Securing the Modern Grid: Federal Investments, Digitization, and Supply Chain Strategy

Across the United States (U.S.) grid expansion and modernization is underway, paving the way for accelerated load growth and intelligent resource management. Digitization of the grid is supported by several state and federal programs, providing support for utilities installing advanced metering infrastructure (AMI), AI-powered analytics systems, battery energy storage systems (BESS), and distributed energy resource management systems (DERMS) to transform the grid from a one-way power delivery system into an intelligent, responsive network that will enable faster load growth and power expansion of data centers for advanced artificial intelligence (AI) applications. The digital transformation of America's grid presents opportunity for increased efficiency and resiliency but also introduces new digital risks that require careful management. Digital equipment often contains several vulnerabilities such as unencrypted communication protocols, and persistent remote access capabilities that could be exploited to manipulate device settings, coordinate service disruptions, or inject false data into grid operations. These digital risks become particularly important as the grid must rapidly scale to support AI-driven data centers, which the administration has identified as essential for maintaining U.S. technological leadership and economic competitiveness. These vulnerabilities are compounded by supply chain realities: Chinese manufacturers currently produce 70-90% of essential grid components including inverters, batteries, and control systems, with the U.S. lacking domestic manufacturing capacity for critical assets like extra-high voltage transformers. Recent federal legislation has established Foreign Entity of Concern (FEOC) restrictions to address these risks, requiring projects to achieve escalating thresholds of non-FEOC content to receive tax credits while utilities work to expand sourcing channels for their supply chains and strengthen security measures. These restrictions arrive precisely when utilities face unprecedented electricity demand growth driven by the rapid growth in data centers, creating a considerable challenge: rapidly expanding infrastructure while navigating complex compliance requirements while lacking viable alternatives for many critical components. Idaho National Laboratory (INL) and its partners have developed practical approaches to help utilities navigate these intersecting challenges as they leverage federal investment to strengthen and grow the grid. These solutions include Cyber-Informed Engineering (CIE) principles that build resilience directly into systems, the Cirrus tool for secure cloud migration, and enhanced procurement guidance that embeds security requirements throughout equipment lifecycles. Federal initiatives, such as the Technical Assistance for Digital Assurance (TADA) project, provide direct support to utilities implementing these approaches while facilitating knowledge sharing across the industry. While these tools and frameworks cannot eliminate all risks inherent in foreign supply chain dependencies, they offer pragmatic pathways for strengthening security posture without sacrificing the deployment momentum essential to meeting surging electricity demand. Ultimately, securing America's digital energy infrastructure demands dedicated coordination across multiple fronts: building domestic supply chains, implementing robust digital assurance practices, and maintaining the aggressive modernization timeline necessary for reliability, resilience, and energy independence.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Considerations for Distributed Edge Data Centers and Use of Building Loads to Support Large Interconnections

The rapid expansion of artificial intelligence (AI) and machine learning is driving unprecedented electricity demand from data centers. It is predicted that by 2030, 90% of AI workloads will be inference-based, requiring interconnection of multiple low-latency edge data centers (<20 MW) sited closer to end users - often on already constrained distribution feeders. Although individually small, these loads can aggregate to large loads per feeder, straining infrastructure, creating multi-year interconnection delays, and driving up customer costs. This paper proposes a data center-focused grid-integration framework that combines feeder hosting capacity analysis with building energy efficiency, building load flexibility, and waste heat reuse to expand effective feeder and substation headroom. Such approaches can reduce interconnection delays, lower costs for ratepayers, and accelerate AI-ready infrastructure deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooling Matters: Benchmarking Large Language Models and Vision-Language Models on Liquid-Cooled Versus Air-Cooled H100 GPU Systems

