F. M.↗

Pressure activated stability-bypass-control valves to increase the stable airflow range of a Mach 2.5 inlet with 40 percent internal contraction

The throat of a Mach 2.5 inlet with a coldpipe termination was fitted with a stability-bypass system. The inlet stable airflow range provided by various stability-bypass entrance configurations in alternate combination with several stability-bypass exit controls was determined for both steady-state conditions and internal transient pulses. Transient results were also obtained for the inlet with a choke point at the diffuser exit. Instart angles of attack were determined for the various stability-bypass entrance configurations. The response of the inlet-coldpipe system to internal and external oscillating disturbances was determined. Poppet valves at the stability-bypass exit provided an inlet stable airflow range of 28 percent or greater at all static and transient conditions.

Mitchell, G. A.↗

Comparison of calculated and altitude-facility-measured thrust and airflow of two prototype F100 turbofan engines

A comparison is made of the facility performance data for the two engines with an engine performance model, and it provides corrections that can be applied to the model so that it represents the test engines accurately over the flight envelope. Test conditions ranged from Mach numbers of 0.80 to 2.00 and altitudes from 4020 meters to 15,240 meters. Two distortion screens were used to determine the effect of distortion on airflow. Reynolds number effects were also determined. Engine hysteresis is documented, as is an attempt to determine engine degradation. The calibrated engine model had a twice standard deviation accuracy of approximately 1.24 percent for corrected airflow and 2.38 percent for gross thrust.

Kurtenbach, F. J.↗

Aerodynamic-wave break-up of liquid sheets in swirling airflows and combustor modules

Experimental mean drop diameter data were obtained for the atomization of liquid sheets injected axially downstream in high velocity swirling and nonswirling airflow. Conventional simplex pressure atomizing fuel nozzles and splash type fuel injectors were studied under simulated combustor inlet airflow conditions. A general empirical expression relating recirprocal mean drop diameter to airstream mass velocity was obtained and is presented. The finest degree of atomization, i.e., the highest value of the coefficient C, was obtained with swirl can combustor modules (C = 15) as compared with pressure atomizing nozzles (C = 12).

Ingebo, R.↗

Aerodynamic-wave break-up of liquid sheets in swirling airflows and combustor modules

Experimental mean drop diameter data were obtained for the atomization of liquid sheets injected axially downstream in high velocity swirling and nonswirling airflow. Conventional simplex pressure atomizing fuel nozzles and splash type fuel injectors were studied under simulated combustor inlet airflow conditions. A general empirical expression relating reciprocal mean drop diameter to airstream mass velocity was obtained and is presented. The finest degree of atomization, i.e., the highest value of the coefficient C, was obtained with swirl can combustor modules (C = 15) as compared with pressure atomizing nozzles (C = 12). Previously announced in STAR as N83-23545

Ingebo, R.↗