The unprecedented growth in artificial intelligence (AI) workloads, recently dominated by large language models (LLMs) and vision-language models (VLMs), has intensified power and cooling demands in data centers. This study benchmarks LLMs and VLMs on two HGX nodes, each with 8× NVIDIA H100 graphics processing units (GPUs), using liquid and air cooling. Leveraging GPU Burn, Weights & Biases, and IPMItool, we collect detailed thermal, power, and computation data. Results show that the liquid-cooled systems maintain GPU temperatures between 41-50$^\circ$C, while the air-cooled counterparts fluctuate between 54-72$^\circ$C under load. This thermal stability of liquid-cooled systems yields 17% higher performance (54 TFLOPs/ GPU vs. 46 TFLOPs/GPU), performance-per-watt, reduced energy overhead, and greater system efficiency than the air-cooled counterparts. These findings underscore the energy and sustainability benefits of liquid cooling, offering a compelling path forward for hyperscale data centers seeking to optimize AI infrastructure. https://github.com/iscaas/Cooling-Matters.

Latif, Imran↗

A Centralized AI Lakehouse Framework for Brain Tumor MRI Classification and Segmentation, University KPI Forecasting, and Water Potability Prediction

In many university and healthcare projects, models are built for very different data types such as tables, institutional time series, and medical images, but they are deployed as separate applications. In this work, that separation made testing and maintenance difficult because each module had its own pipeline and runtime requirements. This paper presents an integrated AI lakehouse-style implementation that runs three model pipelines inside one containerized backend. For medical imaging, we used MRI datasets from IEEE DataPort: a four-class classification set with 7012 images (5708 train/1304 test) and a segmentation set with 3063 image–mask pairs. The classification model (ResNet50 transfer learning) is evaluated using a proper train–validation–test protocol across multiple splits (80/10/10, 70/10/20, 60/10/30, and 10/30/60), achieving a test accuracy of 99.00% under the standard 80/10/10 split. Additionally, a patient-level evaluation is conducted using an external glioma dataset to provide a more realistic assessment without data leakage. The segmentation model (DeepLabV3-ResNet50) achieved 83.09% validation mIoU and 88.79% Dice score. For university KPI forecasting, we used annual IPEDS and NSF HERD data from 2010 to 2023 for three universities (BSU, EOU, and UAB). To examine the effect of preprocessing on forecasting performance, two case studies are conducted. In the first case, linear interpolation is applied to generate semester-level data. In the second case, the original annual data is used directly without interpolation. Random Forest regression and ARIMA models are evaluated using MAE, RMSE, MAPE, and R 2 . The results showed that interpolation improved apparent forecasting performance due to smoothing, while evaluation on the original annual data provided a more realistic assessment of model behavior. To further validate the framework on a larger dataset, an additional case study is conducted using a student dropout dataset. For water potability, we trained and compared multiple tabular classifiers on a large dataset (1,048,575 samples). A Random Forest model (100 trees, max depth 10) achieved 85.86% test accuracy and high recall for unsafe samples (0.8447). All modules are served via FastAPI and deployed together using Docker, with workflow automation routing requests to the correct endpoint. System-level benchmarking indicates that the backend maintains stable throughput and latency under concurrent requests.

97 MATHEMATICS AND COMPUTING↗

Adapting Grid Criticality for Data Centers

This presentation explores the evolving definition of “critical load” in the electric grid, emphasizing the growing importance of digital infrastructure—particularly data centers—in grid resilience, restoration, and modernization. As utilities increasingly rely on AI-driven analytics and software-defined control systems, data centers have shifted from passive electricity consumers to essential computational hubs that enable National Critical Functions (NCFs) and support real-time grid operations. The deck examines the scale and impact of digital loads, the need for grid modernization to manage rapid load growth, and the diverse computing paradigms required for AI deployment. It introduces a tiered taxonomy for classifying critical loads, highlights operational dependencies between the grid and digital infrastructure, and discusses policy implications for integrating data centers into emergency planning and restoration protocols. Through case studies and practical frameworks, the presentation provides actionable insights for utilities, regulators, and planners navigating the digital transformation of the power sector.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

The Future of a Myriad of Accelerated Biodiscoveries Lies in AI‐Powered Mass Spectrometry and Multiomics Integration

The intersection of modern artificial intelligence (AI) and mass spectrometry (MS) is set to transform the MS‐based “omics” research fields, particularly proteomics, metabolomics, lipidomics, and glycomics, enabling advancements across a wide range of domains, from health to environment and industrial biotechnology. Beginning with an overview of key challenges inherent in MS software pipelines, this personal perspective explores how AI‐driven solutions can address them to enhance data processing, integration and interpretation. It proposes a paradigm shift in molecular identification and quantitation algorithms, leveraging AI to enable holistic interpretation of MS‐based multiomics data. While centered on MS‐based omics, this holistic AI‐driven paradigm is also critical for connecting dynamic biochemical changes to genomics and transcriptomics contexts, reinforcing the integrative value of MS in multiomics research. Ultimately, this AI‐driven approach could enhance efficiency, accuracy, and molecular breadth of coverage, deepening our systems‐level understanding of biological processes and accelerating a myriad of biodiscoveries.

47 OTHER INSTRUMENTATION↗

Navigating Integration: Key Challenges for Data Centers, Nuclear Stakeholders, and Utility Operators

The rapid expansion of data centers, driven by the exponential growth in data-processing and storage needs, presents significant challenges and opportunities for various stakeholders, including data center developers, nuclear energy providers, and utility companies. Data centers are projected to consume 6.7–12% of United States (U.S.) electricity by 2028, driven by artificial intelligence (AI) and cloud-computing demands. Nuclear energy offers reliability and dispatchable baseload power, but data centers need power now while nuclear still needs time to address siting, fast power ramping, and regulatory hurdles. Utilities must keep pace with the unprecedented acceleration of large load interconnection requests and urgently adapt to high-density loads while maintaining grid stability, reliability, and accelerating interconnection timelines. This report dives into these challenges and proposes key collaboration strategies to streamline data center integration that aligns with recent federal initiatives like America’s AI Action Plan and related executive orders that emphasize the importance of data center growth, nuclear energy expansion, and maintaining a competitive edge in the global AI race.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Data Center High-Temperature Liquid Cooling and Heat Reuse Techno-Economic Study: Preprint

Data centers are energy-intensive facilities with growing demands for efficiency and cost-effective operations. Smaller, more distributed edge inference data centers are expected to proliferate as AI applications require low latency closer to the user of AI tools, which presents a growing opportunity to explore the systems implications of liquid cooling on water and energy use. This study analyzes the implementation of high-temperature liquid cooling systems in a prototypical inference 1-MW data center and explores the potential for heat reuse across varying climates with a goal to optimize energy efficiency, reduce capital and operational costs, and identify opportunities for high-performance cooling and water use reduction infrastructure. This analysis evaluated configurations utilizing a peak day hourly sizing and systems performance spreadsheet to evaluate design and operational conditions from which component sizes, installed cost, operational cost, and performance metrics were determined for the Base case and the Elevated case. The techno-economic analysis included heat reuse applications across a range of heat recovery temperatures and heat rejection options. The analysis shows that high-temperature liquid cooling allows for improved energy efficiency, lower water consumption, and lower capital costs compared to traditional cooling approaches. Transitioning to elevated water inlet/outlet temperatures (50 degrees C/60 degrees C) eliminates the need for chillers, cooling towers, and heat recovery equipment in many scenarios across three distinct climate zones. This results in up to 75% capital cost savings for the cooling and heat recovery equipment, and with significantly reduced water consumption, especially in non-heat reuse applications. Heat generated from data centers can also be repurposed for space heating, domestic hot water, and other applications, and is most cost-effective when data center outlet temperatures exceed 55-60 degrees C.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Introduction: Neuromorphic Materials

The explosive growth in data collection and the need to process it efficiently, as well as the desire to automate increasingly complex tasks in transportation, medical care, manufacturing, security and many other fields have motivated a growing interest in neuromorphic computing. Unlike the binary, transistorbased ON/OFF logic gates and separate logic and memory functionalities employed in digital computing, neuromorphic computing is inspired by animal brains that use interconnected synapses and neurons to perform processing, storage and transmission of information at the same location, while only consuming ~20 W or less of power. Motivated by the brain’s efficiency, adaptability, self-learning and resiliency qualities, neuromorphic computing can be broadly defined as an approach to processing and storing information using hardware and algorithms inspired by models of biological neural systems. Present research in neuromorphic computing encompasses approaches that vary significantly in their degree of neuro-inspiration, from systems that only incorporate features such as asynchronous, event-driven operation or use crossbar arrays of non-volatile memory (NVM) elements to accelerate deep neural networks (DNNs), to designs that embrace the extreme parallelism, sparsity, reconfigurability, adaptability, complexity and stochasticity observed in nervous systems. The term ‘neuromorphic’ computing is often credited to Carver Mead, who in the 1980s investigated Si-based analog electronics to replicate functions of the animal retina. Earlier important advances in this field include the work of Frank Rosenblatt, who proposed the concept of the perceptron, Bernard Widrow, who used this concept to build one of the first analog neural networks, the Adaline and many other researchers (see ref. 6 for an historical perspective on neuromorphic computing). With the recent increase in the use of artificial intelligence and large language models, and rising concerns over the associated energy costs, interest in neuromorphic hardware has expanded rapidly. According to some estimates, driven largely by the drastic growth in the training use of artificial intelligence (AI) models using the current computing architectures, the energy cost of computing is projected to reach the energy supply worldwide by 2045. Furthermore, while this is not a realistic outcome, it means that, if more efficient computing technologies are not developed -- soon -- the world will soon become one where demand for energy and market constraints limit the continued increase of societal access to AI and cloud services from data centers. Data centers used for training and use of these models consume hundreds of terawatt hours of electricity, already past 4% of the US electricity demand.

Circuits↗

Data Center Cybersecurity, Supply Chain Risk Management, and Emerging Regulation Cohort Summary: Takeaways and Action Plans

This report summarizes the outcomes of the Data Center Cohort under the Department of Energy’s Technical Assistance for Digital Assurance (TADA) initiative, aimed at enhancing grid resilience through cybersecurity, supply chain risk management (SCRM), and Cyber-Informed Engineering (CIE). The cohort engaged 17 organizations across utilities, data center operators, vendors, and technology providers in three sessions combining presentations, discussions, and exercises. Key topics included AI-driven load behavior, cybersecurity vulnerabilities in UPS/BESS and cooling systems, governance gaps at utility–data center boundaries, and supply chain integrity. Five cross-cutting themes emerged: interconnection architecture vulnerabilities, fragmented governance, AI-driven stability risks, lack of regulatory frameworks, and long-term supply chain concerns. Actionable recommendations were developed, including implementing DMZ segmentation, formalizing vendor access agreements, designing AI workload limits, and advancing standards through NERC and state-level programs. These strategies aim to strengthen resilience, clarify responsibilities, and ensure secure integration of data centers into the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Vulcan Test Platform: Demonstrating the Data Center as a Flexible Grid Asset

Explosive data center demand is outpacing grid infrastructure development. AI workloads and hyperscale cloud growth are creating unprecedented power requirements, while traditional grid expansion faces multi-year development timelines, regulatory hurdles, and decarbonization challenges. Sidewalk Infrastructure Partners recognized this impending crisis years ago and founded Verrus to develop an innovative solution: data centers that function as grid assets rather than passive loads. The Verrus approach integrates proprietary grid-aware controls with battery energy storage systems (BESS) in a medium-voltage architecture that delivers three critical capabilities: Fast-responding demand flexibility that can service requests from the utility within 10 seconds, Uninterrupted transition to islanded operation during grid disturbances, Continuous uptime assurance while maintaining all customer service level commitments Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), we validated these capabilities on Vulcan, a 70 MW utility-scale test platform powered by NREL's ARIES Virtual Emulation Environment. This deployment-ready technology has successfully demonstrated that Verrus data centers can deliver meaningful grid services while maintaining mission-critical reliability. This technical report outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can play a pivotal role in enhancing grid flexibility and reliability, without sacrificing service level guarantees.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reducing Data Center Peak Cooling Demand and Energy Costs with Underground Thermal Energy Storage (UTES)

By recent estimates, data center energy demands are projected to consume between 6.7% and 12% of U.S. annual electricity generation by the year 2028, driven primarily by expanded demands from cloud services, big data analytics, and Artificial Intelligence (AI) (Shehabi et al., 2024). As much as 40% of data center total energy consumption are loads associated with the site infrastructure cooling systems, and these are often highly water consumptive (Aljbour et al., 2024). For energy system planners, this presents significant challenges to meeting and managing the anticipated loads, and especially the peak loads of projected data center deployments. Geothermal technologies offer two unique solutions to these challenges: 1) by serving loads through the deployment of new conventional and/or next-generation geothermal power technologies such as EGS and 2) through an often-overlooked opportunity to reduce data center peak cooling loads. The latter is the focus of this paper which explores Cold Underground Thermal Energy Storage ("Cold UTES") as an emerging industrial-scale geothermal cooling solution. This cooling solution is energy efficient, non-water-consumptive, and utilizes long duration energy storage (LDES) on both diurnal and seasonal time scales. Cold UTES has the potential to also function as a virtual power plant (VPP). The US Department of Energy's Geothermal Technologies Office is supporting R&D to understand the grid and system-wide value, costs, and impacts of deploying this emergent cooling solution at scale.

AI↗

Addressing Rising Energy Demand Through Innovation

The U.S. is facing a significant increase in energy demand, driven by AI advancements, the rapid expansion of data centers, manufacturing and industrial growth, and the electrification of transportation and buildings. Buildings alone account for approximately 75% of U.S. electricity consumption and 40% of total energy use. To address these challenges, NLR leverages its state-of-the-art research facilities, advanced energy modeling, hardware-in-the-loop emulation, and real-world demonstrations to provide data-driven insights that de-risk emerging energy solutions, increase efficiency and demand flexibility, optimize grid controls, and identify vulnerabilities to enhance energy security. This presentation will highlight our research ecosystem and its role in supporting a more reliable, affordable, and adaptive energy infrastructure in the face of accelerating demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dataset of Generative AI Workload Power Profiles

This dataset provides a collection of high-resolution (5/10 Hz or every 0.2/0.1 seconds) power consumption profiles for generative artificial intelligence (GenAI) workloads executed on NLR's High Performance Computing (HPC) platform Kestrel. The dataset also includes examples of representative whole-facility power profiles generated using a bottom-up, event-driven, data center energy model . This dataset is designed to support research in energy modeling, infrastructure planning, energy system integration, and sustainability analysis for AI-driven computing systems. The dataset captures time-resolved electrical power measurements across a diverse set of configurations, including variations in job type (inference vs. training), workload (LLM vs. image generation), datasets, and number of compute nodes. Power traces are provided in a standardized format and include both raw/instantaneous and aggregated files. Each profile is accompanied by metadata describing workload parameters, enabling reproducibility and cross-study comparison. The dataset is intended for use in applications such as data center infrastructure planning, energy modeling, demand response and grid impact studies, and development and validation of system-level simulation tools. By making these workload-specific power profiles publicly available, this dataset aims to address the current lack of open, empirical energy data for generative AI systems and to facilitate transparent, reproducible research on the energy and environmental impacts of large-scale AI deployment. If you use this dataset, please cite the associated publication: Vercellino et al., “Measurement of Generative AI Workload Power Profiles for Whole-Facility Data Center Infrastructure Planning,” arXiv:2604.07345 (2026).

97 MATHEMATICS AND COMPUTING↗

Empirically-calibrated H100 node power models for accurate AI training energy estimation

Accurately quantifying the energy use of artificial intelligence (AI) training is critical for infrastructure planning, carbon accounting, and sustainable data center operation, but few studies have directly measured the power consumption of production workloads on contemporary hardware. By combining empirical measurements from Brookhaven National Laboratory during AI training on 8-graphics-processing-unit H100 systems with open-source benchmarking data, we develop statistical models relating computational intensity to node-level power consumption. We measure the gap between manufacturer-rated thermal design power (TDP) and actual power demand during AI training. Our analysis reveals that even computationally intensive workloads operate at only 76% of the 10.2 kW TDP rating. Our architecture-specific model, calibrated to floating-point operations, predicts energy consumption with 11.4% mean absolute percentage error, significantly outperforming TDP-based approaches (27%–37% error). We identified distinct power signatures between transformer and convolutional neural network architectures, with transformers showing characteristic fluctuations that may impact grid stability. These results provide a measurement-grounded basis for improving AI training energy estimates, enabling more reliable infrastructure sizing, cost projections, and environmental impact assessments.

Newkirk, Alex C↗

Advancing Sustainability in Data Centers: Evaluation of Hybrid Air/Liquid Cooling Schemes for IT Payload Using Sea Water

Abstract-The growth in cloud computing, Big Data, AI and high-performance computing (HPC) necessitate the deployment of additional data centers (DC's) with high energy demands. The unprecedented increase in the Thermal Design Power (TDP) of the computing chips will require innovative cooling techniques. Furthermore, DC's are increasingly limited in their ability to add powerful GPU servers by power capacity constraints. As cooling energy use accounts for up to 40% of DC energy consumption, creative cooling solutions are urgently needed to allow deployment of additional servers, enhance sustainability and increase energy efficiency of DC's. The information in this study is provided from Start Campus' Sines facility supported by Alfa Laval for the heat exchanger and CO 2 emission calculations. The study evaluates the performance and sustainability impact of various data center cooling strategies including an air-only deployment and a subsequent hybrid air/water cooling solution all utilizing sea water as the cooling source. Here we evaluate scenarios from 3 MW to 15+1 MW of IT load in 3 MW increments which correspond to the size of heat exchangers used in the Start Campus' modular system design. This study also evaluates the CO 2 emissions compared to a conventional chiller system for all the presented scenarios. Results indicate that the effective use of the sea water cooled system combined with liquid cooled systems improve the efficiency of the DC, plays a role in decreasing the CO 2 emissions and supports in achieving sustainability goals.

97 MATHEMATICS AND COMPUTING↗

From Electronic Structure to Ion Transport: Photoelectron Spectroscopy and Molecular Dynamics Simulations Reveal the Role of Anions in Lithium Battery Electrolytes

Electrolyte anions are pivotal for lithium battery performance, yet their fundamental electronic structural properties are not well understood. In this work, we employ a combination of negative-ion photoelectron spectroscopy (NIPES), ab initio calculations, and molecular dynamics (MD) simulations to investigate the electronic structures of three representative electrolyte anions. This multiscale approach enables us to elucidate how their intrinsic electronic properties govern anion–solvent interactions in gas-phase clusters, as well as lithium-ion (Li + ) solvation structures and ion transport behavior in the condensed phase. NIPES reveals that difluoro(oxalato)borate (DFOB – ), bis(fluorosulfonyl)imide (FSI – ), and bis(oxalato)borate (BOB – ) all exhibit high electron binding energies, with vertical/adiabatic detachment energies increasing from DFOB – (6.09/5.70 eV) to FSI – (6.80/6.10 eV) to BOB – (6.82/6.40 eV), correlating with enhanced oxidation stability. Ab initio calculations reveal that DFOB – /FSI – –solvent complexes bind Li + ∼ 10 kcal/mol stronger than BOB – series, aligning with the strength of a Li + –anion model. DFOB – exhibits pronounced charge localization on both oxygen and fluorine atoms, enabling their involvement in Li + coordination. In contrast, fluorine atoms in FSI – are largely electron-depleted and remain excluded from direct Li + binding. MD simulations further demonstrate that LiDFOB and LiFSI systems exhibit Li + diffusion coefficients three and five times higher than those of LiBOB across four common solvents. Notably, LiFSI salt in acetonitrile (AN) exhibits the fastest Li + diffusion among 12 electrolyte systems, highlighting the synergistic effect of FSI – and AN in promoting ion mobility. In conclusion, these findings provide a molecular-level understanding of the critical roles of anion and its microsolvation in optimizing Li + diffusion dynamics, once again emphasizing the positioning of FSI – and DFOB – as prime candidates for next-generation electrolytes.

25 ENERGY STORAGE↗